MPower 3000 Low Energy Door Operator Complies with ADA Accessibility Guidelines Copyright 2006 2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Table of Contents MPower 3000 Low Energy Door Operator Overview & Certifications...1 Standard Applications....2 How to Order...3 Typical Door Traffic....4 Parts List...5 Switches & RF Parts....6 Typical System Applications...7 Technical Details...8 Architectural Specifications...9 MPOWER 3000 Series is the latest generation of power door operators. Low energy door operators were once considered a necessity only for those with physical challenges. Today, due to the population s busy lifestyles, the convenience of hands-free door opening is more popular than ever. The patented design of MPOWER 3000 is based on ease and simplicity. MPOWER 3000 installs in minutes rather than hours and consists of three basic components: inverter, motor and closer body. Patents: 5,881,497, 7,316,096 and 7,484,333 On the Cover 3000 What separates MPOWER 3000 Series from other operators is its ability to function as a standard door closer. When the door is opened manually, there is little resistance and the drive train and motor are not engaged. The closer, not the motor, controls the closing cycle. Since the door closer does not back-drive the motor during the closing cycle, there is no loss of closer efficiency. In the event of a power outage, the door can be manually opened and will close via the door closer s spring force. MPOWER 3000 Series is listed with UL and ANSI/BHMA A156.19 and meets the requirements of ADA and ANSI/BHMA 156.4. MPOWER 3000 is ideal for doctors offices, retirement facilities, schools, churches, and any location where noise is a major concern and special features are not a requirement. MPOWER 3000 can be activated via wall switch, radio frequency device or motion sensor, and is available for push or pull side applications. Based on its dual functionality, ease of use and quiet operation, MPOWER 3000 Series offers the customer a unique choice! Note: Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Sargent Manufacturing Company makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
Overview & Certifications MPower 3000 Low Energy Door Operator Inverter Motor 1130 Closer Body Features & Functions Ease of installation and setup - Simple instructions Application versatility and ease of adjustment - Push or pull side mounting units available Operates as mechanical surface closer during close cycles, when door is opened manually or if power is turned off - Quiet operation - Spring force provides the feel of a normal manual door closer - Door can be opened manually if desired SARGENT 1130 series door closer - Adjustable Spring Power - Backcheck Valve - Sweep Valve & Latch Valve Non-handed Unit Activation Options - Wall switches - Radio frequency device End-User On/Off Switch Electrical Data Power Input; 120 VAC, 60Hz Current Draw:.6A or.3a Relay Output: DPDT - Normally Open/Normally Closed (jumper) - For electric strike function Certifications C-UL US listed for use on fire and smoke barrier doors 2-year warranty (refer to current SARGENT price book for terms & conditions) Meets requirements for Americans with Disabilities Act (ADA) ANSI/BHMA A156.19 certified Meets ANSI/BHMA A156.4 requirements Hold open options - 0-30 seconds (5 seconds minimum required for ADA and ANSI/BHMA A156.19) Obstruction detection - Motor stops if door is obstructed during an opening - Door closes under manual spring force (not to exceed 15lbf) Push and Close - Allows the operator to skip the hold open time when it is not necessary or required - Adjustable door sensitivity Overload Safety Shut-Off - After two minutes of receiving a door activation signal, the inverter will time out and close the door - Prevents motor/inverter damage Motor Start Delay for Locking Hardware - 0-5 second delay to allow locking hardware to release first 1
Standard Applications MPower 3000 Low Energy Door Operator Standard Applications 3060 Hinge (Pull) Side of Door Adjustable Stop 180 swing (trim permitting) Minimum Door width Single Door - 29" (74cm) Double Door - 30" (76cm) An auxiliary stop is suggested where severe conditions exist. NOTE: Contact factory for use on doors exceeding 250 lbs. NOTE: Contact factory for use on doors exceeding 250 lbs. 2 3051 Stop (Push) Side of Door Standard Duty Double Lever Arm Frame reveals 2-5/8" to 6-3/4" (67-171mm) An auxiliary door stop is required for these applications 170 swing (trim permitting)
How to Order MPower 3000 Low Energy Door Operator How to Order: 3051 x finish For stop (push) side of the door with double lever arm for reveals 2-5/8" to 6-3/4" to swing up to 170º 3060 x finish For hinge (pull) side of the door with rigid arm & slide track for a maximum reveal of 1/8" to swing up to 180º SARGENT Designation Description BHMA Designation EN Sprayed Aluminum 689 EB Sprayed Bronze 690 EAB Sprayed Brass 696 Note: Door switches and sensors are not included with the MP3000 Series Door Operators. These items must be ordered separately. 3
Typical Door Traffic MPower 3000 Low Energy Door Operator Typical Door Traffic Categories APPLICATION DAILY AVERAGE YEARLY AVERAGE USAGE OPERATOR Executive Office ADA Dorm Room ADA Hotel or Retirement Home Room MP3000 Assisted Living Up to 100 Up to 22,000 Low Low Energy Common Area Door Office/Warehouse Door ADA Auxiliary Entrance ADA Accessible Restroom Government/Public Restroom 300 108,000 Hospital Corridor Door 600 220,000 Moderate Office Building Entrance 1,200 450,000 Moderate Airport Entrance 3,000* 1,100,000 Large Office Building Entrance 4,000* 1,200,000 Large Dept. Store Entrance 5,000* 1,500,000 * Represents powered cycles Note: The above applications and data are examples for guidance only. Contact your ASSA ABLOY Door Security Solutions Sales Representative or SARGENT Technical Consultant to confirm the suitability of your specification and system design. 4 High MP4000 Low Energy Besam High Energy Door Operator
Parts List MPower 3000 Low Energy Door Operator Parts List 1130 SERIES CLOSER BODY RF POWER SUPPLY (optional) BREAKER SWITCH MOTOR ASSEMBLY 63-4294 INVERTER 63-0784 POWER SWITCH 63-0783 BACKPLATE REED SWITCH OPEN / CLOSE POSITIONING ASSEMBLY 63-4293 CHAIN 63-0781 PINION EXTENSION / CLUTCH ASSEMBLY 63-4295 Arm and Track Assemblies 63-4287 - Arm and Track Assembly 63-4288 - Arm Assembly 63-4289 - Track Assembly Cover 63-0780 63-4290 - Standard Arm Assembly 63-4291 - Arm Assembly less Rod and Shoe 63-4292 - Foot Assembly 5
Switches and RF Parts MPower 3000 Low Energy Door Operator Supplied with each MP3000 is the 63-4306 Signage Kit which contains two of each of the three labels shown above Accessories SARGENT MODEL 4396HP DESCRIPTION VIEW NOTES 6" x 6" Square wall switch with handicap logo & Press to Open 6 4396P 4395HP 4395P FOB1 RFR1 4397HP 4341 4399 6' x 6" Square wall switch with Press to Open 6" Round wall switch with handicap logo & Press to Open 6" Round wall switch with Press to Open Key Fob Transmitter RF Receiver Narrow type switch 1" x 3/4" Surface Mount Pushbutton 2" Square Green Pushbutton Momentary SPDT contacts rated at 500ma @ 12 VDC or 24 VAC Mounts in standard single or double gang electrical box or in 6-1/2" x 6-1/2" x 1-3/4" surface mount box provided Wireless Switch Option: - Operates at 433MHz - Operator requires RF receiver (#RFR1) - Switch is to be surface mounted in box provided - Specify RF to switch number to order (Ex: 4395HPRF) 433MHz Key Fob used with RF Receiver Radio Frequency Receiver (433 MHz) 24 VDC power supply Activation switches not included. Mounts flush through a 1-3/4" x 2-7/8" cutout in jamb or in the 4-3/4" x 2" x 1-7/8" box provided Momentary SPDT contacts rated at 500ma @ 12 VDC or 24 VAC Surface mount push button Momentary DPST contacts rated at 3 Amps Single gang push button with green LED Momentary SPDT contacts rated at 10 Amps
Typical System Applications MPower 3000 Low Energy Door Operator ACCESS CONTROL FOR ENTRY Opening Description: Fail Secure ADA Opening Electric Strike & Door Operator Application Rated or Non-Fire Rated Metal Door Interior or Exterior Office, Main Entrance or Stairwell Openings Operation Activate or deactivate system by a key control switch When outside, door switch is inactive, ingress will be by Pin or Prox only Inside door switch will unlock and open the door automatically Push exit device bar to exit at all times Door operator acts as standard door closer when entering or exiting manually Material SARGENT MPower 3000 Door Operator Sargent 8900 Mortise Exit Device 2-SARGENT 4396HP Door Switches Sargent 4370L Maintained Key Switch Sargent 4293 Wall Prox Card Reader Hes 1006 Electric Strike 1-12 VDC or 24 VDC Regulated and Filtered Power Supply Dual out put timer by others 120 VAC MAGNETIC LOCK Opening Description: Fail Safe ADA Opening - Magnetic Lock & Door Operator Application Non-Fire Rated Glass Door - Interior or Exterior Office or Main Entrance Openings Operation Lock or unlock system by a key control switch at all times Free ingress & egress using the door operator or manually when unlocked Outside door switch will be inactive denying ingress other than by Pin or Prox when locked Electric Strikes Opening Description: Fail Secure ADA Opening Double Electric Strike & Door Operators on Pair of Doors Application Interior, Non-Fire Rated Wood or Metal Doors Corridor or Emergency Room Openings Operation Doors are to be closed and latched at all times Key Switch activates and deactivates door switches to signal door operators Active door switch will energize the electric strike and automatically open doors Note: Not available for use with latch retraction exit devices To exit, inside door switch will unlock magnetic lock and open the door or manually push bar to exit Door operator acts as standard door closer when entering or exiting manually Material SARGENT MPower 3000 Door Operator SARGENT 1584 Electromagnetic Lock McKINNEY QC4 Electric Hinge SARGENT 55-8895 Mechanical Touch Bar with Switch 2-SARGENT 4396HP Door Switches SARGENT 4370L Maintain Switch SARGENT 4293 Wall Prox Door operators will act as standard door closers when entering or exiting manually Material 2-SARGENT MPower 3000 Door Operators FOLGER ADAMS 310-4-1 Double Electric Strike 2-Sargent 8700 Surface Vertical Rod Exit Devices 2-SARGENT 4396HP Door Switches SARGENT 4370L Maintained Key Switch SARGENT 4293 Wall Prox Dual output timer by other 120 VAC 120 VAC 7
Technical Details MPower 3000 Low Energy Door Operator Circuit breaker Activation switch terminal Relay terminal POT DESCRIPTION 8 H/O TQ REV SPD M/DLY H/O TM OBSTR SENS PUSH SENSE Motor Torque at Hold Open Position Motor Reversing Speed Motor Delay on Opening Hold Open Time (5-30 Seconds) Obstruction Detection on Open Push Recognition Sensitivity
Architectural Specifications MPower 3000 Low Energy Door Operator General Specifications 2.0 Low Energy Door Operators A. Door Controls (interior) (exterior) swinging door(s) shall be of rack and pinion design contained within a precision cast aluminum housing. B. Door closing force shall be adjustable to ensure adequate closing control. C. Door closing speed shall be controlled by independent hydraulic adjustment valves in the sweep and latch range of the closing cycle. D. Door Operator shall provide conventional door closer opening forces unless the power operator motor is activated. E. Door Operator shall provide conventional door closing forces at all times except in the event of power outage during powered door open cycle. F. Door Operator opening force and speed shall be adjustable by independent electronic adjustment to ensure adequate opening control per accessibility codes. G. Door Operator shall have an adjustable hydraulic backcheck valve to cushion the door speed if door is opened violently. H. Door Operator shall have a manual adjustment to locate both full open and full closed door positions. I. Maximum door open shall be adjustable and capable to a maximum 180 conditions permitting. J. Door Operator shall be SELECTIVELY ACTIVATED by external initiating device, i.e., wall switch, etc. K. Door Operator shall be both AUTOMATICALLY ACTIVATED and SELECTIVELY ACTIVATED. L. Door operator shall have adjustable hold open time capability in range from 5 to 30 seconds. K. Door operator shall have input line rating of 120VAC,.6A or 240VAC,.3A. M. Units shall have relay contact for interfacing products having a contact rating of 30VDC at 1A or 125VAC at.5a. N. Unit shall have an external On/Off Switch to defeat powered opening when desired. O. Unit shall have an internal circuit breaker switch to interrupt input power for servicing. P. Unit shall be U.L. Listed for automatic closing door. Q. Unit shall be in compliance with the requirements of the Americans With Disabilities Act (ADA), ANSI standards A117.1 and A156.19. Unit shall meet C-UL US. Additional Detailed Specifications A. When activated, the unit shall, by means of an integral motor and chain drive, power open the door at both a speed and force that are adjustable to meet accessibility codes. B. The door shall be powered from a door closed position to a full door open position and remain in momentary hold open for seconds (adjustable 0 to 30 seconds) [(Unit shall power open door to full open position up to 180 (3060); 170 (3051), conditions permitting.) (Unit shall be capable of allowing the door to be opened manually from 0 to 180, conditions permitting.)] C. Once unit reaches full hold open position, if reinitiated, unit s momentary hold open time shall restart from the initially set hold open time. D. If unit is initiated during the closing cycle, unit shall revert to opening cycle beginning at that door position. E. Obstruction detection on open shall neutralize and reverse motor action reverting motor to closed position thus allowing door to close under closer spring force only. F. This obstruction detection feature shall be integral to unit. G. During closing cycle, the unit shall close door under spring power not to exceed a closing force of 15 lbf. 9
SARGENT Manufacturing Company 100 Sargent Drive, New Haven, CT 06511 USA 800-727-5477 www.sargentlock.com Founded in the early 1800s, SARGENT is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company s customer base includes commercial construction, institutional, and industrial markets. Copyright 2006-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. 90146:C-08/01/11