Heat recovery unit WHR 930

Similar documents
Installation and maintenance instructions. Danfoss Vent

ComfoAir 550 Luxe Manual

ECOCIAT. Domestic hot water heat recovery unit

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

ComfoAir 350 Luxe User Manual

Zehnder Focus 200. Ventilation device

HRU ECO 4. Installer manual

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

Flexit air handling unit K2 R

squrboxbox heat recovery squrboxbox I technical information

CE6500 Energy Recovery Ventilator

121MC. Vallox. Low-energy ventilation unit with heat recovery. Operating, maintenance and technical instructions. Vallox EN 14.5.

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Combi Unit Genius. The energy efficient Building Service Centre

RPV - RP - RA air handling units

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

94122E FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK

Installation, operation and maintenance manual TX 35A

KONRAD. Hybrid Fancoil Series

The compact unit series

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood

CADB and CADT-D / DI / DC Series

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating


8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Heat Recovery based on Exhaust Air

Under sill units. Type FSL-B-ZAS

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Brochure EX

Accessory Manual Ventilation Section Model Comfort Circle

FLEXIT S4 R S6 R S7 R

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

HEAVY DUTY STORAGE GAS

HVAC Processes. Lecture 7

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

IH E Sigma Island 90

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SERVER ROOM CABINET INSTALLATION CONCEPTS

TFSR & TFSK Roof Fans

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Electric Rotary Actuator - On/Off or programmable control actuator

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

Delivering exceptional performance and Ecovalue. Ecocent

Ventilation Solutions Kitchens. fantech

Flexit Central Vacuum Cleaner

USER S MANUAL HSC-24A

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

SWIMMING POOL HEAT PUMP Owners Manual

Topvex SX/C, Topvex TX/C. Air Handling Unit

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

Split units TH with hermetic compressors

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HRU ECO 4 Technical Guide

OPERATING AND MAINTENANCE MANUAL

UDSA - UDSBD unit heater

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Supply air diffuser ROKA/RPKA

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

york air-conditioning products Residential & VRF News 2015

Cooking at the Speed of light!

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

FOXAIR 60/50 ALL MODELS

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

RRV934. Multi-controller. Synco living

Flexit Central Vacuum Cleaner

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Lesson 36 Selection Of Air Conditioning Systems

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

- White Paper - Data Centre Cooling. Best Practice

How To Get A Passive House

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Important Safeguards

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

2014 British Columbia Building Code Changes

LG Electronics AE Company, Commercial Air Conditioning

save water, save money, save the environment Monsoon domestic rainwater harvesting systems

Mitel DECT Base Stations

Transcription:

Important features EPC gain of up to 0.28! High thermal efficiency 100% bypass fitted as standard Air capacity 380m³/h - 1150Pa Flexible filter settings Standard with frost protection system With maintenance instructions for resident Available in radiographic version RF Available with switch including filter and malfunction alert Free filter set for residents General The heat recovery unit, type WHR 930, is intended for application in residential 'Balanced ventilation systems' These systems extract the stale air from kitchens, bathrooms, toilets and other rooms where necessary. Fresh outdoor air is supplied to living areas, such as living rooms and bedrooms. Heat transfer takes place between the extracted air and the supplied air. The RF type is available for radiographic control of the unit. Casing The casing is made of coated plate with a plastic designer front panel (RAL 7037). The interior and the duct connections are made of highgrade expanded polypropylene. The has 4 air connections (Ø 150 mm) positioned at an angle of 45. These connections are fitted with 45 bends which can be individually directed upwards or sideways. A plastic condensation drain, with a Ø 32mm connection, has been fitted to the bottom of the unit in order to drain any condensation which might form in the unit and in the external air outlet. In order to prevent condensation, it is important to insulate the outdoor exhaust ducts and outdoor air ducts with damp-proof insulation. Fans The has low-energy continuously variable DC motors with backward-curved blades. These blades make the a low-maintenance unit. The DC motors offer a substantial energy saving relative to AC motors. Filters The is fitted with a G3 filter in both the supply and exhaust side. Both filters can be easily removed and changed by residents without tools. The unit has a flexible dirty-filter alert. Residents can set the unit according to whether they live in a rural, urban or normal area. This setting affects the frequency with which the filter registers as dirty. The fan's speed also influences the frequency with which the dirty-filter alert is activated. This alert is a signal to the resident to clean or replace the filters. Heat exchanger The high-quality plastic counterflow exchanger has a thermal yield of 95%. Frost protection system The is fitted with a frost protection system as standard. An automatic regulator activates a heating element when the outside temperature drops below the freezing point for some time. The cold outside air is then pre-heated before it enters the heat exchanger. This increases the temperature of the air to above 0 C so the heat exchanger is not subject to freezing. This system guarantees balanced ventilation up to a maximum of 150m³/h at -15 C. Display The WHR has a display with touch controls which allows for easy adjustment of the various settings and easy reading of data. This enables the resident to adjust the comfort temperature and the dirty- 1

filter alert, for instance. Regulation The 3 speeds can be variably set, from 15 to 100%. The 3-position switch SA 1-3V or the switch on the non-powered extractor hood or the ExSense hybrid chimney is used to switch the between high, medium or low. A 3-position switch with a malfunction and filter indicator is also available (type SAI Flash). The radiographic control (RF type) allows for cordless operation of the unit. Air direction/connection L = Residential Connection Left (condensation drain bottom right) R = Residential Connection Right (condensation drain bottom left) roof (right) dwelling modern stainless-steel chimney combines central extraction and recirculation. Selecting the chimney with connection box offers even greater ease of operation, as the WHR system automatically switches to its highest setting as soon as ExSense is in use. Electrical connection The is fitted with a 5-core cable and Perilex plug as standard, for connection to single-phase 230 V, 50 Hz. Length of free cable is 2.3 metres. Options Radio control: RF The is available in a radiographic control version: WHR 930 RF. This version offers even greater ease of operation. This cordless method of operating the unit with the RFZ prevents the installation of a separate electrical system in addition to the existing channels. This allows for the use of multiple RFZ switches. The RFZ is fitted with filter and malfunction LED indicators. These light up the moment the switch is operated. Base The can be mounted on the wall or fitted free-standing. A special base is available for this purpose. dwelling (left) roof Extractor hood It is not possible to connect a powered extractor hood to the WHR system. The solution is the WK non-powered extractor hood or the ExSense hybrid chimney. This Pulse switch The WHR can be set to 'high' for a certain length of time by the inclusion of a pulse switch in the bathroom. The duration can be set on the display. The pulse switch is connected to the WHR via a 2-core low-voltage cable. Dimensions The figure on the following page gives the dimensions in mm. 0.1. 2

0.1 3

Position Setting Capacity Pressure Consumption Consumption Cos Noise level Weight percentage Qv Pst power current Exhaust db(a) Inlet db(a) % m³/h Pa Wel A (-) db(a) db(a) kg (1) 15 100 20 10 0.08 0.50 37 45 35 (2) 30 140 40 17 0.13 0.57 43 53 (3) 40 180 65 27 0.21 0.56 47 59 (4) 50 225 100 44 0.35 0.55 52 64 (5) 60 260 140 70 0.55 0.55 54 68 (6) 70 300 175 105 0.81 0.56 57 71 (7) 80 325 215 145 1.00 0.58 59 74 (8) 90 350 240 196 1.42 0.60 61 75 1000 Pa 900 800 700 600 500 400 300 200 100 1 2 3 4 5 6 7 8 0 60 120 180 240 300 360 420 480 540 m³/h 0 17 33 50 67 83 100 117 133 150 l/s 4

Sound Fan Sound capacity db ref. 10 ¹² W Type Level 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 1 56 50 41 34 23 13 13 2 60 60 50 44 35 26 12 3 66 65 56 51 43 35 22 4 71 69 62 56 49 42 30 5 75 71 66 61 54 47 35 6 77 74 69 64 58 52 40 7 78 76 72 68 61 55 43 8 79 76 74 69 62 57 45 5

Accessories and controls For accessories and controls, please refer to the relevant chapters. A summary is given below in the form of a table. Accessorries page Non-return damper (RSK 150) 495 Ventilation valves for air supply (STH) 505 Ventilation valves for air exhaust (STB / overspraakdemper SGD) 509 Ventilation valves for air exhaust (STC / overspraakdemper SGD) 513 Ventilation valves for air exhaust (STK) 515 Ventilation valves for air exhaust (STV) 519 Kitchen box (SKB) 523 Noise-proofing hose (SFD) 523 Non-powered extractor hood (WK) 525 Hybrid 'chimney' (ExSense) 527 Controls page Radio control (RFZ) 465 Position switch (SA 1-3V, SAI Flash, pulsschakelaar) 467 6

703 Perilex 7

8