General Specifications for Soft Starter.

Similar documents
Bulletin 150 SMC Flex Smart Motor Controller Specifications

Panorama. Softstarters The complete range

BIG SAVINGS FOR A LOT MORE APPLICATIONS

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

PSR The compact range Description

32VFD Variable Frequency Drives for Centrifugal Chillers

Phone: Fax: Web: info@clrwtr.com

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

Softstarters. Type PST30...PSTB1050 Installation and Commissioning Manual. Manual 1SFC132003M0201 June Fault. Power on Protection

MOTOR CONTROL IS OUR NATURE

... Electronic Softstarter...

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

3753 en /b VE/B - VE/RG Va V riable speed drives

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

Softstarters Type PSR

Torque control MSF Softstarter

Number 1 in efficiency

Installation and Maintenance manual. Softstarters PST / PSTB

GE Industrial Solutions ASTAT BP. User Manual

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB. Latest updated not printed, only in PDF-format

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Thyristor-controlled power supplies and battery chargers

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Phone: Fax: Web: info@clrwtr.com

Softstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU SFC132070M0201 February SFC132070M0201 1

Power Supplies 3. SDN-P DIN Rail Series

Specifying a Variable Frequency Drive s

Softstarters Type PSE18...PSE370 Installation and commissioning manual

DLP-PU/E Instruction Manual

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

PUMP CONTROL. AC Variable Speed Drive PUMP CONTROL. Energy efficient pumping with. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

VLT 6000 HVAC. Contents

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Easy to connect - Easy to configure Easy to install

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

Products and solutions for lifting systems

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

NX Series Inverters. HVAC Pocket Programming Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Analog Servo Drive 25A8

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Brushless DC Motor Controller Product Specification Assembly 025F0129

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

A1000 Cheat Sheet (Open Loop Vector)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Principles of Adjustable Frequency Drives

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

38 Series - Relay interface modules A

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

RVS-DX Instruction Manual

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Frequency Converter Fv

Softstarters. Index. 5 - Softstarters. Phone: Fax: Web: info@clrwtr.com.

Rack mounted telephone- and leased line modem for industrial applications

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

SECTION VARIABLE FREQUENCY DRIVES

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Discover the power of e-learning! The Quick Guide to AC Variable Frequency

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

SMC FLEX QUICK START BULLETIN 150

38 Series - Relay interface modules A

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Products and solutions for pumping, irrigation and piping

HVAC BUILDING SERVICES

DC Motor control Reversing

Antec TruePower User's Manual

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

NC-12 Modbus Application

Duct Humidity Transmitter

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

What Is Regeneration?

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RVS-DXM Instruction Manual

, User s Manual

SYSTEM 4C. C R H Electronics Design

CompactLogix Power Supplies Specifications

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Transcription:

1.01 SOFT STARTER: General: General Specifications for Soft Starter. This specification describes the requirements for a solid-state torque controlled starter (Controller) used to provide linear ramp starting and stopping of three-phase AC induction motors. The requirement is for a stand-alone unit that negates the need for further equipment in terms of protection, viewing and controlling. A. Electrical ratings a) 200 525 +/- 10% 200-690 +5%/- 10% Volts AC mains b) 50-60 Hz +/- 10% c) 100-240/380-500 +/- 10% Volts control voltage B. The Controller shall provide as standard, the following starting modes: a) Linear Torque control for Start b) Quadratic Torque control for Start c) Pump Control d) Current Limit Start e) Voltage ramp Start f) Voltage ramp with current limit Start g) Full Voltage DOL Start h) Remote analogue control i) Soft Start with Selectable Torque Boost j) Slow Speed time controlled k) Slow Speed external controlled l) Dual Ramp Start m) Bypass control C. The Controller shall provide as standard, the following stopping modes: a) Linear Torque control for Stop b) Quadratic Torque control for Stop c) Pump Control d) Voltage ramp Stop e) DOL/Coast to stop f) Remote analogue control Stop g) Dynamic DC-Brake and Soft brake (reverse brake) h) Slow Speed time controlled i) Slow Speed external controlled j) DC-Brake at slow speed k) Dual Ramp Stop

l) Accurate positional stop control m) Bypass control D. The Controller shall provide as standard, the following Additional features a) Jogging forward and reverse b) 4 parameter sets c) Analog output d) Built in Display E. The Controller shall provide as standard, the following Operation features a) Keyboard b) Remote F. The Controller shall provide as standard, the following Protection features: a) Motor Thermal Overload b) Soft Start thermal overload c) PTC input d) Motor Shaft Torque (Max) machine process protection. e) Motor Shaft Torque (Min) machine process protection. f) Phase imbalance g) Phase reversal h) Over voltage i) Under voltage j) Locked Rotor k) Excessive Starts per hour for application l) Phase loss input / output m) Motor output loss G. The Controller shall provide as standard, the following Viewing functions: a) Three Phase Current b) Three Phase Voltage c) Current in L1, L2, L3 d) Voltage between L1-L2, L1-L3, L2-L3 e) Shaft Power in kw / HP (selectable) f) Motor thermal capacity g) Motor Energy consumption (kwh) h) Power factor i) Run time in hours j) Torque in Lbs./ft or Nm (selectable)

H. The Controller shall provide as standard, the following Fault Indication functions: 1.02 CONSTRUCTION: a) Line failure n) Phase imbalance b) Over temperature motor c) Over temperature Soft Starter d) Shorted Thyristor e) Open Thyristior f) Locked Rotor g) Motor output loss h) Overload - Shaft Torque i) Underload Shaft Torque j) Phase imbalance k) Over voltage l) Under voltage m) Excessive Starts n) Phase reversal o) Event List of 15 latest fault indications/occurrence a) The Controller shall be of modular construction, consisting of a Power Control Board (PCB) and Power Structure. b) The PCB shall be compatible the full range of power structures. c) In the sizes from 17-1400 Amps all phases should be controlled during start/stop. d) The power structure shall consist of six SCR s mounted on a heatsink for ratings up to and including 1400 Amps. e) The Controller shall be DIN Rail mountable up to 250 A. f) DIN Rail mountable units should be mountable without space at side. 1.03 CODES AND STANDARDS: The controller shall be designed to meet the applicable requirements of: a) EN 60204-1, EN 50081-1 (-2 from 170 A) EN 50082-2 b) IEC 947-4-2 c) UL 508 d) cul 1.04 CONTROL MODULE DESIGN FEATURES: A. MECHANICAL:

a) The PCB module shall consist of a power supply, logic control circuitry, silicon controlled rectifier (SCR) firing circuitry. I/O circuitry, a digital programming keypad, dual LED Displays and a serial communication port. b) The PCB shall be designed for integral mounting on the power structure and shall be compatible with the full range of current ratings- 17 Amps to 1400 Amps. c) The PCB shall be easily removed from the power structure, without the need to disassemble associated printed circuit board assembles. d) Control terminals shall be easily accessible and located on the front bottom of the device. The terminals shall be UL rated for 300 Volts, 15 Amps maximum and accept a maximum of two wires, 0,2-4mm 2 (#30-#12 AWG). e) Digital parameter adjustment shall be provided through a built-in keypad. Analog potentiometer adjustments are not acceptable. f) Dual built-in alphanumeric, LED displays shall be provided for controller set-up, diagnostics, status and monitoring. The Control Keypad and Display shall have the option for remote mounting. g) For safety reasons the controller should have 2 green lights for running and start/stop. B. ELECTRICAL: a) The PCB shall provide digital microprocessor control and supervision of all controller operation, including SCR pulse firing control. b) The PCB power supply shall be self-tuning to accept control power input from 100 to 240 or 380 to 500 VAC, 50/60 Hz. c) The SCR firing circuitry shall incorporate an RC snubber network to prevent false SCR firing. d) The logic circuitry shall incorporate a latch circuit for three-wire control. e) Reverse operation of the motor shall be standard in the jog mode without the use of a reversing contactor.

C. USER ADJUSTMENTS: a) The two acceleration start ramp timers shall have individual adjustments from 1 to 60 seconds. b) The two acceleration stop ramp timers shall have individual adjustments from 2 to 120 seconds. c) The initial torque setting shall be adjustable from 0 to 250% of motor torque. d) The end torque setting shall be adjustable from 50 to 250% of motor torque. e) Current limit starting shall be adjustable from 150% to 500% of the motor s full load current. f) Slow speed shall be adjustable up to 60 seconds or up to 100 external pulses. D. PROTECTION AND DIAGNOSTICS: a) Overload protection shall be as follows: 1) Meets applicable standards as a motor thermal protection device. 2) Shaft Power measurement without the use of external electromechanical sensors. 3) Electronic thermal memory shall be provided for enhanced motor protection. 4) Shaft Overload and Underload protection shall be available through the controller, even in a bypass configuration. 5) Protections should be available if bypass is made. b) When fault conditions are detected, the controller shall inhibit starting or shut down SCR pulse firing. E. PUMP CONTROL (standard feature): a) The standard feature pump control shall be implemented to provide closed loop control of a motor to match the specific torque requirements of centrifugal pumps for both starting and stopping. This shall aid in eliminating the phenomena commonly referred to as water hammer. Methods utilizing Soft Start with Soft Stop shall not be

acceptable. The soft start and soft stop programming should be independent of each other. b) Pump stop shall be initiated without the need for a dedicated Pump Stop input. A coast-to-rest stop shall still be possible with a stop input. c) The Pump Stop times shall be user adjustable from 0 to 120 seconds. F. POWER STRUCTURE DESIGN FEATURES: Electrical: a) Back-to-back SCR pairs shall be the only power-switching semiconductor means acceptable. Diode0SCR combinations shall not be acceptable. b) There shall be separate power sections to operate from 200V to 525 V and 200V to 690V, 50/60 Hz. c) Semi conductor fuses should not be required for warranty in sizes17-1400 Amps. d) Softstarter should be built for continuous operation without need of by pass for any reason. e) SCRs shall have the following minimum repetitive peak inverse voltage ratings: 1. 200 to 525V: 1600 V 2. 200 to 690V: 1800V Transient Protection: 17 Amps to 1400 Amps a) For controllers rated 17 Amps to 1400 Amps, transient protection with snubber circuit including RC-net shall be standard. b) Capacitors against electrical noise should be integrated as standard. G. ENERGY SAVER: a) The Energy Saver feature shall operate to automatically cause the output voltage from the controller to be reduced when a motor is unloaded or lightly loaded. b) Customer adjustments shall not be required.

c) The Energy Saver feature shall be defeatable. d) Additional mounting space or wiring shall not be required. H. ENVIRONMENTAL RATINGS: a) Temperature Ratings 1) The Controller shall deliver its rated current in ambient temperature ranging from 0. C to +50 C. 2) The controller should be able to operate up to 50 C. 3) The ambient storage temperature shall range from 25 C to +70 C. b) Humidity Range 1) The controller shall be operable in relative humidity of 5 to 95%, non-condensing. c) Altitude Rating 1) The controller shall be suitable for operation up to altitudes of 1,000 meters without derating.