Control. Line. Thermostat. Pressure Switch Hot Surface Element. Output Ratings. Inducer Fan. Hot Surface Element. Gas Valve Rating.

Similar documents

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table


G670 Intermittent Pilot Ignition Controls

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Model Description / Applications. Intermittent Pilot Gas Ignition Control

, User s Manual

80UHG. Service Literature

INSTALLATION & SERVICE MANUAL. Display Panel

DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

Installation Instructions

Digi-Motor Installation Guide

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Fossil fuel heating equipment

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

WARNING CAUTION 21V51U-843 DESCRIPTION PRECAUTIONS

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

Operating Instructions

i ChatterBox! Motorcycle Security

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

DKG 972 Gas Burner Safety Control

Luna 3 Comfort Troubleshooting Guide June 2008

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

User Manual for CH-PFC76810

Original instructions Tina 3A/Aps Adaptor unit

Fan Coil EC Motor Control

TC-9102 Series Surface Mount Temperature Controllers

37E73A-903 & 906 INTELLI-VENT

12 Volt 30 Amp Digital Solar Charge Controller

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Advantium 2 Plus Alarm

VX 2400 Dimmer User's Manual

Cooling Capacity CFM in. w.c. (125 Pa)

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Your safety and the safety of others are very important.

PRODUCT DESIGN. 5. Furnace awaits call from thermostat.

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

PUSH BUTTON START INSTALLATION MANUAL

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

The Ultimate Truck Stock Motor

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Gas Oven Repair Guide

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Manual for Fire Suppression & Methane Detection System

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

StructureScan HD Module. Installation Guide ENGLISH

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Digital Keypad Use s Manual

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

PRO PLM Installation Instructions

Commercial Gas Water Heaters

Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Operating Instructions. UL325 Compliant Non-monitored

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

ADM1TE 5/30A DIN rail single phase two wire energy meter

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Technical Data. Dimensions

Thermo Top - Troubleshooting Tree

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

S8910U Universal Hot Surface Ignition Module

Tina 2A/B Adaptor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

ELECTRIC CENTRAL HEATING FLOW BOILER

F9MXE. Product Specifications

Mobile Device Power Monitor Battery Connection Quick Start Guide

Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION GUIDE. FCC ID NOTICE

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Mobile Data Power Model: MDP-25

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Heating Basics Gas Valve Systems

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

T-100-R Installation Guide

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

Manual. Simrad StructureScan LSS-1 Sonar Module. English

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Transcription:

SERIES 35-67 24 VAC Proven Hot Surface Ignition Control with Combustion Blower Relay Microprocessor Based 35.67.02 FEATURES Proven pressure switch input Combustion fan output 24/120/240 VAC hot surface ignitor models available ASME CSD-1 compatible models available (consult factory) Pre-purge and lockout indicator outputs Diagnostic LED Multiple trials for ignition Thermostat, pushbutton or remote reset Remote diagnostic LED Remote flame sensor option Flame current test pins APPLICATIONS Commercial and industrial appliances with combustion chambers in excess of 400K BTU. Applications requiring CSD-1 certification. DESCRIPTION The Series 35-67 is a hot surface ignition system in which the ignition source is proven to be capable of ignition prior to the gas valve being opened and is suitable for appliances over 400K BTU. Models compatible to the requirements of ASME standard CSD-1 are available. The microprocessor circuit design provides precise, repeatable timing sequences for ignition times and purge times (pre-, inter-, and post-) as well as multiple tries for ignition. The control also continuously monitors the pressure switch, thermostat and main burner flame to ensure safe system operation. On-board diagnostics with LED output provide assistance with troubleshooting to ensure safe and efficient burner operation. Agency Certifications Design certified by CSA International to CAN C22.2 #199-M89 and ANSI Z21.20 for Automatic Ignition Systems, including UL1998 Software Review. SPECIFICATIONS INPUT VOLTAGES Control Line Thermostat Pressure Switch Hot Surface Element Output Ratings Inducer Fan Hot Surface Element Gas Valve Rating Lockout & Pre-Purge Indicators Operating Temperature Flame Sensitivity Flame Failure Response Time Types of Gas Ignitor Enclosure Moisture Resistance Size with enclosure Weight DESCRIPTION 18 to 30 VAC, 400mA max (not including gas valve) 24/120/240 VAC (L1 & L2 only, voltage depends on model) 18 to 30 VAC 30mA max (incl. Gas Valve) 18 to 30 VAC 25mA max 24/120/240 VAC 5A max Relay: 15A max or 1/3HP @ 120 or 240 VAC 5.0A max @ 24, 120 or 240 VAC 5.0A max @ 24 VAC 1.0A max @ 24 VAC -40ºF to +165ºF (-40ºC to +73ºC) 4.0mA minimum 0.8 seconds max Natural, LP, or manufactured 24 VAC, 120 VAC, or 240 VAC mini-ignitors and silicon carbide ignitors depending on model Gray (Noryl N-190) Conformal coated to operate non-condensing to 95% R.H. Care must be taken to protect module from direct exposure to water See Figures 6 & 7 8oz including options and cover Series 35-67, 24 VAC Hot Surface Ignition Control Page 1

SEQUENCE OF OPERATION 1. POWER-UP. Power is applied to the full time 24 volt input. The microprocessor will start a self-check routine of about five seconds. After this delay, the LED will come on and the control is ready to start a new call for heat. For Manual Reset Button Models Only Models of the 35-67 with non-volatile lockout (manual reset button), the microprocessor will check memory to determine if the control should remain in lockout. Lockout Present. The lockout indicator output will turn on, and the LED will repeatedly flash three times. To reset the control, the Reset Button must be pushed. Not in Lockout. The control is ready to start a new call for heat. 2. CALL FOR HEAT. The thermostat is turned on. The combustion fan relay will turn on. Proof of Pressure Switch. The control will look for a signal from the pressure switch, indicating that the fan has come on. Pre-Purge Delay. When the pressure switch signal is seen, the pre-purge delay will start. The pre-purge indicator output will turn on. 3. HEAT-UP. After the pre-purge delay, power will be applied to the hot surface ignition element. The pre-purge indicator will turn off. Current Proving. The 35-67 will monitor the current through the ignition element. When the current reaches a pre-determined level, the LED will flash once. Dwell Time. From the point when the current has been proven, there will be a delay called dwell time. Dwell time assures that the ignition element has sufficient time to reach ignition temperature. Post-Purge. After all ignition cycles are complete, the control will enter post-purge. The combustion fan will remain on. Lockout. After post-purge is complete, the combustion fan will turn off. The Lockout Indicator output will turn on. The LED will repeatedly flash three times SILICON CARBIDE IGNITOR Proper location of the silicon carbide ignitor is important to achieve optimum system performance for both ignition and flame sensing. See Figure 1. NOTE: The temperature of the ceramic holder should not exceed the manufacturer's specifications. Figure 1 TYPICAL HOT SURFACE IGNITOR Figure 2 Figure 3 4. IGNITION. When dwell time is completed, the gas valve will open. The ignition element will turn off 2 seconds before the end of the ignition period. No Flame. Single Trial for Ignition. The control will go to post-purge, and then lockout. Three Trials for Ignition. The control will make two additional purge/heatup/ignition cycles. If a flame is not proven, the control will go to post-purge, and then lockout. Flame is Proven. The gas valve will remain on beyond the normal ignition period. This continues as long as signals are present for the flame, thermostat and pressure switch. 5. LOSS OF FLAME SIGNAL. The gas valve will turn off. Depending on the model chosen: Single Trial for Ignition Models. A new trial for ignition cycle will start. Three Trial for Ignition Models. Three new ignition cycles will start. continued above > Flame current is the current that passes through the flame from the sensor to ground. The minimum flame current necessary to keep the system from lockout is 4.0 microamps. To measure flame current, connect an analog DC micro-ammeter to the FC terminals per figure 5. Meter should read 4.0 ma or higher. If meter reads below "0" on scale, meter leads are reversed. Disconnect power and reconnect meter leads for proper polarity. Page 2 Series 35-67, 24 VAC Hot Surface Ignition Control

MOUNTING AND WIRING The 35-67 is not position sensitive and can be mounted vertically or horizontally. The control may be mounted on any surface and fastened with #6 sheet metal screws. Secure the control in an area that will experience a minimum of vibration and remain below the maximum ambient temperature of 80 C (175ºF). All connections should be made with UL approved, 105 C (221 F) rated 18 gauge stranded wire with.054" minimum insulation. Refer to Figure 4A and Figure 5A on Page 5 when connecting the 35-67 to other components in the system. #! #! CAUTION: Label all wires prior to disconnection when servicing the control. Wiring errors can cause improper and dangerous operation. A functional checkout of a replacement is recommended. WARNING: Operation outside specifications could result in failure of the Fenwal product and other equipment with injury or death to people and damage to property. Service to this product should only be preformed by a qualified technician TERMINAL DESIGNATIONS - P1 CONNECTOR Table 1 MULTI-PIN CONNECTOR AMP P/N 1-770849-1 PINS AMP P/N 350980-1 PIN LOCATION 1 2 3 4 5 6 7 7 8 9 10 11 TERMINAL DESIGNATIONS - P2 & P3 CONNECTOR Table 2 WIRE COLOR ORANGE RED VIOLET GRAY BROWN BLUE YELLOW GREEN WHITE BLACK DESCRIPTION Lockout Indicator Thermostat Lockout Indicator (Ground Side) Pressure Switch Gas Valve 24 VAC (Full Time) No Connection (Standard Version) Reset Button (Manual Reset Only) Ground Pre-Purge Indicator Remote Sense TERMINAL DESCRIPTION MULTI-PIN CONNECTOR S1 L1 L2 S2 F1 F2 P3 FC+ & FC- Ignitor 24, 120 or 240VAC Input (Hot) Neutral Ignitor Inducer Power Supply Inducer Blower Remote LED Connector Flame Current Test Pins AMP 2-520183-2 PINS 350919-3 AMP 2-520183-2 PINS 350919-3 AMP 2-520183-2 PINS 350919-3 AMP 2-520183-2 PINS 350919-3 MOLEX 22-01-2021 PINS 08-500114 AMP 61260-1 QUICK CONNECTS ON BOARD DIAGNOSTICS LED INDICATION Steady OFF 2 Flashes 3 Flashes 6 Flashes SYMPTOM Control will not start up Thermostat on and no igniton Valve on - no ignitor Ignitor on - no valve Flame okay during TFI but no flame sense after TFI FAULT MODE Internal Control Failure Erroneaus Flame Signal Lockout Valve Relay Problem TROUBLESHOOTING GUIDE RECOMMENDED ACTIONS A. Miswired B. 24 VAC Transformer bad C. Fuse/Circuit breaker bad D. Bad control, check LED for steady or flashing codes A. Miswired B. Bad thermostat, no voltage at thermostat terminal C. Failed ignitor A. Defective ignitor B. Miswired C. Bad control, check voltage at ignitor A. Valve coil open B. Open valve wire C. Bad control, check voltage at gas valve terminal A. Bad ignitor B. Bad wire C. Poor ground at burner D. Poor flame, check flame current Series 35-67, 24 VAC Hot Surface Ignition Control Page 3

CONTROL WIRE HARNESS Select the proper harness based on the 35-67 control's termination connection. Once the terminal configuration is determined, complete the part number by replacing the last two digits ("XX") with the length in inches ("l" dimension). Standard wire lengths are 12, 18, 24 30, 36 and 48 inches. Example 05-129845-018 = 18 inches. For other lengths, please contact Fenwal Part Number: 05-129845-0XX Part Number: 05-128981-XXX REMOTE FLAME SENSE ROD Part Number: 22-100001-080 Part Number: 22-100001-110 Page 4 Series 35-67, 24 VAC Hot Surface Ignition Control

STANDARD DESIGN - AUTOMATIC RESET WIRING Figure 4A PIN LAYOUT Figure 5A Series 35-67, 24 VAC Hot Surface Ignition Control Page 5

OPTIONAL DESIGN - MANUAL RESET WIRING Figure 4B PIN LAYOUT Figure 5B Page 6 Series 35-67, 24 VAC Hot Surface Ignition Control

DIMENSIONS Figure 6 Figure 7 Series 35-67, 24 VAC Hot Surface Ignition Control Page 7

CONTROL CONFIGURATION 35-67 X X X X - X X X Description Trial for Ignition 0 = 2 Seconds 1 = 4 Seconds 3 = 7 Seconds 5 = 10 Seconds 7 = 15 Seconds Proving Current (Amps) 0 = 0.8 1 = 0.5 3 = 2.1 4 = 2.3 5 = 2.7 6 = 3.1 7 = 3.3 Purge Timing 0 = 0 Prepurge, 0 Interpurge, 0 Postpurge 1 = 15 Prepurge, 15 Interpurge, 0 Postpurge 2 = 30 Prepurge, 30 Interpurge, 0 Postpurge 3 = 0 Prepurge, 15 Interpurge, 0 Postpurge (3 Try Units Only) 4 = 0 Prepurge, 30 Interpurge, 0 Postpurge (3 Try Units Only) 5 = 15 Prepurge, 15 Interpurge, 30 Postpurge (Full Time Power) 6 = 30 Prepurge, 30 Interpurge, 30 Postpurge (Full Time Power) 7 = 0 Prepurge, 15 Interpurge, 15 Postpurge (Full Time Power) 8 = 0 Prepurge, 30 Interpurge, 30 Postpurge (Full Time Power) Tries For Ignition 0 = Single Try - Local Sense. Recycle On Flame Loss 1 = Single Try - Remote Sense. Recycle On Flame Loss 2 = Single Try - Local Sense. Lockout On Flame Loss 3 = Single Try - Remote Sense. Lockout On Flame Loss 5 = Three Tries - Local Sense. Recycle On Falme Loss 6 = Three Tries - Remote Sense. Recycle On Falme Loss 7 = Three Tries - Local Sense. Lockout On Flame Loss 8 = Three Tries - Remote Sense. Lockout On Flame Loss Dwell Time 0 = 4 Seconds 1 = 6 Seconds 5 = 20 Seconds 7 = 40 Seconds Proven Pressure Switch, Full Time Power, Termination 0 = No Full Time Power, Q.C. Terminals, No Local Reset Button 1 = No Full Time Power, Mate-N-Lock, No Local Reset Button 2 = Full Time Power, Q.C. TERMINALS, No Local Reset Button 3 = Full Time Power, Mate-N-Lock, No Local Reset Button 4 = No Full Time Power, Q.C. Terminals, Local Reset Button 5 = No Full Time Power, Mate-N-Lock, Local Reset Button 6 = Full Time Power, Q.C. Terminals, Local Reset Button 7 = Full Time Power, Mate-N-Lock, Local Reset Button 8 = Aftermarket Kits (Consult Factory for Special Number) 9 = Special OEM Features (Consult Factory for Special Number) Other Features 0 = No Indicators With No Inducer 1 = No Indicators With Inducer 2 = No Indicators With No Inducer 3 =Indicators and Inducer 9 = Manual Reset (Standard Includes Indicators and Inducers) 400 MAIN STREET, ASHLAND, MA 01721 TEL: (508) 881-2000 FAX: (508) 881-6729 These instructions do not purport to cover all the details or variations in the equipment described, nor do they provide for every possible contingency to be met in connection with installation, operation and maintenance. All specifications are subject to change without notice. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes, the matter should be referred to KIDDE-FENW- AL, Inc., Ashland, Massachusetts. 2003 Kidde-Fenwal Printed in U.S.A. TAG P/N 35.67.02 2/15/03 Page 8 Series 35-67, 24 VAC Hot Surface Ignition Control