3Interior signage > Table of contents

Similar documents
signsvisual i n d u s t r i e s servicing New York City since 1991.

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Lucent.

CLEAR-DIVISIONS CENTERFOLD

ITEM NO. DESCRIPTION BIDDER CODE NO. UNIT COST UNIT COST 1 GALLON 5 GALLON. 1 Oil Base Exterior House Paint Mobille Paint 5-18 $29.

REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $

CLEAR-DIVISIONS VARIOFOLD

SALES (800) FAX

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Coat Racks Floor Racks Hooks Hangers Hook Panels Wardrobes

CLEAR-DIVISIONS APERTO

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Laminating Films - Heat Activated

Concepts. Products. Service. Lindner Plus Organisation

Barewood Octagon and Elongated Windows Installation Instructions

Can you design a frameless shower enclosure that doesn't leak?

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Electrical Wiring Technical Bulletin

glass & Glazing Products

17,280 square feet Overview:

A. Shop Drawing submittals shall include, but not be limited to, the following:

A Complete Solution CREATING WALLS THAT DEFINE SPACE

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Drylac POWDER COATINGS

Window Installation Instructions

Automatic Door Selection Guide

Your single source graphic solution.

Mobile Home Pre-Inspection Checklist

ASI/81350 PPAI/ UPIC: POLYPAK- SAGE

FIRE-FIGHTING DESIGN BRIEF REPORT

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg

Denco Sales Aspire Catalog

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

KIOSK CATALOG Debevoise Avenue Roosevelt, NY

PUBLIC RESTROOMS, DESIGN INTENT

Accessorize Your Home with Pendant Lamps

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Quick response concealed horizontal sidewall sprinkler

electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S

PRICELIST. GlasBoards VINYLBACKEDGLASS STAND-OFFMOUNTING

Mystery. God s. Dwelling. the. Banner #3

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Large Format Printing Media Options

RADAR

Mazda CX

Irvinton Village Apartments 2901 Fulton Houston, Texas Houston Housing Authority J. Allen Management Managing Agent

Cable & Rod Displays DELIVERY NEXT DAY

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

Booth Design Package 2015

X0 XL0. Signkit FE. Disc. Project. Pictogram. Signslot. Signblock. Bespoke. Rod. Signkit - a complete. system of precision. engineered components

new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex

Pantone Matching System Color Chart PMS Colors Used For Printing

GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

Kempsville Volunteer Rescue Squad. Ambulance Graphics Package

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

Laboratory Construction Guidelines Vicon MX Systems

Lee, Here are the questions from bidders received between August 17, 2015 and August 24, 2015 followed by our responses.

Pantone Color Chart Plexiglas Cross Reference

CABLE SUPPORT SYSTEMS

9300BC SERIES Light Commercial Door Closer

Engraving source book

How to secure your property after a disaster

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Stair Parts Installation. Tricks

Final Software Tools and Services for Traders

JOB READY ASSESSMENT BLUEPRINT PAINTING AND DECORATING. Test Code: 2060 Version: 01

SECTION PIPE HANGERS AND SUPPORTS

ADDENDUM NO. 2. DATE: September 14, 2015 INVITATION FOR BID: IFB J Fire Station #22 Roof Replacement Project DATED: August 25, 2015

Simplified Steel Stair Design for Commercial and Institutional Buildings

Speaker Installation Guide: In-Wall / In-Ceiling

Stair Railing. Installation Guide

SECTION (16630) RESCUE ASSISTANCE TELEPHONE SYSTEM (Rev Jun 2011)

FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

Wayfinding Study: The Wallace Center

Microsoft Access 2010 handout

Maersk Container Train Lego # Qty PartNum Color Description Picture Note

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Standard Design TKLP Cab

Roloc TM. Discs. Easy to mount easy to change

DIY CABINET REFACING INSTALLATION GUIDE

WINDOW INSTALLATION GUIDE

PORTABLE MODULAR DISPLAY DESCRIPTION KIT 115, 129, & 135

Drylac * ** anodized effect. anodized effect. anodized effect Light Bronze 61/ anodized effect Bronze 61/68002

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

Installation Instructions

TOTAL SHOWROOM SOLUTIONS 2014 CATALOG. Palmer Promotional Products. dish.palmerdist.com/catalog

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

SECTION 6. Glass Storefront Doors:

Measurement Standards for Structures

DE Frame with C Series Sidelight

contents classic 3 switch 4 mini swing 5 sign wedge 6 chalkboards 7 all purpose A frames 8 H2O swingmaster 9 café banner 10 vision 11

19 DYNAmax Free Standing Server C A B I N E T s

Transcription:

3Section 3 > Interior signage

3Interior signage > Table of contents Fabrication and finish codes Hospital fabrication and finish codes... 33 Education and office building fabrication and finish codes... 37 Snead Hall and the School of Engineering East Hall fabrication and finish codes... 41 Sign specifications 1 Entry Lobby Directory (1/2)... 43 Floor Directory (1/3)... 44 2 Room Identification (2/3)... 45 Office Occupant Identification Carrier (2/3.1)... 46 Room Number Identification (2/3.2)... 47 Patient Information (2/3.3)... 48 Floor Level Identification Elevator Lobby (2/4)... 49 Restroom Identification (2/6 and 2/6.1)... 50 Minor Room Identification (2/7)... 51 Slide Bar (2/8)... 52 Informational/Large Format Dimensional Letters (2/9)... 53 3 Overhead Wayfinding (large) (3/1.1, 3/1.2 and 3/1.3)... 54 Overhead Wayfinding (small) (3/2.1 and 3/2.2)... 55 Overhead Wayfinding Directional (3/3)... 56 Overhead Identification (3/3.1)... 57 Wall-mounted Wayfinding Department Suite Identification (3/4.1, 3/4.2, 3/4.3, 3/4.4, 3/4.5 and 3/4.6)... 58 Wall-mounted Directional and Area Identification (3/5)... 59 Emergency Evacuation/Help Signs (3/6)... 60 4 Horizontal Information with Window (4/1)... 61 Vertical Information with Window (4/2)... 62 Information (small) (4/3.1 and 4/3.2)... 63 Information (small) (4/4.1 and 4/4.2)... 64 Information (large) (4/5.1 and 4/5.2)... 65 Multi-informational (4/6)... 66 5 Fire Exit Identification (5/5)... 67 Authorized Personnel Only/ Do Not Enter (5/5.5)... 68 Fire Stair Identification (5/5.6)... 69 Stair Tower Level Identification (5/5.7)... 70 In Case of Fire (5/5.8)... 71 Fire Egress Map Hallway (5/6)... 72 Fire Egress Map Elevator Lobby (5/7)... 72 6 Information Sign (6/1)... 73 Information Sign with Insert (6/2)... 74 Restroom Identification (6/3)... 75 Secondary Room Identification (6/4)... 76 Donor Plaque (6/5)... 77 VCU Signage Manual 31

Section 3 > Interior signage > Table of contents Suite Identification (6/6)... 78 Stair Identification (small) (6/7)... 79 Stair Identification (large) (6/7.1)... 79 Fire Evacuation Map with Insert (large) (6/8)... 80 Fire Evacuation Map with Insert (small) (6/8.1)... 80 32 VCU Signage Manual

3Interior signage > Fabrication and finish codes Hospital building code legend A Main Hospital......... Violet/Blue B North Hospital......... Violet/Blue C Massey Cancer Center..... Violet/Blue E Randolph Minor Hall...... Violet/Blue F A.D. Williams Clinic...... Teal Green G West Hospital......... Teal Green H Medical Sciences Building... Teal Green J Sanger Hall........... Teal Green K Nelson Clinic........ Muted Orange L Ambulatory Care Center.. Muted Orange M Wood/Lyons Dental Building. Muted Orange P Parking........... Muted Orange Q Virginia Treatment Center for Children......... Muted Orange R Gateway Building....... Blue/Violet Hospital fabrication and finish codes Code H1 Two-layer, insert-pocketed fabrication using 1/16 matte clear acrylic sheet with background color sprayed on second surfaces to match Color 4. Top layer masked to create window for 1/64 -thick clear polycarb changeable insert with black applied die-cut vinyl copy. Sign unit includes two applied header components of photopolymer with 1/32 raised message and grade 2 Braille. Header Component A with background sprayed to match appropriate Route Color 1, 2 or 3. Header Component B with background and Braille sprayed Color 6 semigloss metallic polyurethane enamel. All raised copy finished white semigloss and then coated with a clear matte finish. Code H1.1 Same basic fabrications as Code 1 but without changeable insert with window feature, therefore base layer can be single layer 1/8 -thick matte clear acrylic. Back sprayed to match Color 4 (see Room Number Identification sign type 2/3.2). Code H1A Similar to Code 1 two-layer, insert-pocketed fabrication, but using 1/8 -thick matte clear acrylic sheet and incorporating multiple pockets for multiple clear polycarb changeable insert strips with black (type) and white (arrow) die-cut applied copy with back-screened disc form behind arrows as per sign type 1/3 sketch. Header area requires second-surface screened copy in white, with back sprayed Color 6. VCU Signage Manual 33

Section 3 > Interior signage > Fabrication and finish codes Header area also includes photopolymer Code H1C.1 Code H2 Code H4A components same as components A and B Changeable slider panel fabrication to 1/8 -thick matte clear acrylic sheet fab- 1/8 -thick matte clear acrylic sheet in Code 1 Fabrication. be used as add-on unit mounted flush to rication with copy screened on second screened in second surface with black bottom edge of typical Conference Room surface in black and background color copy as indicated and back-sprayed in two Code H1B Identification signage. sprayed on the second surface to match colors as follows: Header area in Color 6; Similar to Code 1A except larger in format It shall reveal or conceal words Vacant Color 4. remainder to match Color 4. with different header configuration and or Occupied by means of opaque back- Sign unit includes applied photopolymer with separate modules for left- and right- sprayed 1/16 -thick matte clear acrylic header strip (with room number and grade Code H4A.1 hand insert columns. sheet slider panel to match Color 4. 2 Braille). Same fabrication as 4A with addition of Copy to be subsurface screen in black. Background and Braille painted Color 6 custom bent matte clear acrylic easel Code H1C All sign unit background color to be sub- semigloss metallic polyurethane enamel. component, size to be flush with top, left Insert-pocketed fabrication to be used as surface and match Color 4. All raised copy to be white semigloss. and right of sign unit which shall be per- add-on unit mounted flush to bottom edge manently bonded to it. of typical Room Identification Signage. Code H1D Code H3 It shall accommodate up to three layers Layed fabrication to accept 8 1/2 x11 1/8 -thick matte clear acrylic sheet base Code H4B of 1/64 -thick polycarb (opaque back- paper inserts. layer with applied photopolymer, full- 1/8 -thick matte clear acrylic sheet with sprayed to match Color 4) name inserts 1/8 -thick matte clear acrylic sheet surface bleed surface layer. all copy screened on second surface. which can be removed, shuffled and re- layer with black copy screen on second Background color and grade 2 Braille to be Based on specific sign unit. inserted to display appropriate occupant s surface then masked and back-sprayed in Color 6 semigloss metallic polyurethane Some sign units (e.g., sign type 3/4.3 and name in shared single office situations. two colors: header area to match Color 6. enamel. 3/4.4, Wall-mounted Wayfinding Depart- Pocket opening shall be 1/16 deep to All remaining areas to match Color 4. All raised copy to be white semigloss. ment Suite Identification) will require an allow hidden storage of multiple inserts, Base layer to be fabricated with 1/4 -thick arrow disc module. one behind another. matte clear acrylic sheet and shall include Code H3A Thumb hole cutaways in base layer are two 1/2 -diameter (semicircular) thumb Same fabrication method as Code 3 (pho- Code H5 indicated on sign type 2/3.1, Office Occu- holes one centered on each vertical topolymer on acrylic-based layer) except Ceiling-mounted, double-sided directional/ pant Identification Carrier, Page 44. edge to aid in access for removal of for color finish reverse on primary plaque locational signage fabricated from.063 All color to be subsurface and match Color 4. paper inserts. area below visual header area (see sign aluminum plate faces bonded to 1/4 -thick Insert copy to be black die-cut. type 2/6, Restroom Identification, Page 48). Sintra core layer. Sign units shall include message backgrounds painted semigloss to match 34 VCU Signage Manual

Section 3 > Interior signage > Fabrication and finish codes Color 4, applied text in black die-cut vinyl, Code H6 Color-coding system applied white die-cut vinyl route alpha Painted aluminum fabrication similar to Code H7A over custom mask and sprayed square to match appropriate route color, custom arrow discs (for directionals) and blank discs (for suite locationals) as described in Code Code 5A but with background painted Color 6. For Main Lobby Wayfinding, fabrication will be of.063 aluminum bonded to base 1/16 -thick matte clear acrylic disc backsprayed with Color 6. White die-cut vinyl arrow art as required, applied to first surface (complete units Color 1: Match PMS 2597 Violet/ Blue Route Color Indicator 7A and depicted on sign type 3/4, Wallmounted Wayfinding Department Suite Identification, Page 56, and sign type 3/1.1 and 3/2.2, Overhead Wayfinding, pages 52 layer (or core layer if two-sided) of 1/4 -thick Sintra board. Sintra base or core layer shall be cut flush to outer surface layers and be fin- bond to surfaces of Code 5 fabrications). Alternate (if more cost-effective): 1/16 -thick aluminum or acrylic disc; surface sprayed with applied die-cut arrow Color 2: Match PMS 321 Teal Green Route Color Indicator and 53. Mounting shall be by threaded studs set into Sintra core layer of sign units. Installation shall be flush to ceiling as ished smooth, primed and filled to appear free from flaws when final painted finish is applied. Message legends white with various art as required. Code H8 Cut letters in 1/4 -thick acrylic painted Color 3: Match PMS 1595 Muted Orange Route Color Indicator depicted on sign type 3/1.1 and 3/2.2, Overhead Wayfinding, pages 52 and 53. Some units may require pendant-rod Route Color and/or Emergency vinyl appliqués as required. Mounting methods will vary as physical Color 6. Code H10 Color 4: Match PMS 468 Pale Ivory Signage Background suspended mounting because of higher conditions require. Two-layer, insert-pocketed fabrication ceiling heights. Code H5A Same basic fabrication and mounting Most Main Lobby (Building A, 1st Floor) Type 3/3 sign units will mount to face of concrete beams. Others will require special flush-to-ceil- using 1/16 matte clear acrylic sheet with background color sprayed on second surfaces to match Color 4. Top layer masked to create window for Color 5: Match PMS 185 Primary Red Emergency and Restrictive Color Indicator method as Code 5 but format smaller. Background painted semigloss to match Color 4. Copy black die-cut vinyl. ing mounting with concealed hardware tapped into Sintra core layer of each sign unit. 1/64 -thick clear polycarb changeable insert with black applied die-cut vinyl copy. Sign unit includes applied header component B with background sprayed Color 6 Color 6: Match AKZO 209-E4 Dark Copper Metallic Route Color Indicator Code H7 White die-cut vinyl arrow art applied to surface of polycarb inserts. Disc screened to second surface in Color 6. semigloss metallic polyurethane enamel. Color 7: Match PMS 293 Primary Blue Parking Color Indicator VCU Signage Manual 35

Section 3 > Interior signage > Fabrication and finish codes Color 8: Black Artwork, text and copy bars Color 9: White Text and arrows 36 VCU Signage Manual

3Interior signage > Fabrication and finish codes Education and office building fabrication and finish codes Code E1 Two-layer, insert-pocketed fabrication using 1/16 matte clear acrylic sheet with background color sprayed on second surfaces to match Color 11. Top layer masked to create window for 1/64 -thick clear polycarb changeable insert with black applied die-cut vinyl copy. Sign unit includes two applied header components of photopolymer with 1/32 raised message and grade 2 Braille. Header Component A with background sprayed to match Color 12. Header Component B with background and Braille sprayed Color 10 semigloss metallic polyurethane enamel. All raised copy finished black semigloss and then coated with a clear matte finish. Code E1.1 Same basic fabrications as Code 1 but without changeable insert with window feature, therefore base layer can be single 1/8 -thick matte clear acrylic. Back sprayed to match Color 11 (see Room Number Identification, sign type 2/3.2). Code E1A Similar to Code 1 two-layer, insert-pocketed fabrication, but using 1/8 -thick matte clear acrylic sheet and incorporating multiple pockets for multiple clear polycarb changeable insert strips with black (type) and black (arrow) die-cut applied copy with back-screened disc form behind arrows as per sign type 1/3 sketch. Header area requires second-surface screened copy in black, with back sprayed Color 10. Header area also includes photopolymer components same as components A and B in Code 1 fabrication. Code E1B Similar to Code 1A except larger in format with different header configuration and with separate modules for left- and righthand insert columns. Code E1C Insert-pocketed fabrication to be used as add-on unit mounted flush to bottom edge of typical Room Identification Signage. It shall accommodate up to three layers of 1/64 -thick polycarb (opaque back-sprayed to match Color 11) name inserts which can be removed, shuffled and re-inserted to display appropriate occupant s name in shared single office situations. VCU Signage Manual 37

Section 3 > Interior signage > Fabrication and finish codes Pocket opening shall be 1/16 deep to All remaining areas to match Color 11. Code E3A Code E5 allow hidden storage of multiple inserts, Base layer to be fabricated with 1/4 -thick Same fabrication method as Code 3 (pho- Ceiling-mounted, double-sided directional/ one behind another. matte clear acrylic sheet and shall include topolymer on acrylic-based layer) except locational signage fabricated from.063 Thumb hole cutaways in base layer are two 1/2 diameter (semicircular) thumb for color finish reverse on primary plaque aluminum plate faces bonded to 1/4 -thick indicated on sign type 2/3.1, Office Occu- holes one centered on each vertical area below visual header area (see sign Sintra core layer. pant Identification Carrier, Page 44. edge to aid in access for removal of type 2/6, Restroom Identification, Page 48). Sign units shall include message back- All color to be subsurface and match Color 11. paper inserts. grounds painted semigloss to match Color Insert copy to be black die-cut. Code E4A 11, applied text in black die-cut vinyl cus- Code E2 1/8 -thick matte clear acrylic sheet tom arrow discs (for directionals) and blank Code E1C.1 1/8 -thick matte clear acrylic sheet fab- screened in second surface with black discs (for suite locationals) as described in Changeable slider panel fabrication to rication with copy screened on second copy as indicated and back-sprayed in two Code 7A and depicted on sign type 3/4.5 be used as add-on unit mounted flush to surface in black and background color colors as follows: header area in Color 10; and 3/4.6, Wall-mounted Wayfinding bottom edge of typical Conference Room sprayed on the second surface to match remainder to match Color 11. Department Suite Identification, Page 56, Identification signage. Color 11. and sign type 3/1.1 and 3/2.2, Overhead It shall reveal or conceal words Vacant Sign unit includes applied photopolymer Code E4A.1 Wayfinding, pages 52 and 53. or Occupied by means of opaque back- header strip (with room number and grade Same fabrication as 4A with addition of Mounting shall be by threaded studs set sprayed 1/16 -thick matte clear acrylic 2 Braille). custom bent matte clear acrylic easel into Sintra core layer of sign units. sheet slider panel to match Color 11. Background and Braille painted Color 10 component, size to be flush with top, left Installation shall be flush to ceiling as Copy to be subsurface screen in black. semigloss metallic polyurethane enamel. and right of sign unit which shall be per- depicted on sign type 3/1.1 and 3/2.2, All sign unit background color to be sub- All raised copy to be black semigloss. manently bonded to it. Overhead Wayfinding, pages 52 and 53. surface and match Color 11. Some units may require pendant-rod Code E3 Code E4B suspended mounting because of higher Code E1D 1/8 -thick matte clear acrylic sheet base 1/8 -thick matte clear acrylic sheet with ceiling heights. Layed fabrication to accept 8 1/2 x11 layer with applied photopolymer, full- all copy screened on second surface. paper inserts. bleed surface layer. Based on specific sign unit. Code E5A 1/8 -thick matte clear acrylic sheet surface Background color and grade 2 Braille to be Some sign units (e.g., sign type 3/4.3 and Same basic fabrication and mounting layer with black copy screen on second Color 10 semigloss metallic polyurethane 3/4.4, Wall-mounted Wayfinding Depart- method as Code 5 but format smaller. surface then masked and back-sprayed in enamel. ment Suite Identification) will require an Background painted semigloss to match two colors: header area to match Color 10. All raised copy to be black semigloss. arrow disc module. Color 11. Copy black die-cut vinyl. 38 VCU Signage Manual

Section 3 > Interior signage > Fabrication and finish codes Code E7 Black die-cut vinyl arrow art applied to surface of polycarb inserts. Disc screened to second surface in Color 10. Code E7A 1/16 -thick matte clear acrylic disc backsprayed with Color 10. Black die-cut vinyl arrow art as required, applied to first surface (complete units bond to surfaces of Code 5 fabrications). Alternate (if more cost-effective): 1/16 -thick aluminum or acrylic disc; surface sprayed with applied die-cut arrow art as required. Code E8 Cut letters in 1/4 -thick acrylic painted Color 10 or 12. Code E10 Two-layer, insert-pocketed fabrication using 1/16 matte clear acrylic sheet with background color sprayed on second surfaces to match Color 11. Top layer masked to create window for 1/64 -thick clear polycarb changeable insert with black applied die-cut vinyl copy. Sign unit includes applied header component B with background sprayed Color 10 semigloss metallic polyurethane enamel. Color-coding system Color 10: Silver MAP 41-342 SP brushed aluminum New interior used on Monroe Park Campus Color 11: Alabaster MAP 13A-3P Alabaster New interior used on Monroe Park Campus Color 12: Black New interior used on Monroe Park Campus The swatches shown are representations of the actual Pantone colors. Actual Pantone matches should be used by the sign fabricator in appropriate finishes for all VCU signage. VCU Signage Manual 39

3Interior signage > Fabrication and finish codes Snead Hall and the School of Engineering East Hall fabrication and finish codes Code SE1 Fabricated with a 6 (H) by 6 (W) by 1/16 (D) photopolymer face with 1/32 raised text and Grade 2 Braille. Background subsurface painted Color 1 with ADA clear coat and black foil copy. Sign unit includes applied decorative bar header and footer measuring 1 (H) by 6 (W) and finished in Color 2. Sign is finished with a 7-3/4 (H) by 6 (W) by 1/4 (D) black sintra backer. Code SE1.2 Same basic fabrication as Code SE1 but with a 9 (H) by 8 (W) by 1/16 (D) photopolymer face. Fill panel measures 9 (H) by 8 (W) by 1/8 (D) with acrylic background painted Color 1. Sign is finished with a 10-3/4 (H) by 8 (W) by 1/4 (D) black sintra backer. Code SE1.3 Same basic fabrication as Code SE1 but with a 5-1/2 (H) by 8 (W) by 1/16 (D) photopolymer face. Fill panel measures 5-1/2 (H) by 8 (W) by 1/8 (D) with acrylic background painted Color 1. Sign is finished with a 7-1/4 (H) by 8 (W) by 1/4 (D) black sintra backer. Code SE2 Two-layer, insert-pocketed fabrication using 4-5/8 (H) by 8 (W) clear lexedge with black foil copy and bordered at the top and bottom by a 5-1/2 (H) by 8 (W) by 1/16 (D) clear non-glare acrylic backpainted with Color 1. Visual opening measures 4-1/2 (H) by 8 (W) with a 5-1/2 (H) by 8 (W) by 1/8 (D) background fill panel painted Color 1. Sign unit includes applied decorative bar header and footer measuring 1 (H) by 8 (W) and finished in Color 2. Sign is finished with a 7-1/4 (H) by 8 (W) by 1/4 (D) black sintra backer. Code SE3 Fabricated with a 2 (H) by 8 (W) by 1/8 (D) acrylic face backpainted with Color 1. Mounted under X/X Suite ID. Type is reverse engraved with letters backfilled with Color 3. Fill panel measures 2 (H) by 8 (W) by 1/16 (D) with acrylic background painted Color 1. VCU Signage Manual 41

Section 3 > Interior signage > Fabrication and finish codes Sign unit includes applied decorative bar Code SE5 Code SE6 Color-coding system header and footer measuring 1 (H) by 8 (W) and finished in Color 2. Sign is finished with a 3-3/4 (H) by 8 (W) Fabricated with a 6 (H) by 6 (W) by 1/16 (D) photopolymer face with 1/32 raised text and Grade 2 Braille. Two-layer, insert-pocketed fabrication with a 15 (H) by 15 (W) by 1/16 (D) clear, non-glare acrylic with subscreened red Color 1: Sherwin-Williams Rice Grain (SW 6155) by 1/4 (D) black sintra backer. Background subsurface painted Color 1 text and backpainted with Color 1. Code SE4 Two-layer, insert-pocketed fabrication with ADA clear coat and black foil copy. Fill panel measures 6 (H) by 6 (W) by 1/8 (D) with acrylic background painted Clear lexedge insert measures 10-3/4 (H) by 15 (W) with digital print. Visual opening measures 10-5/8 (H) by 15 (W). Color 2: Satin yellow gold finish on hardware (JRS #214) with an 8 (H) by 8 (W) by 1/16 (D) pho- Color 1. Fill panel measures 15 (H) by 15 (W) by topolymer face with 1/32 raised text and Grade 2 Braille. Sign unit includes applied decorative bar header and footer measuring 1 (H) by 1/8 (D) with acrylic background painted Color 1. Fill panel has a routed groove to Color 3: Black foil Background subsurface painted Color 1 6 (W) and finished in Color 2. hold insert. with ADA clear coat and black foil copy. Sign is finished with a 7-3/4 (H) by 6 (W) Sign unit includes applied decorative bar Clear lexedge 4-5/8 (H) by 8 (W) insert by 1/4 (D) black sintra backer. header and footer measuring 1 (H) by with black foil copy. Clear visual opening 15 (W) and finished in Color 2. measures 4-1/2 (H) by 9 (W). Code SE5.1 Sign is finished with a 16-1/2 (H) by Fill panel measures 8 (H) by 8 (W) by Same basic fabrication as Code SE5 ex- 15 (W) by 1/4 (D) black sintra backer. 1/8 (D) with acrylic background painted cept with a 12 (H) by 12 (W) by 1/16 (D) Color 1. Fill panel has routed groove to photopolymer face; a 12 (H) by 12 (W) Code SE6.1 hold insert. by 1/8 (D) fill panel; and a 13-3/4 (H) by Same basic fabrication as SE6 but with a Sign unit includes applied decorative bar 12 (W) by 1/4 (D) black sintra backer. 12 (H) by 15 (W) by 1/16 (D) clear, non- header and footer measuring 1 (H) by Sign unit includes applied decorative bar glare acrylic; a 12 (H) by 15 (W) by 1/8 (D) 8 (W) and finished in Color 2. header and footer measuring 1 (H) by 1 fill panel; and a 13-1/2 (H) by 15 (W) by Sign is finished with a 9-3/4 (H) by 8 (W) (W) finished in Color 2. 1/4 (D) black sintra backer. by 1/4 (D) black sintra backer. 42 VCU Signage Manual