FIRE SPRINKLER SYSTEMS

Similar documents
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Automatic Fire Sprinkler Submittal Requirements

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

C I T Y O F S E L M A F I R E D E P A R T M E N T

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

Clark County Fire Prevention

CHAPTER 9 FIRE PROTECTION SYSTEMS

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

How To Install A Carbon Monoxide Detector

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Roland Garcia Pearland Fire Department

CITY OF YORBA LINDA P.O. BOX CALIFORNIA

BUILDING SAFETY UNIT

General Fire Code Requirements Within Commercial Tenant Spaces

Fire and Emergency Medical Services (EMS) Responders

Fire Alarm System Plans Review Checklist Property location Date of Review

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

BUILDING PERMIT APPLICATION APPLICABLE TO CITY LIMITS AND ETJ CHAPTER 18, General

MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Fire Alarm Systems Permit Packet. City of Greer Fire Department

FIRE SUPPRESSION INSTALLATION CITY OF HARRISONBURG, VIRGINIA

NFPA FAQs. 3. Can plastic pipe be used on a sprinkler system complying with NFPA 13?

Building Code Clarifications - 7. Fire Resistance

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

Safety, Health and Accessibility Design Guidelines For Architects, Engineers and Design Firms

Basic Requirements for Residential Plan Review _

AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

FIVE YEAR CERTIFICATION REPORT

Fire Alarm Systems Requirements by Occupancy Type

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

FIRE ALARM PLAN REVIEW. Office of the State Fire Marshal Massachusetts Department of Fire Services December 2009

City of Bettendorf Fire Alarm System Requirements

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

Indiana Building Rehabilitation Standard

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

Bold items are particular to the City of Euless

HERNANDO COUNTY FIRE ALARM GUIDELINES

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Concord Department of Fire and Life Safety FIRE MARSHAL S OFFICE

SACRAMENTO VALLEY FIRE MARSHALS ASSOCIATION

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

Fraternity and Sorority House Fire Safety

FIRE ALARM SYSTEM PLAN SUBMITTAL CHECKLIST

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Construction Permit Application Instructions Instructions for completing Construction Permit Applications and Technical Sections are as follows:

Fire Protection Coffee Break Training August 2014

Department of Community Development, P. O. Box 427, Herndon, Virginia

Single Family Residential Basement Finish

CERTIFICATE OF COMPLIANCE

County of San Diego, Planning & Development Services SECOND DWELLING UNIT

EXPRESS PERMITS (No Plan Check Required)

Chapter 19 - FIRE SPRINKLER SYSTEM INSPECTIONS

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY (518) /

New York City 2014 Building Code Fire Protection Revisions. Presented by John Bower

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

Building and Other Permits Fee Schedule Effective Date: July 1, 2016 BUILDING PERMIT FEE

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIRECTOR'S OFFICE

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

Code Requirements for Existing Buildings

The City of Basehor, Kansas

SUBCHAPTER 17 FIRE ALARM, DETECTION AND EXTINGUISHING EQUIPMENT

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

city of edmonds development information

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

Commercial Fire Inspections

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

Development Services Guidelines

2013 BUILDING ENERGY EFFICIENCY STANDARDS

Building Permit, Fire Inspection and Operating Permit Fee Schedule

CHAPTER 7 BUILDING ARTICLE 7-1 UNIFORM CODES Adoption. Board of Appeals. Annual Review

BUILDING PERMITS. Santa Rosa County Building Inspection

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

PLAN SUBMITTAL REQUIREMENTS FOR KITCHEN HOOD AND DUCT EXTINGUISHING SYSTEMS

FIRE-FIGHTING DESIGN BRIEF REPORT

TOWN OF ORO VALLEY AMENDMENTS TO THE INTERNATIONAL BUILDING CODE, 2012 EDITION

A. Fire Protection Plan. B. Access and Parking

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

COMMONWEALTH OF MASSACHUSETTS STATE BUILDING CODE 780 CMR, 6 th Edition FIRE PROTECTION SYSTEMS CHAPTER 9

Transcription:

Page: 1 6 This Standard is promulgated pursuant to the Novato Fire Protection District amendments to the Uniform and California Fire Codes regarding the requirements for automatic fire sprinkler systems. For alarm monitoring requirements reference Novato Fire Protection District Standard 400. I. Permits and Plans A. A Fire District Permit application shall be obtained for all fire protection and extinguishing systems. Separate permits and submittals are required for overhead and underground systems. Exception NFPA 13D systems for residential shall not require a separate underground permit. The Permit application shall be completed and plans reviewed prior to installation. Contact the Novato Fire District Administrative Office at (415) 878-2690 for permit applications. B. Plans shall be submitted as follows. At least three (3) sets architectural or engineered blue line drawings shall be accompanied by three sets calculations and material specification sheets for piping, fittings, and sprinkler heads. C. See Novato Fire Protection Standard 402 for underground permits and plan submittals. II. One and Two Family Dwelling Units A. Buildings that are intended for occupancy as a one or two family dwelling unit shall have an automatic residential fire sprinkler system installed in accordance with most recent published edition National Fire Protection Association Standard 13D with the following modifications: 1. Control valves and riser shall be installed as shown in Figure 1. 2. A remote inspector test valve is required at the furthest remote portion the system. 3. Pilot heads shall be installed in the attic spaces directly above every attic access opening. 4. All garages shall be sprinkled. 5. A sprinkler head box shall be installed in every unit near the main sprinkler riser and shall include at least one head each type installed, a sprinkler head wrench, and a water key to test the remote inspector test valve. 6. A durable and permanent sign shall be installed at the test valve stating Inspector Test Valve. 7. All rooms with useable and accessible space under stairs shall be sprinklered regardless 13D exceptions.

Page: 2 6 III. One and Two Family Dwellings Greater than 6,000 Square Feet A. Any Group R Division 3 Occupancy as defined by the California Building Code in excess 6,000 square feet, shall have an automatic residential fire sprinkler system installed in accordance with most recent published edition National Fire Protection Association Standard 13R with the following modifications: 1. A remote inspector test valve is required at the furthest remote portion the system. 2. Pilot heads shall be installed in the attic spaces directly above every attic access opening. 3. All garages shall be sprinkled. 4. A sprinkler head box shall be installed in every building near the main sprinkler riser and shall include at least one head each type installed, a sprinkler head wrench, and a water key to test the remote inspector test valve. 5. A durable and permanent sign shall be installed at the test valve stating Inspector Test Valve. 6. All rooms with useable and accessible space under stairs shall be sprinklered regardless 13R exceptions. B. Any permissible reductions in fire flow stipulated by Uniform and/or California Fire Codes shall not be applied unless approved by the Fire Marshal and the entire building is fully sprinkled including those areas exempted by NFPA 13D and 13R. Such cases may be approved by the Fire Marshal. IV. Hotels/Motels and Apartment Buildings A. Buildings that are intended for occupancy as a Group R Division 1 Occupancy as defined by the California Building Code, shall have an automatic residential fire sprinkler system installed in accordance with the most recent published edition National Fire Protection Association Standard 13R with the following modifications: 1. A remote inspector test valve is required at the furthest remote portion the system. 2. Pilot heads shall be installed in the attic spaces directly above every attic access opening. 3. All garages shall be sprinkled. 4. A sprinkler head box shall be installed in every building near the main sprinkler riser and shall include at least one head each type installed, a sprinkler head wrench, and a water key to test the remote inspector test valve. 5. A durable and permanent sign shall be installed at the test valve stating Inspector Test Valve.

Page: 3 6 6. All rooms with useable and accessible space under stairs shall be sprinklered regardless 13R exceptions. B. Any permissible reductions in fire flow stipulated by Uniform and/or California Fire Codes shall not be applied unless approved and the entire building is fully sprinkled in accordance with NFPA Std. 13. Such cases may be approved by the Fire Marshal. In any case, the available fire flow shall not be less than 1,500 gallons per minute. Additional gpm may be required based on building type construction and total floor area. V. All Commercial Structures A. An automatic fire sprinkler system shall be installed in all the following in accordance with the most recent published edition NFPA Std. 13: 1. Every newly constructed, freestanding building or facility. 2. In newly created attached second dwelling units. 3. In all buildings which has more than fifty per cent (50%) floor area added or any substantial remodel as defined in this standard, within any 12-month period. The Chief may grant exceptions when alternate means protection are installed as approved by the Chief. 4. In all buildings except R-3 occupancies, in excess 3,000-sq. ft. which have more than ten per cent (10%) floor area added within any 12-month period. The Chief may grant exceptions when alternate means protection are installed as approved by the Chief. 5. In all existing buildings, where fire sprinklers are required by provisions this code, they shall be extended into all unprotected areas the building in accordance with standards developed by the Chief. 6. All public storage facilities shall be provided with an automatic fire sprinkler system. All public storage facilities shall have an approved wire mesh barrier installed 18" below the deflector within each storage room to limit storage height and for proper sprinkler coverage. Exceptions: 1. Free standing Group U Occupancies not more than 1,000 square feet and provided with exterior wall and opening protection as per Table 5-A the Building Code. 2. Agricultural buildings as defined in Appendix 3 the Building Code and not exceeding 2,000 square feet, having clear unobstructed side yard combustible materials, exceeding 60 feet in all directions and not exceeding 25 feet in height,

Page: 4 6 and located within an Agricultural zoned district as defined in the Marin County Planning Code. 3. Any permissible reductions in fire flow stipulated by Uniform and/or California Fire Codes shall not be applied unless approved and the entire building is fully sprinkled in accordance with NFPA Std. 13. Such cases may be approved by the Fire Marshal. In any case, the available fire flow shall not be less than 1,500 gallons per minute. VI. Fire Sprinkler Zones and Control Valves A. In mutli-story buildings and/or where standpipe outlets are required, automatic fire sprinkler systems and combination systems shall be zoned by floor. Control valves shall be capable isolating the system by floor and monitored for supervision. Water flow switches shall be provided to alarm by building and by floor. Standpipes and standpipe-fire sprinkler combination systems shall have separate system (monitored and supervised) control valves capable isolating the standpipe systems by building and by floor. All alarm monitoring and supervision shall comply with Novato Fire Protection Standard #400 and be issued a serially numbered U.L. certificate. Exception: Fire sprinkler systems conforming to NFPA 13D for single family dwellings need not comply with this section. VII. Fire Flow Requirements A. Minimum fire flow requirements in addition to the requirements the California Fire Code and Novato Fire District Ordinance 2002-1 shall be as follows: a) Minimum fire flows serving commercial projects and apartment buildings shall be not less than 3,500 gpm b) Minimum fire flows serving residential occupancies in the designated UWI areas the Novato Fire District shall be not less than 1,700 gpm. c) Minimum fire flows serving single family dwellings not in the designated UWI areas the Novato Fire District shall be not less than 1,000 gpm B. Fire flows may be increased depending on building square feet and type construction. Credits for fire flow may be granted by the Fire Marshal on a case by case basis and when approved alternate means protection are provided. Alternate means protection may include but not be limited to: Buildings completely fire sprinkled throughout regardless standard exceptions; Installation wet standpipe systems in accordance with NFPA Stds. and this Standard; Increased fire resistive construction when not used as credit for allowable building area or height increases and where it is not already required by the CBC or CFC; Monitored automatic fire detection and/or

Page: 5 6 extinguishing systems in accordance with NFPA Stds. and Novato Fire Protection Standard 400. VIII. Substantial Remodel Defined A. Substantial Remodel shall mean the renovation any structure, which combined with any additions to the structure, affects a floor area, which exceeds fifty percent the existing floor area the structure. When any structural changes are made in the building, such as walls, columns, beams or girders, floor or ceiling joists and coverings, ro rafters, ro diaphragms, foundations, piles or retaining walls or similar components, the floor area all rooms affected by such changes shall be included in computing floor areas for purposes applying this definition. This definition does not apply to the replacement and upgrading residential ro coverings. Example calculation: Total base initial existing walls 1232 feet 50% base = 616 feet Walls removed Walls added Walls altered 281 feet 312 feet 593 feet The total walls altered is less than 50% the base, therefore, sprinklers are not required. IX. System Hydraulic Calculations A. All hydraulic calculations shall reflect a 10% cushion factor at the end the total system pressure calculation. B. Residential systems serving only one house shall use an additional 5gpm in the system calculation from the domestic point connection at the house if a lawn irrigation system is also installed at the site. C. If because pressure in the main is not adequate, a pump is designed to serve the system, calculations, pump specification and drawings shall be included in the submittal. The pump shall serve the domestic and fire sprinkler systems.

Page: 6 6 Figure 1