INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters
|
|
|
- Beverly Cain
- 10 years ago
- Views:
Transcription
1
2
3 INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters Printed in the USA 0605 Part No. GTC-070 R3 Revision 2 includes updated troubleshooting information for error codes 3, 4, and 6. Revision 3 includes updated troubleshooting for error codes 4 and 6 and technical bulletins
4 INTELLI-VENT TROUBLESHOOTING GUIDE INTELLI-VENT FEATURES The Intelli-Vent is a combination control incorporating all temperature control, ignition control, blower and ignitor control, flame sensing, and gas regulation into a single device. Advanced Diagnostics - Error Codes The Intelli-Vent features advanced diagnostics with 15 specific error codes including reversed polarity and inadequate grounding notification. Diagnostic information is conveyed via 6 LED lights on the control. These error codes will help diagnose and repair the water heater quickly and accurately. Tamper Resistant The Intelli-Vent features tamper resistant temperature settings. In order to access temperature settings both temperature adjust buttons must be pressed simultaneously for one full second to review the temperature settings. Temperature settings are displayed by illuminating various combinations of LED lights. Precise Temperature Control The Intelli-Vent controls temperature electronically. Tighter cut out and cut in differentials produce less temperature swing than standard residential controls. Temperature Probe - Thermistor The temperature probe houses the ECO and a temperature sensor which is a thermistor. Thermistors are thermally sensitive variable resistors. A change in water temperature changes the resistance (measured in ohms) of the thermistor. The Intelli-Vent control interprets this change in resistance as a change in temperature and uses this information to activate and deactivate a call for heat. Silicon Nitride Ignitor The Intelli-Vent control uses a silicon nitride ignitor which is more durable than the silicon carbide ignitors previously used. Body oils transferred to the ignitor during handling will not damage silicon nitride ignitors nor will minor bumps or drops. This ignitor is also highly resistant to damage caused by condensation. Adaptive Learning Technology Adaptive Learning Technology refers to the programed control of voltage to the ignitor. The Intelli- Vent varies voltage to the ignitor and learns to use the lowest voltage necessary that insures consistent ignition. Lower voltage increases ignitor life. Water Resistant While not being a water proof control the Intelli-Vent control does have a greater degree of resistance to water damage than previous controls. Wiring connections are on the bottom of the control and less susceptible to damage. Technical Training Department Ashland City, Tennessee of 24
5 INTELLI-VENT TROUBLESHOOTING GUIDE INTELLI-VENT CONSTRUCTION Temperature Probe/ECO Supply Gas Connection Future side connect model is shown here. Top connect models are in use currently. Front & Left Side View 6 LED indicator lights Temperature Settings Error Codes / Diagnostics Temperature adjust buttons Temperature adjust buttons must be pressed together for one second to wake up the control in order to view or change temperature settings. Manifold Gas; Main Burner Connection RH thread Natural LH thread Propane Manifold Gas Pressure Tap Control Information 6 Pin Molex Plug Line Voltage Blower Voltage Pressure Switch Right Side View 5 Pin Molex Plug Hot Surface Ignitor Flame Sensor Resistor Wire Bottom View Flame Sensor Silicon Nitride Ignitor (Hot Surface Ignitor) Ignitor Assembly Technical Training Department Ashland City, Tennessee of 24
6 INTELLI-VENT TROUBLESHOOTING GUIDE INTELLI-VENT OPERATION 6 LED indicator lights Temperature Settings Error Codes / Diagnostics Temperature adjust buttons PRE START UP CHECK LIST Correct polarity on electrical supply Water heater is properly grounded Owner s manual safety statements have been reviewed START UP PROCEDURE 1 Plug in water heater and turn on power. All lights on the control will come on for about 1-5 seconds. All lights will then turn off. If the stored water is above 70 F (residential) and the control setting has not been increased from it s factory setting, nothing more will happen. (Residential controls are factory set at 70 F, the vacation setting per ANSI requirements; Commercial controls are factory set at 120 F) 2 Wake Up the control by holding down both of the temperature adjust buttons at the same time for about one second; then release the buttons and the LED lights will indicate the current temperature setting. 3 Push then release the hotter temperature adjust button repeatedly to increase the water temperature setting and the colder temperature adjust button to decrease the setting. THE RECOMMENDED STARTING TEMPERATURE IS 120 F See the illustration on the following page indicating which temperature setting corresponds to the various combinations of LED lights. SLEEP MODE - NORMAL OPERATION Without any further user input the control will go back into the sleep mode in 30 seconds. All LED indicator lights will turn off. This is the normal operating mode. Technical Training Department Ashland City, Tennessee of 24
7 INTELLI-VENT TROUBLESHOOTING GUIDE TEMPERATURE SETTINGS Residential and commercial Intelli-Vent controls differ in appearance: The far left LED light is green on the residential control and the remaining 5 LEDs are yellow. On the commercial control all six LEDs are yellow. The residential control has a vacation temperature setting (70 F) and it is referenced on the display. There is no vacation setting on a commercial control. The residential control uses an inverted triangle (delta symbol) above the third LED and uses A, B, and C as temperature set point references. The commercial control places the inverted triangle above the far left LED and uses B, C, D, E, and F for temperature set point references. Residential Commercial Technical Training Department Ashland City, Tennessee of 24
8 INTELLI-VENT TROUBLESHOOTING GUIDE INTELLI-VENT SPECIFICATIONS INTELLI-VENT CONTROL SPECIFICATIONS Body Electrical Ratings Max Inlet Gas Pressure Temperature Range High Temp Cut Off - ECO ½ inch NPT inlet. ½ inch inverted flare outlet. (RH thread natural, LH thread propane) 120 VAC, 60 Hz, 1Ø, 5-7 FLA. Ignitor load: 2 amps maximum. Blower/inducer motors: 3 amps full load - 4 amps locked rotor. ½ PSI maximum (14.0" W.C.) F Residential F Commercial. 195 F Residential - single use (control must be replaced) 195 F Commercial - resettable (reset temp 120 F) OPERATING SEQUENCE Pre-Purge Time Ignitor Warm-up Time Trial for Ignition Period Inter-Purge Time Post-Purge Time Ignition Retries Ignition Recycles 5 seconds. 20 seconds. 4 seconds. 5 seconds. 5 seconds. 2 retries; 3 trials before lockout. 2 recycles, 3 losses of flame before lockout. GAS PRESSURE REQUIREMENTS NATURAL GAS Supply gas 4.5 to 5.0" W.C. minimum -14.0" W.C. maximum Always check control/water heater label Manifold gas 3.5 to 4.0" W.C. Always check control/water heater label PROPANE GAS Supply gas 11.0" W.C. minimum 14.0" W.C. maximum Manifold gas 10.0" W.C.. Manifold gas pressure is non adjustable. Always verify correct main burner orifice before replacing a control for failing to maintain correct manifold pressure. Technical Training Department Ashland City, Tennessee of 24
9 INTELLI-VENT TROUBLESHOOTING GUIDE INTELLI-VENT WIRING CONNECTIONS FEMALE MOLEX RECEPTACLES BOTTOM OF CONTROL Wiring Harness Connections Ignitor Assembly Connections Female Receptacle Female Receptacle Male Plug 1. = Air Pressure Switch Circuit 2. = 120 VAC Neutral Wire to Blower 3. = 120 VAC Hot Wire to Control 4. = Air Pressure Switch Circuit 5. = 120 VAC Hot Wire to Blower 6. = 120 VAC Neutral Wire to Control 1. = Ignitor hot wire 2. = Ignitor neutral wire 3. = Resistor wire 4. = Resistor wire 5. = Flame sense rod Black Resistor Wire (between pin 3 and 4) Male Plug There are two female Molex plug receptacles on the bottom of the Intelli-Vent control. Keep in mind the receptacles (female) and plugs (male) are mirror images of each other in regard to pin number location and retaining clip orientation. Pin numbers and corresponding component wiring are detailed above in relation to the retaining clip. The male plug ends from the 6 conductor wire harness and 5 conductor ignitor assembly plug are shown above; notice the raised ridges identifying the #1, #2, and #3 pins. A black marker was used to highlight these ridges for the photograph. Service Notes: The Black Resistor Wire on the ignitor assembly plug is used to provide proper sensory input in place of optional external variable resistance devices, none are currently used. This resistor wire must not be cut, removed, or jumpered. The Intelli-Vent control would interpret this as a component failure and lock out displaying error code 14 or 15. Pins and sockets inside the plugs and receptacles should be visually inspected to insure good connections are being made when servicing. Always depress retaining clip when unplugging Molex connectors, failure to do so can damage plug connection. Technical Training Department Ashland City, Tennessee of 24
10 INTELLI-VENT TROUBLESHOOTING GUIDE Wiring Harness Connection Diagram Models Equipped With Vent Temperature Limit Switch Technical Training Department Ashland City, Tennessee of 24
11 INTELLI-VENT TROUBLESHOOTING GUIDE INTELLI-VENT SEQUENCE OF OPERATION Technical Training Department Ashland City, Tennessee of 24
12 INTELLI-VENT TROUBLESHOOTING GUIDE INTELLI-VENT TROUBLESHOOTING GUIDE Error Codes & Diagnostics The Intelli-Vent control will not have any LED lights illuminated during normal operation (sleep mode) for the life of the water heater. When an LED is illuminated, it draws attention to the water heater and the need to have it serviced. There are 15 different diagnostic error codes the Intelli-Vent control is capable of displaying by illuminating various combinations of LED lights. All 15 are covered in the troubleshooting guide that follows. The same combination of LED lights are used for error codes on residential and commercial controls though the way they are displayed differs slightly: Residential controls display error codes via constant illumination of the LED lights. Commercial controls display error codes by flashing the LED lights on and off. Important Service/Installation Notes: 1 Always turn power off for 10 to 20 seconds and then back on again to clear an error code before replacing an Intelli-Vent control. 2 When installing the water heater or a replacement Intelli-Vent control, do not use the control face as a handle to move the water heater or turn (thread) the control. 3 When installing a replacement control do no pinch, pull, or cut exposed wires. Troubleshooting Guide Notes: Residential error code displays are shown on the left and commercial on the right for all 15 error codes that follow. LEDs filled in black indicate an Illuminated LED. ERROR CODE 1 - NO EARTH GROUND 1 Inadequate or no earth ground sensed by Intelli-Vent control. Check / Repair: Insure the wall outlet is properly grounded. Insure all ground connections on the water heater are secure. Insure ground path wires (if so equipped) between wiring boxes and heater jacket are properly secured. Insure the ground (green) wire in the power cord is continuous with an ohm meter. Technical Training Department Ashland City, Tennessee of 24
13 INTELLI-VENT TROUBLESHOOTING GUIDE ERROR CODE 2 - REVERSED POLARITY 2 Power supply to Intelli-Vent control has reversed polarity. Check / Repair: Insure the wall outlet is properly wired. Insure all internal 120 VAC wiring connections on the water heater are not reversed. 120 VAC hot wire should connect to the on/off switch. Insure the wiring harness between the Intelli-Vent control and the wiring box has no crossed wires with an ohm meter. (see 7) Double check all ground connections insure they are clean, tight, and intact. ERROR CODE 3 - PRESSURE SWITCH CIRCUIT REMAINS CLOSED 3 Pressure switch circuit (see 7) remaining closed for more than 5 seconds after heating cycle is activated. Blower does not start. Check / Repair: Insure air pressure switch circuit wiring is correct and the air pressure switch is not jumpered. Turn off power and unplug the water heater from wall outlet. Disconnect both wires from the air pressure switch terminals. Check between the wiring terminals of the air pressure switch with an ohm meter for continuity. A If pressure switch contacts show continuity (closed circuit) replace the pressure switch. B If pressure switch contacts show open circuit and all wiring is correct - replace Intelli-Vent control.. To verify a closed air pressure switch circuit is preventing the heat sequence from advancing (IE the combustion blower is not being energized): Turn off power & unplug the water heater from the wall outlet. Disconnect one wire from the air pressure switch (tape off end of wire - insure this wire does not touch ground). Plug the water heater back in and turn the power switch back on. If a call for heat is still present error code 3 should not return and the Intelli-Vent control should energize the combustion blower. Technical Training Department Ashland City, Tennessee of 24
14 INTELLI-VENT TROUBLESHOOTING GUIDE ERROR CODE 4 - PRESSURE SWITCH CIRCUIT REMAINS OPEN 4 Pressure switch circuit (see 7) remains open longer than 5 seconds after the combustion blower/inducer fan was energized by the Intelli-Vent control. Blower may run continuously in this condition. Check / Repair: Insure the blower is starting and coming up to speed, if the Intelli-Vent control will not energize the blower with the air pressure switch circuit open, replace the Intelli-Vent control (see footnote page10). Insure pressure switch wiring is correct (see wiring diagram page 7). Insure pressure switch sensing tube is not damaged/kinked and is properly connected. Insure vent system has been installed correctly: insure the correct size vent pipe was used. Insure the maximum number of elbows or equivalent feet of vent pipe has not exceeded the water heater manufacturer requirements. Insure a vent termination restrictor was not installed on vent installations that do not require it. (Do not install this restrictor when it is not required) See the A. O. Smith/ State Product Notifications for vent restrictor usage at the end of this manual. Clear any obstructions or restrictions in the exhaust vent or the intake air pipe. Defective air pressure switch; Check pressure switch contacts with ohm meter during blower operation; contacts should close (show continuity) after blower starts and comes up to speed. If air pressure switch contacts are not closing: Take air pressure reading (see page 23) with a digital manometer at the sensing port on the blower. Compare to manufacturer s specification for switch. If pressure reading taken is at or beyond activation point according to manufacturer s specification for the switch - replace air pressure switch. If pressure reading taken does not reach activation point for switch; Check for restrictions, too many elbows, or too many equivalent feet of vent/intake air pipe. Check for dirt/debris on blower wheel. Insure vent termination restrictor was not installed if it was not required. See 5th bulleted item above. Flue gas temperature in blower assembly is excessive, pressure switch circuit is open due to vent temperature limit switch activating (see wiring diagram page 7). Determine cause - flue baffle/restrictor missing/damaged or not installed correctly & make repairs. Defective vent temperature limit switch; this is a normally closed switch that opens its contacts on a rise in temperature. Turn off power and disconnect wires to the vent temperature switch. With the switch at room temperature (77 F), check for continuity between the two wiring terminals on switch with an ohm meter. If switch contacts are open at room temperature - replace the switch. Technical Training Department Ashland City, Tennessee of 24
15 INTELLI-VENT TROUBLESHOOTING GUIDE ERROR CODE 5 - IGNITOR FAILURE 5 The Intelli-Vent control has detected an open ignitor circuit. Check / Repair: Check all wiring to the hot surface ignitor. Check 5 pin Molex ignitor assembly plug and receptacle on the Intelli-Vent body for a good connection. Repair or replace parts if necessary. Check resistance of ignitor with an ohm meter between pin 1 and 2 on the ignitor assembly plug. Replace ignitor if resistance is not within 11.5 and 18.8 ohms. If above checks are good and ignitor resistance is within specification - replace the Intelli-Vent control. ERROR CODE 6 - IGNITION / FLAME FAILURE 6 The water heater has reached the maximum number of retries or recycles and is currently locked out for one hour. Cycle the power to the water heater off and on to reset. Check / Repair: Gas supply is off or too low of pressure to operate. Insure manifold gas pressure is present and within requirement. Insure the flame sensor is making good contact with the burner flame. See the Ignition and Flame Failure bulletin on page 16 and the burner check on page 18. Insure the flame sensor is clean - use steel wool to clean sensor. Insure flue restrictor (on models so equipped - see page 19) and flue baffle are installed properly. Flue restrictor must be flush on top of flue pipe. A disloged or missing flue restrictor/baffle can cause excessive air turbulence in the combustion chamber - sweeping all gas away from ignitor (no ignition) or the flame away from the sensor (short cycling burner). Insure vent termination restrictor (see product notification sheets at end of this publication) is installed when required. Insure the ignitor is positioned correctly for consistent ignition. Low voltage to the water heater. Should be VAC. Technical Training Department Ashland City, Tennessee of 24
16 INTELLI-VENT TROUBLESHOOTING GUIDE ERROR CODES - 7, 8, 9 - INTERNAL CONTROL FAILURES Self diagnostic tests have found a problem with the gas valve driver circuit, internal microprocessor, or the internal circuits. Check / Repair: Turn the power off for seconds then on again to clear these error codes. If any of these error codes persist or cannot be cleared - replace the Intelli-Vent control. ERROR CODE 10 - FLAME SENSED OUT OF SEQUENCE 10 Flame signal has been sensed out of proper sequence. Check / Repair: Insure flame sensor ceramic insulator is not cracked - replace ignitor assembly if defective. Turn the power off for seconds and then on again to clear this error code. Replace the Intelli-Vent control if this error code persists. Technical Training Department Ashland City, Tennessee of 24
17 INTELLI-VENT TROUBLESHOOTING GUIDE ERROR CODE 11 - HIGH TEMPERATURE CUTOFF (ECO) ACTIVATED 11 Water temperature in the tank exceeded 195 F and activated the ECO. Check / Repair: Turn the power off for seconds and then on again to clear this error code. Residential control - replace the control if the error code cannot be cleared. Commercial control - cool water temperature below 120 F, cycle power off and on to reset control. Replace the control if the error code persists. ERROR CODE 12 - TEMPERATURE ADJUST BUTTONS STUCK CLOSED 12 The self diagnostic check detected a temperature adjust button stuck closed. Check / Repair: Make sure no objects are leaning against the front of the control. Lightly press and release each of the buttons once. If the above actions do not clear the error, the control will continue to regulate water temperature at the last setting, but you will not be able to change settings unless you replace the Intelli-Vent control. ERROR CODE 13 - TEMPERATURE PROBE OPEN OR SHORTED 13 The self diagnostic test has detected the water temperature sensor (thermistor) is either open or short circuited. Check / Repair: Turn the power off for seconds then on again to clear this error code. This part of the control cannot be replaced or serviced. If the error code cannot be cleared, the Intelli-Vent control must be replaced. Technical Training Department Ashland City, Tennessee of 24
18 INTELLI-VENT TROUBLESHOOTING GUIDE ERROR CODE 14 - RESISTOR WIRE OPEN OR SHORTED 14 The self-diagnostic test found a problem with the black resistor wire on the ignitor assembly plug; the resistor wire is open or shorted. (see 6) Check / Repair: Insure the black resistor wire is not cut, missing, and is installed between pins 3 & 4 of the ignitor assembly plug. Replace ignitor assembly if damaged or defective. Unplug the ignitor assembly plug from the control. Check the resistance of the black resistor wire between pins 3 & 4 with an ohm meter. A If the reading taken is less than 2000 or more than 1.7 million ohms, replace the ignitor assembly. B If the reading taken is between 2000 and 1.7 million ohms, replace the Intelli- Vent control. ERROR CODE 15 - RESISTOR WIRE RESISTANCE OUT OF TOLERANCE 15 The self-diagnostic test determined the resistance of the black resistor wire on the ignitor assembly plug is not within tolerance. (see 6) Check / Repair: Unplug the ignitor assembly plug from the control. Check the resistance of the black resistor wire between pins 3 & 4 with an ohm meter. A If the reading taken is more than 50,000 ohms replace the ignitor assembly. B If the reading taken is less than 50,000 ohms replace the Intelli-Vent control. Technical Training Department Ashland City, Tennessee of 24
19 INTELLI-VENT TROUBLESHOOTING GUIDE TECHNICAL BULLETIN - IGNITION AND FLAME FAILURE A & S COMBINED This technical bulletin has been prepared to help diagnose and repair ignition and flame failure problems with White Rodgers Intelli-Vent equipped water heaters. Procedures to verify correct flame sensor alignment, burner assembly condition, and flue restrictor/baffle position are outlined in this bulletin. These procedures should help to identify and repair most ignition and flame failure problems. Always verify an adequate supply of fuel gas (manifold gas pressure) and combustion air when experiencing ignition or flame failure. Procedures for verifying an adequate supply of fuel gas and combustion air are detailed in the residential gas service handbook (A. O. Smith part number TC-049 R3, State Water Heaters part number STC-080) available through your local A. O. Smith or State Water Heaters sales representative or as free download from the web sites: If it is determined there is not a sufficient supply of combustion air or fuel gas, resolve these problems first. The test procedures outlined in this technical bulletin presume there is an adequate supply of both fuel gas and combustion air. FLAME SENSOR ALIGNMENT (Intelli-Vent equipped - standard recovery - 40 & 50 gallon residential water heaters) The lower lip or edge of a low NOx burner extends out further than it does on a standard burner. Flame sensor gap and elevation are measured from the lower lip on low NOx burners and from the top lip on standard burners as illustrated on the following page. The A. O. Smith Water Heater specifications given here are for standard recovery residential power vent and power direct vent 40 and 50 gallon models. GPSH 40, GPSH 50, GPDH 40, GPDH 50. Call the A. O. Smith Water Heaters technical information center ( ) for information on other models. The State Water Heater specifications here are for standard recovery residential power vent and power direct vent 40 and 50 gallon models. PR6 40 & 50 XCVIT (natural) or CCVIT (propane), PR6 40 & 50 XBPDT (natural) or CBPDT (propane). Call the State Water Heaters technical information center ( ) for information on other models. A. O. Smith State Technical Training Department Ashland City, Tennessee of 24
20 INTELLI-VENT TROUBLESHOOTING GUIDE FLAME SENSOR ALIGNMENT (CONT) Technical Training Department Ashland City, Tennessee of 24
21 INTELLI-VENT TROUBLESHOOTING GUIDE BURNER CHECK LIST REMOVE BURNER TO PERFORM THE FOLLOWING TESTS 1 Burner mounting screws. Check the two mounting screws that hold the burner head to the main burner tube. These screws being loose can cause poor burner grounding and diminished or lost flame sensing current which leads to burner short cycling and lockout.? 2 Ignitor assembly plug connection. Check the 5 pin Molex plug and the female receptacle in the control body to insure all conductors are present and making good contact. Wiggle both Molex plugs at the control body to check for poor connections if the Intelli-Vent control is not responding for any reason. 3 Ignitor assembly wires. Check the three wires between the ignitor assembly and the Intelli-Vent control. Insure these wires are not cut or damaged. Replace the Ignitor assembly if the wiring is damaged. 4 Ignitor assembly ceramic insulators. Make a close visual inspection of the ignitor assembly insulators. Insure the two ceramic insulators for the ignitor and flame sensor are not chipped or cracked. Replace the ignitor assembly if these insulators are damaged or defective. 5 Ignitor resistance test. Check the ignitor resistance with an ohm meter set on a low scale. Ignitor resistance should be between 11.5 and 18.8 ohms. If the resistance of the ignitor is not within this range, replace the ignitor. Worn or damaged ignitors can cause ignition failure and control lockout after three failed ignition attempts. 6 Flame sensor condition. Insure the flame sensor is free of rust and corrosion; clean the sensor with steel wool. Sand cloth can be used; be sure to clean off any residue left by the sand cloth. Rust or corrosion on a flame sensor will cause diminished or lost flame sensing current which leads to burner short cycling and control lockout after three failed ignition attempts. 7 Flame sensor (ignitor) alignment.?insure the flame sensor is aligned with the burner according to the specifications on the previous page of this bulletin. A misaligned flame sensor can lead to diminished or lost flame sensing current which causes burner short cycling and control lockout after three failed ignition attempts. If the flame sensor is aligned properly the ignitor should be positioned correctly also since both are fixed to a common assembly. 8 Low NOx screen clearance. On low NOx models, insure the low NOx screen is not touching either the ignitor or the flame sensor when installed inside the combustion chamber. This screen touching the flame sensor could cause a false flame sensing signal and control lockout. Technical Training Department Ashland City, Tennessee of 24
22 INTELLI-VENT TROUBLESHOOTING GUIDE FLUE BAFFLE & FLUE RESTRICTOR CHECK Flue baffle assembly shown to the left. Insure this is assembled and installed properly. This can become dislodged during transport. Always check the flue baffle assembly if the water heater has been laid on its side during transport. Some power vent residential models are equipped with flue restrictors in addition to the flue baffles installed on all models. The flue restrictor and flue baffle are engineered to precisely regulate the flow of flue gases through the flue pipe. This maximizes the amount of heat conducted into the water through the walls of the flue pipe. The flue restrictor and baffle will also affect the velocity of air being drawn into and through the combustion chamber. If the flue restrictor is dislodged as shown in the left illustration above, the velocity of air flowing through the combustion chamber will increase. This can cause air turbulence inside the combustion chamber that leads to: 1 Fuel gas being swept away from the ignitor leading to ignition failure (failure to ignite). The Intelli-Vent control would lockout after 3 failed attempts and display error code 6. 2 Ignition occurs but the air turbulence blows the flame away from the flame sensor causing burner short cycling. The Intelli-Vent control would lockout after 3 failed attempts and display error code 6. A dislodged flue restrictor or baffle can also allow too much heat to flow into the combustion blower and vent system leading to: 1 Vent temperature limit switch contacts opening during the heating cycle, preventing the thermostat from? satisfying. The Intelli-Vent control closes the gas valve immediately if this switch activates. 2 Heat damage to the combustion blower and/or vent system components. The outer and inner combustion chamber access covers and the fiberglass insulation between the outer jacket and the combustion chamber must also be installed correctly. If not installed properly this could also cause excessive air turbulence inside the combustion chamber. Insure these covers are installed correctly and the fiber glass insulation is not removed or tucked/pushed away from these openings when servicing. Insure the flue baffle, flue restrictor, combustion chamber access covers, and fiber glass insulation between the outer jacket and combustion chamber are all installed properly to minimize ignition and flame failure conditions. Technical Training Department Ashland City, Tennessee of 24
23 INTELLI-VENT TROUBLESHOOTING GUIDE TECHNICAL BULLETIN - AIR PRESSURE SWITCHES A & S COMBINED Air pressure switches are used on all fan assisted gas fired water heaters, residential and commercial. If the water heater was factory equipped with a combustion blower or inducer fan, by design the blower must running during the heating cycle. Air pressure switches are used to provide verification, or prove electrically, that the blower is running and the vent and/or combustion air piping is not blocked or restricted. The ignition control on these fan assisted boilers and water heaters senses when the air pressure switch circuit is open or closed. There is at least one air pressure switch in this circuit that has normally open contacts on all models (see page 5). As the blower starts and comes up to speed the normally open contacts on this air pressure switch will close in response to changes in vent system pressure. At the beginning of a heating cycle the ignition control will check if the air pressure switch circuit is open before the control energizes the blower motor. The ignition control will check the air pressure switch circuit a second time to insure it is closed after the blower is energized. The ignition control then monitors this circuit during the heating cycle to insure the circuit remains closed. If this circuit opens (even for a split second) during the heating cycle; the control will close the gas valve immediately to insure safe operation. In this way an ignition control can perform three critical diagnostic checks using a single air pressure switch: 1 Verify the normally open air pressure switch contacts are not stuck closed or jumpered. 2 Verify the combustion blower or inducer fan is running. 3 Verify the vent and/or combustion air piping remain free of restrictions. Pressure switch construction, operation, testing, the various types of pressure switches and their wiring are explained in this bulletin. Technical Training Department Ashland City, Tennessee of 24
24 INTELLI-VENT TROUBLESHOOTING GUIDE AIR PRESSURE SWITCH CONSTRUCTION The switch below has normally open switch contacts that close on a fall in pressure. Normal State Activated State Sensing port Wiring terminals Switch contacts Diaphragm Vent port AIR PRESSURE SWITCH OPERATION Air pressure switches activate in response to changes in air pressure sensed through a plastic tube attached to a sensing port on the water vent system and/or blower housing. The diaphragm divides the body of the switch into two air chambers. The air chamber the sensing port is attached to is sealed. The other chamber is vented to the atmosphere which allows the diaphragm to move up and down. There is linkage that attaches the switch contacts to the diaphragm so that when the diaphragm moves the contacts are activated. The term activate means to change state. If the contacts are normally open, activating the contacts will cause them to close. If the contacts are normally closed, activating the contacts will cause them to open. Service Note: Because one of the two air chambers is vented to the atmosphere, the ambient air pressure in the installed space is critical. If the ambient air pressure is below atmospheric (outdoor) air pressure, it will pull on the pressure switch diaphragm. If the ambient air pressure is above atmospheric it will push on the pressure switch diaphragm. In either condition the pressure switch will not operate as designed if the pressure imbalance is severe enough. Correcting an air pressure imbalance between the installation space and the outdoors can be achieved by providing adequate make up air openings. Direct vent installations will not eliminate this potential problem. Technical Training Department Ashland City, Tennessee of 24
25 INTELLI-VENT TROUBLESHOOTING GUIDE AIR PRESSURE SWITCHES - DIFFERENT TYPES SWITCH CONTACTS Normally Open = NO Normally Closed = NC SWITCH ACTION Close on a rise in pressure Close on a fall in pressure Open on a rise in pressure Open on a fall in pressure The switches shown here are all SPST switches. SPST = single pole, single throw. Power Vent and Power Direct Vent residential products use the first type shown below. Normal State Activated State Normally open contacts, close on a fall in pressure. Normally closed contacts, open on a fall in pressure. Normally open contacts, close on a rise in pressure. Normally closed contacts, open on a rise in pressure. Technical Training Department Ashland City, Tennessee of 24
26 INTELLI-VENT TROUBLESHOOTING GUIDE AIR PRESSURE SWITCH TESTING Continuity test with ohm meter Taking an air pressure reading To test the performance of an air pressure switch you must know the design activation point. This will be a given pressure value, either negative (in a vacuum) or a positive pressure. Contact the technical information center for this information or to locate a service handbook for the product you are working on. A. O. Smith Water Heaters; State Water Heaters; Have the complete model, serial, and series number on hand. Testing air pressure switch performance requires a digital or incline manometer that will read pressures at the expected activation point to within 1/100th of an inch of water column ( W.C.) at times. Digital manometers are typically less expensive and quicker to use than incline manometers. Manufacturers include Dwyer, UEI, and Bacharach. A good range of operation would be W.C. to W.C. Must be sensitive to 1/100th W.C.. With the sensing tube removed from the vent system sensing port, attach the manometer to the port, start the water heater and when the blower comes up to speed record the pressure reading. If the pressure reading does not reach the activation point for the pressure switch, the vent system must be checked for restrictions, too many elbows, or too many equivalent feet of piping. Consult the owners manual for complete venting requirements. Inspect/clean the blower as necessary. The state of the air pressure switch contacts can be checked with an ohm meter for continuity. A normal state test would be done with the power off and the wires to the switch removed. If the switch is a normally open switch and the continuity test showed continuity through the contacts; the switch is defective and must be replaced. A normally closed switch would be defective if it showed no continuity under these conditions. An operational test would be performed during blower operation with the wires to the air pressure switch removed and the sensing tube attached at both ends. With an ohm meter check continuity between the two wiring terminals on the pressure switch after the blower comes up to speed. If the pressure reading taken previously is at or beyond the activation point for the pressure switch and the pressure switch contacts do not activate, the pressure switch is defective and must be replaced. Technical Training Department Ashland City, Tennessee of 24
27 INTELLI-VENT TROUBLESHOOTING GUIDE AIR PRESSURE SWITCH CIRCUITS Air Pressure Switch Circuit - Residential Power Vent/Power Direct Vent 1 Blocked Exhaust Switch Normally Open Contacts Close on a Fall in Pressure Vent Temperature Limit Switch Normally Closed Contacts Open on a Rise in Temperature Molex Plug 6 Pin Plug 4 Technical Training Department Ashland City, Tennessee of 24
28 No.: ARGPN0305N Date: March 18, 2005 Vent Termination Restrictor Usage for 40,000 Btu Power Vent Models This bulletin will simplify vent termination restrictor usage for the 40,000 Btu power vent models and allowable venting distances. Power vent models, 40,000 Btu, manufactured prior to November 2004 (serial number K04) are shipped with a vent kit that includes a 2" restrictor (1 ¾ inside opening) and 2 tee. These kits are used for 2 vent installations up to 33 equivalent (not to exceed 33 feet) feet of vent pipe (2 restrictor is not needed if the vent run is longer than 33 equivalent feet) and a 3 restrictor and 45 degree elbow for 3" vent installations of any vent length (up to the maximum distance of 38 equivalent feet). These restrictors are to be installed in the vent termination tee or elbow if the vent is less than distances listed above. In November 2004 (serial number L04), the 2 restrictor (in the old vent kit) was replaced with a new 2" restrictor (1 ¼ inside opening) and the 3 restrictor was dropped from the kit. The venting distance requiring the use of the restrictor was reduced to 20 feet or less with this change. This means that if the vent distance is greater than 20 feet the restrictor is not needed. The series numbers (100 & 101) did not change with the revision to these kits. However, the termination tee that we have been buying/using, since November 2004 has the 2 restrictor installed in the tee. If the vent length is more than 20 feet the 2 restrictor in not needed and the restrictor must be removed from the tee or the pressure switch will not make and the heater will not operate. The restrictor s affect is resistance or restriction and on short vent runs this helps maintain energy factors. If used on longer vent runs (2 pipe over 20 feet), it adds too much restriction and the pressure switch will not let the heater operate. With all of that said, we are about to switch to a new series of power vent models (series 102 & 103) that will not use a restrictor in the vent termination. You should start seeing this new series of power vent models by month end, as inventory levels begin to diminish. The new heaters will have different blower, baffle and burner assembly (no NOx screen on the burner).
29 No.: S425 Date: 10/21/04 Vent Termination Restrictor Usage for 40,000 Btu Power Vent Models This bulletin will simplify vent termination restrictor usage for the 40,000 Btu power vent models and allowable venting distances. Power vent models, 40,000 Btu, manufactured prior to November 2004 (serial number K04) are shipped with a vent kit that includes a 2" restrictor (1 ¾ inside opening) and 2 tee. These kits are used for 2 vent installations up to 33 equivalent (not to exceed 33 feet) feet of vent pipe (2 restrictor is not needed if the vent run is longer than 33 equivalent feet) and a 3 restrictor and 45 degree elbow for 3" vent installations of any vent length (up to the maximum distance of 38 equivalent feet). These restrictors are to be installed in the vent termination tee or elbow if the vent is less than distances listed above. In November 2004 (serial number L04), the 2 restrictor (in the old vent kit) was replaced with a new 2" restrictor (1 ¼ inside opening) and the 3 restrictor was dropped from the kit. The venting distance requiring the use of the restrictor was reduced to 20 feet or less with this change. This means that if the vent distance is greater than 20 feet the restrictor is not needed. The model numbers did not change with the revision to these kits. However, the termination tee that we have been buying/using, since November 2004 has the 2 restrictor installed in the tee. If the vent length is more than 20 feet the 2 restrictor in not needed and the restrictor must be removed from the tee or the pressure switch will not allow the heater to operate. The restrictor s affect is resistance or restriction and on short vent runs this helps maintain energy factors. If used on longer vent runs (2 pipe over 20 feet), it adds too much restriction and the pressure switch will not let the heater operate. With all of that said, we are about to switch to a new series of power vent models (series 102 & 103) that will not use a restrictor in the vent termination. You should start seeing this new series of power vent models by month end, as inventory levels begin to diminish. The new heaters will have different blower, baffle and burner assembly (no NOx screen on the burner).
30 Additional copies are available from the Ashland City Advertising Department Prepared by the A. O. Smith/State Water Heater Technical Training Department Ashland City, Tennessee
31 TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION Inadequate or no earth ground sensed by the Intelli-Vent control. Power supply to Intelli-Vent control has reversed polarity. Pressure switch circuit remaining closed for more than 5 seconds after heating cycle begins. Blower does not start. Service Note: Secure power - disconnect one wire from the air pressure switch or the vent temperature limit switch. Turn power back on - blower should start. Pressure switch circuit remains open longer than 5 seconds after the blower is energized. Blower may run continuously in this condition. Service Note: To learn more about performing Air Pressure Switch tests visit our web site to download technical bulletin TB-A Air Pressure Switches. The Intelli-Vent control has detected an open ignitor circuit. Service Note: Ignitors are wearing parts; the resistance (ohms) of a hot surface ignitor will increase over time. If the resistance at room temperature is near 18.8 ohms - consider replacing the ignitor as a preventative measure. 1 Ensure the wall outlet is properly grounded. 2 Ensure all ground connections/wires on the water heater are secure. 1 Ensure the wall outlet is properly wired. 2 Ensure all internal 120 VAC wiring connections and wiring harness have no reversed wires. 120 VAC hot wire must connect to the on/off switch. 1 Ensure air pressure switch circuit wiring is correct and the air pressure switch is not jumpered. 2 Secure power to water heater, check continuity of air pressure switch contacts with wires disconnected. A If pressure switch contacts show continuity (closed circuit) replace the pressure switch. B If pressure switch contacts are open and all wiring is correct - turn the power off for seconds then on again to clear the error code - if the error code persists replace the Intelli-Vent control. 1 Ensure the blower is running - check for 120 VAC to the blower when the heating cycle begins, check the wiring. If the control does not energize the blower - replace the Intelli-Vent control. If the blower fails to start when energized - replace the blower assembly. 2 Ensure the air pressure switch sensing tube is properly connected - not kinked or damaged. 3 Check continuity of vent temperature limit switch - replace switch if contacts remain open under 160 F. 4 Ensure the correct size of vent pipe (2, 3, 4 ) was used per the installation manual for vent length. Ensure maximum number of elbows or equivalent feet of vent pipe has not exceeded maximum limits. 5 Ensure there are no obstructions in the vent pipe. 6 Check air pressure switch performance - check pressure with a digital manometer - check continuity of contacts. (see service note in left column) If the switch proves defective - replace the air pressure switch and/or the blower assembly as required. 7 If air pressure switch performance test results prove the air pressure switch is working properly and error code 4 persists - replace the Intelli-Vent control. 1 Check wiring to the hot surface ignitor - replace ignitor assembly if wiring is damaged or worn. 2 Check ignitor assembly plug and the socket on the Intelli-Vent body for good connection. Replace ignitor assembly and/or control if necessary. 3 Check resistance of ignitor at room temperature (77 F) at the plug end. Replace ignitor if resistance is not within 11.5 and 18.8 ohms at room temperature. 4 If results from the above tests were good and error code 5 persists - replace the Intelli-Vent control. A. O. Smith Water Products Company AHSTB02807 Technical Training Department Ashland City, Tennessee of 5 Intelli-Vent Trouble Chart FVIR AOS.fm
32 TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION Ignition/flame failure. The water heater has reached the maximum number of retries and is currently locked out for one hour. Cycle the power to the water heater off and on to reset. Service Note: Ignitors are wearing parts; the resistance (ohms) of a hot surface ignitor will increase over time. If the resistance at room temperature is near 18.8 ohms - consider replacing the ignitor as a preventative measure. Self diagnostic tests have found a problem with the gas valve driver circuit, internal microprocessor, or other internal circuits. 1 Gas supply is turned off - pressure too low. Ensure supply and manifold gas pressures are within requirements in the installation manual. Manifold gas pressure is non-adjustable if pressure is off by more than 0.3 W.C. replace the Intelli-Vent control. 2 Low supply voltage - should be VAC. 3 Ensure flame sensor is making good contact with the burner flame, ensure flame is steady see #8 below. 4 Ensure the flame sensor is clean - use ultra fine steel wool or Scotch-Brite pad to clean flame sensor. 5 Ensure the hot surface ignitor is positioned to provide consistent ignition. 6 Check for any cracks in ignitor assembly ceramic insulators - replace ignitor assembly if damaged. 7 Check resistance of ignitor at room temperature (77 F) at the plug end. Replace ignitor if resistance is not within 11.5 and 18.8 ohms at room temperature. 8 Ensure the correct size of vent pipe (2, 3, 4 ) was used per installation manual for vent length. Using larger pipe than required may cause excessive air turbulence in the combustion chamber. 1 Turn the power off for seconds then on again to clear these error codes. 2 If any of these error codes persist or cannot be cleared - replace the Intelli-Vent control Flame signal has been sensed out of proper sequence. Water temperature in the tank has exceeded 195 F and has activated the ECO. The self diagnostic check detected one or both of the temperature adjust buttons are stuck. The self diagnostic test has detected the water temperature sensor (thermistor) is either open or shorted. 1 Turn the power off for seconds and then on again to clear this error code. 2 Replace the Intelli-Vent control if this error code persists. 1 Turn the power off for seconds then on again to clear this error code. 2 Replace the control if the error code persists. 1 Press and release temperature adjust buttons. If the above action does not clear the error, the control will continue to regulate water temperature at the last setting. However, settings will no longer be adjustable - the control should be replaced. 1 Turn the power off for seconds then on again to clear this error code. 2 Replace the Intelli-Vent control if this error code persists. A. O. Smith Water Products Company AHSTB02807 Technical Training Department Ashland City, Tennessee of 5 Intelli-Vent Trouble Chart FVIR AOS.fm
33 TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION 14 The self diagnostic test has detected the flammable vapor sensor is either open or shorted. The Intelli-Vent control is programed to lock-out and display this error code if the resistance value it senses from the FV sensor is below 5,000 ohms or above 1,700,000 ohms. Service Note: To perform this test the ohm meter used must be capable of reading up to 2,000,000 ohms. Flammable Vapor Sensor Location / Testing 1 Turn off power to the water heater. Ensure all FV sensor wiring, the ignitor assembly plug, and the ignitor assembly socket on the bottom of the Intelli- Vent control are making good contact. Repair or replace any worn/damaged components that are not making a good connection. 2 Restore power to the water heater - if the error code has cleared place the water heater back in operation and allow it to cycle several times to ensure the problem has been resolved. If the error code persists - continue to step 3 below. 3 Turn off power to the water heater. Remove the FV sensor from it s bracket on the base ring of the water heater and disconnect both wires to the sensor. Take a resistance reading between the two wiring terminals of the FV sensor and note the resistance value. Service Note: Unless the ohm meter used has an auto-range feature the resistance should be checked twice. The first reading will be taken using an ohms scale above 1,700,000 ohms. The second reading is taken using an ohms scale just above 5,000 ohms. 4 If resistance of the FV sensor is lower than 5,000 ohms - replace the FV sensor. 5 If resistance of the FV sensor is above 1,700,000 ohms - replace the FV sensor. 6 If the resistance of the FV sensor is above 5,000 ohms and lower than 1,700,000 ohms and all the above steps have been performed - ensure the wiring and plug between the sensor and the Intelli- Vent control are not damaged or worn - replace the ignitor assembly if the wiring and/or plug are damaged/worn. If the wiring and plug are in good condition - replace the Intelli-Vent control valve A. O. Smith Water Products Company AHSTB02807 Technical Training Department Ashland City, Tennessee of 5 Intelli-Vent Trouble Chart FVIR AOS.fm
34 TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION 15 The self diagnostic test has detected the presence of flammable vapors. The Intelli-Vent control is programed to lock-out and display this error code if the resistance value it senses from the FV sensor is above 70,000 ohms but remains below 1,700,000 ohms. The Intelli-Vent control is in a hard lock-out condition that cannot be reset by cycling power to the water heater. See the instructions below for the reset procedure. 1 Turn off power to the water heater. Carefully check the surrounding area for any substances such as gasoline, paint, paint thinners, or cleaners that could emit flammable vapors. Remove anything that can potentially emit flammable vapors from the area and store it properly in a different location. 2 Ensure power to the water heater is turned off. Remove the FV sensor from it s bracket on the base ring of the water heater and disconnect both wires to the sensor. Take a resistance reading between the two wiring terminals of the FV sensor and note the resistance values. Perform this test once in the area by the water heater and a second time outdoors after allowing the sensor to acclimate to the outdoor atmosphere for 5 minutes. Service Note: These resistance readings should be taken using an ohm scale above70,000 ohms. 3 If the resistance of the FV sensor is above 70,000 ohms during the indoor test only and the resistance reading taken in the outdoor atmosphere dropped below 70,000 ohms. Re-check the area surrounding the water heater for substances that could be emitting flammable vapors. Remove any such substances from the area and store them properly in a different location. Repeat step 2. 4 If the resistance of the FV sensor is above 70,000 ohms during the indoor and outdoor tests - replace the flammable vapor sensor. 5 If the resistance of the FV sensor was below 70,000 ohms during the indoor and outdoor tests and all the steps above have been performed - replace the Intelli-Vent control. Flammable Vapors Sensed (FVS) Reset Procedure After a flammable vapor lockout has been initiated, a manual reset must be performed to restore operation. The following should be done by a qualified service person after the hazard has been removed: 1 Manual reset is accomplished by first, turning off power to the water heater for 10 seconds. 2 Restore the power to the water heater. 3 Within 10 seconds of restoring power, press the two temperature adjust buttons simultaneously until the left (green) Vacation LED begins to blink (approx. 5 second delay). Once the Vacation LED begins to blink, release both buttons. 4 Again, within 10 seconds, press both temperature adjust buttons simultaneously until the Vacation LED is on steady (approx. 5 second delay). 5 Release the two buttons, the microcomputer will clear the FVS lock-out and normal operation will then be restored. A. O. Smith Water Products Company AHSTB02807 Technical Training Department Ashland City, Tennessee of 5 Intelli-Vent Trouble Chart FVIR AOS.fm
35 TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION 16 LDO (Lint, Dust, and Oil) lockout condition. Air pressure switch circuit is opening repeatedly during one heating cycle. May be caused by the air pressure switch and/or the vent temperature limit switch (these two switches are wired together in a series circuit). 1 Check/clean intake air screen on the base ring of the water heater. 2 Check/clean the dilution air screen on the blower assembly. 3 Check/clean the flame arrestor - see the service note below. 4 Remove the blower assembly and check the flue baffle - ensure the flue baffle is in good condition and properly installed - reinstall as necessary and/or replace the flue baffle if worn or damaged. 5 Ensure water heater is not over-firing - check burner orifice size - ensure the correct orifice is installed - replace as necessary. 6 Ensure water heater is not over-firing - check manifold gas pressure - ensure manifold gas pressure is within 0.3 W.C. of the listed rating on the Intelli-Vent control valve. Manifold gas pressure is non-adjustable, if manifold gas pressure is off by more than 0.3 W.C. - replace the Intelli-Vent control. 7 Check the vent temperature limit switch - if it is determined that the vent temperature limit switch is opening its contacts at normal operating temperatures during the heating cycle - replace the vent temperature limit switch. Service Note: the flame arrestor is accessible through the intake air opening in the base ring of the water heater with the intake air screen removed. Use a non-metallic household brush to clear away any lint or dust from the ceramic flame arrestor, then vacuum the surface of the flame arrestor and the base ring air chamber thoroughly with a household vacuum cleaner. A suitable vacuum hose attachment can be fabricated in the field using a short length of 1/2 PVC pipe with a short radius elbow on one end. Use tape to temporarily seal it to the vacuum hose. Additional Recommended Service Publications Power-Vent service manual - part number TC-048 R6 (revision 6 or later) Intelli-Vent service manual supplement - part number GTC-070 R3 (revision 3 or later) Air Pressure Switches technical bulletin - number TB-A Visit our web site at to download the above service manual and supplement. Revision numbers for these service publications are designated by R3, R4, R6, R7, etc. as a suffix to the part numbers IE: GTC-070 R4 A. O. Smith Water Products Company AHSTB02807 Technical Training Department Ashland City, Tennessee of 5 Intelli-Vent Trouble Chart FVIR AOS.fm
36
37 Air Pressure Switches Tuesday, January 16, 2007 This bulletin has been prepared to explain and illustrate the construction, operation, and testing procedures for various types of air pressure switches used on residential and commercial tank type water heaters. Air pressure switches are used on all fan assisted gas fired water heaters in our product line. Air pressure switches are used to verify that operational conditions are being met; IE: the blower is running or the vent/combustion air piping length is not excessive or obstructed. Air pressure switches are usually wired together with other switches into a series circuit (see page 8). The ignition control constantly monitors the state of the air pressure switch circuit - whether it is open or closed. There will always be at least one air pressure switch that has normally open contacts (see pages 7 & 8). As the blower starts and comes up to speed the normally open contacts of this switch should activate (contacts will close) in response to the pressure it senses as long as there are no adverse operating conditions. Normal Operating Sequence - Pressure Switch Circuit (Power-Vent, Power Direct-Vent, Cyclone, Master-Fit BTN/BTI models) 1. At the beginning of a heating cycle the ignition control will verify the air pressure switch circuit is open before the control energizes the blower motor. 2. After successfully completing the above open circuit verification step, the ignition control will energize the blower, the control will then check the air pressure switch circuit a second time after the blower is energized. This time the pressure switch circuit must be verified closed. The ignitor would not be energized unless this circuit closes after the blower is energized. 3. The ignition control monitors this circuit during the entire heating cycle to ensure it remains closed. If this circuit opens (even for a split second) during the heating cycle; the control will close the gas valve and stop the heating cycle. By monitoring the air pressure switch circuit an ignition control can perform critical operational checks such as: 1. Verify normally open air pressure switch contacts are not stuck closed or jumpered. 2. Verify the combustion blower or inducer fan is running. 3. Verify the vent/combustion air piping length is not excessive and/or obstructed. Paul Stewart Technical Training Department A. O. Smith Water Products Company Ashland City, Tennessee Technical Bulletin TB-A AHSA of 8
38 Air Pressure Switch Construction Normal State (open switch contacts) Sensing Port Wiring Terminals Activated State (closed switch contacts) Switch Contacts Internal Linkage Flexible Diaphragm Vent Port Air Pressure Switch Operation Air pressure switches activate in response to pressure sensed through a tube. One end of this tube attaches to the pressure switch sensing port, the other end attaches to a pressure sensing port somewhere on the water heater, IE: the vent system, blower assembly. A flexible diaphragm divides the body of the switch into two air chambers. The sensing port is attached to one air chamber. The other air chamber is vented to the atmosphere which allows the diaphragm to move. Internal linkage attaches the switch contacts to the diaphragm; with sufficient pressure applied, diaphragm movement will activate the switch contacts. Contact States: The state of the contacts refers to whether or not the switch contacts are open or closed. Closed contacts will allow electricity to flow through the switch because there is a continuous conductive path through the switch contacts. Open contacts will not allow electricity to flow, there is no continuity through the switch contacts. The state of the contacts, open or closed, can be verified/confirmed with an ohm meter. An ohm meter is required to perform conclusive diagnostic tests on air pressure switches. With air pressure switches the term normal state refers to whether or not the switch contacts are open or closed when there is no pressure applied to the switch. Switches can be normally open or normally closed, abbreviated NO or NC in technical literature. The activated state of a switch is the opposite of the normal state. A normally open switch in it s activated state is closed. A normally closed switch in it s activated state is open. Air pressure switches are described by their normal state and by their contact action which is covered on the following page. AHSA of 8
39 Air Pressure Switch Operation (cont) Contact Actions: The action of the contacts refers to what causes the switch to activate, to change from it s normal state to its activated state (see page 2). On an air pressure switch this can be either a rise or fall in pressure. As the illustrations below indicate, locating the sensing port above or below the flexible diaphragm facilitates these operational differences. The contact action is further described to convey whether the contacts will open or close when the pressure sensed is sufficient to activate the switch contacts, IE: close on a fall in pressure. Pressure Switch Descriptions: Air pressure switches are described and referred to by their Contact State and Contact Action. IE: the switch on the left side in the illustration below is a normally open, close on a fall pressure switch. See page 7 for more information about other types of switches. Normally Open, Close on a Fall Normally Open, Close on a Rise Sensing Port Above Diaphragm (a fall in pressure or vacuum activates the switch) Vent Port Flexible Diaphragm Sensing Port Beneath Diaphragm (a rise in pressure activates the switch) Service Note: Because one of the two air chambers is vented to the atmosphere, the ambient (in the surrounding area) air pressure is critical. Ambient air pressure can push or pull on the diaphragm through the vent port. If the ambient air pressure is extremely high (positive) or low (negative) it may cause erratic pressure switch operation. Direct vent installations will not eliminate this potential problem. Tools Required for Testing A volt/ohm multi-meter - Fieldpiece HS36 DMM (digital multi-meter) or equivalent. A digital manometer is also required to measure pressure and perform conclusive diagnostic tests. Specifications: range; -15.0" W.C. to +15.0" W.C. resolution; 0.01" W.C. Brands/models recommended that meet these specifications include: UEI model EM-200 and Extech model dual pressure reading digital manometers. AHSA of 8
40 Air Pressure Switch Testing Continuity Test With Ohm Meter Power-Vent Residential Model Continuity Test With Ohm Meter BTH Blocked Exhaust Switch Testing the performance of air pressure switches involves three procedures. First Procedure is a normal state test to determine if the switch contacts are open or closed in the normal state (see page 2) without pressure applied. Power is turned off for this test. The wires to the switch are disconnected. A continuity test is then performed (ohm meter) between the wiring terminals on the switch. If the switch is a normally open switch (see page 2) the continuity test should indicate no continuity - open. If the result of this test indicated the contacts were closed, the switch must be replaced. Likewise if a normally closed switch s contacts tested open in its normal state it would also have to be replaced. Note: gaining access to the switch and it s wiring terminals may involve removing the switch, opening a control box etc. THE SECOND AND THIRD PROCEDURES ARE PERFORMED WITH THE BLOWER RUNNING. Second Procedure is an operational test to determine if the switch contacts are open or closed while the blower is running and pressure is applied to the switch. The wires to the switch remain disconnected and a continuity test is performed as in the first procedure above. Ensure the wires ends do not touch/short to ground. Ensure the sensing tube is properly connected at both ends and test for continuity with the blower running at full speed. Note the condition of the switch contacts; whether open or closed. Normally open air pressure switches must close during operation and normally closed air pressure switches must remain closed throughout the heating cycle on A. O. Smith fan assisted water heaters. This information can usually be found in the sequence of operation section of the owner s manual and/or service manual for the product. Contact the A. O. Smith technical information center ( ) for more information. Normally open switches: If the air pressure switch being tested is a normally open switch, it must close it s contacts (activate) before ignition can occur. If the continuity test indicates a normally open switch s contacts have closed while the blower is running, the switch is operating correctly. If the continuity test indicates the switch contacts are remaining open while the blower is running the third pressure test procedure will have to be performed. This will determine if the switch is defective or if the switch contacts are failing to close because the pressure being sensed has not reached the activation point for the switch. This is covered on the next page. Normally closed switches: If the air pressure switch being tested is a normally closed switch, the switch contacts must remain closed throughout the heating cycle. If the continuity test indicates a normally closed switch s contacts remain closed while the blower is running, the switch is operating correctly. If the continuity test indicates the switch contacts are opening after the blower starts the third pressure test procedure will have to be performed. This will determine if the switch is defective or if the switch contacts are opening because the pressure being sensed has reached or exceeded the activation point. This will be covered on the next page. AHSA of 8
41 Air Pressure Switch Testing (cont) The pressure activation point for the air pressure switch below is " W. C. (inches water column) This is a negative pressure value in a vacuum. Blocked Vent Air Pressure Switch Residential Power Vent Model Blocked Vent Switch - Pressure Test Vertex Residential Power Vent Model Third Procedure is a pressure test and requires a digital manometer capable of reading positive and negative pressures. A good range of operation would be W.C. to W.C. (inches water column) with a resolution of 0.01 W.C. Recommend the UEI model EM-200 or Extech model dual pressure digital manometers, not shown here. To determine if an air pressure switch is operating properly you must know the pressure activation point for the switch and whether it activates on a rise or a fall in pressure. The activation point is a given pressure value and may be a positive or negative (in a vacuum) pressure. This information is often provided on the switch label (see image above). Whether the switch activates on a rise or fall in pressure is the type of switch action, this information is available here (page 7) for most current residential and commercial fan assisted water heaters. Contact the technical information center when the activation point and/or switch action are not known. Have the complete water heater Model, Serial, and Series number on hand before calling. Taking Air Pressure Readings: Disconnect the pressure sensing tube from the sensing port on the switch, leave the other end connected. Examine the sensing tube connection on the water heater, check for wear, leaks, kinks, or any kind of debris or condensate in the sensing tube, repair/replace as necessary. Connect a digital manometer to the pressure switch end of the sensing tube as shown above. Turn the power on and ensure a call for heat is active. When the blower starts and comes up to full speed, record the pressure reading. Normally Open Switches: Normally open air pressure switches must close their contacts after the blower is energized, the pressure reading taken must reach or exceed the activation point (pressure value) for the pressure switch being tested or the contacts will not close. Pressure reading taken DOES NOT reach activation pressure: DO NOT replace the air pressure switch if the contacts do not close during second procedure. The switch is not defective. IE: Residential power vent product - the pressure switch on these products is a normally open closes on a fall in pressure switch (see page 7). If the activation point for the switch is W.C. and the actual pressure reading taken was " W.C., the actual pressure has not reached the activation point. The switch contacts will not close until the pressure reaches or exceeds " W. C.. AHSA of 8
42 Blocked Exhaust Switch Pressure Test Cyclone - BTH 300/400 Models Blocked Exhaust Switch Pressure Test Cyclone - BTH Models Air Pressure Switch Testing Third Procedure - Normally Open Switches (cont): Pressure reading taken DOES NOT reach the activation pressure (cont): Ensure the sensing tube is connected securely and not blocked with any debris or condensate. Ensure the tube is not kinked or leaking. On residential power vent models check vent piping for excessive length or number of elbows, check for obstructions in the vent pipe. On Cyclone BTH models ensure the minimum vent pipe length requirement (7' BTH , 15' BTH 300/400) has been met. Ensure the blower wheel is clean on all models. This can become dirty over time or during construction on new water heaters and cause operational problems. Pressure reading taken DOES reach the activation pressure: If the test results for the second procedure indicated the normally open switch contacts did not close and the pressure reading taken during the third procedure indicated the pressure sensed by the switch did reach or exceed the activation point (pressure value) for the switch, the switch is defective and should be replaced. Normally Closed Switches: Current design residential power-vent/power direct-vent and commercial BTI/ BTN models are not equipped with normally closed air pressure switches. Cyclone BTH models are equipped with two normally closed air pressure switches; a blocked inlet and blocked exhaust switch (see pages 7 & 8). Normally closed switches should remain closed at all times unless there is an operational problem. Pressure reading taken DOES NOT reach the activation pressure: If the test results for the second procedure indicated a normally closed switches contacts were opening during blower operation AND the pressure reading taken DOES NOT reach or exceed the activation point (pressure value) for the switch, the switch is defective and should be replaced. Pressure reading taken DOES reach the activation pressure: If the test results for the second procedure indicated a normally closed switch contacts were opening during blower operation AND the pressure reading taken DOES reach or exceeds the activation point for the switch DO NOT replace the switch, it is not defective. Ensure the intake air or vent piping is not excessive and both are free of obstructions. Always check the owner s manual vent installation section for proper intake air and vent pipe installation requirements. AHSA of 8
43 Air Pressure Switch Types Contact States Normally Open = NO Normally Closed = NC Contact Actions Close on a rise in pressure Close on a fall in pressure Open on a rise in pressure Open on a fall in pressure Application Normal State Activated State Blocked Exhaust Air Pressure Switch Power-Vent & Power Direct Vent Residential Models Blower Prover Air Pressure Switch BTI/BTN Models Normally open contacts, close on a fall in pressure. Blocked Intake Air Pressure Switch Cyclone BTH Models Normally closed contacts, open on a fall in pressure. Blower Prover Air Pressure Switch Cyclone BTH Models Normally open contacts, close on a rise in pressure. Blocked Exhaust Air Pressure Switch Cyclone BTH Models Normally closed contacts, open on a rise in pressure. AHSA of 8
44 Air Pressure Switch Circuit Residential Power-Vent & Power-Direct-Vent Water Heaters 1 Blocked Exhaust Switch Normally Open Contacts Close on a Fall in Pressure Vent Temperature Limit Switch Normally Closed Contacts Open on a Rise in Temperature Molex Plug 6 Pin Plug 4 Air Pressure Switch Circuit Cyclone Water Heater 4 Blocked Inlet Switch Normally Closed Contacts Open on a Fall in Pressure Blocked Exhaust Switch Normally Closed Contacts Open on a Rise in Pressure CN6 Plug Control Board 6 Blower Prover Switch Normally Open Contacts Close on a Rise in Pressure AHSA of 8 Low Gas Pressure Switch Normally Open Contacts Close on a Rise in Pressure (BTH 120, 250, 300, 400 only)
45 Intelli-Vent Sequence of Operation
46
47
48
TB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION
1 2 3 4 5 Inadequate or no earth ground sensed by the Intelli-Vent control. Power supply to Intelli-Vent control has reversed polarity. Pressure switch circuit remaining closed for more than 5 seconds
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?
37E73A-903 & 906 INTELLI-VENT
37E73A-903 & 906 INTELLI-VENT Water Heater Thermostat Control Installation Instructions For Natural Gas Only Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table
New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex
Service Handbook Commercial / Residential gas water heater
Service Handbook Commercial / Residential gas water heater 500 Tennessee Waltz Parkway Ashland City, TN 37015 FOR MODELS: BTX 100, GDHE 50 SERIES 120 & 121 INSTALLATION CONSIDERATIONS - PRE SERVICE CHECKS
Fossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Gas-Fired, Residential Storage Type Water Heaters
Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. Gas-Fired, Residential Storage Type Water Heaters Most inspectors
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
COMMERCIAL GAS DRYER
COMMERCIAL GAS DRYER MODELS CGD8990XW0 4 12 Litho In U.S.A. (CMS) (psw) c 2012 WHIRLPOOL CORPORATION Part No. Rev. B TOP AND CONSOLE PARTS 2 TOP AND CONSOLE PARTS 1 Literature Parts W10184516 Installation
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
Commercial Gas Water Heater
Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service
Rinnai Tankless. Water Heater. Troubleshooting Manual
Rinnai Tankless Water Heater Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND
Honeywell Electronic Ignition Troubleshooting Tech Tip April 2007 The Honeywell S8610H Intermittent Pilot Module provides the ignition sequencing, pilot spark, pilot flame monitoring, Pilot Valve (PV)
Commercial Gas Water Heaters
POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600
SERVICE MANUAL. Flammable Vapor Ignition Resistant Water Heaters. Gas Water Heaters. Troubleshooting Guide and Instructions for Service
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html Flammable Vapor Ignition Resistant Water Heaters Gas Water Heaters SERVICE MANUAL Troubleshooting Guide and Instructions for Service
ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual
QUALITY STEAM SPECIALTIES SINCE ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual Section: C500 Bulletin: C500.40 Date: 06-26-01 Supersedes: New PRODUCT DESCRIPTION: The Clark-Reliance
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
Energy Saver SERVICE MANUAL COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER ATMOSPHERIC GAS WATER HEATERS
Energy Saver COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER ATMOSPHERIC GAS WATER HEATERS SERVICE MAUAL Troubleshooting Guide and Instructions for Service (To be performed OL by qualified service providers)
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type
SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
Thermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
Residential Gas and Electric Water Heaters
Residential Gas and Electric Water Heaters M O D E L S C O V E R E D Residential Gas Water Heaters that are atmospherically vented and use a thermocouple as their electrical source. Residential Electric
COMMERCIAL GAS DRYER
COMMERCIAL GAS DRYER MODELS CGM2941TQ0 CGM2941TQ1 07 08 Litho in U.S.A. (LT)(mek) c 2008 WHIRLPOOL CORPORATION Part No. Rev. B BULKHEAD PARTS (White) (White) 2 BULKHEAD PARTS 1 Literature Parts 8563800
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
G670 Intermittent Pilot Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
Tankless. Water Heater. Troubleshooting Manual
Tankless Water Heater Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
COMMERCIAL GAS DRYER
COMMERCIAL GAS DRYER MODELS CGM2751TQ0 (WHITE) CGM2751TQ1 (WHITE) 5 12 Litho in U.S.A. (CMS) (psw) c 2012 WHIRLPOOL CORPORATION Part No. W10119631 Rev. C TOP AND CONSOLE PARTS W10119631 2 TOP AND CONSOLE
The Bradford White. Save this manual for future reference. (To be performed ONLY by qualified service providers)
The Bradford White R (To be performed ONLY by qualified service providers) R U130T*FRN U130S*FRN U140T*FRN U1403T*FRN U1403S*FRN U1404T*FRN U1503*FRN U150L*FRN U1504S*FRN U430T*FRN U440T*FRN U4403S*FRN
ASK THE EXPERT: Burner Troubleshooting Information & Maintenance
ASK THE EXPERT: Burner Troubleshooting Information & Maintenance The burner is the heart of your BBQ. It is subject to a number of conditions that can cause damage, and lead to potential safety issues.
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM RELIANCE Has Everything Your Customers Need to Do the Job Right! Reliance Water Heater Company was founded in 1981 to provide a water heater
80UHG. Service Literature
Service Literature Corp. 9728 L12 Revised 01 2002 80UHG 80UHG series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with tubular heat exchangers formed
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting
Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html BURNER PROBLEM POSSBLE CAUSE(S) CORRECTVE ACTON WLL NOT GNTE 1. Pilot not tit Thermostat set too tow 3. Main burner line clogged Non-functioning
Applies to: Models F, B, FE, and BE FOR YOUR SAFETY
Form CP-F/B-GC (Version A.2) Obsoletes Form CP-F/B-GC (Version A) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE Model B Model F All gas conversion must be done by a qualified
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
Model 7586. Description / Applications. Intermittent Pilot Gas Ignition Control
PARTS & ACCESSORIES Model 7586 Intermittent Pilot Gas Ignition Control Description / Applications The Beckett GeniSys Intermittent Pilot Gas Ignition Control is a 24 Vac gas ignition and safety control.
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
Luna 3 Comfort Troubleshooting Guide June 2008
Luna 3 Comfort Troubleshooting Guide June 2008 For Technical Assistance Call: (800)461-4657 WARNING! THIS DOCUMENT IS INTENDED ONLY AS AN EDUCATIONAL TOOL This Troubleshooting Guide, and the instructions
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
Technical Guide 08/15/14
Technical Guide 08/15/14 1 Table of Contents Contact information.3 Identifying your system..4-8 Model Number Serial number location Parts of your fuel system..9-14 Fuel pump diagram Wire harness schematics
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483
Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483 Section 3 Table of Contents Page 3-2 General Information and Specification 3-3 Information About Electrical Connections 3-3 Description
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL
Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION
Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Commercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:
ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS: COMPONENTS/BOARD LAYOUT... 2 HOT WATER... 3 1 FLASH (GREEN DIAGSTIC LIGHT)... 4 2 FLASHES (GREEN DIAGSTIC LIGHT)... 5 3 FLASHES (GREEN DIAGSTIC LIGHT)...
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
G9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Please keep this manual for f uture reference.
GAS WATER/AGUA Congratulations! You've just purchased a new Marey Portable tankless water heater and will soon begin to enjoy the benefits of going tankless. Take the time to thoroughly read and understand
INSTANT HOT WATER RECIRCULATING SYSTEM
INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
RESIDENTIAL GAS AND ELECTRIC WATER HEATER SERVICE HANDBOOK TABLE OF CONTENTS
TABLE OF CONTENTS Page Introduction Terms... 1 Tools... 2 Residential Gas Water Heaters General Information... 3 Installation... 5 Operations and Servicing Control... 6 Burner... 7 Normal Operations...
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
ELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
Service Manual Models: ER152, ER202, ER252, ER302, and ER402
Models: ER152, ER202, ER252, ER302, and ER402 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual and the EnergyRite
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327