Auto Feed Drills and Tappers Tapping Methods

Similar documents
Electro-Pneumatic Bus Door Control Mechanism

Proximity Switches RS (Reed Switch)

Single sub-base valve

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

SIMPLIFIED VALVE CIRCUIT GUIDE

Color Mark Sensor with Red or Green LED E3S-VS

Electro-pneumatic control valves

Unit 24: Applications of Pneumatics and Hydraulics

Assisted lift operated 2/2-way solenoid valves Type EV250B

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Model SETR-50 and SETR-51 Trim Tab Control

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

D.C. Motors. Products and specifications subject to change without notice.

TECHNICAL DATASHEET Incremental Encoder RI 80-E

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Turbine Flow Sensor Series VTR

Electric Lifting Cylinder TV / KV 5 XE Load up to N

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

ALBINS SEQUENTIAL SHIFTER

Magnetic proximity switches

HT3 series Peck Feed Drills, with Equal Drill Time

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

REGTRONIC OPERATING INSTRUCTIONS

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

SIMPLIFIED VALVE CIRCUIT GUIDE

Post Mount Light Installation*

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

HERZ-Thermal Actuators

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Hydraulic Flow Control Valves

QR12 (1.22 ) Diameter Optical Encoder

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Valve systems Base plates, according to standard ISO Brochure

Smart DeviceNet Remote I/O Terminals

Digital Keypad Use s Manual

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Rotary actuators Rotary wing drives Series RAK. Brochure

Instruction Manual. ThinkTop Basic Digital VDC PNP/NPN ESE00225EN

Duct Humidity Transmitter

3 Port Solenoid Valve

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

How To Drive A Compact Serie 1

Cable Plug acc. to DIN EN , Form A

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Original Assembly Guide

Capacitive Prox E2K-X

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

2/2 and 3/2 Way Size 6 Seat Valves

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

G1/4 Q8. Standard with biased position

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

K-39/K-39B. Drain Cleaning Machine. Ridge Tool Company/Elyria, Ohio, U.S.A.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

SELECTION, APPLICATION AND MAINTENANCE

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

TS93 EMR T/PT/TDE. Surface applied door closer

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

A descriptive definition of valve actuators

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

General 1-2-Opto-electronics Safety Switches 4-Emergency

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Operators manual Basic water heater

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

3/2- and 2/2-way cartridge valve type BVE

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

2M IR Mini Dome Quick Installation Guide

Absolute Rotary Encoder E6CP

Proportional pressure regulators VPPE

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Procedure for testing the integrity of the Festo and Numatics valve stacks:

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Hydraulic Control Solutions

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

Magnetic Proximity Switches Series CST - CSV and CSH

3/2-way Solenoid Valve, direct-acting, NC or NO

Procenter Delivery System* Troubleshooting Charts

400 Series Buccaneer BUCCANEER POWER. bulgin

RM/55401/M, Roundline cylinder Magnetic piston, double acting

Digital inductive conductivity transmitter

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

Transcription:

AFD425 Tension Tapper Air Feed/Air Motor Drive HCU for Rapid Advance Cyl Tension/Compression Quick Change Floating Tap Holder 1

Motor Reversal Cicuit Mains Air Cyl. (Forward) Not Gate 1 M Port 2 Mains Air 3 Output to And Gate AND Gate From R and NOT Forward Reverse on 2 HM5 air motor 2

All Pneumatic Tension tapping uses an AFD unit with external air motor drive (AFD425 or AFD625) to allow the spindle direction to be reversed. The tap is held in an axially floating holder to allow it to cut it s own thread. The axial float must always have tension, compression is optional depending on the application. How it works The unit is advanced through air pulse into 1 port or electrical pulse into S1 Solenoid Valve. There is a pressure tapping that starts the motor in the forward direction (see circuit diagram 104562) An HCU is set to give the required rapid advance controlling the feed on the tap just as it enters the pre-drilled hole. The tap holder with axial float will allow the tap to feed through at the rate required. (Note can be used with multiple spindle heads provided each spindle has axial float.) At end of stroke (adjustable from 0 4 ) the depth signal reverses the motor direction using circuit (104562), tool also automatically retracts. When unit returns to home position the air motor stops ready for the next tapping cycle. External control is through the A1 Control Block. Tension/Compression Spindle Float on AFDE400/410/420/610/620 Features Provides both radial float and tension and compression lead compensation. Quick Change of Taps 51 series tap adaptors ordered separately Low friction ball bearing drive Tension and compression strokes can be varied to suit the application Part Number Max Dia T.I.R. Float Total Stroke L L1 321-1-210FC 0.59 4.85 2.59 321-1-210FT 1.38 0.070 0.59 4.26 2.59 321-1-210TNC 0.59 * 2.59 321-5-210-FC 1.58 6.82 2.59 321-5-210FT 1.38 0.070 1.58 5.24 2.59 321-5-210TNC 1.58 * 2.59 FC = Full Compression, FT = Full Tension, TNC = Tension and Compression standard is 50% of each unless specified * Will vary according to amount of tension and compression subtract tension stroke from L 3

Quick Change Tap Adaptors 51 series 51 Series Tap Adaptors Item Number Tap Size L1 L2 L3 L4 D1 D2 Max Dia Projection 51-106 0 6 0.31 1.51 51-108 8 1.57 51-110 10 0.39 0.37 1.73 51-112 12 0.31 1.79 51-004 ¼ 1.80 51-005 5/16 0.84 0.16 0.73 0.748 1.18 1.95 51-006 3/8 0.39 2.11 51-007 7/16 0.38 2.36 51-008 ½ 2.55 51-009 9/16 0.31 2.79 NTER-CC Extended Range, Close Centre Tap Adaptor Permits the use of larger taps with small diameter holders NOT RECOMMENDED for high torque applications Part Number Tap Size L1 L2 L3 D1 D2 Max Dia Projection 51-010 5/8 4.24 51-011 11/16 4.39 51-012 ¾ 0.83 0.99 2.19 1.17 0.748 1.18 4.55 51-013 13/16 4.77 51-014 7/8 4.93 4

Full Feature Control Block A1 - Forward Feed Air Only, Return Feed Air/Spring or Both Summary of Ports/Features 2 Mains Air Inlet 1/4 BSP adaptor supplied to ¼ NPT 3 P Port tapped M5/10-32, signal port for Pecking/Dwelling 4 Manual Retract Button - Red 5 1 Port tapped M5/10-32, for remote start air pulse signal 6 Manual Start Button - Green 7 R Port tapped 1/8 BSP with adaptor to 1/8 NPT supplied supply for air return 8 S2 Electric Interface Port, for remote retract using a solenoid valve (24Vdc/110VAC) 9 SW2 Electric Interface Port, for electric depth signal through a proximity switch (M8) 10 End Stop - to automatically return tool when at depth 11 Main Air Regulating Screw 12 S1 Electric Interface Port, for remote start using a solenoid valve (24Vdc/110VAC) 13 Retract Rate Regulating Screw 14 Advance Rate Regulating Screw - functions on Air Return tools Only 15 0 Port tapped 1/8 BSP with adaptor to 1/8 NPT supplied, remote depth/retract, signal port for Pecking/Dwelling 16 SW1 Electric Interface Port, for electric datum signal through a proximity switch (M8) 17 M Port tapped M5/10-32, for air signal in datum position - constant 5

Input and Output Signals - NOTE : Remote Electrical Signals Require an Interface Kit Input Signal Output Signal Manual Remote Air Remote Electrical (Requires additional kit) M Port (17) SW1 (16) Datum Constant Air Constant Signal Through Signal M5/8 Proximity Switch Forward Retract Depth ST Green Button (4) SP Red Button (6) 1 Port (5) Give Pulse Air Signal O Port (15) P Port (3) Constant At Depth O Port (15) P Port (3) Give Pulse Air Signal S1 (12) Through Solenoid Valve Pulse Signal SW2 (9) Constant Signal Through M5/8 Proximity Switch Automatic S2 (8) Through Solenoid Valve - Pulse Signal End Stop (10) NOTE: - Main Air Inlet ( ) The main air inlet (1/4 BSP or NPT) must be connected to an air supply for both the AFD and AFDE tools as the air supply to the tool and block is provided through this port. Circuit Diagram The circuit diagram below shows the workings of the control block circuit. A1 - CONTROL BLOCK CIRCUIT DIAGRAM DEPTH SW2 DATUM SW1 START S1 STOP S2 M DEPTH VALVE DATUM VALVE 1 START 0 STOP R AIR MOTOR (AFD ONLY) P CYLINDER FEED CYLINDER RETRACT (AFDE200/700/710, AFD205/215) Flow Control Settings Tool Type 13 11 14 Step 1 Step 2 Step 3 AFD426/625 Affects Retract Rate Only Affects Forward Rate Only No Affect 6

Electrical Interface Kits The interface kits are used to control the AFD range using electrical signals to provide start and retract signals and feedback for depth and datum. Generally for use with P.L.C. s (Programmable Logic Controllers) the kits contain solenoid valves and proximity switches of differing types depending on the method of control and on which control block they are being used with. All solenoid valves and proximity switches are of the plug in type. Supply voltages are 10-30V DC for the proximity switches and commonly 24V DC for the solenoid valve. The proximity switches are supplied in both PNP (most common - sourcing) and NPN (sinking) and are normally open (NO). The solenoid valves have DIN type connections on the plug and can be normally open (NO) or normally closed (NC - most common). Fitting an Interface Kit to an A1 Control Block Remove the blanking plates at positions S1 and S2. Fit the 2 solenoid valves ensuring the gasket is fitted correctly between the valve and the control block. To fit the proximity switches remove the blanking plugs at positions SW1 and SW2. NOTE: There is a constant air supply from the SW1 port. The proximity switch must seal against this air pressure. There is an air supply from the SW2 port at depth only and again the proximity switch must seal against this air pressure. With the tool at the datum position fit a proximity switch in SW1 by gently rotating clockwise until a some resistance is felt. Rotate the switch approximately one turn anti-clockwise and make sure the switch is sensing. Similarly with the depth stop depressed insert the other switch in SW2 and follow the same procedure. Make sure the switch is sensing. M P SW1 0 Datum Proximity Switch Start Solenoid Valve 1 S1 Emergency Return Solenoid Valve Operation of Interface Kits R S2 SW2 Depth Proximity Switch Input Signals: Start - For interface kits C10 and C12 - To start the cycle energize the Normally Closed solenoid at position S1 for approximately 0.5 seconds. The tool will cycle automatically. For kit C11 - The Normally Open solenoid valve is fitted to S2 and so to start cycle energize both solenoids (Note with electric power off and air on air will exhaust around red stop button) NOTE: External solenoid valve can also be used to give pulse start signal to 1 port. 7

Emergency Return - For interface kits C10 and C12 - To stop the cycle and return to home energize the Normally Closed solenoid at position S2. For approximately 0.5 seconds. The tool will return to datum. For kits C11 - The Normally Open solenoid valve fitted to S2 is de-energized to stop the cycle. This also acts as a fail safe should the electrical power fail. NOTE: External solenoid valve can also be used to give pulse start signal to P or O port. Output Signals: Depth - The proximity switch at SW2 will provide a signal upon reaching depth. Datum - The proximity switch at SW1 will provide a signal when the tool is at datum. Kit Types for A1 blocks Code Part No. Control Block Solenoid Valves Proximity switches C03 104002 A1 (M8) 2 x M8 PNP + Cables C05 104842 A1 (M8) 2 x M8 NPN + Cables C10 438223 A1 (M8) 2 x NC 2 x M8 PNP + Cables C11 438233 A1 (M8) 1 x NO, 1 x NC 2 x M8 PNP + Cables C12 438243 A1 (M8) 2 x NC 2 x M8 NPN + Cables Individual Proximity Switch Part Numbers & Specifications Proximity Switch Type Part Number Operating Voltage Voltage Drop Rated Operating Current Operating Temperature M8 PNP NO 381223 10-30V <=2.5V 250mA -25 to 70 C PNP Cable 381233 M8 NPN NO 396183 10-30V <=2.5V 250mA -25 to 70 C NPN Cable 397043 Cable Connections 24V (Brown) to 24V 0V (Blue) to 0V Output (Black) The output is short circuit protected (pulsed). After elimination of the short circuit the switch is ready again for operating. Solenoid Valve Part Numbers & Specifications (Supplied with DIN style plug no cable) Solenoid Valve Type Part Number Rated Voltage Rated Power NO 396263 24V 2W NC 326753 24V 1W 8

Feed Control - Hydraulic Control Unit (HCU) Mounting and Use Allow rapid advance under air pressure then a controlled feed up to the stroke of the HCU They also reduce burring on the exit side of the hole by preventing the tool from jumping through the hole when the drilling pressure is relieved. It also eliminates the possibility of the drill unit stalling as it breaks through To fit the HCU Remove the plastic cover (2 socket head cap screws) to reveal the HCU mounting bracket (also for stroke adjustment). Slide the HCU into the bracket ensure the flat on the HCU lines up with the flat on the bracket. The groove on the HCU should be just below the bracket ensure it does NOT prevent the fine stroke adjustment screw from touching the depth valve the tool will NOT return if this happens. To refit the cover there is a knock-out that has to be removed by hand or with pliers. Feed Control Adjustment Max Dimension X D1-1 D2-2 D3-3 AFD205/215 AFD415 AFDE200>=2350 2.7 4.7 6.7 AFDE400>=900 AFDE600>=900 AFDE400<=550 0 1.9 3.9 AFDE600<=550 u Flat on HCU and Bracket Fine depth adjustment screw Groove Depth return valve Standard Available HCU s D1-1 D2-2 D3-3 9