Intelligent Lift Control Valve with Electronic Card

Similar documents
3/2 Solenoid Cartridge Valve, Size 6

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Hydraulic Control Solutions

Assisted lift operated 2/2-way solenoid valves Type EV250B

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

3/2- and 2/2-way cartridge valve type BVE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

2/2 and 3/2 Way Size 6 Seat Valves

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Proportional pressure regulators VPPE

Chapter 6: Check Valves

Single sub-base valve

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

RM4TG20 three-phase network control relay RM4-T - range V

Plunger Cylinder. 1 Description. 2 Technical data

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Combi switchbox with integrated 3/2 way pilot valve

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Digital input modules

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Solenoid Operated Directional Valves

Three-phase monitoring relay CM-PFE

Electric Rotary Actuator - On/Off or programmable control actuator

Unit 24: Applications of Pneumatics and Hydraulics

Electro-pneumatic control valves

Rack mounted telephone- and leased line modem for industrial applications

Telephone- and leased line modem for industrial applications TD-36

Duct Humidity Transmitter

Pressure transmitter For general industrial applications Model A-10

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Load-sensing control block in mono and sandwich plate design

Pressure reducing valve, direct operated, Type ZDR 6 D

Series description: Wilo-Yonos MAXO-D

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Cable Plug acc. to DIN EN , Form A

4/2-Way Pneumatic Solenoid Valve

Electro-hydraulic pressure switches type DG

CONFIGURABLE SAFETY RELAYS

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Digital inductive conductivity transmitter

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Solenoid Operated Directional Valves

Directional seated valves type VP 1

Inductive Proximity Sensors

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

MINI MCR-SL-R-UI(-SP)

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

SOLENOID VALVES 3-4 WAY

CQM1-SF200/CS1W-SF200

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

DLP-PU/E Instruction Manual

Series description: Wilo-Yonos MAXO

How To Use A Flowmeter

15/40/80CN Series Medium Pressure Filters

G1/4 Q8. Standard with biased position

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Air damper actuators

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PUMP AND MOTOR DIVISION

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

RY2 miniature industrial relays

HERZ-Thermal Actuators

Transcription:

Intelligent Lift Control Valve with Electronic Card Q max = 500 l/min, p max = 80 bar Leak-free, two-stage, electronically controlled, without frequency control i50 and i500 Information lift-control valve No modifications of the travel curve or mechanical adjustments are necessary Constantly short travel times, regardless of loading and temperature Constant levelling accuracy of ± mm, which prevents dangerous tripping accidents Self-monitoring function guarantees fully integrated A conformity (TÜV approved) Pleasant acceleration and slowdown thanks to an electronically controlled travel curve Soft-stop function for smooth approach and entry. The ivalve lift-control valve is an electronically controlled hydraulic valve block for controlling hydraulic lifts. The ivalve is situated on the hydraulic power unit and activated by the lift control system. Electronic control is accomplished by an electronic unit the icon that is housed in the control cabinet. At standstill, the weight of the lift is supported by a check valve integrated in the ivalve. In operation, the electronic controller regulates the states Travel UP and Travel DOWN, and the transitions between these states. In the electronic unit, the travel is represented in a form known as travel curves. During operation, the travel curves for that particular lift are optimised by the learning algorithm iteach. In addition, the valve block includes the following functions and components: a hand pump with manual emergency lowering (with piston-creep prevention), a ball valve, a pressure gauge, a pressure sensor with up to two pressure switches, speed monitoring, a temperature sensor, an emergency stop DOWN valve (UCM/A) in accordance with EN 8.. Technical data ivalve General characteristics, value, unit i50 i500 Designation Design Intelligent lift-control valve Leak-free, two-stage, electronically controlled Mounting method G Pipe mounting or low mounting (see interface in Installation info. ) G ½ Pipe mounting or low mounting (see interface in Installation info. ) Size - Port P - Port T - Port - Port Z - Port Z G G Hose, oil-resistant (id = 8 mm, od = mm) 8 L EN ISO 8- G ¼ G ½ G ½ Hose, oil-resistant (id = 8 mm, od = 0 mm) L EN ISO 8- G ¼ Tightening torque - Port P - Port T - Port - Port Z - Port Z 0 Nm ± 0 % 0 Nm ± 0 % Hose 0 x (pushed on) 0 Nm ± 0 % 5 Nm ± 0 % 500 Nm ± 0 % 500 Nm ± 0 % Hose 0 x (pushed on) 500 Nm ± 0 % 5 Nm ± 0 % Reference: 00-P-90058-EN-0 Issue: 05.06 /

General characteristics, value, unit i50 i500 Weight 0. kg.5 kg Mounting attitude Ambient temperature range As illustrated see section Dimensions + C +0 C Hydraulic characteristics, value, unit i50 i500 Nominal pressure 80 bar 80 bar Maximum flow rate 50 l/min 500 l/min Nominal flow rate Down (Z > T) Flow direction see section Performance graphs P T (bypass) P Z (UP) Z T (DOWN) Hydraulic fluid HL and HLP mineral oil to DIN 5 5; for other fluids, please contact BUCHER Hydraulic fluid temperature range Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 06 : 999 +0 C +60 C 0... 500 mm /s (cst) Class /9/6 Electrical characteristics Supply voltage Supply voltage tolerance, value, unit i50 VDC ± 0 % i500 / 00-P-90058-EN-0/05.06

. Schematic ivalve Z Z 9 C 6 P U 8 Q U A D T U 7 5 00 P 00709 P T Item Item Main spool Pressure relief valve Ball valve Pilot operated check valve 5 Emergency stop DOWN valve (UCM / A) 6 Piston-creep prevention 7 Hand pump 8 Pressure relief valve in the hand pump 9 Pressure gauge C P T Z Z icon (included in the delivery) ibox Pump Tank Hand pump Cylinder Test port 00-P-90058-EN-0/05.06 /

. Performance graphs Legend 500 mm /s (cst) Motorex Corex HLP 6 at approx. C 75 mm /s (cst) Motorex Corex HLP 6 at approx. 0 C.. ivalve 50 Δp = f (Q) Pressure drop - Flow rate characteristic [i50/60] (min. dynamic pressure/flow rate) Δp [bar].5 ivalve-50_p0.ai Δp = f (Q) Pressure drop - Flow rate characteristic [i50/50] (min. dynamic pressure/flow rate) Δp [bar].5 ivalve-50_p0.ai 0 Down (Z-T) 0.0 Down (Z-T) 7.5 7.5 5.0.5 Up (P-Z) 5.0.5 Up (P-Z) 0 0 0 80 0 0 60 Q [l/min] 0 60 75 90 05 0 5 50 Q [l/min].. ivalve 500 Δp = f (Q) Pressure drop - Flow rate characteristic (min. dynamic pressure/flow rate) Δp [bar] 9 ivalve-500_p0.ai 8 7 6 5 0 50 50 50 Down (Z-T) Up (P-Z) 500Q [l/min] / 00-P-90058-EN-0/05.06

.5 Dimensions, interface ivalve i50.5 59. 5 A-A 5 Z (G/ ) 7. 67.6 0.6 5.5 87.5 507 P (G ) T (G ). 5 B-B 95 00--00900 Low-mounting connection see Figure A-A Pipe-mounting connection see Figure B-B A-A 60 60 B-B 5 ø ø P T 7 09 (7) 7 5 6.5 00-P-90058-EN-0/05.06 5/

.6 Dimensions, interface ivalve i500 9 (90) Z (M5x) 7 (66) A-A (G½) P T (G½) 8.75 B-B 7 97 75 00-P-0087-0-B Low-mounting connection see Figure A-A Pipe-mounting connection see Figure B-B 9.7 7 7 A-A B-B 70 00 7 7 00 P T 00-P-0087-0-B.5 6/ 00-P-90058-EN-0/05.06

.7 Application examples The lift-control valve is an electronically controlled hydraulic valve block for controlling hydraulic-powered passenger and goods lifts. The lift-control valve is situated on a hydraulic power unit and activated by a lift control system..8 Model code ivalve IVALVE - 50 / 60 Rx.x IVALVE = Intelligent lift-control valve 500 = Nominal size 500 50 = Nominal size 50 500 = Flow rate 500 l/min (nominal size 500) 50 = Flow rate 50 l/min (nominal size 50) 60 = Flow rate 60 l/min (nominal size 50) R.0 = Release / Design stage Electronic card for lift-control valve icon Potential-free switching output for faults Two configurable switching outputs (pressure switch, train speed supervision) Functions can be expanded via options board. icon The ivalve lift-control valve is an electronically controlled hydraulic valve block for controlling hydraulic lifts. The electronic control is accomplished by an electronic unit the icon that is housed in the control cabinet. In operation, the electronic controller regulates the states Travel UP and Travel DOWN, and the transitions between these states. In the electronic unit, this travel is represented in a form known as travel curves. During operation, the travel curves for that particular lift are optimised by the learning algorithm "iteach". The ParamCard is a memory card on which the system-specific parameters and data are stored. The ParamCard plugs into the icon. Without the ParamCard being plugged in, no lift travel can be carried out. 00-P-90058-EN-0/05.06 7/

. Technical data General characteristics Designation Design Electrical connection Mounting method icon Mounting method Weight Ambient temperature range Relative air humidity Dimensions (overall sizes W x H x D) Supply voltage Supply voltage tolerance Max. ripple - solenoids - electronics, value, unit icon Printed circuit board with layers -pin square plug to ISO 00 / DIN 650 PCB connector.5 / 5 mm (screw terminals) Plug connector kit available - see the chapter Accessories 5/5 mm cap rail acc. to EN 5005 (G) or EN 500 (TS5, TS5) Option boards spacer studs Mx6 (included in delivery) 0.0 kg + C +0 C 0 90% (without condensation) x x 6 mm (without options board) VDC ± 0 % 50 mv pp max. (ripple and noise) Power consumption at max. control current Command inputs Switching outputs Relative duty cycle Max. Nominal power consumption at standstill Relay contact rating: Min. control current Max. voltage Max. power 50 W (i50) 0 W (i500) active / + V active (configurable) Potential-free relay contacts 00 % W 0 ma / max. A 50 VAC 750 VA (AC) / 90 W (DC) Electromagnetic compatibility: interference immunity EN 06 Electromagnetic compatibility: interference emission EN 05 Protection class to ISO 0 65 / EN 60 59 IP 00 8/ 00-P-90058-EN-0/05.06

. Block diagram Lift control system (customer s) + V DC X X7 +V DC PE icon ParamCard K 6 K 5 X8 K K K5 K6 X6 5 6 k5 +V DC 0,7A 7W +V i50 i500 +V DC +V DC. A.0 A 0W K7 7 K8 8 +V * ** Monitoring SMA X0 +SMA (V DC) (0.A) +V X5 m0 m0+ m m+ NR NR FR FR X 5 6 nc error no nc s no Switching output Relay fault / SIU Switching output Relay s ye gn br wt ivalve 7 8 9 nc s no Switching output Relay s Solenoid UCM / A Solenoid UP /DOWN travel (black plug) (grey plug) ibox X com/meas Handterminal / PC X RS 00 P 0076 0 * Configurable via software, -active/ +V-active (applies to all inputs K... K8) * Configurable via software, -active/ +V-active (applies to all inputs K... K8) 00-P-90058-EN-0/05.06 9/

. Dimensions.. Electronic card icon basic board 6 00 min.60 05 00 ~7 G EN 5005 ~ TS5 EN 500 06 00 P 0090 00.. Electronic card icon with options board ( additional switching outputs) 70 56.8 50 0.8 8 59 7 G EN 5005 TS5 EN 500 00-P-0090-00 0/ 00-P-90058-EN-0/05.06

.5 Pin assignments icon electronic card basic board X8 X0 X7 X6 X5 X X0 X7 X6 X5 X pwr run up down misc. X8 +SMA 5 6 7 8 + + m0(9) m(0) com/meas X X9 card X RS X9 ok C0 select X +V DC PE error s s X errror s s 00 P 0090 00 X X Item Item ParamCard Top-hat rail TS5, TS5 (EN 500) or G-type rail G (EN 5005) X X X X Connector block power supply Connector block switching outputs Connection Handterminal / PC Connection ibox X5 X6 X7 X8 X9 X0 Connector block solenoids Connector block command signals K6 K8 Connector block command signals K K5 Socket for ParamCard Socket for options boards Connector block, SMA IMPORTANT!: Two independent switching outputs are available on the icon. For each switching output, a relay (s and s) is available, each with a break/make contact. IMPORTANT!: K coding and binary coding are possible. For other information, please contact BUCHER! 00-P-90058-EN-0/05.06 /

.5. Options board, switching output Options board for version with pressure switch X50 X50 X0 X0 X S S 00-P-0090-0 Item Item X-0 Connector block, switching outputs X-50 Socket for options board X- Not used / 00-P-90058-EN-0/05.06

.6 Dummy icon optional.6. The "Dummy icon" can be pre-installed in the control cabinet as a "placeholder" instead of the real icon (control electronics for the ivalve). It has all the plug connectors that the icon has, so that the wiring can also be done in advance (cable lengths and cable positions)..6. How customers contact the test system The central "X" plug offers an additional benefit. All signals that are wired from outside to the icon are available on this plug. Consequently, the wiring can be checked with an automatic test system..7 Accessories Part No. 00709906 Dummy icon 00700+ Handterminal including connecting cable 0070007+ PC software "iwin", including connecting cable 00700+ Power supply module i50 0070+ Power supply module i500 0070000+ Plug connector kit 007007+ 000008998+ 00000900+ Solenoid connection cable:.5 metre 6.0 metre metre (for Halogen-free versions, contact Bucher) 007096+ 0070060+ 007006+ ibox connection cable:.5 metre 6.0 metre metre Related documents Reference 00-D-9005 00-I-9005 00-I-9005 00-S-9007 00-S-90058 Planning information ivalve Commissioning and maintenance ivalve Parametrization and maintenance ivalve Spare parts ivalve / icon i50 Spare parts ivalve / icon i500 info.ch@bucherhydraulics.com www.bucherhydraulics.com 06 by Bucher Hydraulics AG, CH-65 Neuheim All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 0.0.500.. 00-P-90058-EN-0/05.06 /