Every One an Expert. evol xr.

Similar documents
Extraction to Injection in a Single Process

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Syringes 5. Contents. Autosampler 6. MEPS 18 Product Data 18 Part Numbers 19. Manual 20. Guided Plunger 24 Product Data 24 Part Numbers 25

ORGANIC SAMPLE PREPARATION

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Purification of reaction mixtures using flash chromatography.

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Innovative vs Traditional

GC-xt. The most flexible GC /GC-MS liquid sample injector

How To Test For Contamination In Large Volume Water

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Opiates in Urine by SAMHSA GC/MS

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Paper Chromatography: Separation and Identification of Five Metal Cations

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

A Complete Solution for Method Linearity in HPLC and UHPLC

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

SGE Syringe Selection Guide

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

The basic division explosives for forensic purposes is shown in Fig. 1

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Split / Splitless Injection for Capillary GC

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Oasis HLB Cartridges and 96-Well Plates

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

METHOD 8020A AROMATIC VOLATILE ORGANICS BY GAS CHROMATOGRAPHY

Gas Chromatography Liner Selection Guide

Fixed and Adjustable Spacing Electronic Pipettes

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

PRECISION LIQUID HANDLING

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

LC Application Note.

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Gas Chromatograph GC Consumables. p/n:

CERTUS NANO LIQUID DISPENSER FLUID MEETS PRECISION

Determination of polyols derived from sugars and residual sugars found in dry wines by means of gas chromatography (Resolution Oeno 9/2006)

Laboratory Biosafty In Molecular Biology and its levels

Overview. Purpose. Methods. Results

1 Four Robotic Platforms to Choose From. 2 Custom Solutions. 3 Do-It-Yourself Robotics

AUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Determination of Caffeine in Beverages HPLC-1

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation

Analysis of Liquid Samples on the Agilent GC-MS

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

SPE-TT. Tutorial Version Bruker BioSpin ; File: Tutorial 11 - SPE-TT; Version: ; By: Dr.

EnAlgae SOP: Biogas analysis

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

With proper calibration, the upper limit may be extended as needed.

PAPER CHROMATOGRAPHY

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

A Novel Approach to Low Volume Sample Preparation

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

EQuan MAX Getting Connected Field Service Guide

CORESTA RECOMMENDED METHOD N 72

Identification of Arson Accelerants by Gas Chromatography

Affi-Prep Protein A Matrix Instruction Manual

Automated Nucleic Acid Extraction WorkStation Faster, cleaner,

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Extraction of Caffeine from Energy Drinks

Key Words. Introduction

Your Personal Pipetting Robot

Transcription:

Every One an Expert evol xr Digital analytical syringe Speed up and simplify laboratory workflow Improve accuracy and reproducibility Standardize results independent of operator skill www.sge.com

evol xr Every One an Expert The World s First Digital Analytical Syringe evol xr is the coupling of two precision devices: a digitally controlled electronic drive and an XCHANGE enabled analytical syringe. Ergonomic, comfortable and easy to use. Suitable for use with volatile samples. Variable speed of operation. evol xr syringes are easily and quickly changed allowing them to be dedicated to individual liquids or methods to prevent possible crosscontamination of reagents. Easily calibrated by operators, and calibration factors saved for each syringe, enabling laboratories to comply with stringent global laboratory standards (e.g. GLP, GMP, FDA). Programmable and able to store a laboratory workflow (up to 98 steps). Password protection options enabling standardization of work processes. Inject directly onto a chromatography column with a consistent flow rate. evol xr syringe stainless steel needle enables direct injection through septa. Syringe Capacities to Suit a Range of Applications 5 µl, 50 µl, 100 µl, 500 µl, and 1 ml syringe capacities. Range of needle lengths and tips. Syringe Volume (µl) 1000 500 100 50 Volume Range of evol Syringes 50 µl Syringe 100 µl Syringe 500 µl Syringe 1 ml Syringe 2010 R&D 100 Award Winner 5 5 µl Syringe 0.1 0.2 1 2 5 10 20 50 100 500 1000 Dispense Volume (µl) Applications include: Preparation of calibration standards. Preparation and addition of internal standards. Precise dispensing of aqueous and nonaqueous liquids. Routine dispensing. Sample dilution. Ergonomic operation with substances in a fume hood. GC and LC Instrument injections. Eliminates the need for serial dilutions. Micro titrations. TLC spotting. FDA methods requiring a 1 ml syringe.

Improve Standard Laboratory Processes The award winning evol xr improves the pace of laboratory processes while delivering improved accuracy and reproducibility. Process Without evol With evol Benefits of Using evol Standard preparation Standards prepared in a large volume flask. From this standard aliquots are individually dispensed into autosampler vials. Standards are made up directly in the vial, including the make up solvent. Less glassware usage. Reduces waste fluid. Significant time saving. Improved accuracy and reproducibility. Addition of standards Small amounts of standard aspirated and dispensed into all samples before being transferred to an autosampler vial. One aspiration and a fast series of repeated accurate dispenses directly into vials. Significant time saving. Improved accuracy and reproducibility. Delivery of derivatization agents Laboratory staff required to work in a fume hood with potentially hazardous materials, to prepare combinations of derivatization agents in open vials. Process completed with evol programmed to aspirate an amount of solvent or agent and then dispense aliquots into sealed vials, Single handed operation. Improved operator safety, lower spill and splash risk. Ergonomic benefits behind fume hood screen. Improved accuracy and reproducibility. Less glassware use. Serial dilutions Transfer of a small amount of solution to another container. Solvent added to achieve the required volume. This is repeated multiple times to obtain the required final accurate concentration. One aspiration of the solution can be dispensed directly into the solvent to achieve the required accurate concentration. Complete workflow simplification. Significant time savings. Improved accuracy. Less solvent required. Less glassware used. evol xr Starter Kit Use evol xr to avoid problems with pipettes and dispensing organic solvents.

evol xr Every One an Expert evol xr for NMR Designed for the Specific Needs of Nuclear Magnetic Resonance Spectroscopy evol xr NMR long stainless steel needles, enable in-tube sample dilution and mixing, and recovery of samples facilitating re-use of NMR tubes. Suitable for small sample quantities. Very high levels of accuracy and reproducibility. Can be used with specialist samples and solvents. Conserves high cost consumables. Configuration for NMR evol syringes and needles are available separately. 5 µl, 50 µl, 100 µl, 500 µl, and 1 ml syringe capacities. 115 mm and 180 mm needle lengths. Bevel or cone needle tips. Needle lengths of 115 mm and 180 mm for NMR. Volume Range of evol Syringes for NMR Syringe Volume (µl) 1000 500 100 50 100 µl Syringe 50 µl Syringe 500 µl Syringe 1 ml Syringe 5 5 µl Syringe 0.1 0.2 1 2 5 10 20 50 100 500 1000 Dispense Volume (µl)

Saving NMR Capillaries evol xr allows accurate manipulation of small volumes of NMR samples enabling dilution directly in the analysis tube even in tubes with the smallest internal diameters. Precious samples can be easily recovered to store in alternative vessels (such as inexpensive vials) rather than being left in valuable tubes. These tubes can now be emptied using evol xr for washing and re-use. evol xr Starter Kit for NMR Suitable for small quantities of precious NMR samples. NMR Laboratory Experience With evol xr evol xr is used at France s Laboratoire de Résonance Magnétique Nucléaire, Institut de Biologie Structurale (LRMN, IBS) with positive results. During method development the laboratory tests a large number of samples with high repetition. The screening procedures use very small sample volumes and involve titration of samples directly in NMR tubes. The laboratory has been impressed with evol xr which has provided improved accuracy and decreased sample handling time. We use evol for the preparation of multiple low-volume NMR tubes in parallel. evol is reliable, accurate and practical for titrations and filling tubes with small diameters. evol is easy and fast to use and dispenses samples accurately. Jérôme Boisbouvier - LRMN, IBS, Grenoble, France.

evol xr Every One an Expert evol xr for MEPS Enabling MEPS Automation MEPS is Micro Extraction by Packed Sorbent, the miniaturization of conventional SPE packed bed devices from milliliter bed volumes to microliter volumes. The MEPS approach to sample preparation is suitable for reversed phases, normal phases, mixed mode or ion exchange chemistries. MEPS advantages over conventional SPE: Less sample required giving you greater flexibility when you have small sample quantities. Less solvent used means less solvent waste and ultimately reduced expense. Faster preparation time, reducing from hours to minutes for improved laboratory workflow. MEPS incorporates packed phase in a micro-cartridge or BIN (Barrel Insert and Needle) which is then integrated into an SGE analytical syringe to make miniaturized SPE possible. With MEPS, the sample processing, extraction and injection steps are performed using the same syringe. Together, evol xr with MEPS offers improvements in workflow and resource savings. evol custom programming enables MEPS to be semi-automated, reducing errors, and improving reproducibility. Configuration for MEPS MEPS BINs are available for use with evol MEPS syringes, with C2, C8, C18, Amino-Propyl Silane phases, for LC and GC applications. MEPS BINs can be used with 50 μl, 100 μl and 500 μl evol MEPS syringes. LC needles are 55.5 mm in length, 22 gauge and LC tipped. GC needles are 55.5 mm in length, 23 gauge and cone tipped. Volume Range of evol Syringes for MEPS Syringe Volume (µl) 1000 500 100 100 µl Syringe 500 µl Syringe 50 50 µl Syringe 5 0.1 0.2 1 2 5 10 20 50 100 500 1000 Dispense Volume (µl)

Condition Reuse MEPS between 40-100 times (dependent on matrix) Load Repeat load Small sample volumes Small volume solvent required evol MEPS Applications Use evol xr MEPS for sample preparation, SPE method development, sample cleanup and proofing before transition to fully automated platforms. Quickly process small sample batches, or urgent samples. Suitable for a range of analyses: Environmental, e.g. Determination of organic priority pollutants and emerging compounds in wastewater and snow samples. Forensics, e.g. Contribution of micro-extraction in packed sorbent for the analysis of cotinine in human urine by GC-MS. Elute Inject the analyte directly into the injector Wash Remove unwanted analytes Ensure high recoveries How to use evol xr with MEPS Pharmaceutical, e.g. Liquid chromatographic analysis of oxcarbazepine and its metabolites in plasma and saliva. Food and Flavor, e.g. Determination of 2,4,6-trichloroanisole and 2,4,6-tribromoanisole in wine. Life Sciences, e.g. Rapid and sensitive method for determination of cyclophosphamide in patients plasma samples. Extraction Comparison of LLE, SPE and MEPS Description Liq-Liq Extraction Liq-Solid Extraction MEPS Extraction Concentration of sample 5 ng/ml 5 ng/ml 5 ng/ml Extraction volume 1000 ml 20 ml 1 ml Volume of solvent used 150 ml DCM 3 ml DCM 0.04 ml DCM Concentration in solvent 33.33 ng/ml 33.33 ng/ml 125.00 ng/ml Final volume of extract 1 conc vol (ml) 0.2 conc vol (ml) NO CONCENTRATION Concentration in final volume 5000 ng/ml 500 ng/ml STEP REQUIRED Injection volume 1 µl inj 2 µl inj 2 µl inj Concentration of injection volume 5 ng per µl 0.5 ng per µl 0.125 ng per µl Concentration injection on column 5 ng 1 ng 0.25 ng Approx. time to prepare Extraction to injection ~ 2-3 hours Extraction to injection ~ 40-60 min Extraction to injection ~ 5-10 min Approx. volume of waste generated Waste generated ~1+ Liter Waste generated ~50 ml Waste generated <2 ml MEPS reduces solvent use and waste.

evol xr Every One an Expert SGE Analytical Science (SGE) is a world renowned brand for components and consumables used in scientific analysis. Primarily in the field of scientific glass engineering for liquid handling and separation science, since its beginnings in 1960, SGE has become the global market leader in niche areas such as autosampler syringes and GC inlet liners. Completing the transition into Trajan after acquisition in 2013, SGE products make up a solid foundation of Trajan s portfolio and will continue to be created and supported by Trajan customer service and distribution networks worldwide. For more information visit www.sge.com or contact techsupport@sge.com. Approved Distribution Partner BR-0412-S_RevF Trajan Scientific and Medical 04/2015