1. Auditorium Capacity

Similar documents
Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Contacts. The Space. Lx Kit List. Sound Kit List. Stage Management. Health & Safety Policy

CORONET LONDON / Technical Information Pack (Updated - 1 st January 2015)

Technical Specifications Lyric Theatre Belfast Danske Bank Stage

TECHNICAL SPECIFICATIONS

PA and Lighting Packages - Ready to Go

Equipment Hire Rate Card!

MEETING PACKAGES 400 LEVEL

Theaters Tilburg - Concertzaal. Address

The Civic Hall in Bedworth Technical Specification

Les Docks / Av. de Sévelin Lausanne! Technical Rider

Divadlo Inspirace (Ints-per-ats-zay)

FOOTHILL COLLEGE FINE ARTS FACILITIES OFFICE

TECHNICAL RIDER AUDIO - MAINSTAGE F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE P.A. LINE ARRAY 4 WAY

TEATR GROTESKA ul. SKARBOWA KRAKÓW TEL groteska@groteska.pl Update

PRODUCTION SPECIFICATIONS

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER CAPACITY. Stalls: 257 Seats per row: 22(Max)

Scale of Hire Charges

TECHNICAL SPECIFICATIONS.

Douglas J. Cardinal Performing Arts Centre. Information and Technical Specifications

Service Charges & Price List 2014

J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO THEATRE TECHNICAL INFORMATION MARCH 29, 2013

TECHNICAL RIDER

STAGE SPECIFICATIONS. Newberry Opera House

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

PRODUCTION SPECIFICATIONS THE MANÈGE (RIDEHUSET)

Adress: Teatertorvet DK Horsens Denmark. Postal adress: P.O.Box DK 8700 Horsens. Phonenr, etc..

CIRCUS INCOGNITUS. Technical Rider Version: April 15, 2008

Meydenbauer Center Audio Visual Services & Price Guide. Provided by Audio Visual Factory Inc.

The Swingle Singers RIDER PART 1: TECHNICAL REQUIREMENTS A Cappella Show

Traktor Audio Configuration

TECHNICAL RIDER FESTIVALS 2015

Watford s Major Entertainment and Hospitality Venue

Stadsschouwburg Amsterdam Rabozaal website technical rider - 13th of may 2011

Site Plan. Parking. Main Auditorium. Large Auditorium. Lobby. Parking. Small Meeting Room. Dock & Broadcast Truck Bay


Media solutions and facilities for hire at the Bucks Media Centre

SOLUTION GUIDE AUDI TOR IUM. Audio Visual System Solutions for Business. HARMAN Professional Solutions Brands:

SOLUTION GUIDE CAFETERIA. Audio Visual System Solutions for Business. HARMAN Professional Solutions Brands:

technical rider & Stage plan

TECHNICAL INFOS CAPACITY 2 STAGE 2 TECHNICAL ROOF GRID (NOT YET AVAILABLE) 2 STAGE CURTAINS 3 FOLLOWSPOTS PLATFORM 3 ELECTRIC INSTALLATIONS 3

Theaters Tilburg - Concertzaal. Address

UCLA Department of World Arts and Cultures Glorya Kaufman Dance Theater (Room 200) Technical Information

Technical & Production information. Updated

Turbosound TMI- 102 (2 ways with 12" speaker) Turbosound TMI- 105 subwoofers QSC MX3000A amplifier. RCF 3000SM Crest 2800 amplifier EV SX200A active

Technical Specifications Version

Venue Information. Fritzclub im Postbahnhof Venue Information. FritzClub im Postbahnhof. Venue Adress. Straße der Pariser Kommune Berlin

Interactive System Audio-Visual Equipment and Event Management

Hire Equipment List. t: f: e: w: Ref. 2015/01

Av das Américas 5.300, Barra da Tijuca, Rio de Janeiro RJ Brasil. CEP:

One of the most incredible places on earth, Rolling Stone Magazine

Schouwburg & Filmtheater Agnietenhof Venue: 4000 AN Tiel. info@agnietenhof.nl techniek@agnietenhof.nl

Artist: Michael and Amy Rider: Corporate - Grand Pianos

SHUBERT THEATER 247 College Street, New Haven, CT

TECHNICAL SPECIFICATIONS Paramount website: Paramount

A1 Amplifier for 1x B2 Sub 750,00. D6 Amplifier 2-channel Digital 1850,00. EP1500 Amplifier 2x 450W/8ohm 135,00. PM1200 Amplifier 2 x 600W 275,00

NAZWA PRODUKTU. DJ/Pro Audio. Amplifiers PA. CD Player. Flightcases and Racks. Headset. Microphones DETAL BRUTTO ZŁ. Strona 1

DX12 & DX15 speakers Technical brochure

PLATFORMS - STAGING - CROWD BARRIERS

Special Events & Space Rentals

Understanding the DriveRack PA. The diagram below shows the DriveRack PA in the signal chain of a typical sound system.

venue hire Capacity 230 theatre style seating >> 250 seats >> 12 Trestle tables >> Lectern (by arrangement) >> Parking for 4 cars

KAY HOUSE DURYARD. There is also coffee room and a sound studio for recording live events in the upstairs spaces.

The Stagehand s Audio Handbook Book One

AUDIO SYSTEM SPECIFICATION

The new Gustave Eiffel Room On the 1st level of the Eiffel Tower

Craftsound prijslijst 2014

A/V and Video Conference Standards for Teaching and Learning Rooms.

THEATRE USER INFORMATION GUIDE

Event Planner/Venue Specialist Phone:

Booking Policies and Procedures

SYDNEY OPERA HOUSE (Bennelong Point) GPO BOX 4274 SYDNEY NSW 2001 AUSTRALIA

6 PAR 56 in front of dimmer (Please note that we don t have any free Channels on our dimmerpack)

THE MOST POWERFUL EON EVER

TECHNICAL RIDER HULK

L ORATORIO D AURELIA. Technical Rider. Administration: Didier Bendel Cell phone:(0049) (0) didierbendel@gmx.

The theatre cafeteria can provide snacks during the morning and coffee in the afternoon for 500 persons.

Lighting Inventory 2015

Tech Tips on how to plan a showing of Green Fire

Cole 100 Auditorium. Equipment Use Instructional Guide

Perth Concert Hall. Technical and Production Information

Audio engineering. on request Additional IR-receiver with headset 11,00 Radio set with headset 36,00. Lighting engineering (excl.

Brochure Event Production Suppliers Office Contact Sub Audio 2014

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

Blackline F12. portable club. Compact two-way passive system. features. applications

CENTER THEATER TECHNICAL SPECIFICATIONS 404 SEAT PROSCENIUM THEATER WITH FLY LOFT

Theatre Manager: Linda Aitken (03) ,

APPENDIX B. Exercises & Projects as stipulated in the Film Wing Syllabus, with resources required for each FIRST YEAR

Head of Creative Programmes Youth and Education Coordinator. Full time permanent contract. Probationary period: 6 months. Notice period: 3 months.

Mid-Range Complete Radio Station Package

MULTIPLE LINE ELECTRO-VOICE INSTALLATION A SURE SHOT AT DOC HOLLIDAY S COUNTRY BAR, ERIE, PA

VERSTERKERS ( Amplifiers )

CONCERT HALL TECHNICAL SPECIFICATIONS

SOLUTION GUIDE BOARDROOM. Audio Visual System Solutions for Business. HARMAN Professional Solutions Brands:

Main Library Meeting Room Use

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

CITY OF ENCINITAS LIBRARY ROOM RESERVATION APPLICATION

Auditorium Audiovisual System User s Guide

Elidy. The Led Scream. by chromlech

the audio/video + lighting menu

Transcription:

Technical Specification Town Hall Sebastian Petit Technical Manager Office DDI: +44 (0) 1494 552891 Email: techman@wycombeswan.co.uk Website: www.wycombeswan.co.uk Wycombe Swan Town Hall was built by Wycombe District Council and was leased in November 1992 to Wycombe Arts Management. The venue is an HQ Theatre. Wycombe Swan Town Hall is a presenting venue and as such has no scenic, properties or wardrobe construction workshops. Wycombe Swan Town Hall is a flexible venue that has a number of seating styles. Please call for further details. Generally Wycombe Arts Management will provide 2 technical staff for 4 hours for a get-in and fit-up and 2 technical staff for 4 hours per performance. Staffing requirements above this basic level will be recharged unless otherwise agreed. Please see Appendix I for full costs. 1. Auditorium Capacity Standing Room Theatre Style: Cabaret Style: Studio Style: 600 person capacity (end on raised or side on raised stage) 400 seats (end on raised stage only) 210 seats around 21 tables (end on raised stage only) 180 seats (flat stage with raked seating) 2. Stage Measurements General Measurements Full floor length Usable floor length Full floor width Usable floor width Height at highest point Height at lowest point Height of truss Height of truss at lowest point Height of low ceiling Height of load-in door Width of load-in door 26000mm/85 4 18500mm/60 9 16000mm/52 6 15000mm49 3 7900mm/25 11 5500mm/18 7270mm/23 11 3150mm/10 4 2300mm/7 6 2000mm/6 6 1400mm/4 6 2. Stage Sizes Theatre, Cabaret and Standing Style Studio Style Usable stage floor area Studio Style 7315mm/24 by 4876mm/16 @ 750mm/2 6 high 12801mm/42 by 7315mm/24 9144mm/30 by 7315mm/24 The rake used for Studio Style is constructed from SteelDeck units. 3. Stage Equipment 1 White Filled Cotton Cyclorama 10000mm/32 10 by 7000mm/23 12 12.5kg Stage Weights 8 Adjustable Stage Braces 4. Dance Floor 6 rolls of Harlequin reversible dance floor (black and white) 100 3 x3 blocks of Merricks-Sico parquet dance floor

5. Musical Instruments 1 Boston Baby Grand Piano 6. Access Equipment 1 large Tallescope 1 14 rung Zarges Skymaster ladder 7. Stage Management 3 Tecpro single ring beltpacks and headsets 8. Lighting Equipment 1 ETC Congo Junior lighting board c/w master playback wing & 2 x TFT monitors. 48 ways of Strand SD6 digital dimming 1 LightProcessor Q-Buffer 8 output DMX splitter 10 ETC Source 4 15/30 zoom profile 750W 240V 10 ETC Source 4 25/50 zoom profile 750W 240V 20 Strand Cantata Fresnel 1200W 240V 24 Thomas PAR64 PAR cans 1000W 240V 10 Drop-in iris for Source 4 6 gobo holders for Source 4 20 5m 15A TRS 20 10m 15A TRS All profile spotlights supplied with hook clamp, safety bond, shutters and colour frame. All Fresnel spotlights supplied with hook clamp, safety bond, barndoors and colour frame. All PAR s supplied with hook clamp, safety bonds and colour frames. We aim to hold all Lee colour filter from L002 to L212 in stock. Other colours and makes can be supplied but will be recharged. 9. Sound Equipment 1 Allen and Heath GL3300 24:8:2 channel mixer 1 Yamaha Q2031B graphic equaliser across L and R outputs 2 Yamaha Q2031A graphic equaliser across auxes 1 to 4 1 Yamaha SPX 90 1 Alesis QuadraVerb Plus effects unit 1 Drawmer DL441 Quad Compressor/Limiter 1 Drawmer DS404 Quad Gate 2 MDSJE330 MD player 1 Tascam CD player 4 JBL 4731A Full range loudspeakers 4 JBL 4745A Sub bass loudspeakers 2 FoH amp racks each containing 1 P7000 (sub) 1 SR606 (LF) 1 SR404 (HF) 1 Yamaha D2040 Channel Divider as crossover

10. Temporary Electrical Supplies 32A single phase supply for temporary sound located USR comprising of: 1 32A supply terminated in 32A/1ph BS EN60309-2 socket. Please note: there are no temporary supplies for lighting. 11. Dressing Rooms No. Location Accommodation Facilities A stage level 6 persons WC, shower, TV point, internal telephone B stage level 6 persons WC, shower, TV point, internal telephone Appendix I 1. Staff Costs Staff numbers over and hours worked above the contractually agreed levels will be recharged. Sunday getins, work on a Statutory Holiday, between the hours of midnight and 8am and work resulting in the loss of a compulsory meal break will be charged at double time. All part hours excepting TMA get-out hours are rounded up to the nearest hour. Minimum call for technicians is 4hrs. Position Cost per hour Technical Manager 17.00 Senior Technicians 15.00 Technicians 13.00 Followspot Operators 13.00 Wardrobe and Wigs Staff 13.00 Stage Door Keepers 13.00 Riggers 50.00 per point These costs are exclusive of National Insurance (currently 12.8%) or Valued Added Tax (currently 17.5%). Wycombe Swan operates a policy of multi-skilled working and therefore all technicians will work interdepartmentally as required. 2. Other Contra Costs Item Cost Piano tuning (Monday to Friday) 90.00 (Evenings 100.00) Piano tuning (Saturday and Sunday) 150.00 Get-Outs (as per BECTU/TMA agreement) 81.62 per man for the first two hours (minimum call) 40.78 per man per hour after that in ½ hr increments Appearance fee 7.60 per show (or current TMA/BECTU rate) TV Premium 1 extra hour per technician per hour or part-hour s filming Laundry If toured washing machines/driers are installed there is a weekly charge of 25.00 per machine Dancefloor 100.00 These charges are exclusive of Valued Added Tax (currently 17.5%) Wycombe Swan is happy to provide ironmongery, timber, tape, colour filter or any other item that a Visiting Company may need to ensure that the production is successful. This is undertaken on the understanding that the costs for procurement of said items will be added to the Technical Recharge.

3. Items for Hire Item Cost 1500 ANSI lumens projector 150/day 3000 ANSI lumens projector 200/day DMX projector shutter 20/day 10 x 6 FastFold screen 60/day 12 x 8 6 FastFold screen 70/day DVD player 30/day VHS player 30/day Lavalier radio mic Costed per hire (Minimum 2 weeks notice) Hand-held radio mic Costed per hire (Minimum 2 weeks notice) 125amp 3 ph - 30a+16a distro 40.00/day, 120.00/week These charges are exclusive of Valued Added Tax (currently 17.5%) Please call the Technical Manager on (01494) 552891 for weekly hire costs. Wycombe Swan is happy to hire in any other equipment as required by the Visiting Company. These costs will be added to the Technical Recharge. Hires must be requested in good time. Appendix II 1. Shared Stage Equipment 7 of 8 x 4 SteelDeck 3 of 8 x 4 Maltbury SteelDeck 20 of 8 x 3 SteelDeck 12 of 6 x 4 SteelDeck 6 of 6 x 3 MetroDeck 3 of 3 x 3 MetroDeck 16 of 4 SteelDeck handrails 8 of 3 SteelDeck handrails 2. Shared Lighting Equipment 1 Le Maitre G150 smoke machine 8 10m Socapex 10 15A plug to Socapex spiders 4 Socapex to 15A socket break-out boxes (Socapex thru type) 4 Socapex to 15A socket spiders 3. Shared Sound Equipment 1 Yamaha MG10/2 mixing desk 1 Yamaha MG12/4 mixing desk 2 JBL Control 12 speakers c/w spigot and stand 1 C-Audio SR404 amplifier 10 Shure SM58LC dynamic vocal microphones 2 Shure SM58SLC dynamic vocal microphones 5 Shure SM57LC dynamic instrument microphones 5 Shure PG56 dynamic drum microphones 1 Shure PG52 dynamic bass drum microphone 1 AKG D112 dynamic bass drum microphone 6 AKG C451E condenser instrument microphones 2 Audio Technica AT45 choir microphones 1 AKG HM1000 choir microphone 2 Crown PCC160 microphones 2 EMO Dual passive DI boxes 8 EMO Single passive DI boxes

1 BSS AR416 4 channel active DI 8 Martin LE400C passive monitors (15 driver, 2 horn) 4. Shared Rigging Equipment 30 8m black steels SWL 432kg soft eye both ends 10 1m 1tonne round slings 4 2m 1tonne round slings 4 3m 1tonne round slings Various Crosby shackles including ½tonne, ¾tonne, 1tonne, 2 tonne and 3¼tonne SWL s Please contact the Technical Manager on (01494) 552891 for details of what equipment is available for a specific date. Wycombe Swan will try to accommodate the Visiting Company s wishes but with the shared stock, allocations can only be made on a first come, first served basis. Wycombe Swan apologises for any inconvenience that this may cause. Appendix III ALL ELECTRICAL EQUIPMENT BROUGHT IN BY THE VISITING COMPANY MUST CONFORM TO BS7671:2001 AND MUST COME COMPLETE WITH A CURRENT AND VALID PORTABLE APPLIANCE TEST CERTIFICATE EVEN IF IT IS HIRED FROM A THIRD PARTY. ALL CONNECTIONS TO TEMPORARY ELECTRICAL SUPPLIES WILL BE CARRIED OUT BY WYCOMBE SWAN TECHNICAL STAFF ONLY. ALL RIGGING EQUIPMENT MUST COMFORM TO THE LIFTING OPERATIONS AND LIFTING EQUIPMENT REGULATIONS AND COME COMPLETE WITH A VALID AND CURRENT TEST CERTIFICATE EVEN IF IT IS HIRED FROM A THIRD PARTY. THE IN-HOUSE RIGGERS WILL OVERSEE ALL RIGGING OPERATIONS. WYCOMBE ARTS MANGEMENT AND ITS EMPLOYEES HAVE THE RIGHT TO REFUSE TO USE ANY EQUIPMENT THAT IS DEEMED UNSUITABLE FOR THE TASK INTENDED. THE TECHNICAL DEPARTMENT MUST RECEIVE ALL TECHNICAL REQUIREMENTS IN THE FORM OF A RIDER AT LEAST THREE WEEKS PRIOR TO THE EVENT. THIS MUST INCLUDE, AS A MINIMUM, GET-IN TIME, STAFF REQUIREMENTS, EQUIPMENT REQUIREMENTS, LIGHTING AND GROUND PLANS, RISK ASSESSMENT AND SPECIAL EFFECT LICENSE REQUIREMENTS. WYCOMBE ARTS MANAGEMENT RETAINS THE RIGHT TO ADJUST SOUND LEVELS IF THOSE LEVELS ARE DEEMED TO BE IN CONTRAVENTION OF THE NOISE AT WORK REGULATIONS. PLEASE NOTE THAT WHEN THE TECHNICAL SPECIFICATION IS INCLUDED AS PART OF THE CONTRACT IT IS A LEGALLY BINDING DOCUMENT. BY SIGNING THE CONTRACT THE VISITING COMPANY S MANAGEMENT ARE AGREEING TO THE RESTRICTIONS AND COSTS DETAILED HEREIN. Date of this revision: January 2010. This document will be updated on a month by month basis. 2010 Wycombe Arts Management. All information contained in this document is subject to change without notice. Errors and omissions excepted.