CONTROL SISTEM S.r.l.

Similar documents
Cooling Channel Optimization

ORGANIC SAMPLE PREPARATION

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

KNC Model 3666 Automatic Pressure Calibration System

Designed for multi-injector endurance testing, the

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

LyoBeta. R+D Freeze-Dryers

Medical Vacuum Systems-PXMI

The On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.

E - THEORY/OPERATION

Medical Air Systems: Scroll

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Vacuum drying oven for non-flammable solvents

Process Alarm Solutions

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Signature and ISX CM870 Electronics

ON-VEHICLE INSPECTION

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Diagnostic Fault Codes For Cummins Engines

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Cooking at the Speed of light!

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Stack Sampling Stack sampling or source sampling

Online Infrared Flue Gas Analyzer Gasboard 3000

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

Intelligent Vibration Monitoring

Commercial Semi-Instantaneous Water Heaters

On-line Dissolved Gas Analysis

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

COMBIMASS. Technical Data COMBIMASS eco-bio +

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

The Business case for monitoring points... PCM architecture...

Technical Specification. Generating Set with Waukesha engine burning natural gas

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

MOLECULAR DRAG PUMPS MDP SERIES

Material test chamber with mechanical convection

1 Application Description Objective Goals... 3

MINIMAT-EC-Servo Screwdriver Spindles

How is Dew Point Measured Reliably?

Contact. Workshop on advanced flow computing with the SUMMIT March 24 27, May 19 22, August 18 21, November in Breda, The Netherlands

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Heating oven with mechanical control

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Freezers - Ultrafreezers. Platilab & Irilab Series

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1

Heating Controller. Building Technologies HVAC Products

T a b l e o f C o n t e n t s

TECHNOLOGIES FOR SLEEVE APPLICATIONS. English catalogue

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

SHORT TRAINING COURSES

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

API Marine. BMS Presentation. Ballast Measurement Systems

Gas Custody Transfer Calibration

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Computer Controlled Automobile Air Conditioning Trainer, with SCADA TAAUC

TMS TANK MANAGEMENT SYSTEM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Research RF Sputtering Packages

Power consumption (kw)

A Practical Guide to Free Energy Devices

Typical Aluminum GFM Mass Flow Meter

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

High Power Programmable DC Power Supplies PVS Series

Computerized Micro Jet Engine Test Facility

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

GAS LEAKAGE DETECTION & AUTO ON-OFF GAS SYSTEM

ECOCIAT. Domestic hot water heat recovery unit

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

Product Information Sheet UH36 Hi Pot Tester

Electric Rotary Actuator - On/Off or programmable control actuator

Intelligent Mould Flow Monitoring

Car and commercial cial air conditioning service solutions

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

VDL 53 - Vacuum drying oven for flammable solvents

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Products and solutions for pumping, irrigation and piping

Rotary screw compressors kw 5,5 7, , bar MODULO

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

STERILIZERS, LABORATORY DRYING OVENS

Electronic Diesel Control EDC 16

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

Heating oven with mechanical convection

Ammonia Detection System Codes and Design Specifications

MODEL TEG-F20. Specification Sheet. TEG-F20 Specification Sheet Ver Copyright(C) 2011 Tsukasa Sokken Co., Ltd.

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

S300 Series Dust Monitors

HEATER, AIR CONDITIONING AND VENTILATION

Transcription:

CVS-R03 CONTROL SISTEM S.r.l. Via COLLEGNO 29 int.- 10040 - PIANEZZA (TO) ITALY TEL.+39-011-9672072/3 FAX +39-011-9672044 E-mail: info@controlsistem.it Web: www.controlsistem.it

-Page 2- CVS - R03 The CVS equipment has been engineered to perform emissions test from internal combustion engines, according to the latest requirements of all official International Emissions Regulations. According to the CVS principle, during the test the whole exhaust flow of the engine is diluted with ambient air, in order to avoid water condensation and to freeze chemical reactions among the gases components. The total mixed stream is then metered by PDP (positive displacement pump) that maintain a constant volume flow rate and allows to vary the flow rate for obtaining the more suitable dilution factor for the tested vehicle. A simultaneous sampling is performed by a constant flow pump that routes the gas to a sampling bag for analysis after the test. Similar amount of dilution air is simultaneously collected in another bag thus allowing the evaluation of the background emissions that have to be deducted from the masses calculated in the diluted flow. The system is equipped with 3 couples of bags so the test can be divided up to 3 parts.

-Page 3- As the final assessment is based on the volumetric concentration measurement of regulated compounds in a diluted exhaust stream, significant efforts have been aimed to two basic directions: o Increase the concentration of measured components, o Increase the accuracy and reliability of volume determination. In order to comply with these tasks CVS-R03 is equipped with a variable speed pumping system (PDP) with fast pressure and temperature sensors at pump inlet. In this way it is possible to set the better dilution factor for the test and to get a real time control of the constant diluted flow. CVS basic unit This part of the equipment is assembled in a compact cabinet with doors and removable panels and is housing the PDP pump, the cyclonic separator and the heat exchanger. The required flow is automatically selected in a continuous range using a variable speed driver for the motor of PDP pump allowing a precise adjustment over the requirements of dilution for the specific engine type and size. The flow control unit is provided with high accuracy absolute pressure and temperature transducers that exceed the requirements of European and US regulations for the emission equipment. The wiring cabinet is equipped with a I/O system using a WAGO micro PLC with Ethernet connection to the control PC of the system.

-Page 4- Upstream the PDP pump section, 2 efficient heat exchangers are provided, with the task to maintain the temperature of the diluted flow in front of the pump in a very narrow temperature range. A regulation routine in the standard software package takes care of the complete management of the warming function of the Sampling Unit and of the relevant alarms detection. Typical temperature regulation accuracy is +/- 2 C around the recommended set point of 40 C. Constant flow gas sampling for the Bags filling function is provided through pumps and a flow rate controllers. All internal piping and the components in contact with the diluted exhaust stream are manufactured in AISI 316 Stainless Steel; Teflon hoses are used with Stainless Steel high quality fittings. Bags sampler. In a single unit are collected all the sampling provisions for bags filling and the bags themselves, which are therefore well protected against mechanical damage. The flow routing for the different functions is managed by a sampling module with modular manifold and distribution valves. The exclusive design of the unit is engineered as a modular assembly, incorporating the shutters

-Page 5- body, the pilot valves auxiliary blocks, the bags vacuum switches and also the housing for the complete electronic section, with the power drivers for the valves. The manifold is designed to handle up to 8 fully independent sampling bags, 4 for diluted gas and 4 for dilution air. The following pumps are assembled in the service section of the cabinet and provide for the activation of the flows: o Dilution air: diaphragm sampling pump, flow rate 25 lpm, o Diluted gas: diaphragm sampling pump, flow rate 25 lpm, o Bags evacuation: rotary vane vacuum pump, flow rate 100 lpm, o Bags purge line: diaphragm pump, flow rate 40 lpm. The Tedlar Bags are suspended to independent rails inside a dedicated section of the cabinet, and provided with pressure sensors that allow to determine when the bags are full or empty. Programmable timers are also active in the control software as additional safety measure against bags overfilling. Computer Control System. The control computer of the system is installed in the Bag Sampler unit and is engineered over a distributed I/O concept, based on a standard Ethernet network with dedicated nodes in any single piece of equipment of the complete equipment. A standard Ethernet TCP/IP port is used on the Control PC and a Ethernet multiport switch is used to connect the connect the different WAGO I/O system of each CVS component. Each I/O system is equipped with analog and digital I/O board to fully control the CVS equipment.

-Page 6- The data acquisition section of the CVS PC Controller is managing a wide range of signals and control processes, which include: - Absolute pressure at pump inlet - Flow temperature at pump inlet - Rotational speed of the PDP - Real time flow rate calculation - Water temperature in the conditioning circuit - Regulation routine for the heat exchanger - Bags vacuum signals - Bags overfill signals - Dilution air temperature - Diluted gas temperature at sampling point The software on the control PC is developed using Control Sistem standard INT900 system and is written in accordance to the US and European regulations and can indicate to the operator all the non conformities of the system to these regulations. The acquired measures are visualized in real time and saved in a LOG file by the system are the followings: The main function of the software are: - monitoring the status of the system; - visualization and logging of all alarms and warnings; - selection of the working parameters of the system; - regulation of the heat exchangers; - regulation of the PDP; - calculation and saving of the real instantaneous flow rate through the PDP using the pressure, temperature and speed transducers placed on the pump;

-Page 7- - calculation and saving of the total integral volume passed through the PDP for each step of the test; - bags filling; - connecting the bags with the gas analyzers; - bags purging and evacuating - checking possible leakages in the system; - semiautomatic calibration procedure with simple operator interface and complete data calculation. The system has a complete local control for all the functions using the PC touch screen and keyboard. For the remote control from the main control unit, a standard communication protocol (AK protocol) through a serial port or a TCP/IP Ethernet connection is available.

-Page 8- The PC is supplied with 2 Ethernet boards, one dedicated to the local network and the other dedicated to the external connection. For all the signals managed in the system a recording function is available, particularly useful for troubleshooting, which provides Excel files with fully engineered data acquired up to 10 Hz frequency.

-Page 9- The following main functions are available through a conveniently arranged Operator interface: - Bags evacuation, purge and filling - Bags analysis, - Diluted gas analysis - Monitoring of CVS flow rate, - Calculation of integrated flow during each test s phase, - System Mode monitoring, - System Faults monitoring and warning, - Manual selection of test phase, - Complete I/O monitoring and check, - Complete PDP calibration routine, - Log of PDP calibrations and leak checks performed during the useful life of the equipment, - Selection of the sampling flow rate to the bags. Connection tailpipe to CVS. Fiberglas/silicon flexible hose with proper stainless steel termination to adapt different vehicle exhaust tailpipe configurations (1 side or 2 side). The temperature range of the pipe is -40 +300 º C In this specific case, the proposed specification is: length 5 meter with an internal diameter of 150 mm.