Tel.X Ni-Cd battery. The compact solution for stationary applications



Similar documents
Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Saft stationary batteries. A wide offer of reliable, long-life solutions

Sunica.plus Ni-Cd batteries. The robust daily cycling solution for off-grid solar PV systems

Saft railway batteries. Solutions for a world in motion

Evolion Li-ion battery. Saft s proven ultra-compact solution for telecom applications

Optimising the daily operation of industrial trucks

How To Make A Train Power Battery System For The Railways

Saft Li-ion battery systems for hybrid and electric vehicles. Increasing energy efficiency and meeting environmental challenges

Energy Storage Systems. New solutions for a new energy environment

Intensium Max. A range of ready-to-install containerised energy storage for renewable energies and grid management

ULM Ultra Low Maintenance batteries for aircraft. Because you have a choice.

SPH Ni-Cd battery Instant power

Saft Reliable energy for the internet of things. A wide range of energy solutions for sensing devices

Carefree Sealed Lead Acid (SLA) MSDS

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

Height w/o Terminals (in)

Height w/o Terminals (in)

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

Thyristor-controlled power supplies and battery chargers

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate

Remote Power Systems

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

MPR-Systems. Mini Power Racks 1200 W W

LEAD ACID BATTERY working LIFETIME STUDY

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

Eaton 93PM UPS Where aesthetics meet intelligence.

Industrial Batteries North America

Stationary Storage Battery Systems

LITHIUM-ION ENERGY MODULES HEM & HPM SERIES

NP Series VALVE REGULATED LEAD-ACID BATTERIES

Battery Technology for Data Centers and Network Rooms: Lead-Acid Battery Options

SELECTION GUIDE FIFTH EDITION

Product Environmental Profile Step Down Transformers

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

SMART SHELTER CONTAINER

Industrial Batteries Network Power Sonnenschein Solar Safe storage capacity for renewable energy. Specifications

Comparative study for cables and busbars

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

RiMatrix S Make easy.

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

Thermal Optimisation in the Data Centre

SODIUM-METAL HALIDE BATTERIES FOR STATIONARY APPLICATIONS

Industrial Batteries System solutions for railways.

Phase Modular Finally the benefits of Modular ups are for all

OPzS Vented Lead-Acid STANDBY POWER BATTERIES

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Mixing Sodium and Lead Battery Technologies in Telecom Applications

9244 Balboa Avenue, San Diego, CA CH1728 Rossens

Secondary Unit Substations

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

EXCERPT - THE DATA CENTER BATTERY DILEMMA

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

The Future of Battery Technologies Part I

1.1 ANNUAL PREVENTIVE MAINTENANCE VISIT

EssPro Energy Storage Grid Substation The power to control energy

875 Dearborn Drive Columbus, Ohio Tel: (614) Fax: (614)

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

ROTEX gas hybrid heat pump. A strong team.

UPS Topologies & Architectures. Don Lemmon Tubbesing Solutions (214) don@tubbesing.com

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

IntesisBox KNX LG Air Conditioning

Krav til sikkerhed for sekundære batterier og installationer af batterier Del 2: Stationære batterier

Eaton 93PM UPS Efficient. Scalable. Innovative.

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

READING DEVICE US-05

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

30W SOLAR CHARGING STATION

Digital input modules

EGSTON Standard E2xFxWx 12W

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Power distribution in data centres

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

Substation Battery & Charger Maintenance

When Do Solar Electric & Utility Back-Up Systems Make Sense?

Remote Monitoring and REC 501 Control Unit Product Guide

HIGH FREQUENCY RECTIFIERS 24 & 48 VDC

Telephone- and leased line modem for industrial applications TD-36

4.0 UPS dedicated to ICT for unmatched energy savings

The Quality Connection. BETAflam Fire Resistant Safety Cables

Sony s Energy Storage System. The Sony Lithium Ion Iron Phosphate (LFP) advantage

2. Add the following definitions to 3.3 General Definitions and renumber 3.3 as required:

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Technical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

IT S TIME TO EXPECT MORE FROM AN ENERGY STORAGE SOLUTION

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

DIGITUS Network & Server Cabinets. UNIQUE Series

PX100 MBP with Configurable Distribution

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Transcription:

Tel.X NiCd battery The compact solution for stationary applications

Tel.X, delivering highenergy performance in a compact maintenancefree package Tel.X: guaranteed power continuity for remote or hard to access installations Tel.X delivers exceptional reliability to offer effective insurance against unexpected outages for industrial installations where continuity and reliability of power supplies is an absolutely critical factor, such as oil & gas exploration and production, utilities and manufacturing plant. Tel.X is especially suited for remote and/or decentralized locations where travel time and restricted access demand an optimized maintenance regime and guaranteed performance to ensure quality of service. Typical Tel.X applications include supporting vital control and instrumentation systems in onshore and offshore oil & gas facilities for outdoor or indoor installations. Tel.X is also ideally suited for railway signalling and infrastructure applications, for trackside signals, switches, crossing control signals & barriers and other equipment both to guarantee public safety and ensure the effective control of trains and other traffic on highway crossings. Tel.X s robust NiCd construction and engineered electrolyte ensure total reliability and a long, predictable service life. The Tel.X battery has a NiCd construction designed for more than 0 years service life at + 5 C (+ 77 F). Like any other battery, high temperature operation will reduce its life expectancy. For comparison, at + 35 C (+ 95 F), the lifetime reduction for a NiCd battery is 0%, while it reaches 50% for a leadacid battery. Percentage of +5 C (+77 F) lifetime 0 90 80 70 60 50 40 30 0 0 5 77 Effect of temperature on lifetime 30 35 40 45 50 86 95 4 113 1 Temperature Nickelcadmium Lead acid 55 131 C F Tel.X NiCd battery The compact solution for stationary applications

Tel.X, perfectly adapted for battery installations in tight spaces The Tel.X NiCd battery delivers the optimum combination of highenergy performance, reliability and longlife in a new compact, modular maintenancefree design that ensures the lowest possible TCO (Total Cost of Ownership). Thanks to its outstanding energy density of up to 0 Wh/l, Tel.X is the perfect direct replacement for VRLA batteries in stationary backup applications where limited space is available. Tel.X reduces battery weight by 30% in the same space. Reliable backup performance guaranteed even in extreme temperatures Tel.X offers the ideal combination of reliability, performance and longlife over a wide range of operating temperatures. Utilizes robust construction based on unique wellproven NiCd electrochemistry Eliminates the corrosion, sudden death and thermal runaway risks associated with VRLA batteries Combines superior performance with high charging efficiency Operates in temperatures from 0 C to + 50 C ( 4 F to + 1 F) and tolerates 50 C to + 70 C ( 58 F to + 158 F) for short durations Exceptional reliability removes the need for dualredundant systems Constant voltage recharge characteristics Current limit 0.1 C 5 A Temperature + 0 C to + 5 C (+ 68 F to + 77 F) Operating and maintenance requirements are reduced even for remote installations Tel.X s reliable maintenancefree design is perfectly adapted for difficult to access installations. Maintenance free design, with a low pressure venting system, reduces water consumption to an absolute minimum No topping up is necessary (in recommended operation) water addition is possible under exceptional circumstances Periodic checks of charging voltage are recommended, but Tel.X requires no further attention once installed Extended lifetime matches the stationary equipment it supports 0 90 Available capacities (% C5 Ah) 80 70 60 50 40 30 0 0 0 4 6 8 1 14 16 18 0 4 Recharge time (hours) 1.43 V/cell Tel.X NiCd battery The compact solution for stationary applications 3

Tel.X, for ease of installation and operation Easy installation makes Tel.X a simple and direct replacement Compact modular design makes Tel.X the ideal direct replacement for VRLA batteries in backup floating applications it fits easily within the available space and is fully compatible with existing equipment. Highly compact design optimizes: Volume: high energy density of up to 0 Wh/l Weight: 30 % lighter than VRLA Modular design suits specific capacity needs: From to Ah in modular block construction Each module comprises 3 to cells in flame retardant material Parallel assembly possible up to 4 strings Tel.X NiCd bat NiCd battery Layout provides easy access to front terminals Lifting handles on each module ensure easy handling and installation Can be assembled into standard stationary racks Designed for ease of operation Tel.X offers the ease of operation that contributes to a long and troublefree service life. Tel.X is compatible with VRLA charging systems thanks to its single step 1.43 V /cell floating voltage, with no need for temperature compensation Environmental protection for terminals and connectors is provided by a protection cover (meeting IP level against electrical shock according to safety standard EN 507/IEC 6485) Cabling is carried out from back to front, with front accessible connection points between adjacent blocks Active cooling is not required, even in harsh environments Central gas venting system option is available for use in enclosures without ventilation Tel.X batteries may be stored for up to one year without special maintenance before installation 4 Tel.X NiCd battery The compact solution for stationary applications

Tel.X, the sustainable battery solution Designed with sustainability in mind Tel.X is purpose designed for minimum environmental impact throughout its entire life cycle, from manufacturing to operation and recycling at endoflife. Tel.X manufacturing processes are designed to minimize consumption of upstream energy In operation, Tel.X contributes to a significant reduction in energy consumption throughout its service life Highly efficient charging reduces peripheral energy consumption, including cabinet air conditioning and maintenance Advanced design reduces the environmental impact of waste processing Fully conforms with quality, safety and environmental standards Meets the highest quality standards including: Electrical Certified IEC 6063 Secondary cells and batteries containing alkaline or other nonacid electrolytes Vented nickelcadmium prismatic rechargeable single cell Certified NF C 150 Lowvoltage electrical installations Safety EN 507/ IEC 6485 Safety requirements for secondary batteries and battery installations Part : Stationary batteries UL94 V0 UL standard for flammability safety of plastic materials for parts in devices and appliances testing Quality ISO 9001 and ISO 14001 Saft world class continuous program Environment Fully recyclable RoHS Although batteries and accumulators are not within the scope of the RoHS directive, Saft has taken voluntary measures to ensure that the substances prohibited by RoHS are not present in the battery, with the exception of the electrochemical core REACH The Saft Group has adopted internal procedures to ensure conformity with the European REACH (Registration, Evaluation, Authorisation and Restriction of Chemical Substances) Regulation Tel.X NiCd battery The compact solution for stationary applications 5

Tel.X Technical data Tel.X Physical properties Capacity mm Height in mm Width in Approx. weight per cell kg lb Internal resistance* mohm Cell connection bolt per pole TLX 0 3 15 54 54 54 54 5 5 5 5 4,13 4,13 4,13 4,13,,7 4,1 5,1 4,8 5,9 7,9,0,35 1,88 1,37 1,15 M6 M6 M6 M6 * Intercell connections included Length per block 3 cells 4 cells 5 cells 6 cells 7 cells 8 cells 9 cells cells TLX 0 17 154 09 50 5,0 6,1 8,3 9,9 166 0 76 331 6,6 8,0,9 13,0 06 51 34 411 8,1,0 13,5 16, 45 99 409 49 9,7 11,8 16,1 19,4 85 348 476 11,3 13,7 18,8 35 397 1,8 15,7 364 445 14,4 17,6 404 494 15,8 19,5 Flexible block assembly and configuration Tel.X batteries can be assembled either on shelves or into Saft s standard and seismic battery racks. The rack assembly method (with rows of Tel.X on each step) enables the installation to be optimised in terms of footprint and volume. For series connection on racks or on shelves, a block with an even number of cells should be selected to ensure short, straight, interblock connectors. If it is necessary to specify a block with an odd number of cells it should be placed at the end of a row. Block with an odd number of cells L(3) L(5) L(7) L(9) L(3) Block with an even number of cells L(4) L(6) L(8) L() L(4) 6 Tel.X NiCd battery The compact solution for stationary applications

Performance characteristics after prolonged float charge of fully charged cells Available Amperes at + 0 C ± 5 C (+ 68 F ± 9 F) Final voltage: 1.00 V/cell 8 5 Hours 3 1,5 1 TLX 0 3 15 7,9,3 14,9 18,3 9,9 1,8 18,5,8 15,3 19,7 8,5 35,1 4,7 3,0 46, 56,7 35, 45,6 66,4 81,6 46,5 60,0,8,0 58,0 73,9 1,0 13,0 Final voltage: 1.05 V/cell 8 5 Hours 3 1,5 1 TLX 0 3 15 7,8,1 14,6 17,9 9,7 1,6 18,,3 14,9 19,3 7,9 34, 4,0 30,9 44,3 54,5 33,7 43,7 63,0 77,4 4, 54, 76, 93,3 50,6 64,7 89,9 1,0 Final voltage: 1. V/cell 8 5 Hours 3 1,5 1 TLX 0 3 15 7,6 9,8 14, 17,4 9,3 1,1 17,5 1,5 14,4 18,6 6,9 33,0,5 9,0 41,6 51,0 31, 40,0 56,3 68,9 38,0 48,8 68,7 84,0 44,8 57,5 81, 99,5 Final voltage: 1.14 V/cell 8 5 Hours 3 1,5 1 TLX 0 3 15 7,3 9,5 13,7 16,8 9,1 11,8 17,0 0,9 13,7 17,7 5,6 31,5 0,7 6,8 38,4 47,1 7,5 35, 48,9 59,8 33,6 4,7 57,9 70,4 39,6 50,1 66,7 80,9 Tel.X NiCd battery The compact solution for stationary applications 7

Saft is committed to the highest standards of environmental stewardship As part of its environmental commitment, Saft gives priority to recycled raw materials over virgin raw materials, reduces its plants air and water releases year after year, minimizes water usage, reduces fossil energy consumption and associated CO emissions, and ensures that its customers have recycling solutions for their spent batteries. Regarding industrial nickelbased batteries, Saft has had partnerships for many years with collection companies in most EU countries. This collection network receives and dispatches our customers batteries at the end of their lives to fully approved recycling facilities, in compliance with the laws governing trans boundary waste shipments. This collection network meets the requirements of the EU batteries directive. A list of our collection points is available on our web site. In other countries, Saft assists users of its batteries in finding environmentally sound recycling solutions. Please contact your sales representative for further information. Saft 1, rue Sadi Carnot 93170 Bagnolet France Tel. : +33 1 49 93 19 18 Fax : +33 1 49 93 19 64 www.saftbatteries.com Document N 1816011 Edition: January 01 Data in this document is subject to change without notice and becomes contractual only after written confirmation. Photo credits: Saft, Fotolia. Attitudes design&communication C175 Printed on FSC paper by GMK, an Imprim Green member Saft Société par Actions Simplifiée au capital de 31 944 000 RCS Bobigny B 3 703 873