Height w/o Terminals (in)

Size: px
Start display at page:

Download "Height w/o Terminals (in)"

Transcription

1 EaglePicher Technologies, LLC Commercial Power P.O. Box 47 Joplin, MO 6482 (417) Carefree Sealed Lead Acid (SLA) MSDS EaglePicher s Carefree lead acid batteries are sealed and do not require maintenance during long periods of operation. If you do not find what you are looking for or would like more information, please contact us. Click on Part Number to view data sheet. Carefree Sealed Lead Acid (SLA) Batteries Nominal Voltage Nominal 77 F Length (in) Width (in) Height w/o Terminals (in) Height w/ Terminals (in) Weight (lb) Part Number CF-12V33/C CF-12V33/U CF-12V4FR CFR-12V CFR-12V CFR-12V CFR-12V CFR-12V CFR-12V CFR-12V134

2

3

4 CF-6V33 CF-12V33/C Specifications CF-6V33 Nominal Voltage... 6V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (1.65 amps to 1.75 volts) ampere hours 1 Hour Rate (3.1 amps to 1.75 volts) ampere hours 5 Hour Rate (5.4 amps to 1.6 volts) ampere hours 1 Hour Rate (19 amps to 1.6 volts) ampere hours 1/2 Hour Rate (35 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (159mm) Width inches (85mm) Height (excluding terminals) inches (165mm) Height (including terminals) inches (171mm) Weight lbs (5.5kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods Float Charging: Constant Potential Source of 6.8 to 6.9 volts continuously. Routine Charging: Constant Potential Source of 7.25 to 7.45 volts with a charging current of 1 ampere maximum. Terminal: Standard is tin plated brass, positive terminal is.3 stock x.25 wide, negative terminal is.3 stock by.25 wide, mates with Amp Faston series or equal. Case Material: ABS 6.25 (159) 3.35 (85) (171) (165) Specifications CF-12V33/C Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (1.65 amps to 1.75 volts) ampere hours 1 Hour Rate (3.1 amps to 1.75 volts) ampere hours 5 Hour Rate (5.4 amps to 1.6 volts) ampere hours 1 Hour Rate (19 amps to 1.6 volts) ampere hours 1/2 Hour Rate (35 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (171mm) Width inches (159mm) Height (excluding terminals) inches (165mm) Height (including terminals) inches (171mm) Weight lbs (54kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 1 ampere maximum. Terminal: Standard is tin plated brass, positive terminal is.3 stock x.25 wide, negative terminal is.3 stock by.25 wide, mates with Amp Faston series or equal. Case Material: ABS 6.72 (171) 6.25 (159) 6.5 (165) 6.75 (171) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

5 2.7 Charge Voltage per Cell vs. Temperature CF-6V33 CF-12V33/C Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Deep Cyclic Charging Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) Typical Voltage Characteristic (7 F) DISCHARGE CURVE A 3.1A 1.65A A 3.1A 1.65A A 9. 19A A 35A 1 6 Volt Volt min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

6 CF-12V33/U1 Specifications CF-12V33/U1 Nominal Voltage V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (1.65 amps to 1.75 volts) ampere hours 1 Hour Rate (3.15 amps to 1.75 volts) ampere hours 5 Hour Rate (5.5 amps to 1.75 volts) ampere hours 1 Hour Rate (.6 amps to 1.6 volts)....6 ampere hours 1/2 Hour Rate (33.4 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (195mm) Width inches (13mm) Height (excluding terminals) inches (159mm) Height (including terminals) inches (18mm) Weight lbs (1.2kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 9.9 ampere maximum. Terminal: Standard is lead post, bolt and nut Case Material: ABS 7.68 (195) 5.12 (13) (18) (159) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

7 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CF-12V33/U1 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 33.4A.6A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 5.5A 3.15A 1.65A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

8 - + CF-12V4FR Specifications CF-12V4FR Nominal Open Circuit Voltage V Nominal Working Voltage V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (1.85 amps to 1.75 volts) ampere hours 1 Hour Rate (3.4 amps to 1.75 volts) ampere hours 5 Hour Rate (6. amps to 1.75 volts) ampere hours 1 Hour Rate (21. amps to 1.6 volts) ampere hours 1/2 Hour Rate (31. amps to 1.6 volts) ampere hours Max. Physical Size: Length inches (254mm) Width inches (97mm) Height (excluding terminals) inches (3mm) Height (including terminals) inches (3mm) Weight lbs (15.kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +16 F (-51 C to +71 C) Charge... F to +122 F (-18 C to +5 C) Recharging Methods: Float Charging: Constant Potential Source of to volts continuously. Routine Charging: Constant Potential Source of 14.7 to 15. volts with a charging current of 13.5 ampere maximum. Hardware Package: Two 1-32 x 1/2" Lg. 1mm Hex Head Bolts; Two No. 1 Flat Washers, and Two No. 1 Split Ring Lock Washers - all are Stainless Steel. Terminal: Lead plated copper insert threaded for 1-32 bolt. Flame Arrestor - Polypropylene 1. cu ft/min (27l/min) Case Material: Polycarbonate Flame Class: UL94 V-O Limited Oxygen Index: 35% Float Life Expectancy: 8+ years at 77 F (25 C) 1% Capacity Screened and Matched Two Year Full Warranty at average battery temperature of 77 F (25 C) or less 1. (254) 8. (3) 3.8 (97) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

9 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CF-12V4FR Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 31.A 21.A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 6.A 3.4A1.85A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

10 CFR-12V38 Specifications CFR-12V38 Nominal Voltage...12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (2. amps to 1.5 volts) ampere hours 1 Hour Rate (3.72 amps to 1.5 volts) ampere hours 5 Hour Rate (6.8 amps to 1.2 volts) ampere hours 1 Hour Rate (23.2 amps to 1.2 volts) ampere hours 1/2 Hour Rate (42. amps to 1.2 volts) ampere hours Max. Physical Size: Length inches (197mm) Width inches (165mm) Height (excluding terminals) inches (17mm) Height (including terminals) inches (17mm) Weight lbs (13.6kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.5 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 15. volts with a charging current of 16. ampere maximum. Terminal: Standard is bolt and nut (M5) Case Material: Flame Retardant ABS 7.76 (197) 6.5 (165) 6.69 (17) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

11 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V38 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 42A 23.2A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 6.8A 3.72A 2.A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

12 CFR-12V55 Specifications CFR-12V55 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (2.75 amps to 1.75 volts) ampere hours 1 Hour Rate (5.3 amps to 1.75 volts) ampere hours 5 Hour Rate (9.1 amps to 1.6 volts) ampere hours 1 Hour Rate (34 amps to 1.6 volts) ampere hours 1/2 Hour Rate (58 amps to 1.6 volts) ampere hours Max. Physical Size: Length inches (236mm) Width inches (132mm) Height (excluding terminals) inches (5mm) Height (including terminals) inches (235mm) Weight lbs (18kg) Energy Density ( Hour Rate): watt hrs/cu in ( Hour Rate): watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.5 to 14.9 volts with a charging current of 18. ampere maximum. Terminal: Standard is lead post, bolt and nut Case Material: Flame Retardant ABS 8.74 (222) 9.29 (236) 5.2 (132) 8.7 (5) 9.25 (235) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

13 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V55 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 58A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 34A 9.1A 5.3A 2.75A 4 o F 4 o C

14 CFR-12V65 Specifications CFR-12V65 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (3.25 amps to 1.75 volts) ampere hours 1 Hour Rate (6.2 amps to 1.75 volts) ampere hours 5 Hour Rate (1.6 amps to 1.75 volts) ampere hours 1 Hour Rate (4.2 amps to 1.6 volts) ampere hours 1/2 Hour Rate (68 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (355mm) Width inches (167mm) Height (excluding terminals) inches (179mm) Height (including terminals) inches (183mm) Weight lbs (22.2kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 19.5 ampere maximum. Terminal: Standard is tin plated brass, bolt and nut Case Material: Flame Retardant ABS (355) 6.57 (167) (183) (179) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

15 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V65 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 68A 4.2A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 1.6A 6.2A 3.25A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

16 CFR-12V7 Specifications CFR-12V7 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (3.5 amps to 1.75 volts)... 7 ampere hours 1 Hour Rate (6.56 amps to 1.75 volts) ampere hours 5 Hour Rate (11.5 amps to 1.75 volts) ampere hours 1 Hour Rate (43.2 amps to 1.6 volts) ampere hours 1/2 Hour Rate (72 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (258mm) Width inches (166mm) Height (excluding terminals) inches (6mm) Height (including terminals) inches (235mm) Weight lbs (24.kg) Energy Density ( Hour Rate): watt hrs/cu in ( Hour Rate): watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 18. ampere maximum. Terminal: Standard is lead post, bolt and nut Case Material: Flame Retardant ABS 1.16 (258) 6.54 (166) 8.11 (6) 9.25 (235) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

17 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CF-12V7 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 72A 43.2A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 11.5A 6.56A 3.5A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

18 CFR-12V1 Specifications CFR-12V1 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (5. amps to 1.75 volts)... 1 ampere hours 1 Hour Rate (9.6 amps to 1.75 volts) ampere hours 5 Hour Rate (16.5 amps to 1.75 volts) ampere hours 1 Hour Rate (61.8 amps to 1.6 volts) ampere hours 1/2 Hour Rate (15 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (33mm) Width inches (171mm) Height (excluding terminals) inches (2mm) Height (including terminals) inches (227mm) Weight lbs (32.kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 3. ampere maximum. Terminal: Standard is tin plated brass, bolt and nut Case Material: Flame Retardant ABS 13. (33) 6.73 (171) 8.66 (2) 8.94 (227) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

19 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V1 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 15A 61.8A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 16.5A 9.6A 5.A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

20 CFR-12V1 Specifications CFR-12V1 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (6. amps to 1.75 volts)... 1 ampere hours 1 Hour Rate (11.4 amps to 1.75 volts) ampere hours 5 Hour Rate (18.8 amps to 1.75 volts) ampere hours 1 Hour Rate (74.2 amps to 1.6 volts) ampere hours 1/2 Hour Rate (125 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (41mm) Width inches (175mm) Height (excluding terminals) inches (227mm) Height (including terminals) inches (227mm) Weight lbs (38.kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 36. ampere maximum. Terminal: Standard is tin plated brass, bolt and nut Case Material: Flame Retardant ABS (41) 6.89 (175) 8.94 (227) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

21 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V1 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosion or fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 125A 74.2A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 18.8A 11.4A 6.A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

22 CFR-12V134 Specifications CFR-12V134 Nominal Voltage... 12V Nominal Capacity at 77 F (25 C) Voltage readings are per cell Hour Rate (6.7 amps to 1.75 volts) ampere hours 1 Hour Rate (12.7 amps to 1.75 volts) ampere hours 5 Hour Rate (24.4 amps to 1.6 volts) ampere hours 1 Hour Rate (9.8 amps to 1.6 volts) ampere hours 1/2 Hour Rate (156 amps to 1.6 volts) ampere hours Max. Physical Size Length inches (344mm) Width inches (171mm) Height (excluding terminals) inches (275mm) Height (including terminals) inches (278mm) Weight... 1 lbs (45kg) Energy Density ( Hour Rate) watt hrs/cu in ( Hour Rate) watt hrs/lbs Operating Temperature Range: Discharge F to +14 F (-51 C to +6 C) Charge... F to +1 F (-18 C to +49 C) Recharging Methods: Float Charging: Constant Potential Source of 13.6 to 13.8 volts continuously. Routine Charging: Constant Potential Source of 14.4 to 14.7 volts with a charging current of 26.8 ampere maximum. Terminal: Standard is threaded insert, bolt and washer Case Material: Flame Retardant Polypropylene (344) 6.75 (171) 1.82 (275) 1.95 (278) Above data are average values which can be obtained within 3 charge/discharge cycles. These are not minimum values.

23 2.7 Charge Voltage per Cell vs. Temperature 2.6 Deep Cyclic Charging CFR-12V134 Charging vs Temperature The charging of Carefree batteries is best accomplished in a temperature range of 6 F to 9 F. Charging within this temperature range requires no temperature compensation. For applications over a wider temperature range, charging voltage must be changed as a function of temperature. (see chart at right) Capacity vs Temperature The efficiency of the lead-acid system decreases as the temperature decreases and increases as temperature increases from room temperature (7 ) as illustrated. These four curves shown are based on discharges at the hour, 5 hour, 11/2 hour and 1 hour rates. Self-Discharge Characteristics High temperature increases the rate of self-discharge of all battery systems but even in this respect, the lead-calcium battery is perhaps least affected. In general, the rate of self-discharge can be expected to double for each F rise in temperature above 7 F. Battery Operating Conditions & Cautions Battery contains toxic material (lead) and corrosive fluid (sulfuric acid) Charging can produce explosive gases Do not charge in gas tight enclosures Charge battery in a well-ventilated area away from sparks, flames or smoking Use approved voltage controlled charger Do not short-circuit battery terminals, as this can cause an explosionor fire Keep batteries and chargers away from children Charge battery as soon as possible after use Do not store battery in discharged state Do not puncture, disassemble, mutilate or incinerate MUST BE RECYCLED OR DISPOSED OF PROPERLY Installation Care All CAREFREE batteries are carefully assembled and with proper charging will provide excellent service. When placing the battery into service it must be inspected to make sure that the battery has not been damaged by rough handling. If the unit has been damaged, there is a possibility of a loss of a small amount of sulfuric acid electrolyte and possible corrosion of adjacent components. Any sulfuric acid can cause severe burns to the skin and eyes. If contact is made with a damaged battery, immediately wash the contacted area with water for at least 5 minutes. When installing the battery in equipment, ventilation must be provided. Toward the end of charge and under overcharge conditions, hydrogen and oxygen gas can be generated. If this gas is allowed to accumulate in the enclosure and a spark is introduced, an explosion could result. The specifications on this sheet may be changed by Eagle-Picher Technologies, LLC, without notice. P.O. BOX 47 JOPLIN, MO 6482 (417) FAX (417) inquiry.carefree@eaglepicher.com Web Site: BATTERY VOLTAGE (V) (AMPERE HOURS) VOLTS PER CELL PERCENTAGE OF NOMINAL CAPACITY PERCENTAGE OF FULL CAPACITY Shallow Cyclic Charging Float Charging VARIOUS RATES OF DISCHARGE AMBIENT TEMPERATURE o F 38 o C hr /2 hr. 5 hr. 1 hr TEMPERATURE 8 o F 27 o C Capacity as Affected by Temperature 1 49 Typical Voltage Characteristic (7 F) DISCHARGE CURVE 156A 9.8A o F 16 o C STORAGE TIME - MONTHS 5 ( o C) 122 ( o F) ( o F) ( o C) 24.4A 12.7A 6.7A min. hrs. DISCHARGE TIME Typical Self-Discharge Characteristics 4 o F 4 o C

Height w/o Terminals (in)

Height w/o Terminals (in) EaglePicher Technologies, LLC Commercial Power P.O. Box 47 Joplin, MO 6482 (417) 623-8 inquiry.carefree@eaglepicher.com Carefree Sealed Lead Acid (SLA) MSDS EaglePicher s Carefree lead acid batteries are

More information

Carefree Sealed Lead Acid (SLA) MSDS

Carefree Sealed Lead Acid (SLA) MSDS EaglePicher Technologies, LLC Commercial Power P.O. Box 47 Joplin, MO 6482 (417) 623-8 inquiry.carefree@eaglepicher.com Carefree Sealed Lead Acid (SLA) MSDS EaglePicher s Carefree lead acid batteries are

More information

Battery Model: 25 Part Number: 8025-160 Nominal Voltage: 12 volts NSN: Number applied for, product currently available

Battery Model: 25 Part Number: 8025-160 Nominal Voltage: 12 volts NSN: Number applied for, product currently available Battery Model: 25 Part Number: 8025-160 Nominal Voltage: 12 volts NSN: Number applied for, product currently available Battery Model: 35 Part Number: 8020-164 Nominal Voltage: 12 volts NSN: Number applied

More information

Technical Handbook Valve-Regulated Lead-Acid Batteries

Technical Handbook Valve-Regulated Lead-Acid Batteries Technical Handbook Valve-Regulated Lead-Acid Batteries Aerial view of the italian factory in Avezzano A ll FIAMM-GS batteries have been specifically developed to enhance economy of operation, reliability

More information

NP Series VALVE REGULATED LEAD-ACID BATTERIES

NP Series VALVE REGULATED LEAD-ACID BATTERIES NP Series VALVE REGULATED LEAD-ACID BATTERIES NP RELIABILITY IS YOUR SECURITY Yuasa NP, NPC and NPH Batteries Utilising the latest advance design Oxygen Recombination Technology, Yuasa have applied their

More information

Installation and Operating Instructions (for chargers shown below)

Installation and Operating Instructions (for chargers shown below) Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,

More information

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX DATASAFE HX TOP TERMINATED BATTERIES DataSafe HX Top Terminated Batteries 6 and 12 Volt HX Available exclusively from EnerSys, the world leader in stored power solutions. DataSafe HX Top Terminated Batteries.

More information

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh Approval Sheet for Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh AA Portable Power Corp (http://www.batteryspace.com) Address: 860 S, 19th St, Unit A, Richmond, CA, 94804 Tel: 510-525-2328

More information

We ve Got The Power. Features

We ve Got The Power. Features Engineered With Vision. Built With Care. Power-Sonic has more than 38 years of battery industry experience and today our batteries are sold in more than 7 countries world-wide. Since our inception in 197,

More information

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells Engineering Production Sales LEAD CRYSTAL Valve-regulated lead-crystal batteries Energy storage Cells User Manual www.axcom-battery-technology.de info@.axcom-battery-technology.de Chapter 1: 1. Introduction

More information

Installation and Operating Instructions (for chargers shown below)

Installation and Operating Instructions (for chargers shown below) Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,

More information

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation BATTERY CHARGING GUIDELINES FOR GLOBAL/DAVIDSON TUBULAR PLATE BATTERIES Introduction Your Global/Davidson

More information

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks Tel.X Ni-Cd battery The compact maintenance-free solution for telecom networks Tel.X, delivering high-energy performance in a compact maintenance-free package Tel.X: guaranteed power continuity for remote

More information

1. Scope This specification is applied to ICR18650. 2. Product Specification Table 1 No. Item Rated Performance Remark

1. Scope This specification is applied to ICR18650. 2. Product Specification Table 1 No. Item Rated Performance Remark 1. Scope This specification is applied to ICR18650. 2. Product Specification Table 1 No. Item Rated Performance Remark 1 Rated Capacity Typical Minimum 2 Nominal Voltage 3.7V 3 Voltage at end of Discharge

More information

If you accidentally get battery acid on your skin, flush it with lots of water

If you accidentally get battery acid on your skin, flush it with lots of water RV Battery Savvy To properly maintain and extend the life of your RV batteries you need to have a basic understanding of what a battery is and how it works. Batteries used in RVs are lead acid batteries.

More information

TELEDYNE BATTERY PRODUCTS. INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL. For

TELEDYNE BATTERY PRODUCTS. INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL. For TELEDYNE BATTERY PRODUCTS INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL For TSO-C173/C173a Authorized (GILL ) 7000 Series LT Valve-Regulated Lead-Acid Aircraft Batteries REFER

More information

BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES

BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES Introduction Your 6-volt deep cycle battery set has been specially formulated for long cycle life and has particular voltage and specific gravity

More information

EVERGREEN (C.P.) USA INC. TEL: (650) 952-8091 FAX: (650) 952-3629 E-MAIL: sales@evergreencpusa.com. SPECIFICATIONS Lithium Battery CR123A- 1700mAh

EVERGREEN (C.P.) USA INC. TEL: (650) 952-8091 FAX: (650) 952-3629 E-MAIL: sales@evergreencpusa.com. SPECIFICATIONS Lithium Battery CR123A- 1700mAh Voltage (V) Voltage (V) Voltage (V) EVERGREEN (C.P.) USA INC. SPECIFICATIONS Lithium Battery CR123A- 1700mAh Temperature characteristics(20ma) (mah) Pulse discharge characteristics Model CR123A Nominal

More information

SELECTION GUIDE FIFTH EDITION

SELECTION GUIDE FIFTH EDITION SELECTION GUIDE FIFTH EDITION GENESIS Selection Guide TABLE OF CONTENTS Company background EnerSys 2 Services and applications 3 Features and benefits 4 Technical information Capacity as a function of

More information

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger. Battery-Powered Mower NEUTON 24-Volt Charger Instructions Booklet Dear Neuton Owner, In order for you to get the most out of your Neuton Mower, we recently reviewed and revised our battery-charging instructions.

More information

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product! EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage

More information

LITHIUM BATTERY CR123A SPECIFICATION

LITHIUM BATTERY CR123A SPECIFICATION LITHIUM BATTERY CR123A SPECIFICATION Date: April 24, 2012 Approved by: Scotty Scott PANASONIC ENERGY CORPORATION OF AMERICA LITHIUM BATTERY DIVISION 1. Designation : CR123A 2. Nominal Voltage : 3 V 3.

More information

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual 12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar

More information

Spec. No. ICR18650-26C Version No. 0.0

Spec. No. ICR18650-26C Version No. 0.0 1. Scope This product specification has been prepared to specify the rechargeable lithium-ion cell 2. Description and Model 2.1 Description Cell (lithium-ion rechargeable cell) 2.2 Model ICR18650-26C 3.

More information

Temperature Compensated Charging of Lead Acid Batteries

Temperature Compensated Charging of Lead Acid Batteries Technical Note Batteries 512-0101-01-01 Rev 1 Temperature Compensated Charging of Lead Acid Batteries Introduction To ensure optimum charging of lead acid batteries, the charge voltages should be adjusted

More information

Lithium Iron Phosphate High Current Rechargeable Lithium Ion Batteries

Lithium Iron Phosphate High Current Rechargeable Lithium Ion Batteries 1 of 5 8/21/2006 2:37 PM Lithium Iron Phosphate High Current Rechargeable Lithium Ion Batteries Lithium Iron phosphate batteries are safer than Lithium-ion cells, and are available in 10 and 20 AH packs

More information

BATTERY BASICS. This Automotive Series 12-volt Lead Acid BATTERY BASICS has been developed by. Kevin R. Sullivan

BATTERY BASICS. This Automotive Series 12-volt Lead Acid BATTERY BASICS has been developed by. Kevin R. Sullivan BATTERY BASICS This Automotive Series 12-volt Lead Acid BATTERY BASICS has been developed by Kevin R. Sullivan Professor of Automotive Technology Skyline College All Rights Reserved v1.1 Visit us on the

More information

10 Year VRLA Battery Periodic Maintenance Instructions

10 Year VRLA Battery Periodic Maintenance Instructions TECHNICAL BULLETIN 41-7546 Valve Regulated Lead Acid Battery 20 to 200 ampere-hours capacity 10 Year VRLA Battery Periodic Maintenance Instructions 41-7546/0213/CD www.cdtechno.com General Information

More information

Constant Voltage Charger Selection for VRLA Batteries

Constant Voltage Charger Selection for VRLA Batteries TECHNICAL BULLETIN 41-2129 Constant Voltage Charger Selection for VRLA Batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products. While much

More information

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC. BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Charger Output AC Ripple Voltage and the affect on VRLA batteries

Charger Output AC Ripple Voltage and the affect on VRLA batteries TECHNICAL BULLETIN 41-2131 Charger Output AC Ripple Voltage and the affect on VRLA batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products.

More information

OWNER S MANUAL. Model AE150/AE300/AE500 1.5AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

OWNER S MANUAL. Model AE150/AE300/AE500 1.5AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT Model AE150/AE300/AE500 MULTI-USE SMART BATTERY CHARGER Certified by Californiia BCS Regulations AE300E AE500E 5AMP MULTI-USE AUTOMOTIVE BATTERY CHARGER 3AMP MULTI-USE SMART BATTERY CHARGER AE500E 5AMP

More information

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps Model Name Total Output Amps Per Bank Battery System Pro XL Dual Pro XL Pro SE Dual Pro SE Three Bank Pro SE Four Bank Pro SE Pro Charger Dual Pro Charger Three Bank Pro Charger 6 amps 12 amps 10 amps

More information

Li-ion Rechargeable Battery. Specification

Li-ion Rechargeable Battery. Specification Customer: Specification Model: GMB043450S Prepared By/Date Checked By/Date Approved By/Date Note:1.Kindly please sign on the above and send it back to us if the sample is approved. 2.Kindly please contact

More information

400 Amp Rechargeable Jump Start System RAC-HP082

400 Amp Rechargeable Jump Start System RAC-HP082 400 Amp Rechargeable Jump Start System RAC-HP082 MAINTENANCE Always inspect the tool before use to ensure the cables are in good condition and the clamps are clean and free from corrosion. Keep clean by

More information

Title Li-ion Battery Specifications (Steel) Page 1/11

Title Li-ion Battery Specifications (Steel) Page 1/11 Title Li-ion Battery Specifications (Steel) Page 1/11 1. Scope This Specification is applied to rechargeable lithium ion battery cell of the following mentioned type for various applications in mobile

More information

Tel.X Ni-Cd battery. The compact solution for stationary applications

Tel.X Ni-Cd battery. The compact solution for stationary applications Tel.X NiCd battery The compact solution for stationary applications Tel.X, delivering highenergy performance in a compact maintenancefree package Tel.X: guaranteed power continuity for remote or hard to

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

Cat Batteries. Cat Batteries Greater Starting Power Lower Maintenance Longer Life

Cat Batteries. Cat Batteries Greater Starting Power Lower Maintenance Longer Life Cat Batteries Greater Starting Power Lower Maintenance Longer Life Cat Premium High Output (PHO) batteries are used in all Caterpillar Machines and Engine Gen-Sets. They are designed to meet stringent

More information

CHARGING SYSTEMS INTERNATIONAL

CHARGING SYSTEMS INTERNATIONAL CHARGING SYSTEMS INTERNATIONAL INSTALLATION AND OPERATING INSTRUCTIONS FOR THE FOLLOWING BATTERY CHARGING SYSTEMS: MODELS MAX AMPS/BANK NO. OF BANKS BATTERY SYSTEM PRO XL 6 1 12 DUAL PRO XL 6 2 12/24 PRO

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

875 Dearborn Drive Columbus, Ohio 43085 Tel: (614) 846-7500 Fax: (614) 885-3990

875 Dearborn Drive Columbus, Ohio 43085 Tel: (614) 846-7500 Fax: (614) 885-3990 Selection and Sizing of Batteries for UPS Backup 875 Dearborn Drive Columbus, Ohio 43085 Tel: (614) 846-7500 Fax: (614) 885-3990 Selection and Sizing of Batteries for UPS Backup Abstract Introduction Battery

More information

li-ion Polymer Battery Specification

li-ion Polymer Battery Specification Customer: li-ion Polymer Battery Specification MODEL: GMB042035 Prepared By/Date Checked By/Date Approved By/Date Note:1.Kindly please sign on the above and send it back to us if the sample is approved.

More information

Features of Power-Sonic Sealed Lead Acid Batteries...1. Battery Construction...2. Theory of Operation...3 & 4. Battery Capacity...

Features of Power-Sonic Sealed Lead Acid Batteries...1. Battery Construction...2. Theory of Operation...3 & 4. Battery Capacity... Table of Contents Features of Power-Sonic Sealed Lead Acid Batteries...1 Battery Construction...2 Theory of Operation...3 & 4 Battery Capacity...5 & 6 Battery Capacity Selector...7 Performance Data...8

More information

Li-ion Polymer Battery Specification

Li-ion Polymer Battery Specification Customer: ME1421A Li-ion Polymer Battery Specification Model:HPL302030-130mAh Checked & Approved by Prepared by Date Andy Liu Wang Wei 2014-7-18 History of revisions Edition Prepared by Approved by Date

More information

BAO TONG USA dba TYSONIC BATTERY. SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH

BAO TONG USA dba TYSONIC BATTERY. SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH BAO TONG USA dba TYSONIC BATTERY SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH I. GENERAL INTRODUCTION 1. Main Features 1) Friendly To The Environment Cd 0% Hg0% Pb0% 2) High Energy

More information

OWNER S MANUAL THE BATTERY THAT GOES TO EXTREMES

OWNER S MANUAL THE BATTERY THAT GOES TO EXTREMES OWNER S MANUAL THE BATTERY THAT GOES TO EXTREMES INTRODUCTION The ODYSSEY battery ingeniously uses absorbed glass mat (AGM) technology to offer, in one box, the characteristics of two separate batteries.

More information

NorthStar Battery (NSB) Telecom Installation and Operation Guide

NorthStar Battery (NSB) Telecom Installation and Operation Guide 15DOC0020 NorthStar Battery (NSB) Telecom Installation and Operation Guide Contents 0 Definitions... 3 1 Battery Safety... 3 1.1 Old Batteries... 3 2 Handling... 4 2.1 Receiving the shipment... 4 2.2 Do...

More information

LIST OF CONTENTS STARTING DEVICES. Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck

LIST OF CONTENTS STARTING DEVICES. Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck LIST OF CONTENTS STARTING DEVICES Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck BULL STARTER 12 V The Banner booster for professionals!

More information

Wolflite Safety Handlamp H-251E

Wolflite Safety Handlamp H-251E Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63

More information

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW WARNING CARTON INVENTORY CAUTION with: Charger, Cable 15', Fuses (2), Battery Strap and Strain Relief (2) Model SOLBBOX 12V Battery Not Included AVERTISSEMENT ATTENTION DC Power Adapter 12Vdc to 32Vdc

More information

Battery Backup Sump Pump System

Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical precautions 1 Battery preparation 1 Battery precautions 1 Introduction Items included in system

More information

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018 USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and

More information

Maintenance-free sealed lead accumulators. HAGEN drysafe

Maintenance-free sealed lead accumulators. HAGEN drysafe Maintenance-free sealed lead accumulators HAGEN drysafe HAGEN drysafe batteries are rechargeable and maintenance-free sealed lead accumulators with flat pasted grid-plates and bonded electrolyte in glass-fibre

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

Battery Backup Sump Pump System

Battery Backup Sump Pump System Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical Precautions 1 Battery Preparation 1 Battery Precautions 1 Introduction

More information

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V PHOTOVOLTAIC SYSTEM CONTROLLERS OPERATOR S MANUAL SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V 6A / 12V 10A / 12V 10A / 24V 20A / 12V 20A

More information

Battery Backup Sump Pump System

Battery Backup Sump Pump System Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical Precautions 1 Battery Preparation 1 Battery Precautions 1 Introduction

More information

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate traction BATTERIES din 50Ah/plate [h1 = 282, h2 = 305 mm length = b = 198 mm] 2 EPzS 100 L 2 Pg 190 L 100 45 6,8 5,7 3 EPzS 150 L 3 Pg 190 L 150 63 9,6 7,7 4 EPzS 200 L 4 Pg 190 L 200 81 12,4 9,9 5 EPzS

More information

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity

More information

OUTPUT CABLE CONNECTIONS:

OUTPUT CABLE CONNECTIONS: Tender Plus: Models: 12V1.25A and 6V1.25A The Tender Plus 12 Volt, 1.25 Amp 6 Volt, 1.25 Amp GENERAL DESCRIPTION: The Tender Plus battery charger is a desktop, portable, linear power converter that has

More information

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity Effects of AC Ripple Current on VRLA Battery Life A Technical Note from the Experts in Business-Critical Continuity Introduction Given the importance of battery life to UPS system users and the fact that

More information

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options. MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest

More information

SVB intern ZENITH AGM-Batterien

SVB intern ZENITH AGM-Batterien SVB intern ZENITH AGM-Batterien deep cycle heavy duty empfohlen für häufige Entladungen bis 80% Entladetiefe / siehe Seite 1 / see page 1 recommended for frequent discharges to 80% DOD Standard-Type geeignet

More information

Battery Management Innovation DIAGNOSTIC CONDUCTANCE CHARGER. For testing and charging 12-volt automotive batteries INSTRUCTION MANUAL

Battery Management Innovation DIAGNOSTIC CONDUCTANCE CHARGER. For testing and charging 12-volt automotive batteries INSTRUCTION MANUAL Battery Management Innovation DIAGNOSTIC CONDUCTANCE CHARGER For testing and charging 12-volt automotive batteries INSTRUCTION MANUAL Contents Safety instructions... 3 Installing the handle... 9 Operation...

More information

Battery Backup Sump Pump System

Battery Backup Sump Pump System Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical Precautions 1 Battery Preparation 1 Battery Precautions 1 Introduction

More information

CHARGING METHODS. Methods of Charging the Valve Regulated (Sealed) Lead-Acid Battery. 19 Valve Regulated (Sealed) Lead-Acid Batteries

CHARGING METHODS. Methods of Charging the Valve Regulated (Sealed) Lead-Acid Battery. 19 Valve Regulated (Sealed) Lead-Acid Batteries CHARGNG METHODS Methods of Charging the alve Regulated (Sealed) Lead-Acid Battery For charging the alve Regulated (Sealed) lead-acid battery, a well-matched charger should be used because the capacity

More information

TROJAN BATTERY USER S GUIDE

TROJAN BATTERY USER S GUIDE Congratulations on your purchase from Trojan Battery Company, the manufacturer of the world s most trusted deep cycle batteries. The battery you purchased was engineered by Trojan to deliver superior power,

More information

Specification. Li-ion Rechargeable Battery

Specification. Li-ion Rechargeable Battery Specification of Li-ion Rechargeable Battery Model No.: 18650CA-1S-3J Reported by: 陈 声 宇 Date: Oct,17,2013 Checked by: Approved by: Date: Date: 1. Scope This specification describes the definition, technical

More information

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply Unit (Upu) BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

Beats Product Information Sheet 20 Watt Hours

Beats Product Information Sheet 20 Watt Hours Beats Product Information Sheet 20 Watt Hours The products referenced herein are articles and consumer products and therefore are excepted from the 29 CFR 1910.1200 Hazard Communication requirements. The

More information

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program. MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest

More information

ProTournament Series. Owner's Manual and Installation Guide. ProMariner. ProMariner. Professional Grade 3 Step Marine Battery Chargers WATERPROOF

ProTournament Series. Owner's Manual and Installation Guide. ProMariner. ProMariner. Professional Grade 3 Step Marine Battery Chargers WATERPROOF ProMariner ProMariner Visit ProMariner Online at www.pmariner.com, for a Complete Selection of Quality Marine Products... Here are just a few: ProSport Series - Recreational Sport Fishing & Boating Waterproof

More information

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL Tracer-1206RN / 1210RN / 1215RN Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions

More information

Specification Approval Sheet

Specification Approval Sheet GUANGZHOU MARKYN BATTERY CO., LTD. Specification Approval Sheet FOR LIPO BATTERY Product Name Model SPEC Company Name Document Number Li-ion Polymer Battery 062025/250mAh/3.7V GMB POWER GMB1102150615 Sample

More information

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free 1 866 295 6775. www.powerbright.com

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free 1 866 295 6775. www.powerbright.com WARNING: This Unit employs Components that tend to produce arcs or sparks To prevent fire or explosion, do not install in compartments containing batteries or flammable materials - SHOCK HAZARD. DO NOT

More information

DELIVERY SPECIFICATIONS

DELIVERY SPECIFICATIONS DELIVERY SPECIFICATIONS Chemistry: Alkaline Manganese Dioxide Battery Model No.: HQ-ALK-AAA-01 Customer comment: Total pages: 5 (including this cover page) 1. Scope This specification governs the performance

More information

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications NiCd battery Maintenancefree solution for backup power applications The ideal choice for total security and availability Saft your trusted battery partner for stationary applications Saft has over 100

More information

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty Page 1 Table of Contents Introduction Page 3 Overview Page 3 Setup and Operation Page 5 Remote Control Page 6 Power Management Page

More information

RG 7 SERIES AIRCRAFT BATTERY OWNER/OPERATOR MANUAL

RG 7 SERIES AIRCRAFT BATTERY OWNER/OPERATOR MANUAL RG 7 SERIES AIRCRAFT BATTERY OWNER/OPERATOR MANUAL CONCORDE BATTERY CORPORATION 2009 San Bernardino Road West Covina, CA 91790 Phone: 626-813-1234 www.concordebattery.com Document No. 5-0324 Revision C

More information

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products

More information

SOLAR PV SYSTEM MAINTENANCE GUIDE

SOLAR PV SYSTEM MAINTENANCE GUIDE SOLAR PV SYSTEM MAINTENANCE GUIDE GUYANA HINTERLANDS STAND-ALONE SOLAR PV INSTALLATIONS IMPROVING HEALTH FACILITY INFRASTRUCTURE (IHFI) GUYANA CONTRACT NO. EPP-I-00-03-00008-00, TASK ORDER 07 APRIL 2013

More information

Material Safety Data Sheet

Material Safety Data Sheet 1. Product & Company Identification: Product: Conrad Energy Kamera-Akku Manufacturer: Conrad Electronic SE Nominal capacity: 1500 mah Nominal voltage: 7,4 V Address: Klaus-Conrad-Strasse 1, D-92240 Hirschau

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller EPSOLAR Utility model patent NO. 201120064092.1 Tracer-2210RN / 2215RN Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL Thank you very much for selecting our product! This manual

More information

Li Battery Pack & Charger Safety & Operating Instructions

Li Battery Pack & Charger Safety & Operating Instructions Li Battery Pack & Charger Safety & Operating Instructions NEUTON Power Equipment 75 Meigs Road Vergennes, VT 05491 Toll-Free phone: 1-866-NEUTON1 (638-8661) Fax: 1-802-877-1213 Website: www.neutonpower.com

More information

Apple Product Information Sheet 20 Watt Hours

Apple Product Information Sheet 20 Watt Hours Apple Product Information Sheet 20 Watt Hours The products referenced herein are articles and consumer products and therefore are excepted from the 29 CFR 1910.1200 Hazard Communication requirements. The

More information

Guide rail bracket (for adjustable heads)

Guide rail bracket (for adjustable heads) (for adjustable heads) Part. 209 40 ø,5 ø10,5 2 2,5 115 15 42 5 11 37 72 4 70 Code 209 / 0754 MATERIALS: Bracket made out of reinforced polyamide black colour. FEATURES: To be used with heads Part.221,

More information

Battery Handbook. By: RON SMITH

Battery Handbook. By: RON SMITH Battery Handbook By: RON SMITH Information compiled from the Battery Charger Handbook and the Battery Handbook written by Alvin G. Graham, Chief Engineer, Ratelco Electronics Inc. Introduction The purpose

More information

BATTERY CHARGER MULTI US 7000

BATTERY CHARGER MULTI US 7000 US Switch Mode BATTERY CHARGER For lead-acid batteries 14-150 Ah MULTI US 7000 User s Manual and a guide to professional battery charging For Starter/Deep Cycle batteries INTRODUCTION The MULTI US 7000

More information

TELEDYNE BATTERY PRODUCTS

TELEDYNE BATTERY PRODUCTS TELEDYNE BATTERY PRODUCTS LT Valve-Regulated Lead-Acid Batteries Part Numbers Applicable to This CMM 7639-27 7638-44 7641-20 7035-28 7243-16 7025-20 7243-14 7638-44T PROPOSITION 65 WARNING BATTERY POSTS,

More information

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel MANUAL CONGRATULATIONS on the purchase of your new CTEK professional battery management unit. This unit is part of a range of professional battery chargers from CTEK SWEDEN AB. It represents the latest

More information

BATTERY CHARGER OWNER S MANUAL

BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for the automatic battery charger. Do not expose charger to rain or snow. Do not use and an attachment not recommended

More information

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E SENS part no: 101314 Document revision: F DCN No. 106811 Date 8/3/15 1840 Industrial Circle Longmont, CO 80501 Fax: (303) 678-7504

More information

NI-ZN BATTERY SPECIFICATION

NI-ZN BATTERY SPECIFICATION NI-ZN BATTERY SPECIFICATION 252000 Model Name: AA2500mWh(Ni-Zn) Issued Date: Sept. 2010 NICKEL ZINC BATTERY SPECIFICATION 1.APPLICATION The applicable range: This specification is available only for the

More information

Substation Battery & Charger Maintenance

Substation Battery & Charger Maintenance Document title AUTHORIZED COPY Substation Battery & Charger Maintenance Document number MNT-TRMX-00015 Applies to: Keywords: Transmission Operations & Planning Department Carolinas and Florida maintenance;

More information

Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal

Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal PRODUCT SAFETY PRECAUTIONS FOR HANDLING AND USE DURACELL alkaline manganese cells and batteries will provide long, reliable and safe service when used correctly. To achieve optimum performance and trouble-free

More information

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

6 & 12 Volt Battery and Systems Tester with 100 Amp Load 6 & 12 Volt Battery and Systems Tester with 100 Amp Load Form No. 841-731 -000 DESCRIPTION This Load Tester tests 6 or 12 volt automotive-size lead-acid batteries under load. It will also test 6 or 12

More information

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

A reasonable, new furnace (mid efficiency) has the following electrical requirements: June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,

More information