BNI IOL-709-000-K006 BNI IOL-710-000-K006. IO-Link Sensor-Hub analog User s Guide



Similar documents
BNI EIP Z009 IP67 Module, Unmanaged Switch

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

BNI EIP Z015 IP67 Modules 4 IO Link/In-/Outputs,12 In-/Outputs User s Guide

Evaluation Board. i-modul and Socket. Manual

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

BK MIKRO9. Tool monitoring system. Getting Started with Profibus Release 1.00 /

Wind Sensor W-RS485 with RS485 Interface

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Combi switchbox with integrated 3/2 way pilot valve

Series 7500 Torque Sensor

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Original instructions Tina 3A/Aps Adaptor unit

ZC-24DO CANopen I/O Module: 24 Digital Outputs

PTU Series Transducer Digital Display Indicator User s Manual

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Addendum to the Operating Instructions

How To Set Up An Inverter

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

DK40 Datasheet & Hardware manual Version 2

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Electronic Pressure Switch EDS 3000

BL compact multiprotocol station for Industrial Ethernet SSI interface BLCEN-1M12MT-1SSI

96 Variants. The GlobalProx range increases in popularity. 12 PNP Normally-open 12 PNP Normally-closed 12 NPN Normally-open 12 NPN Normally-closed

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

How To Use A Power Supply On A Powerline 2.2 (Ai)

MADRIX NEO Quick Start Guide & User Manual

Push button 3gang standard flush-mounted xx

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Allen-Bradley/Rockwell

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Model: DC-A2IO Advanced HVAC Controller

MODULAR JUNCTION BOX MJB WITH GATEWAY

Tina 2A/B Adaptor unit

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Users manual. TCW181B-CM_R1 Page 1

Technical Information

Modular I/O System Analog and Digital Interface Modules

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DMX2PWM 9 Channel Dimmer Setup Manual

Waveguide Access Point WGA631. Product Guide

Multi-Protocol decoder with Load regulation

SR450 RECEIVER OPERATING INSTRUCTIONS

Series BOS 5K. ... simply good

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

L5354 ControlNet Communications Interface

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Series 6000 Torque measured metal bellow coupling

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

IP Box Camera ACM Ver Hardware User s Manual

Color Mark Sensor with Red or Green LED E3S-VS

Light scene push button 8gang comfort flush-mounted xx

ABSOLUTE ROTARY ENCODER ETHERNET/IP

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

CONFIGURABLE SAFETY RELAYS

FM4100 USER MANUAL V1.4

Digital display DA 48

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

MANUAL FOR RX700 LR and NR

D93-226D Xico, Inc Eton Avenue Chatsworth, CA USA SERIES 3600 SWIPE MAGNETIC STRIPE CARD READERS

Model SPDT Relays

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

User Manual. AS-Interface Programmer

GAE953 Electrical Alarm Unit 19" with Indicator

USER MANUAL V5.0 ST100

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

DMX USB PRO. User Manual.

Conductive Level Switch FK 2 Technical Data:

Technical description MX-1 VB Edge

Part Number Description Packages available

Rack mounted telephone- and leased line modem for industrial applications

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Transcription:

BNI IOL-709-000-K006 BNI IOL-710-000-K006 IO-Link Sensor-Hub analog User s Guide

Inhalt 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross-references 2 1.4 Symbols 2 1.5 Abbreviations 2 2 Safety 3 2.1 Intended use 3 2.2 General safety notes 3 2.3 Meaning of the warnings 3 3 Getting Started 4 3.1 Connection overview 4 3.2 Mechanische Anbindung 5 3.3 Electrical connection 5 3.4 Function ground 5 3.5 IO-Link connection 5 3.6 Digital Sensors 6 3.7 Analog Sensors 6 4 IO-Link Interface 7 4.1 IO-Link Daten 7 4.2 Process data inputs 7 4.3 Process data outputs 8 4.4 Parameter data/ On-request data 8 Identification data 8 9 Switch point enable 9 Switch point 9 4.5 Errors 10 4.6 Events 10 5 Technical Data 11 5.1 Dimensions 11 5.2 Mechanical data 11 5.3 Electrical data 11 5.4 Operating conditions 11 5.5 Function indicators 12 Module LEDs 12 Digital Input LEDs 12 Analog Input LEDs 12 6 Appendix 13 6.1 Type designation code 13 6.2 Order information 13 www.balluff.com 1

IO-Link Sensor-Hub BNI IOL-709- / BNI IOL-710-1 Notes to the user 1.1 About this guide This guide describes the Balluff IO-Link sensor collector module, also called the Sensor Hub. Connection to the host interface master is made through the IO-Link protocol. Functionally this compact, cost-effective module is comparable with a passive splitter box: It takes digital and analog sensor signals and passes them over the IO-Link interface. 1.2 Structure of the guide 1.3 Typographical conventions Enumerations Actions Syntax The Guide is organized so that the sections build on one another. Section 2 : Basic safety information. Section 3 : The main steps for installing the device. Section 4: IO-Link, parameter and process data for the device. Section 5: Technical data for the device.. The following typographical conventions are used in this Guide. Enumerations are shown in list form with bullet points. Entry 1, Entry 2. Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow. Action instruction 1. Action result. Action instruction 2. Numbers: Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00 hex). Cross-references Cross-references indicate where additional information on the topic can be found (see Section 5 -"Technical Data ). 1.4 Symbols Note! This symbol indicates a security notice which most be observed. Note tip This symbol indicates general notes. 1.5 Abbreviations BCD BNI CV DPP I-Port EMC FE IOL LSB MSB SP SPDU VV Binary coded switch Balluff Network Interface Current Version: BNI IOL 709 Direct Parameter Page Digitaler input port Electromagnetic Compatibility Function ground IO-Link Least Significant Bit Most Significant Bit Switch Point Service Protocol Data Unit Voltage version: BNI IOL 710 www.balluff.com 2

2 Safety 2.1 Intended use The BNI IOL- is a decentralized sensor input module which is connected to a host IO-Link master over an IO-Link interface. 2.2 General safety notes Installation and startup Installation and startup are to be performed only by trained specialists. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer's guarantee and warranty. The device is an equipment in accordance with EMC Class A. Such equipment may generate RF noise. The operator must take precautionary measures accordingly. The device must be powered only using an approved power supply (see Section 5 Technical Data ). Only approved cables may be used. Operation and testing The operator is responsible for observing local prevailing safety regulations. When defects and non-clearable faults in the device occur, take it out of service and secure against unauthorized use. Approved use is ensured only when the housing is fully installed. 2.3 Meaning of the warnings Note! The pictogram used with the word "Caution" warns of a possible hazardous situation affecting the health of persons or equipment damage. Ignoring these warnings can result in injury or equipment damage. Always observe the described measures for preventing this danger. www.balluff.com 3

IO-Link Sensor-Hub BNI IOL-709- / BNI IOL-710-3 Getting Started 3.1 Connection overview 1 Mounting hole 2 IO-Link interface 3 Analog input-port 1 4 Status-LED: Analog port 5 Analog input port 3 6 Status-LED: digital input Pin 2 7 Digital input port 1 8 Status-LED: Digital port Pin 4 9 Digital input port 3 10 Status LED Power Supply 11 Digital input port 2 12 Digital input port 0 13 Analog input port 2 14 Analog input port 0 15 Label 16 Status-LED COM 17 Function ground connection www.balluff.com 4

Fehler! Kein Text mit angegebener Formatvorlage im Dokument. im Dokument. Fehler! Kein Text mit angegebener Formatvorlage 3.2 Mechanische Anbindung 3.3 Electrical connection The BNI IOL modules are attached using 3 M4 screws (Item 1, Fig. 3-1/3-2). The Sensor Hub modules require no separate supply voltage connection. Power is provided through the IO-Link interface by the host IO-Link Master. 3.4 Function ground The modules are provided with a ground terminal. Connect Sensor Hub module to the ground terminal. Note! The FE connection from the housing to the machine must be low-impedance and as short as possible. 3.5 IO-Link connection The IO-Link connection is made using an M12 connector (A-coded, male). IO-Link (M12, A-coded, male) Pin Function 1 Supply voltage, +24 V, max. 1.6 A 2-3 GND, reference potential 4 C/Q, IO-Link data transmission channel 5 FE, function ground Connection protection ground to FE terminal, if present. Connect the incoming IO-Link line to the Sensor Hub. Note! A standard sensor cable is used for connecting to the host IO-Link Master. www.balluff.com 5

IO-Link Sensor-Hub BNI IOL-709- / BNI IOL-710- Fehler! Kein Text mit angegebener Formatvorlage im Dokument. im Dokument. Fehler! Kein Text mit angegebener Formatvorlage 3.6 Digital Sensors Digital input port (M12, A-coded,female) Pin Function 1 +24 V, 100 ma 2 Standard Input 3 0 V, GND 4 Standard Input 5-3.7 Analog Sensors Analog input port (M12, A-coded, female) Note! For the digital sensor inputs follow the input guideline per EN 61131-2, Type 2. Pin Function 1 +24 V, 100 ma 2 BNI IOL-709...: 4-20 ma BNI IOL-710 :n.c. 3 0 V, GND 4 BNI IOL-710...: 0-10 V BNI IOL-709 :n.c 5 FE, function ground Note! Unused I/O port sockets must be fitted with cover caps to ensure IP67 protection rating. www.balluff.com 6

Error 1 Error 2 Error 3 Error 1 Error 2 Error 3 Error 1 Error 2 Error 3 Error 1 Error 2 Error 3 Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin4 Switch Point 1 Port 3 Switch Point 1 Port 2 Switch Point 1 Port 1 Switch Point 1 Port 0 Input Port 7.Pin 2 Input Port 6.Pin 2 Input Port 5.Pin 2 Input Port 4.Pin 2 Switch Point 2 Port 3 Switch Point 2 Port 2 Switch Point 2 Port 1 Switch Point 2 Port 0 4 IO-Link Interface 4.1 IO-Link Daten Baudrate COM2 (38,4 kbaud) Frame type 1 Minimum cycle time 3 ms Process data cycle 30 ms bei minimaler Zykluszeit 4.2 Process data inputs BNI IOL-710- /BNI IOL-709- (Sensor-Hub digital/analog) Process data length 10Byte: Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Byte 2 Byte 3 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 0 M Analog value L S S B B Port 0 Byte 4 Byte 5 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 0 M Analog value L S S B B Port 1 Byte 6 Byte 7 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 0 M Analog value L S S B B Port 2 Byte 8 Byte 9 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 0 M Analog value L S S B B Port 3 www.balluff.com 7

Identification Data Read only IO-Link Sensor-Hub BNI IOL-709- / BNI IOL-710- Fehler! Kein Text mit angegebener Formatvorlage im Dokument. im Dokument. Fehler! Kein Text mit angegebener Formatvorlage Input: Switch Point: Analogwert: Error: Error 1 Error 2 Error 3 Input-Signal at Port and Pin The switch point bits show a switch point overrun. The switch point can be configured by parameter ( see 0.0 - Switch point enable and 0.0 - Switch point ) VV: actual voltage value between 0 and 1056mV, 1Bit = 0.01V CV: actual current value between 0 and 21,5mA (dez. 0 2150) 1Bit = 0.001A Overcurrent/short circuit on sensor supply Measerment range overflow Measerment range undercut (only CV) 4.3 Process data outputs There are no outputs at BNI IOL-710-... and BNI IOL-709-... modules. 4.4 Parameter data/ On-request data DPP SPDU Parameter Data Index Index Subindex width 07hex Vendor ID 2 Byte 08hex 09hex Device ID 3 Byte 0Ahex 0Bhex 10hex 0 Vendor Name 8 Byte 11hex 0 Vendor text 16 Byte 12hex 0 Product Name 34 Byte 13hex 0 Product ID 21 Byte 14hex 0 Product text 34 Byte 16hex Hardware Revision 3 Byte 17hex 0 Firmware Revision 3 Byte Access Identification data Type Device ID Version BNI IOL-710-000-K006 050201hex Voltage version BNI IOL-709-000-K006 050202hex Current version www.balluff.com 8

Enable switch point 2 Port 3 Enable switch point 2 Port 2 Enable switch point 2 Port 1 Enable switch point 2 Port 0 Enable switch point 1 Port 3 Enable switch point 1 Port 2 Enable switch point 1 Port 1 Enable switch point 1 Port 0 Port 7 Pin 4 Port 6 Pin 4 Port 5 Pin 4 Port 4 Pin 4 SP1 Port 3 SP1 Port 2 SP1 Port 1 SP1 Port 0 Port 7 Pin 2 Port 6 Pin 2 Port 5 Pin 2 Port 4 Pin 2 SP2 Port 3 SP2 Port 2 SP2 Port 1 SP2 Port 0 Parameter Data Fehler! Kein Text mit angegebener Formatvorlage im Dokument. im Dokument. Fehler! Kein Text mit angegebener Formatvorlage DPP SPDU Parameter Data width Value range Default- Index Index Subindex value 10hex 40hex 0 11hex 64 1-16 2 Byte 0000hex FFFFhex 0000hex 12hex 41hex 0 65 1-8 Switch point enable 1 Byte 00hex FFhex 00hex 42hex 66 43hex 67 44hex 68 45hex 69 46hex 70 47hex 71 48hex 72 49hex 73 0 Switch point 1 Port 0 2 Byte 0000hex 03E8hex 0000hex 0 Switch point 1 Port 1 2 Byte 0000hex 03E8hex 0000hex 0 Switch point 1 Port 2 2 Byte 0000hex 03E8hex 0000hex 0 Switch point 1 Port 3 2 Byte 0000hex 03E8hex 0000hex 0 Switch point 2 Port 0 2 Byte 0000hex 03E8hex 0000hex 0 Switch point 2 Port 1 2 Byte 0000hex 03E8hex 0000hex 0 Switch point 2 Port 2 2 Byte 0000hex 03E8hex 0000hex 0 Switch point 2 Port 3 2 Byte 0000hex 03E8hex 0000hex of the input signals: Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Switch point enable Enable the sitch points by setting the enable bits Byte 0 7 6 5 4 3 2 1 0 Switch point Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 0 0 0 0 Switch point Wertebereich (dez) CV= 400 2000 VV= 0 1000 www.balluff.com 9

Parameter Data IO-Link Sensor-Hub BNI IOL-709- / BNI IOL-710-4 Fehler! Kein Text mit angegebener Formatvorlage im Dokument. 4.5 Errors Byte 0 Byte 1 11hex Index not available Device application error: 80hex 12hex SubIndex not available 30hex Value out of range 4.6 Events Class/Qualifier Code (high + low) Mode Type Instance Device Supply low appears Error AL supply Hardware voltage U2 = supply + 24V C0hex 30hex 03hex 5000hex 0100hex 0010hex 0002hex F3hex disappears Error AL Device Hardware supply 5112hex Supply low voltage U2 = supply + 24V 80hex 30hex 03hex 5000hex 0100hex 0010hex 0002hex B3hex appears Error AL Device Hardware supply 5112hex supply periphery C0hex 30hex 03hex 5000hex 0100hex 0060hex F3hex disappears Error AL Device Hardware supply 5160hex supply periphery 80hex 30hex 03hex 5000hex 0100hex 0060hex B3hex 5160hex www.balluff.com 10

5 Technical Data 5.1 Dimensions 5.2 Mechanical data Housing Material Plastic, transparent IO-Link-Port M12, A-coded, male Input-Ports Enclosure rating Weight Dimensions (L W H, excluding connector) 8x M12, A-coded, female IP67 (only when plugged-in and threaded-in) 90 g 115 50 30,8 mm 5.3 Electrical data Operating voltage 18... 30,2 V DC, per EN 61131-2 Ripple < 1 % Current draw without load 40 ma 5.4 Operating conditions Operating temperature -5 C +55 C Storage temperature -25 C +70 C EMC EN 61000-4-2/3/4/5/6 Severity level 4A/3A/4B/2A/3A Vibration/shock EN 60068 Teil 2-6/27 www.balluff.com 11

IO-Link Sensor-Hub BNI IOL-709- / BNI IOL-710- Fehler! Kein Text mit angegebener Formatvorlage im Dokument. im Dokument. Fehler! Kein Text mit angegebener Formatvorlage 5.5 Function indicators Module LEDs LED 5, IO-Link Communikation Status Function Green Green negativ pulsed Red Off No Communikation Communikation OK Communication line overload Module unpowered LED 4, Power supply status Status Function Green Module power is OK Green slowly flashing Aus Module power supply < 18 V Module unpowered Digital Input LEDs LED 3, Input Pin 4 and LED 2, Input Pin 2 Status Function Yellow Input signal = 1 Off Input signal = 0 Analog Input LEDs LED 1, Analog input port Status Signal 709 (4-20 ma) Signal 710 (0-10 V) Grün 4 ma - 20 ma > 0,05 V Rot < 4 ma - > 20 ma > 10,05 V www.balluff.com 12

6 Appendix 6.1 Type designation code BNI IOL-7xx-000-K006 Balluff Network Interface IO-Link interface Functions 710 = 8 digital inputs 0,15 A + 4 analog inputs 0-10 V 709 = 8 digital inputs 0,15 A + 4 analog inputs 4-20 ma Variant 000 = Standardvariante Mechanical configuration K006 =Plastic housing, Connectors: - BUS and Power supply: 1x M12x1, external thread - Input ports: 8x M12x1, internal thread 6.2 Order information Type Order Code BNI IOL-709-000-K006 BNI0007 BNI IOL-710-000-K006 BNI0008 www.balluff.com 13

IO-Link Sensor-Hub BNI IOL-709- / BNI IOL-710- Notes www.balluff.com 14

Nr. 868249 E Edition 1105 Replaced by 0803 Subject to modification www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Tel. +49 7158 173-0 Fax +49 www.balluff.com 7158 5010 balluff@balluff.de