- Views:
Transcription
1 EaglePicher Technologies, LLC Commercial Power P.O. Box 47 Joplin, MO 6482 (417) Carefree Sealed Lead Acid (SLA) MSDS EaglePicher s Carefree lead acid batteries are sealed and do not require maintenance during long periods of operation. If you do not find what you are looking for or would like more information, please contact us. Click on Part Number to view data sheet. Carefree Sealed Lead Acid (SLA) Batteries Nominal Voltage Nominal 77 F Length (in) Width (in) Height w/o Terminals (in) Height w/ Terminals (in) Weight (lb) Part Number CF-12V33/C CF-12V33/U CF-12V4FR CFR-12V CFR-12V CFR-12V CFR-12V CFR-12V CFR-12V CFR-12V134
2
3
4 CF-6V33 CF-12V33/C Specifications CF-6V33 Nominal Voltage... 6V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (1.65 amps to 1.75 volts) ampere hours 1 Hour Rate (3.1 amps to 1.75 volts) ampere hours 5 Hour Rate (5.4 amps to 1.6 volts) ampere hours 1 Hour Rate (19 amps to 1.6 volts) ampere hours 1/2 Hour Rate (35 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (159mm) Width inches (85mm) Height (excluding terminals) inches (165mm) Height (including terminals) inches (171mm) Weight lbs (5.5kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods Float Charging: Constant Potential Source of 6.8 to 6.9 volts continuously. Routine Charging: Constant Potential Source of 7.25 to 7.45 volts with a charging current of 1 ampere maximum. Terminal: Standard is tin plated brass, positive terminal is.3 stock x.25 wide, negative terminal is.3 stock by.25 wide, mates with Amp Faston series or equal. Case Material: ABS 6.25 (159) 3.35 (85) (171) (165) Specifications CF-12V33/C Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (1.65 amps to 1.75 volts) ampere hours 1 Hour Rate (3.1 amps to 1.75 volts) ampere hours 5 Hour Rate (5.4 amps to 1.6 volts) ampere hours 1 Hour Rate (19 amps to 1.6 volts) ampere hours 1/2 Hour Rate (35 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (171mm) Width inches (159mm) Height (excluding terminals) inches (165mm) Height (including terminals) inches (171mm) Weight lbs (54kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 1 ampere maximum. Terminal: Standard is tin plated brass, positive terminal is.3 stock x.25 wide, negative terminal is.3 stock by.25 wide, mates with Amp Faston series or equal. Case Material: ABS 6.72 (171) 6.25 (159) 6.5 (165) 6.75 (171) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
5 2.7 Charge Voltage per Cell vs. Temperature CF-6V33 CF-12V33/C Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Deep Cyclic Charging Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) Typical Voltage Characteristic (7 F) DISCHARGE CURVE A 3.1A 1.65A A 3.1A 1.65A A 9. 19A A 35A 1 6 Volt Volt min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
6 CF-12V33/U1 Specifications CF-12V33/U1 Nominal Voltage V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (1.65 amps to 1.75 volts) ampere hours 1 Hour Rate (3.15 amps to 1.75 volts) ampere hours 5 Hour Rate (5.5 amps to 1.75 volts) ampere hours 1 Hour Rate (.6 amps to 1.6 volts)....6 ampere hours 1/2 Hour Rate (33.4 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (195mm) Width inches (13mm) Height (excluding terminals) inches (159mm) Height (including terminals) inches (18mm) Weight lbs (1.2kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 9.9 ampere maximum. Terminal: Standard is lead post, bolt and nut Case Material: ABS 7.68 (195) 5.12 (13) (18) (159) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
7 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CF-12V33/U1 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 33.4A.6A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 5.5A 3.15A 1.65A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
8 - + CF-12V4FR Specifications CF-12V4FR Nominal Open Circuit Voltage V Nominal Working Voltage V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (1.85 amps to 1.75 volts) ampere hours 1 Hour Rate (3.4 amps to 1.75 volts) ampere hours 5 Hour Rate (6. amps to 1.75 volts) ampere hours 1 Hour Rate (21. amps to 1.6 volts) ampere hours 1/2 Hour Rate (31. amps to 1.6 volts) ampere hours Max. Physical Size: Length inches (254mm) Width inches (97mm) Height (excluding terminals) inches (3mm) Height (including terminals) inches (3mm) Weight lbs (15.kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +16 F (-51 C to +71 C) Charge... F to +122 F (-18 C to +5 C) Recharging Methods: Float Charging: Constant Potential Source of to volts continuously. Routine Charging: Constant Potential Source of 14.7 to 15. volts with a charging current of 13.5 ampere maximum. Hardware Package: Two 1-32 x 1/2" Lg. 1mm Hex Head Bolts; Two No. 1 Flat Washers, and Two No. 1 Split Ring Lock Washers - all are Stainless Steel. Terminal: Lead plated copper insert threaded for 1-32 bolt. Flame Arrestor - Polypropylene 1. cu ft/min (27l/min) Case Material: Polycarbonate Flame Class: UL94 V-O Limited Oxygen Index: 35% Float Life Expectancy: 8+ years at 77 F (25 C) 1% Capacity Screened and Matched Two Year Full Warranty at average battery temperature of 77 F (25 C) or less 1. (254) 8. (3) 3.8 (97) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
9 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CF-12V4FR Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 31.A 21.A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 6.A 3.4A1.85A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
10 CFR-12V38 Specifications CFR-12V38 Nominal Voltage...12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (2. amps to 1.5 volts) ampere hours 1 Hour Rate (3.72 amps to 1.5 volts) ampere hours 5 Hour Rate (6.8 amps to 1.2 volts) ampere hours 1 Hour Rate (23.2 amps to 1.2 volts) ampere hours 1/2 Hour Rate (42. amps to 1.2 volts) ampere hours Max. Physical Size: Length inches (197mm) Width inches (165mm) Height (excluding terminals) inches (17mm) Height (including terminals) inches (17mm) Weight lbs (13.6kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.5 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 15. volts with a charging current of 16. ampere maximum. Terminal: Standard is bolt and nut (M5) Case Material: Flame Retardant ABS 7.76 (197) 6.5 (165) 6.69 (17) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
11 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V38 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 42A 23.2A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 6.8A 3.72A 2.A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
12 CFR-12V55 Specifications CFR-12V55 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (2.75 amps to 1.75 volts) ampere hours 1 Hour Rate (5.3 amps to 1.75 volts) ampere hours 5 Hour Rate (9.1 amps to 1.6 volts) ampere hours 1 Hour Rate (34 amps to 1.6 volts) ampere hours 1/2 Hour Rate (58 amps to 1.6 volts) ampere hours Max. Physical Size: Length inches (236mm) Width inches (132mm) Height (excluding terminals) inches (5mm) Height (including terminals) inches (235mm) Weight lbs (18kg) Energy Density ( Hour Rate): watt hrs/cu in ( Hour Rate): watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.5 to 14.9 volts with a charging current of 18. ampere maximum. Terminal: Standard is lead post, bolt and nut Case Material: Flame Retardant ABS 8.74 (222) 9.29 (236) 5.2 (132) 8.7 (5) 9.25 (235) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
13 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V55 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 58A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 34A 9.1A 5.3A 2.75A 4 o F 4 o C
14 CFR-12V65 Specifications CFR-12V65 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (3.25 amps to 1.75 volts) ampere hours 1 Hour Rate (6.2 amps to 1.75 volts) ampere hours 5 Hour Rate (1.6 amps to 1.75 volts) ampere hours 1 Hour Rate (4.2 amps to 1.6 volts) ampere hours 1/2 Hour Rate (68 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (355mm) Width inches (167mm) Height (excluding terminals) inches (179mm) Height (including terminals) inches (183mm) Weight lbs (22.2kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 19.5 ampere maximum. Terminal: Standard is tin plated brass, bolt and nut Case Material: Flame Retardant ABS (355) 6.57 (167) (183) (179) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
15 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V65 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 68A 4.2A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 1.6A 6.2A 3.25A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
16 CFR-12V7 Specifications CFR-12V7 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (3.5 amps to 1.75 volts)... 7 ampere hours 1 Hour Rate (6.56 amps to 1.75 volts) ampere hours 5 Hour Rate (11.5 amps to 1.75 volts) ampere hours 1 Hour Rate (43.2 amps to 1.6 volts) ampere hours 1/2 Hour Rate (72 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (258mm) Width inches (166mm) Height (excluding terminals) inches (6mm) Height (including terminals) inches (235mm) Weight lbs (24.kg) Energy Density ( Hour Rate): watt hrs/cu in ( Hour Rate): watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 18. ampere maximum. Terminal: Standard is lead post, bolt and nut Case Material: Flame Retardant ABS 1.16 (258) 6.54 (166) 8.11 (6) 9.25 (235) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
17 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CF-12V7 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 72A 43.2A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 11.5A 6.56A 3.5A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
18 CFR-12V1 Specifications CFR-12V1 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (5. amps to 1.75 volts)... 1 ampere hours 1 Hour Rate (9.6 amps to 1.75 volts) ampere hours 5 Hour Rate (16.5 amps to 1.75 volts) ampere hours 1 Hour Rate (61.8 amps to 1.6 volts) ampere hours 1/2 Hour Rate (15 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (33mm) Width inches (171mm) Height (excluding terminals) inches (2mm) Height (including terminals) inches (227mm) Weight lbs (32.kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 3. ampere maximum. Terminal: Standard is tin plated brass, bolt and nut Case Material: Flame Retardant ABS 13. (33) 6.73 (171) 8.66 (2) 8.94 (227) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
19 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V1 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 15A 61.8A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 16.5A 9.6A 5.A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
20 CFR-12V1 Specifications CFR-12V1 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (6. amps to 1.75 volts)... 1 ampere hours 1 Hour Rate (11.4 amps to 1.75 volts) ampere hours 5 Hour Rate (18.8 amps to 1.75 volts) ampere hours 1 Hour Rate (74.2 amps to 1.6 volts) ampere hours 1/2 Hour Rate (125 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (41mm) Width inches (175mm) Height (excluding terminals) inches (227mm) Height (including terminals) inches (227mm) Weight lbs (38.kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 36. ampere maximum. Terminal: Standard is tin plated brass, bolt and nut Case Material: Flame Retardant ABS (41) 6.89 (175) 8.94 (227) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
21 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V1 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 125A 74.2A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 18.8A 11.4A 6.A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
22 CFR-12V134 Specifications CFR-12V134 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (6.7 amps to 1.75 volts) ampere hours 1 Hour Rate (12.7 amps to 1.75 volts) ampere hours 5 Hour Rate (24.4 amps to 1.6 volts) ampere hours 1 Hour Rate (9.8 amps to 1.6 volts) ampere hours 1/2 Hour Rate (156 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (344mm) Width inches (171mm) Height (excluding terminals) inches (275mm) Height (including terminals) inches (278mm) Weight... 1 lbs (45kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range: Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 26.8 ampere maximum. Terminal: Standard is threaded insert, bolt and washer Case Material: Flame Retardant Polypropylene (344) 6.75 (171) 1.82 (275) 1.95 (278) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.
23 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V134 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosionor fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 156A 9.8A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 24.4A 12.7A 6.7A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C
Height w/o Terminals (in)
EaglePicher Technologies, LLC Commercial Power P.O. Box 47 Joplin, MO 6482 (417) 623-8 inquiry.carefree@eaglepicher.com Carefree Sealed Lead Acid (SLA) MSDS EaglePicher s Carefree lead acid batteries are
More informationCarefree Sealed Lead Acid (SLA) MSDS
EaglePicher Technologies, LLC Commercial Power P.O. Box 47 Joplin, MO 6482 (417) 623-8 inquiry.carefree@eaglepicher.com Carefree Sealed Lead Acid (SLA) MSDS EaglePicher s Carefree lead acid batteries are
More informationBattery Model: 25 Part Number: 8025-160 Nominal Voltage: 12 volts NSN: Number applied for, product currently available
Battery Model: 25 Part Number: 8025-160 Nominal Voltage: 12 volts NSN: Number applied for, product currently available Battery Model: 35 Part Number: 8020-164 Nominal Voltage: 12 volts NSN: Number applied
More informationTechnical Handbook Valve-Regulated Lead-Acid Batteries
Technical Handbook Valve-Regulated Lead-Acid Batteries Aerial view of the italian factory in Avezzano A ll FIAMM-GS batteries have been specifically developed to enhance economy of operation, reliability
More informationNP Series VALVE REGULATED LEAD-ACID BATTERIES
NP Series VALVE REGULATED LEAD-ACID BATTERIES NP RELIABILITY IS YOUR SECURITY Yuasa NP, NPC and NPH Batteries Utilising the latest advance design Oxygen Recombination Technology, Yuasa have applied their
More informationInstallation and Operating Instructions (for chargers shown below)
Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,
More informationDataSafe HX Top Terminated Batteries 6 and 12 Volt HX
DATASAFE HX TOP TERMINATED BATTERIES DataSafe HX Top Terminated Batteries 6 and 12 Volt HX Available exclusively from EnerSys, the world leader in stored power solutions. DataSafe HX Top Terminated Batteries.
More informationApproval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh
Approval Sheet for Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh AA Portable Power Corp (http://www.batteryspace.com) Address: 860 S, 19th St, Unit A, Richmond, CA, 94804 Tel: 510-525-2328
More informationWe ve Got The Power. Features
Engineered With Vision. Built With Care. Power-Sonic has more than 38 years of battery industry experience and today our batteries are sold in more than 7 countries world-wide. Since our inception in 197,
More informationLEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells
Engineering Production Sales LEAD CRYSTAL Valve-regulated lead-crystal batteries Energy storage Cells User Manual www.axcom-battery-technology.de info@.axcom-battery-technology.de Chapter 1: 1. Introduction
More informationInstallation and Operating Instructions (for chargers shown below)
Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,
More informationSolar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation
Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation BATTERY CHARGING GUIDELINES FOR GLOBAL/DAVIDSON TUBULAR PLATE BATTERIES Introduction Your Global/Davidson
More informationTel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks
Tel.X Ni-Cd battery The compact maintenance-free solution for telecom networks Tel.X, delivering high-energy performance in a compact maintenance-free package Tel.X: guaranteed power continuity for remote
More information1. Scope This specification is applied to ICR18650. 2. Product Specification Table 1 No. Item Rated Performance Remark
1. Scope This specification is applied to ICR18650. 2. Product Specification Table 1 No. Item Rated Performance Remark 1 Rated Capacity Typical Minimum 2 Nominal Voltage 3.7V 3 Voltage at end of Discharge
More informationIf you accidentally get battery acid on your skin, flush it with lots of water
RV Battery Savvy To properly maintain and extend the life of your RV batteries you need to have a basic understanding of what a battery is and how it works. Batteries used in RVs are lead acid batteries.
More informationTELEDYNE BATTERY PRODUCTS. INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL. For
TELEDYNE BATTERY PRODUCTS INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL For TSO-C173/C173a Authorized (GILL ) 7000 Series LT Valve-Regulated Lead-Acid Aircraft Batteries REFER
More informationBATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES
BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES Introduction Your 6-volt deep cycle battery set has been specially formulated for long cycle life and has particular voltage and specific gravity
More informationEVERGREEN (C.P.) USA INC. TEL: (650) 952-8091 FAX: (650) 952-3629 E-MAIL: sales@evergreencpusa.com. SPECIFICATIONS Lithium Battery CR123A- 1700mAh
Voltage (V) Voltage (V) Voltage (V) EVERGREEN (C.P.) USA INC. SPECIFICATIONS Lithium Battery CR123A- 1700mAh Temperature characteristics(20ma) (mah) Pulse discharge characteristics Model CR123A Nominal
More informationSELECTION GUIDE FIFTH EDITION
SELECTION GUIDE FIFTH EDITION GENESIS Selection Guide TABLE OF CONTENTS Company background EnerSys 2 Services and applications 3 Features and benefits 4 Technical information Capacity as a function of
More informationDear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.
Battery-Powered Mower NEUTON 24-Volt Charger Instructions Booklet Dear Neuton Owner, In order for you to get the most out of your Neuton Mower, we recently reviewed and revised our battery-charging instructions.
More informationEPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!
EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage
More informationLITHIUM BATTERY CR123A SPECIFICATION
LITHIUM BATTERY CR123A SPECIFICATION Date: April 24, 2012 Approved by: Scotty Scott PANASONIC ENERGY CORPORATION OF AMERICA LITHIUM BATTERY DIVISION 1. Designation : CR123A 2. Nominal Voltage : 3 V 3.
More information12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
More informationSpec. No. ICR18650-26C Version No. 0.0
1. Scope This product specification has been prepared to specify the rechargeable lithium-ion cell 2. Description and Model 2.1 Description Cell (lithium-ion rechargeable cell) 2.2 Model ICR18650-26C 3.
More informationTemperature Compensated Charging of Lead Acid Batteries
Technical Note Batteries 512-0101-01-01 Rev 1 Temperature Compensated Charging of Lead Acid Batteries Introduction To ensure optimum charging of lead acid batteries, the charge voltages should be adjusted
More informationLithium Iron Phosphate High Current Rechargeable Lithium Ion Batteries
1 of 5 8/21/2006 2:37 PM Lithium Iron Phosphate High Current Rechargeable Lithium Ion Batteries Lithium Iron phosphate batteries are safer than Lithium-ion cells, and are available in 10 and 20 AH packs
More informationBATTERY BASICS. This Automotive Series 12-volt Lead Acid BATTERY BASICS has been developed by. Kevin R. Sullivan
BATTERY BASICS This Automotive Series 12-volt Lead Acid BATTERY BASICS has been developed by Kevin R. Sullivan Professor of Automotive Technology Skyline College All Rights Reserved v1.1 Visit us on the
More information10 Year VRLA Battery Periodic Maintenance Instructions
TECHNICAL BULLETIN 41-7546 Valve Regulated Lead Acid Battery 20 to 200 ampere-hours capacity 10 Year VRLA Battery Periodic Maintenance Instructions 41-7546/0213/CD www.cdtechno.com General Information
More informationConstant Voltage Charger Selection for VRLA Batteries
TECHNICAL BULLETIN 41-2129 Constant Voltage Charger Selection for VRLA Batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products. While much
More informationBC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.
BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping
More information12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More informationCharger Output AC Ripple Voltage and the affect on VRLA batteries
TECHNICAL BULLETIN 41-2131 Charger Output AC Ripple Voltage and the affect on VRLA batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products.
More informationOWNER S MANUAL. Model AE150/AE300/AE500 1.5AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT
Model AE150/AE300/AE500 MULTI-USE SMART BATTERY CHARGER Certified by Californiia BCS Regulations AE300E AE500E 5AMP MULTI-USE AUTOMOTIVE BATTERY CHARGER 3AMP MULTI-USE SMART BATTERY CHARGER AE500E 5AMP
More informationAmps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps
Model Name Total Output Amps Per Bank Battery System Pro XL Dual Pro XL Pro SE Dual Pro SE Three Bank Pro SE Four Bank Pro SE Pro Charger Dual Pro Charger Three Bank Pro Charger 6 amps 12 amps 10 amps
More informationLi-ion Rechargeable Battery. Specification
Customer: Specification Model: GMB043450S Prepared By/Date Checked By/Date Approved By/Date Note:1.Kindly please sign on the above and send it back to us if the sample is approved. 2.Kindly please contact
More information400 Amp Rechargeable Jump Start System RAC-HP082
400 Amp Rechargeable Jump Start System RAC-HP082 MAINTENANCE Always inspect the tool before use to ensure the cables are in good condition and the clamps are clean and free from corrosion. Keep clean by
More informationTitle Li-ion Battery Specifications (Steel) Page 1/11
Title Li-ion Battery Specifications (Steel) Page 1/11 1. Scope This Specification is applied to rechargeable lithium ion battery cell of the following mentioned type for various applications in mobile
More informationTel.X Ni-Cd battery. The compact solution for stationary applications
Tel.X NiCd battery The compact solution for stationary applications Tel.X, delivering highenergy performance in a compact maintenancefree package Tel.X: guaranteed power continuity for remote or hard to
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
More informationCat Batteries. Cat Batteries Greater Starting Power Lower Maintenance Longer Life
Cat Batteries Greater Starting Power Lower Maintenance Longer Life Cat Premium High Output (PHO) batteries are used in all Caterpillar Machines and Engine Gen-Sets. They are designed to meet stringent
More informationCHARGING SYSTEMS INTERNATIONAL
CHARGING SYSTEMS INTERNATIONAL INSTALLATION AND OPERATING INSTRUCTIONS FOR THE FOLLOWING BATTERY CHARGING SYSTEMS: MODELS MAX AMPS/BANK NO. OF BANKS BATTERY SYSTEM PRO XL 6 1 12 DUAL PRO XL 6 2 12/24 PRO
More informationLS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
More information875 Dearborn Drive Columbus, Ohio 43085 Tel: (614) 846-7500 Fax: (614) 885-3990
Selection and Sizing of Batteries for UPS Backup 875 Dearborn Drive Columbus, Ohio 43085 Tel: (614) 846-7500 Fax: (614) 885-3990 Selection and Sizing of Batteries for UPS Backup Abstract Introduction Battery
More informationli-ion Polymer Battery Specification
Customer: li-ion Polymer Battery Specification MODEL: GMB042035 Prepared By/Date Checked By/Date Approved By/Date Note:1.Kindly please sign on the above and send it back to us if the sample is approved.
More informationFeatures of Power-Sonic Sealed Lead Acid Batteries...1. Battery Construction...2. Theory of Operation...3 & 4. Battery Capacity...
Table of Contents Features of Power-Sonic Sealed Lead Acid Batteries...1 Battery Construction...2 Theory of Operation...3 & 4 Battery Capacity...5 & 6 Battery Capacity Selector...7 Performance Data...8
More informationLi-ion Polymer Battery Specification
Customer: ME1421A Li-ion Polymer Battery Specification Model:HPL302030-130mAh Checked & Approved by Prepared by Date Andy Liu Wang Wei 2014-7-18 History of revisions Edition Prepared by Approved by Date
More informationBAO TONG USA dba TYSONIC BATTERY. SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH
BAO TONG USA dba TYSONIC BATTERY SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH I. GENERAL INTRODUCTION 1. Main Features 1) Friendly To The Environment Cd 0% Hg0% Pb0% 2) High Energy
More informationOWNER S MANUAL THE BATTERY THAT GOES TO EXTREMES
OWNER S MANUAL THE BATTERY THAT GOES TO EXTREMES INTRODUCTION The ODYSSEY battery ingeniously uses absorbed glass mat (AGM) technology to offer, in one box, the characteristics of two separate batteries.
More informationNorthStar Battery (NSB) Telecom Installation and Operation Guide
15DOC0020 NorthStar Battery (NSB) Telecom Installation and Operation Guide Contents 0 Definitions... 3 1 Battery Safety... 3 1.1 Old Batteries... 3 2 Handling... 4 2.1 Receiving the shipment... 4 2.2 Do...
More informationLIST OF CONTENTS STARTING DEVICES. Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck
LIST OF CONTENTS STARTING DEVICES Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck BULL STARTER 12 V The Banner booster for professionals!
More informationWolflite Safety Handlamp H-251E
Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63
More informationBATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW
WARNING CARTON INVENTORY CAUTION with: Charger, Cable 15', Fuses (2), Battery Strap and Strain Relief (2) Model SOLBBOX 12V Battery Not Included AVERTISSEMENT ATTENTION DC Power Adapter 12Vdc to 32Vdc
More informationBattery Backup Sump Pump System
Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical precautions 1 Battery preparation 1 Battery precautions 1 Introduction Items included in system
More informationUSER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
More informationMaintenance-free sealed lead accumulators. HAGEN drysafe
Maintenance-free sealed lead accumulators HAGEN drysafe HAGEN drysafe batteries are rechargeable and maintenance-free sealed lead accumulators with flat pasted grid-plates and bonded electrolyte in glass-fibre
More informationUniversal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
More informationBattery Backup Sump Pump System
Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical Precautions 1 Battery Preparation 1 Battery Precautions 1 Introduction
More informationPHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V
PHOTOVOLTAIC SYSTEM CONTROLLERS OPERATOR S MANUAL SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V 6A / 12V 10A / 12V 10A / 24V 20A / 12V 20A
More informationBattery Backup Sump Pump System
Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical Precautions 1 Battery Preparation 1 Battery Precautions 1 Introduction
More informationdin din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate
traction BATTERIES din 50Ah/plate [h1 = 282, h2 = 305 mm length = b = 198 mm] 2 EPzS 100 L 2 Pg 190 L 100 45 6,8 5,7 3 EPzS 150 L 3 Pg 190 L 150 63 9,6 7,7 4 EPzS 200 L 4 Pg 190 L 200 81 12,4 9,9 5 EPzS
More informationSOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
More informationOUTPUT CABLE CONNECTIONS:
Tender Plus: Models: 12V1.25A and 6V1.25A The Tender Plus 12 Volt, 1.25 Amp 6 Volt, 1.25 Amp GENERAL DESCRIPTION: The Tender Plus battery charger is a desktop, portable, linear power converter that has
More informationEffects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity
Effects of AC Ripple Current on VRLA Battery Life A Technical Note from the Experts in Business-Critical Continuity Introduction Given the importance of battery life to UPS system users and the fact that
More informationMANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.
MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
More informationSVB intern ZENITH AGM-Batterien
SVB intern ZENITH AGM-Batterien deep cycle heavy duty empfohlen für häufige Entladungen bis 80% Entladetiefe / siehe Seite 1 / see page 1 recommended for frequent discharges to 80% DOD Standard-Type geeignet
More informationBattery Management Innovation DIAGNOSTIC CONDUCTANCE CHARGER. For testing and charging 12-volt automotive batteries INSTRUCTION MANUAL
Battery Management Innovation DIAGNOSTIC CONDUCTANCE CHARGER For testing and charging 12-volt automotive batteries INSTRUCTION MANUAL Contents Safety instructions... 3 Installing the handle... 9 Operation...
More informationBattery Backup Sump Pump System
Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical Precautions 1 Battery Preparation 1 Battery Precautions 1 Introduction
More informationCHARGING METHODS. Methods of Charging the Valve Regulated (Sealed) Lead-Acid Battery. 19 Valve Regulated (Sealed) Lead-Acid Batteries
CHARGNG METHODS Methods of Charging the alve Regulated (Sealed) Lead-Acid Battery For charging the alve Regulated (Sealed) lead-acid battery, a well-matched charger should be used because the capacity
More informationTROJAN BATTERY USER S GUIDE
Congratulations on your purchase from Trojan Battery Company, the manufacturer of the world s most trusted deep cycle batteries. The battery you purchased was engineered by Trojan to deliver superior power,
More informationSpecification. Li-ion Rechargeable Battery
Specification of Li-ion Rechargeable Battery Model No.: 18650CA-1S-3J Reported by: 陈 声 宇 Date: Oct,17,2013 Checked by: Approved by: Date: Date: 1. Scope This specification describes the definition, technical
More informationHow To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationBeats Product Information Sheet 20 Watt Hours
Beats Product Information Sheet 20 Watt Hours The products referenced herein are articles and consumer products and therefore are excepted from the 29 CFR 1910.1200 Hazard Communication requirements. The
More information1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.
MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
More informationProTournament Series. Owner's Manual and Installation Guide. ProMariner. ProMariner. Professional Grade 3 Step Marine Battery Chargers WATERPROOF
ProMariner ProMariner Visit ProMariner Online at www.pmariner.com, for a Complete Selection of Quality Marine Products... Here are just a few: ProSport Series - Recreational Sport Fishing & Boating Waterproof
More informationTracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL
Tracer-1206RN / 1210RN / 1215RN Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions
More informationSpecification Approval Sheet
GUANGZHOU MARKYN BATTERY CO., LTD. Specification Approval Sheet FOR LIPO BATTERY Product Name Model SPEC Company Name Document Number Li-ion Polymer Battery 062025/250mAh/3.7V GMB POWER GMB1102150615 Sample
More informationXC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free 1 866 295 6775. www.powerbright.com
WARNING: This Unit employs Components that tend to produce arcs or sparks To prevent fire or explosion, do not install in compartments containing batteries or flammable materials - SHOCK HAZARD. DO NOT
More informationDELIVERY SPECIFICATIONS
DELIVERY SPECIFICATIONS Chemistry: Alkaline Manganese Dioxide Battery Model No.: HQ-ALK-AAA-01 Customer comment: Total pages: 5 (including this cover page) 1. Scope This specification governs the performance
More informationUptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications
NiCd battery Maintenancefree solution for backup power applications The ideal choice for total security and availability Saft your trusted battery partner for stationary applications Saft has over 100
More informationOceanscience Cable Chimp II Cableway ROV System User Guide and Warranty
Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty Page 1 Table of Contents Introduction Page 3 Overview Page 3 Setup and Operation Page 5 Remote Control Page 6 Power Management Page
More informationRG 7 SERIES AIRCRAFT BATTERY OWNER/OPERATOR MANUAL
RG 7 SERIES AIRCRAFT BATTERY OWNER/OPERATOR MANUAL CONCORDE BATTERY CORPORATION 2009 San Bernardino Road West Covina, CA 91790 Phone: 626-813-1234 www.concordebattery.com Document No. 5-0324 Revision C
More informationDigital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger
Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products
More informationSOLAR PV SYSTEM MAINTENANCE GUIDE
SOLAR PV SYSTEM MAINTENANCE GUIDE GUYANA HINTERLANDS STAND-ALONE SOLAR PV INSTALLATIONS IMPROVING HEALTH FACILITY INFRASTRUCTURE (IHFI) GUYANA CONTRACT NO. EPP-I-00-03-00008-00, TASK ORDER 07 APRIL 2013
More informationMaterial Safety Data Sheet
1. Product & Company Identification: Product: Conrad Energy Kamera-Akku Manufacturer: Conrad Electronic SE Nominal capacity: 1500 mah Nominal voltage: 7,4 V Address: Klaus-Conrad-Strasse 1, D-92240 Hirschau
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationINSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller
EPSOLAR Utility model patent NO. 201120064092.1 Tracer-2210RN / 2215RN Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL Thank you very much for selecting our product! This manual
More informationLi Battery Pack & Charger Safety & Operating Instructions
Li Battery Pack & Charger Safety & Operating Instructions NEUTON Power Equipment 75 Meigs Road Vergennes, VT 05491 Toll-Free phone: 1-866-NEUTON1 (638-8661) Fax: 1-802-877-1213 Website: www.neutonpower.com
More informationApple Product Information Sheet 20 Watt Hours
Apple Product Information Sheet 20 Watt Hours The products referenced herein are articles and consumer products and therefore are excepted from the 29 CFR 1910.1200 Hazard Communication requirements. The
More informationGuide rail bracket (for adjustable heads)
(for adjustable heads) Part. 209 40 ø,5 ø10,5 2 2,5 115 15 42 5 11 37 72 4 70 Code 209 / 0754 MATERIALS: Bracket made out of reinforced polyamide black colour. FEATURES: To be used with heads Part.221,
More informationBattery Handbook. By: RON SMITH
Battery Handbook By: RON SMITH Information compiled from the Battery Charger Handbook and the Battery Handbook written by Alvin G. Graham, Chief Engineer, Ratelco Electronics Inc. Introduction The purpose
More informationBATTERY CHARGER MULTI US 7000
US Switch Mode BATTERY CHARGER For lead-acid batteries 14-150 Ah MULTI US 7000 User s Manual and a guide to professional battery charging For Starter/Deep Cycle batteries INTRODUCTION The MULTI US 7000
More informationTELEDYNE BATTERY PRODUCTS
TELEDYNE BATTERY PRODUCTS LT Valve-Regulated Lead-Acid Batteries Part Numbers Applicable to This CMM 7639-27 7638-44 7641-20 7035-28 7243-16 7025-20 7243-14 7638-44T PROPOSITION 65 WARNING BATTERY POSTS,
More informationMANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel
MANUAL CONGRATULATIONS on the purchase of your new CTEK professional battery management unit. This unit is part of a range of professional battery chargers from CTEK SWEDEN AB. It represents the latest
More informationBATTERY CHARGER OWNER S MANUAL
SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for the automatic battery charger. Do not expose charger to rain or snow. Do not use and an attachment not recommended
More informationAUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E
AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E SENS part no: 101314 Document revision: F DCN No. 106811 Date 8/3/15 1840 Industrial Circle Longmont, CO 80501 Fax: (303) 678-7504
More informationNI-ZN BATTERY SPECIFICATION
NI-ZN BATTERY SPECIFICATION 252000 Model Name: AA2500mWh(Ni-Zn) Issued Date: Sept. 2010 NICKEL ZINC BATTERY SPECIFICATION 1.APPLICATION The applicable range: This specification is available only for the
More informationSubstation Battery & Charger Maintenance
Document title AUTHORIZED COPY Substation Battery & Charger Maintenance Document number MNT-TRMX-00015 Applies to: Keywords: Transmission Operations & Planning Department Carolinas and Florida maintenance;
More informationAlkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal
PRODUCT SAFETY PRECAUTIONS FOR HANDLING AND USE DURACELL alkaline manganese cells and batteries will provide long, reliable and safe service when used correctly. To achieve optimum performance and trouble-free
More information6 & 12 Volt Battery and Systems Tester with 100 Amp Load
6 & 12 Volt Battery and Systems Tester with 100 Amp Load Form No. 841-731 -000 DESCRIPTION This Load Tester tests 6 or 12 volt automotive-size lead-acid batteries under load. It will also test 6 or 12
More informationA reasonable, new furnace (mid efficiency) has the following electrical requirements:
June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,
More information