PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation
|
|
|
- Buck Lawson
- 10 years ago
- Views:
Transcription
1 PURIFICATION Preparative Chromatography Modular Solutions from Manual Systems to Full Automation PREPARATIVE CHROMATOGRAPHY SOLUTIONS Lab scale Scale Up Reverse Phase Medicinal Chemistry Natural Products Peptides Chiral Oligonucleotides Impurity Isolation Normal Phase Small molecules
2 PLC 2020 Purification System LC out of the Box! Fully-functioning purification system, the PLC 2020 Personal Purification System features: Compact footprint Easy-to-use The PLC 2020 Personal Purification System is ideally suited for low-throughput, high pressure purification needs and is intended to support an individual or a small group of chemists. Wide Range of Purification Modes Multigrams range High Pressure Reverse Phase Normal Phase Chiral Low Pressure Flash Solid Injection Capability Save time High Pressure Purification brings more resolution with no need to purify multiple times to achieve required purities. Running the System Simple as 1 Tap Run on the main menu 2 Select Method & tap Run 3 Load & inject sample 2 A robust system true to its name to last through the years
3 Easy-to-Use Software Intuitive interface. Test tubes 13 x 100 mm (240) 15 x 45 mm (144) 16 x 100 mm (132) 16 x 150 mm (132) 18 x 150 mm (132) Fraction Capacity (3 Racks) Scintillation vials 20 ml (42) 40 ml (42) Custom racks available Storage for up to four 4L solvent bottles. NEW! PLC 2020 Purification System Real-time, graphical gradient modifications. Real-time sample tracking during run. Conditional logic fraction collection based on two detector channels using any combination of Slope and/or Level. Auto-Print and Auto-Export of reports at the end of a run. Integrated touch screen control. Column holders for FLASH & Reverse Phase columns. Accommodates any FLASH style cartridge as well as dry load configurations. Monitor the progress of the system, run lights illuminate the racks during a run and flash if an error has occurred. Automatic repetitive injection with external pump to increase purification throughput. 3 rack positions dedicated to fractions. Interchangeable pump head design to accommodate wide flow rate and pressure range. 3 USB ports for easy download/upload methods and results. Easily connect your printer, keyboard and mouse. Selection of up to 4 solvents. The purification throughput is highly related to compounds solubility, matrix complexity and column resolution. PLC2020 Overview Low Pressure High Pressure Column Type # NP Flash Cartridge C18 Flash Cartridge HPLC Column Size g g mm ID mm ID mm ID Flow Rate ml/min ml/min ml/min ml/min ml/min. Loading Capacity g g Up to 0.5 g Up to 2 g Up to 6 g Injection Volume > 10 ml and solid injection 2-10 ml ml ml >10 ml Pressure < 100 psi psi Calculation based on Methanol/Water solvents - 5 µm column 150 to 250 mm length 3
4 Analytical to Preparative HPLC System Gilson High Performance Liquid Chromatography (HPLC) systems provide complete solutions for all purification needs. Front-end liquid handlers and autosamplers are available in a range of bed capacities and optimized bench space footprints. GX Series Platforms The GX series platforms feature a selection of bed capacity adapted to the users needs. Allow injection and Fraction Collection on the same instrument bed. The revolutionary GX Solvent system accommodates sample volumes ranging from microliters to hundreds of milliliters. The GX series Liquid Handler offer numerous injection possibilities ranging from Analytical to Preparative. When size matters GX-281 & GX-271 Bed Capacity Tube Diameter GX-281 Sample Quantity GX-271 Sample Quantity 10 mm mm mm mm mm mm mm mm The GX Series instruments features: GX series collection options Low Mount Fraction Collection Separate Injection and collection pathways. High Mount Fraction Collection Collection in closed vials and micro-plates. GX Z-Injection Module For fast injection with low carryover by aspirating the sample directly into the injection valve. Decreases cycle times. GX series Prep Solvent System Syringeless technology with access to five off-bed solvents. Injection volumes ranging from µl to 10s of ml. Multiple dilution and rinsing solvents. GX Direct Injection Module Innovative injection port design to reduce void volumes and minimize carryover associated. Possibility to combine two modules for analytical and preparative injection. 4 Perfect blend of performance, capacity and size...
5 Seamless Automation Unique Solutions Built On Specific Users Needs Because all our users have different needs and constraints, we do not have a one fits all solution but we build specific solutions that answer current and future needs of our users. Some of the solutions that can be offered: Columns Selection and Column Back Flush Columns selection for universal systems: Analytical method development and Scale Up to Preparative. Multiple purification modes (RP, NP, Chiral,...) Purification followed by direct analysis of fractions in analytical. Column Backflush. HPLC Purification System Fully Automated Samples Pre-Treatment and Injection Liquid handling and injection capabilities on the same instrument allowing multiple injections from the same sample, sample dilution, internal standard addition, sample cleanup by SPE,... GX-281 Preparative HPLC System GX-271 Semi-preparative HPLC System To Answer Solubility Issues Sandwich injection to avoid sample precipitation during the injection process: Unlimited injection volumes through solvent system and 1/8 injection loop. Direct Fractions Re-Injection The GX series platforms feature dual injection path allowing for analytical and preparative injections without compromises. The Trilution LC software can automatically inject the collected fractions for purity confirmation or for secondary purifications.... for mg to gram scale purification 5
6 HPLC Pumps Analytical, Semi-Prep, to Preparative Pumping Solutions Gilson offers unsurpassed flexibility in HPLC pumping systems with an extensive product range for all type of pumping applications. Capable of fast separations with high-efficiency columns in normal and reversed-phase modes, Gilson Pumps are the premier solvent delivery solutions for the analytical to preparative chromatography. Gilson dual-piston pumps for semi preparative and preparative chromatography feature high pressure mixing to guarantee gradient precision and reproducibility. Programmed Composition (% E) Gradient Linearity and Accuracy Time (minutes) Detected Composition (mau) Variable mixer and high pressure mixing solvents for optimized gradient performance. Solvent selection capable of up to 4 solvents per pump for a total of 8 solvents in a binary pumping system. mvolts Retention Time Repeatability Time (minutes) % Mobile Phase Series of Ten Injections Methyl PB Ethyl PB Propyl PB Average Retention Time Standard Deviation CV 0.72% 0.34% 0.29% Pump Overview 32x-H2 Analytical to Semi Preparative 331/332 Analytical to Semi Preparative 333/334 Analytical to Preparative Flow Rate ml/min ml/min ml/min. Flow Rate Accuracy 2% 2% 1% Pressure 4300 psi / 300 bars 8700 psi / 600 bars 3040 psi / 210 bars Column Types ID: 4.6 to 22 mm from 5 µm particles ID: 4.6 to 30 mm from 2.5 µm particles ID: 4.6 to 50 mm from 5 or 10 µm particles Typical Application Method development and purification up to 2 grams Method development, purification up to 6 grams and purity check on fast analytical column Scale up an purification up to 15 grams 6
7 HPLC Detectors From Analytical to Preparative Detection Solutions UV/VIS Detection 15X Series UV/VIS Detectors Rugged detectors operate in single wavelength or dual wavelengths mode. 171/172 Diode Array Detectors Accurate detectors with an optional remote flow cell design. Ideal for compounds identification (spectral library) and peak purity calculation. Specifications 15X detector Wavelength nm nm nm Diodes HPLC Purification System Flow Cell Selection Chart for Optimizing Sensitivity on 15X Series Detectors Selecting the correct flow cell will optimize sensitivity and peak shape. Analytical Flow Cell Semi-preparative Flow Cell Preparative Flow Cell Product # Internal Volume 12 µl 0.7 µl 0.16 µl Path length 5 mm 0.2 mm 0.05 mm Column Size 4 mm - 10 mm 20 mm > 40 mm Flow Rate 1 15 ml/min ml/min ml/min. Purify µg - 5 mg mg 300 mg - 15 g PrepELS II Detector The prepels II Detector is ideal for obtaining the purest fractions with the ability to detect virtually any analytes with or without a chromophore, including compounds that have poor UV absorption. Specifications Light Source 670 nm laser diode, < 5 mw Gas Requirement 65 ± 5 psi Nitrogen or Argon Evaporative Zone Temperature Ambient 120 C Nebulization Temperature 0 70 C Others Detectors Preparative Refractive Index Detector, Fluorimeter, Radioactivity, The Gilson 506 interface allows the collection of analogic signals (up to 4) to trigger fraction collection and for reporting. Mass Spec Single Quad Settings 7
8 LC/MS Purification System It s Your Chemistry... Simplified! Your time is valuable. The quality of your data is crucial. That s why Gilson has developed an LC/MS Purification System that is not only extremely easy-to-use and easy-to-maintain, but has one of the largest mass ranges on the market today. Your Specifications Modular design means each component can be configured to your specifications. Your Own Probe Just walk up and snap in to start, without worry of cross contamination in an open access, multi-user environment. Your Choice Choose to collect fractions using conditional logic based on any combination of UV, DAD, ELSD and up to seven MS Channels. Mass Based Purification Simple as: Select scan range Enter target masses and adducts Select conditional logic collection to trigger off both UV and MS RUN 8 Meeting the growing demand for...
9 NEW! LC/MS Purification System MS Detector Rugged & Simple Quick-connect Rugged and simple to maintain source allows for cleaning and maintenance without breaking vacuum limiting instrument down time and increasing productivity. Quick-connect feature allows each user to have their own probe, preventing contamination between users in open access environments. Multiple Mode Operation Automation & Calibration Ability to monitor in Full Scan, Extracted Ion and SIM (Selected Ion Monitoring) simultaneously. Integrated calibration vials for Auto-Tune allows for automated and effortless mass calibration. Range & Speed Source Features Mass Range 50 3,000 amu The source features XYZ adjustments of probe positioning to optimize spray in relation to the capillary entrance for higher flows and/or sample concentrations. Transparent window to easily view the spray. Scans Speeds up to 10,000 amu/ sec. Selective Collection of Compounds with Weak UV Response Immediately identify fraction of interest Sample tracking. Scan of the fraction collected. Real time access to MS spectra for each fraction collected. Gilson TRILUTION LC Software Conditional Logic Fraction Collection Purification Based on UV and MS Signals Fraction Tracking Function Split Ratio is Independent of Changes in The Hplc Flow HPLC HPLC 1 Stream Stream 1 Mass to be Mass to be Transferred Transferred HPLC HPLC Stream Stream 1 1 Mass Spec Spec Spec 3 Mass 3 Mass Stream Stream Mass Spec 3 Stream 3 Stream Aliquot Fill Allows for large, setable split ratio to allow the system to operate with a large flow range and column conditions. Mass Mass Active Splitter 4 4Transferred Transferred 2 2 Aliquot Transfer...simplified LC/MS based purification solutions 9
10 Trilution LC Software Gilson has redefined purification with the HPLC system control software, Trilution LC. This liquid chromatography software, specifically designed for purification, allows for complete control to achieve the challenging results that applications require. Configuration & Virtual Lab Screen Fraction Collection Simulator Full Hardware Control All aspects of the equipment are set in the Virtual Lab Screen. Graphical Method Creation Gradient profile. Hardware tasks. Fraction collection parameters. Fraction Collection Settings Advanced Fraction Collection Capabilities Collect by time, volume, level and slope. Individual parameter for front and back slope. Co-eluting peak. Collect non peak. Divide peaks by time or volume. Collect on different tubes for each injection or collect always in the same set of tubes in case of repetitive injections. Fraction Collection Optimization Change fraction collection parameters. Call a previous chromatogram. Check the fraction collection. Conditional Fractions Collection Set the collect on conditions from up to 8 channels. Select condition on AND, OR, AND/OR. Conditional Fraction Collection Screen 10
11 Control Software Sample Re-Injection Set Up Screen Application Run Screen Automatic Fractions Reprocessing Automatic sample list generation for post collection fraction processing such as pooling or re-injection. Automatic sample re-injection based on condition such as area size. Graphical Tracking of Sample & Fractions. Visual Operation List Auto sample list generation. Use of variables for easy scale-up from Analytical to Preparative runs. Real Time Viewing Real time chromatogram and fraction collection. Real Time Action Full access to all instruments during the run to: Change gradient profile. Activate fraction collection. Stop the pumps. Graphical Sample Tracking Identify fraction from chromatogram or injection vial. Open Access Module Administrator control & permission-setting capabilities. Walk-up user access. Apex: Collects the entire peak with subdividing at the Apex using a combination of slope settings and Apex throughput collection settings. Graphical tasks Drag-and-drop to specific time points for fast and easy method creation. Injection Task Fraction Collection Settings Task Start Fraction Collection Task Stop Fraction Collection Task Rinse Probe Task Detector Auto-Zero Channel Task Switch VALVEMATE Task 11
12 Fraction Collectors FC 203B/FC 204 Fraction Collectors Stand alone, compact Fraction Collectors. Collect by time, drop or peak in tubes, vials or microplates. 3-way diverter valve for collection by signal. Up to 10 programmable time windows can be added for collecting only samples of interest, while discarding the column s void volume, areas of non-interest and equilibration volumes. Contact closure inputs are available to remotely start, advance or stop fraction collection. Multi columns adapter up to 18 channels available. Specifications Dimensions (w x d x h) FC 203B: 32.4 x 29.2 x 26.7 cm (12.8 x 11.5 x 10.5 in) FC 204: 47.9 x 46.4 x 33 cm (18.9 x 18.3 x 13 in) Liquid Contact Material PTFE and 316 stainless steel Valve Switching Speed 100 ms Max Flow Rate FC 203B: 20 ml/min. FC 204: 20 or 200 ml/min. GX Fraction Collector in Closed Vials High mount fraction collection valve for fraction collection into microplates or into closed vials. HPLC Pumps 30X Series HPLC Pumps Stand alone 30X High Pressure Pumps can be used for: Repetitive injection of the same sample. Isocratic or Gradient pumping system. Up to 200 ml/min. with exchangeable pump head. Easy maintenance. The 306 model functions as a slave unit. The 305 and 307 Pumps are programmable through the incorporated keypad. Specifications Flow Rate 305/306: 10 μl/min. 200 ml/min. 307: 10 μl/min. 10 ml/min. Accuracy < ± 1% Reproducibility < 1% Dimensions (w x d x h) 33 x 33 x 15 cm (13 x 13 x 6 in) 12
13 Service Contracts Choosing a Maintenance Contract from your instrument manufacturer is an evidence of: Maximize Investments Increase longevity and reliability of equipment. Benefit of the expertise of the manufacturer for update. Control Costs Budget & plan maintenance. Preferential and attractive prices. Guarantee Quality Certified service engineers performing IQ/OQ. Comply with manufacturer specifications. Resources Services & Resources Gilson Publications Gilson HPLC Troubleshooting Guide Troubleshooting High Pressure Liquid Chromatography (HPLC) systems can be straightforward, despite the multiple components. With our guide that contains helpful forms and checklists, troubleshooting Gilson HPLC systems is simpler than ever! Included in this guide are real-life examples using HPLC systems with real problems and solutions organized into a spiral bound guide to eliminate problems that may be related to software, hardware, column, solvent, or any combination of these. Simple tests to prove purification and reduce or eliminate carryover are included! Technical Notes Handbooks Trilution LC v2.1 Fraction Collection Fundamentals. Methods for Verifying Fraction Recovery in Preparative HPLC Systems. Gilson Quarterly Application Notes Handbooks The complimentary quarterly Gilson Application Notes Handbook allows you to page through scientific advances using Gilson automation and Gilson pipettes in a number of different markets from other chemists and laboratories who have published applications. We welcome you to submit your application to us for publishing in our quarterly handbooks. Published applications offer everyone a chance to learn about the recent scientific highlights and new technologies. Attend our complimentary G.E.T. LIVE Web Seminars to learn about more scientific advances with industry leading applications and technologies from TODAY! Gilson is the host for our guest speakers, who lead the industry with their innovative methods and techniques. Contact [email protected] or visit to learn more. It s FREE! 13
14 Resources Optimizing Preparative HPLC There are numerous parameters and techniques to optimize preparative HPLC. Optimization will improve chromatography and percent recovery of collected fractions. Separation Scale-up Equations When scaling up from analytical scout runs to preparative purification the main parameters to scale up are: Flow Rate Fc2=Fc1 x D²c2 x Pc1 D²c1 Pc2 Fc1= Flow rate on column 1 (ml/min.) Dc1= Internal Diameter of column 1 (mm) Dc2= Internal Diameter of column 2 (mm) Pc1= Particle size of column 1 material (μm) Pc2= Particle size of column 2 material (μm) Injection Volume D²c2 x Lc2 Vc2 = Vc1 x D²c1 x Lc1 Vc1= Injection volume on column 1 (μl) Dc1= Internal Diameter of column 1 (mm) Lc1 = Length of column 1 (mm) Dc2= Internal Diameter of column 2 (mm) Lc2 = Length of column 2 (mm) Gradient Duration length preparative (diameter preparative) 2 flow rate analytical GD preparative = GD analytical x x x length analytical (diameter analytical) 2 flow rate preparative Pressure Equation In preparative chromatography the back pressure generated by the column and the various tubing can become a constraint. At constant mobile phase viscosity, the pressure drop can be estimated: Pc2 = Pc1 x Fc2 x Lc2 Pc1x Dc1 x( ) ² Pc1= Pressure on column 1 (psi) Pc2= Pressure on column 2 (psi) Fc1 x Lc1 Pc2x Dc2 Tubing & Column Back Pressure Tubing Back Pressure - for 1 meter length Pressure (psi/bar) Tubing ID (in/mm - Color coded) Flow (ml/min.) 0,005/0,13 - Red 0,010/0,25 - Natural 0,020/0,50 - Or 0,030/0,75 - Green 0,040/1,00 - Natural 1 695/48 43/ /60 55/4 11/ /9 24/ /22 65/5 20/ /7 30/2 Typical Volume (μl) Basic Column Back Pressure - Solvent: Methanol/Water - Solid phase: C18-5 μm Pressure Column ID (mm) Column Length (mm) 4, psi / 130 bars psi / 213 bars Typical flow (ml/min.)
15 Concentration Overloading on PLC2020 Saturation of solid phase from on column front change peak shape. Late eluting peak is accelerated by earlier co-eluting compound. Resources Solid Injection on PLC2020 FLASH FLASH Dry Load Run Method - FLASH Dry Load To FLASH Waste Waste Mobile Phase To FLASH Mobile Phase Detector Detector Automatic Purity Checking on Gilson System Advantage of dual injection paths and high pressure pumps for analytical and preparative works: Gilson Preparative Solutions: Automatic Re-injections on short column for purity check Pumping System Type Column Flow Pressure Quantity Purification 30 x 250 mm - 5 μm 45 ml/min. 230 bars Up to 6 g 331/332 Purity check 2,1 x 50 mm - 2,7 μm 0,8 ml/min. 430 bars Inject several milliliters or do multiple injections on a preparative column. Then automatically switch to a very selective short analytical column and inject few microliters to quickly check purity of collected fractions. Pure fractions can be pooled to reduce evaporation time. 15
16 Gilson International B.V. Laan van s-gravenmade AJ DEN HAAG The Netherlands Gilson International B.V. Specifications subject to change without notice.
IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.
IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
Purification of reaction mixtures using flash chromatography.
Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?
High-Throughput 3-D Chromatography Through Ion Exchange SPE
High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample
Smartline HPLC by design
HPLC SMB Osmometry Smartline Systems Smartline HPLC by design Smartline high performance liquid chromatography instruments are designed to provide reliable separation solutions for routine tasks such as
Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation
Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA
How To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
Product Guide www.gilson.com Gilson, Inc. World Headquarters Gilson S.A.S.
Product Guide Gilson, Inc. Since the 1940 s, the Gilson name has been synonymous with quality and robust instruments in the laboratory environment. Through the years, Gilson s product focus has moved from
Automation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
How To Use An Acquity Qda Detector
Mass-Directed Isolation of a Synthetic Peptide Using the ACQUITY QDa Detector Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The ACQUITY QDa Detector
The Theory of HPLC. Gradient HPLC
The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims
ChromQuest 5.0 Chromatography Data System
ChromQuest 5.0 Chromatography Data System User Guide for the Surveyor LC CHROM-97257 Revision A March 2008 2008 Thermo Fisher Scientific Inc. All rights reserved. Surveyor and ChromQuest are trademarks
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
designed to never let you down PerkinElmer Series 200 HPLC Systems
designed to never let you down PerkinElmer Series 200 HPLC Systems an inside look at the Series 200 HPLC systems PerkinElmer knows you need to rely on your high performance liquid chromatography (HPLC)
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
Oasis HLB Cartridges and 96-Well Plates
CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION
for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns
for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 1 of 15 Product Manual for SolEx TM HRP Cartridges SolEx HRP (P/N 074400)
Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS
Summary: Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS UCT Part Numbers: CUNAX226 - Clean-Up C8+NAX, 2mg/6mL BETA-GLUC- ml Beta-Glucuronidase Enzyme, liquid form SLAQ1ID21-3UM -
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
GC-xt. The most flexible GC /GC-MS liquid sample injector
GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Abstract Presented here is a case study of a walk-up liquid chromatography
MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process
- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides
High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK
High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK Background Unilabs YBS are a bioanalytical CRO based in York (Uk) Copenhagen
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
Reversed phase C-18 chromatography: From analytical scale to preparative scale
Reversed phase C-18 chromatography: From analytical scale to preparative scale Veronica Thomason*, Jeffrey V. Mitten, and Paul Bellinghausen Teledyne Isco, Inc. P.O. Box 82531 Lincoln, NE 68501 2 Abstract
Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
SCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS
EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction
API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
Overview. Purpose. Methods. Results
A ovel Approach to Quantify Unbound Cisplatin, Carboplatin, and xaliplatin in Human Plasma Ultrafiltrate by Measuring Platinum-DDTC Complex Using LC/M/M Min Meng, Ryan Kuntz, Al Fontanet, and Patrick K.
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
Micromass LCT User s Guide
Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for
Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis
Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for
Analysis of Vegetable Oils by High Performance Liquid Chromatography
Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and
FRACTION COLLECTOR. Microcomputer Controlled CHF122SC
FRACTION COLLECTOR Microcomputer Controlled CHF122SC From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses.
[ Care and Use Manual ]
The Waters GPC Cleanup System uses two Envirogel GPC Cleanup Columns to perform routine cleanup of environmental samples as specified by EPA Method 3640A, GPC Cleanup. The columns, 19 x 150 mm and 19 x
STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA 94305-5080
Training on the ZQ Open access MS Questions? Contact Dr. Allis Chien [email protected] 650-723-0710 0710 STANFORD UNIVERSITY MASS SPECTROMETRY STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD
Chapter 28: High-Performance Liquid Chromatography (HPLC)
Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler
LC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
Determination of Caffeine in Beverages HPLC-1
Determination of in s HPLC-1 Introduction This experiment provides an introduction to the application of High Performance Liquid Chromatography (HPLC) to the solution of complex analytical problems. Cola
Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary
Application Note Purifying common light-chain bispecific antibodies using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, biochromatography Antibodies MCSGP Bispecific antibody,
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,
Innovative vs Traditional
And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late
Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance
Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid
AxION edoor. Web-Based, Open-Access Mass Spectrometry Software
AxION edoor Web-Based, Open-Access Mass Spectrometry Software 2 AxION edoor is the open-access software solution for today s fast-paced laboratory. It is designed to operate and optimize the management
Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide
Transforming a ChromLab Software -D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide Instructional Guide Chromatography Bulletin 675 ChromLab
Application of Structure-Based LC/MS Database Management for Forensic Analysis
Cozette M. Cuppett and Michael P. Balogh Waters Corporation, Milford, MA USA Antony Williams, Vitaly Lashin and Ilya Troisky Advanced Chemistry Development, Toronto, ntario, Canada verview Application
EQuan MAX Getting Connected Field Service Guide
EQuan MAX Getting Connected Field Service Guide This guide provides procedures to connect the various components for the Thermo Scientific EQuan MAX automated high-throughput LC-MS system. Contents Hardware
Protocol: HPLC (amino acids)
Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain
EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes
EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes Brussels, 18th May 2005 CED No 494 rev 2 Final TAXUD/3711/2004 POETRY:
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Background Information
1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software
Amino Acid Analyzer L-8900
Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is
AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs
AB SCIEX TOF/TOF 4800 PLUS SYSTEM Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM It s just what you expect from the industry leader. The AB SCIEX 4800 Plus MALDI TOF/TOF
Chemical analysis service, Turner s Green Technology Group
Chemical analysis service, Turner s Green Technology Group Hourly costs, Academic collaborations leading to co-publications: 627 SEK/hr (excl. VAT) Hourly costs, Industry/Academic collaborations, no publications:
Supplementary Materials and Methods (Metabolomics analysis)
Supplementary Materials and Methods (Metabolomics analysis) Metabolite extraction and mass spectrometry analysis. 12 Vldlr-/- knock out and 12 wild type (WT) retinas were separately frozen at -80 ºC in
Process Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
AMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide
chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo
Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# 600000-1621-RFQ)
Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) Closing Date and Time: Wednesday, April 13, 2016 at 5:00 p.m. (Pacific Time) Contact: Aaron Galloway Fax: 541-888-3250
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations
Training Courses 2014 HPLC GC SPE
Training Courses 2014 HPLC GC SPE 2 1 3 5 4 6 7 5 10 15 20 min 8 2 Courses & Presenters HPLC How to Run HPLC Methods Price: 249 + VAT Code: SS0-5943 Page: 4 How to Develop HPLC Methods Price: 249 + VAT
Diffusion and Fluid Flow
Diffusion and Fluid Flow What determines the diffusion coefficient? What determines fluid flow? 1. Diffusion: Diffusion refers to the transport of substance against a concentration gradient. ΔS>0 Mass
Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz
Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische
Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay
PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird
This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA
An Automated Method for the Fractionation of Extractable Petroleum Hydrocarbons (EPH) from Water and Soil Extracts Using the Gilson GX-274 ASPEC System Keywords: Aliphatic Hydrocarbons, Aromatic Hydrocarbons,
A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water
A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box
Elemental analyzer multi EA 5000
Elemental analyzer multi EA 5000 Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com [email protected] 1/6 multi EA 5000 The multi EA 5000 is a powerful elemental analyzer
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic
QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd
QUANTITATIVE AMINO ACID ANALYSIS Aurélie Lolia Applications Manager, Biochrom Ltd QUANTITATIVE AMINO ACID ANALYSIS Principles of amino acid analysis Ion exchange chromatography The Biochrom 30 physiological
SPE-TT. Tutorial Version 2009-08-11. Bruker BioSpin 2008-2009; File: Tutorial 11 - SPE-TT; Version: 2009-08-11; By: Dr.
SPE-TT Tutorial Version 2009-08-11 Introduction This document is a step-by-step guide for the usage of a SPE-TT system that elutes samples from SPE cartridges into the liquid handler. - Installation: Software
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
A Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,
Waters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water
Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water Chen Jing, 1 Dai Zhenyu, 1 Xu Qun, 1 Liang Lina, 1 and Jeffrey Rohrer 2 1 Thermo Fisher Scientific, Shanghai, People s
Alignment Laser System.
- O T 6 0 0 0 Alignment Laser System. The OT-6000. Multi -Target,Two Dimensional Alignment. Introducing the most powerful way to measure alignment at distances up to 300 feet. The OT-6000 Alignment Laser
Mitos P-Pump. product datasheet
product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump
Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.
Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2
Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France
Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS Mikaël LEVI Shimadzu France Welcome Seminar Barcelona 2013 Interest in Steroids assay by LC-MS/MS Steroids measurement is essential
for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)
for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) IonSwift MAC-100 & MAC-200 Product Manual Page 1 of 16 PRODUCT MANUAL for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) MAC-100, 0.5 x 80mm (P/N 074702)
HEAVY WATER LEAK DETECTOR
HEAVY WATER LEAK DETECTOR WEB www.overhoff.com MODEL 1925 HEAVY WATER LEAK DETECTOR (HWLD) LOW LEVEL REAL TIME TRITIUM-IN-WATER MONITOR This monitor has been designed for real time low-level detection