Operation manual and installation instructions. Solar charger SL45 SL60. Copyright 2010 Vetus n.v. Schiedam Holland

Similar documents
12 Volt 30 Amp Digital Solar Charge Controller

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

Solar Controller / Battery Charger User s Manual

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

SOLAR POWER - THE NEW WAY TO RV!

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

Solar charger controller User s Manual

BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES

If you accidentally get battery acid on your skin, flush it with lots of water

Manual. Solar Fountain Mobile Phone Charger

OUTPUT CABLE CONNECTIONS:

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Battery Power Inverters

S10I / S20I / S30I Solar Light Controller USER MANNUAL

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Mobile Data Power Model: MDP-25

TruPower-Portable-500W. Solar Starter kit

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Inverter / Charger Installation General Operations and AC and DC Connections

User Manual for CH-PFC76810

PSC-A5 Solar Charge Controller Manual

View Star series. Solar Charge Controller INSTRUCTION MANUAL

User s Manual Before using the inverter, you need to read and save the safety instructions.

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

4KVA/5KVA Parallel Installation Guide

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

HM-W536 Install Guide

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

SOLAR PV SYSTEM MAINTENANCE GUIDE

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

MULTI XS 4003 Battery charger

TIG INVERTER INSTRUCTION MANUAL

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

User Manual HomeGrid 3000 Solar Generator

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

MCR1900 Media Converter 19-Slot Chassis

Manual for Fire Suppression & Methane Detection System

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

How To Use A Power Supply Unit (Upu)

VLT Series 300 Watt True Sine Wave Inverter

SOLAR BOOST 2000E 25AMP 12VDC MAXIMUM POWER POINT TRACKING PHOTOVOLTAIC CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL

Charge Regulator SCR 12 Marine

Applied Electronics. Commercial Dimming System UPDATE NOTICE

BB800 Off-Grid Solar System

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

SNMP Web Management. User s Manual For SNMP Web Card/Box

Model 201 Wiegand Touchpad Reader Installation Guide

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Installation and Operation Guide for PD4000 Series Power Control Center

2 Installation Explanation

INSTALLATION & SERVICE MANUAL. Display Panel

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

TROUBLESHOOTING GUIDE

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

Switch Mode, Automatic, Lead Acid Battery Charger 3 Stage (IUoU)

GV-Boost Manual. 8A Input / W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Installation and operating instructions. Solar charge controller Solarix MPPT Z Z

Drayton Digistat +2RF/+3RF

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

ST Series POWER SUPPLIES USER INSTRUCTIONS

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

Thyristor-controlled power supplies and battery chargers

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Section III Schedule of Requirements TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS

AC-115 Compact Networked Single Door Controller. Installation and User Manual

GLOLAB Two Wire Stepper Motor Positioner

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

Industrial Solar Power PoE Switch

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

PDS-750-TR Touring Power Supply Operator s Manual

PART 1 - INTRODUCTION...

MIDNITE SOLAR AND SOLAR WASHINGTON

PUSH CV. Vi säljer och konsulterar Ledbelysning. Utebelysning Innebelysning Led-strip RGB Drivdon. SÄLJKONTOR Torstensviksvägen Frillesås

User s Manual AURORA 1.2K/2.2K

Home Solar Kit Owner s Manual. Model: HS

T7560A,B,C Digital Wall Module

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

Transcription:

Operation manual and installation instructions Solar charger SL45 SL60 Copyright 2010 Vetus n.v. Schiedam Holland

Contents 1 Description 4 1.1 Versions and Ratings 5 1.2 Operating Modes 5 1.3 Adjustability 6 1.4 General Use 7 1.5 Optional Available 8 2 Installation 9 2.1 General Information 9 2.2 Installation Overview 9 2.3 Control Terminal Connection 10 2.4 Installation Steps 13 2.4.1 Mounting 14 2.4.2 Solar Battery Charging DIP Switch Settings 15 2.4.3 Load Control DIP Switch Setting 18 2.4.4 Diversion Charge Control DIP Switch Setting 20 2.4.5 Battery Temperature Sensor (BTS) 20 2.4.6 System Wiring and Power-Up 21 2.4.7 Finish Installation 23 2.5 Communication with the Vetus Combi-Gamma 24 3 Front Cover Operation 26 3.1 LED Status Indicators 26 3.2 Charge Control or Diversion Control Mode Indications 27 3.3 Load Control Indicators 27 3.4 Equalization Mode Indication 28 3.5 Fault Mode Indication 29 3.6 LCD Meter Display 29 3.6.1 LCD Displays Flow 30 3.6.2 Fault Messages 31 4 Solar Battery Charging 32 4.1 PWM Battery Charging 32 4.1.1 Four Stages of Solar Charging 32 4.1.2 Battery Charging Notes 33 4.2 Standard Battery Charging Programs 34 4.3 Temperature Effects 35 4.3.1 Battery Temperature Sensor (BTS) 35 4.4 Equalization 36 4.4.1 Standard Equalization Programs 37 4.4.2 Typical Equalizations 38 4.4.3 When to Equalize 38 4.5 Float 38 2 090136.02 Solar charger SL45, SL60

5 Load Control 39 8.4 Nicad and NiFe Batteries 52 5.1 Inductive Loads (Motors) 39 5.2 General Load Control Notes 40 5.2.1 Inverters 40 5.2.2 Parallel Vetus Solar Chargers 40 5.2.3 Reverse Polarity 40 6 Diversion Charge Control 42 6.1 Diversion Charge Control 42 6.2 Diversion Current Ratings 42 6.3 Standard Diversion Battery Charging Programs 43 6.4 Selecting the Diversion Load 44 6.4.1 Suitable Loads for Diversion 44 6.4.2 Definition of Terms 44 6.4.3 Load Power Ratings 45 6.4.4 Maximum Diversion Load 45 6.4.5 Minimum Diversion Load 46 7 Trouble Shooting 48 8 Battery Information 50 8.1 Sealed Batteries 50 8.2 Flooded Batteries 51 8.3 L-16 Cells 52 Solar charger SL45, SL60 090136.02 3

1 Description The Vetus Solar Charger SL is a technically advanced solar system controller. There are three operating modes programmed into each Vetus Solar Charger SL. The manual describes solar battery charging, DC diversion charge control or DC Load control instructions are inserted where required. The manual will help you to become familiar with the Vetus Solar Charger SL s features and capabilities. This operation manual is applicable to the software version V1.05 and later version of the Vetus Solar Charger SL units. Some of these follow: Solid-state Pulse Width Modulated (PWM) charging process with four-stage control, temperature compensation, and manual or automatic equalization to maximizes system performance and increase battery life. Electric overload and short circuit protection with automatic and manual reset capability increase the reliability of unattended systems by eliminating blown fuses and tripped circuit breakers. Optional external battery temperature compensation (BTS) for automatic adjustment of charge set points. Over-temperature protection for the electronic circuitry when used in hot environment (over 80 ) LCD meter with easy to read mode/status messages. An 8-position DIP switch to set up the controller for its intended use. All major functions can be set with DIP switches. Rated for 12, 24, 48 volt systems, and 45 or 60 amps current. Eight standard charging or Load programs selected with DIP switches. Continuous self-testing with fault notification. LED indications and push button functions. Complies with EMC and LVD standards for CE marking. 4 090136.02 Solar charger SL45, SL60

1.1 Versions and Ratings There are two standard versions of Vetus Solar Charger SL controllers: SL60: Rated for maximum 60 amps continuous current (solar, load or diversion load) Rated for 12, 24, 48 V DC systems SL45: Rated for maximum 45 amps continuous current (solar, load or diversion load) Rated for 12, 24, 48 V DC systems 1.2 Operating Modes There are three distinct and independent operating modes programmed into each Vetus Solar Charger SL. Only one mode of operation can be selected for an individual Vetus Solar Charger SL. If a system requires a charging controller and a load controller, two Vetus Solar Charger SLs must be used. Solar Battery Charging The energy output of a solar array is used for recharging the system battery. The Vetus Solar Charger SL manages the charging process to be efficient and to maximize the life of the battery. Charging includes a bulk charging stage, PWM absorption, float and equalization. DC Load Control When set for DC load control, the Vetus Solar Charger SL powers loads from the battery, and protects the battery from over-discharge with a current compensated LVD (low voltage load disconnect). DC Diversion Charge Control In DC diversion mode, the Vetus Solar Charger SL will manage battery charging by diverting energy from the battery to a dedicated diversion load. The energy source is typically wind or hydro. Solar charger SL45, SL60 090136.02 5

1.3 Adjustability Eight DIP switches permit the following parameters to be adjusted at the installation site: DIP switch Solar battery charging (Diversion charge control) 1 (OFF) Battery charge control mode (Diversion charge control mode) 2 3 Select Battery Voltage OFF OFF 48V system ON OFF 24V system OFF ON 12V system 4~6 Standard battery charging programs 7 (OFF) Manual Equalization (ON) Auto Equalization 8 (OFF) Operating from Dip Switch 4~6 battery charging programs settings (ON) DIP switch VR1 and VR2 settings for user define battery charging programs Load control 1 (ON) Load control mode 2 3 Select Battery Voltage OFF OFF 48V system ON OFF 24V system OFF ON 12V system DIP switch Load control 4~6 Standard low voltage disconnects and reconnects 7 (OFF) Manual reconnect for Dip Switch 4~6 standard low voltage (ON) 8 (OFF) (ON) Auto reconnect for Dip Switch 4~6 standard low voltage Operating from Dip Switch 4~6 standard low voltage disconnects and reconnects VR1 and VR2 settings for user define low voltage disconnects and reconnects 6 090136.02 Solar charger SL45, SL60

1.4 General Use NOTE: This manual describes solar battery charging. Specific instructions for the DC load control and DC diversion charge control modes are provided as notes throughout this manual. The Vetus Solar Charger is suitable for a wide range of solar applications including homes, telecom and industrial power needs. The Vetus Solar Charger controllers are configured for negative ground systems. There are no parts in the controller s negative leg. The enclosure can be grounded using the ground terminal in the wiring compartment. The Vetus Solar Charger is protected from faults electronically with automatic recovery. There are no fuses or mechanical parts inside the Vetus Solar Charger SL to reset or change. Solar overloads up to 130% of rated current will be tapered down instead of disconnecting the solar. Over-temperature conditions will also taper the solar input to lower levels to avoid a disconnect. Any number of Vetus Solar Chargers can be connected in parallel to increase solar charging current. Vetus Solar Chargers can be paralleled ONLY in the battery charging mode. DO NOT parallel Vetus Solar Chargers in the load mode, as this can damage the controller or load. The Vetus Solar Charger is rated for indoor use. The controller is protected by conformal coated circuit boards, stainless steel hardware, anodized aluminium, and a powder coated enclosure, but it is not rated for corrosive environments or water entry. The construction of the Vetus Solar Charger is 100% solid state. Battery charging is by a series PWM constant current charging, with bulk charging, PWM absorption, float and equalization stages. The Vetus Solar Charger will accurately measure time over long intervals to manage events such as automatic equalizations or battery service notification. Day and night conditions are detected by the Vetus Solar Charger, and no blocking diodes are used in the power path. LED s, a push button, and LCD meters provide both status information and various manual operations. Solar charger SL45, SL60 090136.02 7

1.5 Optional Available Three optional components can be added to the standard Vetus Solar Charger controller at any time. Battery Temperature Sensor (BTS) If the temperature of the system battery varies more than 5 C during the year, temperature compensated charging should be considered. Because the battery s chemical reactions change with temperature, it can be important to adjust charging to account for the temperature effects. The BTS will measure the battery temperature, and the Vetus Solar Charger uses this input to adjust the charging as required. The battery charging will be corrected for temperature as follows: Charger Set point Temperature Compensation Chart Battery Type System Voltage 12VDC 24VDC 48VDC Lead Acid 30mV/ºC 60mV/ºC 120mV/ºC Nicad 20mV/ºC 40mV/ºC 80mV/ºC The BTS should be used only for battery charging and diversion control. Do not use the BTS for load control. The charging parameters that are adjusted for temperature include: PWM regulation Equalization Float High Voltage Disconnect RJ-45 Communication Cable RJ-45 Communication Cable is used to connect the Vetus Solar Chargers to the Vetus Combi-Gamma Inverter/Charger. The connection of the Vetus Combi-Gamma and Vetus Solar Chargers can become a power management control system of standalone PV charger. When connecting a Vetus Combi-Gamma to Vetus Solar Chargers in parallel, the maximum units can go up to 10 Vetus Solar Chargers. The optional RJ-45 Communication Cables can be supplied in the following length. RJ-45-03 (3 Meter long Communication Cable) RJ-45-05 (5 Meter long Communication Cable) RJ-45-10 (10 Meter long Communication Cable) 8 090136.02 Solar charger SL45, SL60

2 Installation The installation instructions describe solar battery charging. Specific instructions for the load control and diversion modes are provided as notes. 2.1 General Information The mounting location is important to the performance and operating life of the controller. The environment must be dry and protected as noted below. The controller may be installed in a ventilated enclosure with sealed batteries, but never in a sealed battery enclosure or with vented batteries. If the solar array exceeds the current rating of the controller, multiple Vetus Solar Chargers can be installed in parallel. Additional parallel controllers can also be added in the future. The load controllers cannot be used in parallel. If solar charging and load control are both required, two separate controllers must be used. 2.2 Installation Overview The installation is straightforward, but it is important that each step is done correctly and safely. A mistake can lead to dangerous voltage and current levels. Be sure to carefully follow each instruction in Section 2.3 and observe all cautions and warnings. The following diagrams provide an overview of the connections and the proper order: Di p Switches VR2 VR1 BCD Switch IN OUT Communication Port Battery Positive + PV+ / Load + PV / Load Battery Negative Earth BTS BTS + Solar charger SL45, SL60 090136.02 9

2.3 Control Terminal Connection Name Battery + PV+ / Load + PV /Load Battery Earth Dip Switch 1 Dip Switch 2, 3 Dip Switch 4, 5, 6 Dip Switch 7 Dip Switch 8 VR1, VR2 BCD Switch 0 BCD 1~A BCD B~F Communication IN Communication OUT BTS+ BTS Battery cable Positive connection Description Connecting terminal for Solar Array or DC Load Positive Connecting terminal for Solar Array or DC Load Negative Battery cable Negative connection Connecting terminal for Ground ON or OFF to choose battery charge control mode or load control mode Selection of battery voltage for 12V or 24V or 48V system Battery charge control mode: Battery charging algorithm Load control mode: Load control disconnect/reconnect algorithm Battery charge control mode: Auto / Manual Equalization Load control mode: Auto / Manual Reconnect ON: Potentiometer of VR1, VR2 setting range OFF: Dip switch 4~6 setting range User define battery charging programs or user define standard low voltage disconnect and reconnect Vetus Solar Charger unit is operating alone. *When the BCD Switch is not placed at 0 and the fault message of Alarm: CPF01 Wait for Combi will be displayed if the Vetus Solar Charger unit is not communicating with Vetus Combi-Gamma 1st~10th Vetus Solar Charger units are communicating with Vetus Combi-Gamma They are operating as the 10th Vetus Solar Charger unit Communication port for Vetus Combi-Gamma Communication port for the next Vetus Solar Charger unit Connecting terminal for Battery Temperature Sensor Positive Connecting terminal for Battery Temperature Sensor Negative 10 090136.02 Solar charger SL45, SL60

BAT+ PV+/ LOAD+ GND GND DC Load or Solar Array Ground BATTERY BTS Installation wiring for solar charging or DC load control Solar charging or DC load control: Step 1: Open the access cover Step 2: Mount the Vetus Solar Charger using the enclosed template. Step 3: Adjust the 8 switches in the DIP switch. Each switch must be in the correct position. Step 4: Attach the BTS if battery charging will be temperature compensated (not for load control). Step 5: Connect the battery power wires to the Vetus Solar Charger. Then connect the solar array wires (or DC load wires). Step 6: Close the cover. Step 4 is optional. Solar charger SL45, SL60 090136.02 11

BAT+ PV+/ LOAD+ GND GND Hydro Wind Solar Ground BTS DIVERSION LOAD BATTERY Installation wiring for DC diversion charge control DC diversion charge control: Step 1: Open the access cover Step 2: Mount the Vetus Solar Charger using the enclosed template. Step 3: Adjust the 8 switches in the DIP switch. Each switch must be in the correct position. Step 4: Attach the BTS if battery charging will be temperature compensated Step 5: Connect the battery power wires to the Vetus Solar Charger. Then connect the diversion load wires. Step 6: Close the cover. Step 4 is optional. 12 090136.02 Solar charger SL45, SL60

2.4 Installation Steps The Vetus Solar Charger controller must be installed properly and in accordance with the local and national electrical codes. It is also important that the installation be done safely, correctly and completely to realize all the benefits that the Vetus Solar Charger can provide for your solar system. Before starting the installation, review these safety notes: Do not exceed a battery voltage of 48V (nominal). Do not use a battery less than 12V. Do not connect a solar input greater than a nominal 48V array for battery charging. Never exceed a VOC (open-circuit voltage) of 140V. Charge only 12, 24, or 48 volt lead-acid batteries when using the standard battery charging programs or NI-CAD batteries when DIP switch number 4~6 is ON position in the Vetus Solar Charger. Verify the nominal charging voltage is the same as the nominal battery voltage. Do not install a Vetus Solar Charger in a sealed compartment with batteries. Never open the Vetus Solar Charger access cover unless both the solar and battery power has been disconnected. Never allow the solar array to be connected to the Vetus Solar Charger with the battery disconnected. This can be a dangerous condition with high open-circuit solar voltages present at the terminals. Solar charger SL45, SL60 090136.02 13

2.4.1 Mounting Unit: mm (inches) 5 (3/ 16 ) 30.5 (1 13 /64 ) 131 (5 5/32 ) 9.5 (3/8 ) 10 ( 3 / 8 ) 185 (7 9/32 ) 265 (10 7/16 ) 14 ( 9 /16 ) 94 (3 45/ 64 ) 127 (5 ) Mounting Dimensions Locate the Vetus Solar Charger on a wall protected from direct sun, high temperatures, and water. Do not install in a confined area where battery gasses can accumulate. When mounting the Vetus Solar Charger, make sure the air flow around the controller and heat sink is not obstructed. There should be open space above and below the heat sink, and at least 75 mm (3 inches) clearance around the heat sink to allow free air flow for cooling. Before starting the installation, place the Vetus Solar Charger on the wall where it will be mounted and determine where the wires will enter the controller. 14 090136.02 Solar charger SL45, SL60

2.4.2 Solar Battery Charging DIP Switch Settings The 8 DIP switches are located on the right of the Earth terminal. Each switch is numbered. The solar battery charging functions that can be adjusted with the DIP switches follow: ON ON D IP OFF 1 2 3 4 5 6 7 8 Control Mode (1) Battery Charging (diversion charge control) System Voltage (2,3) Battery Charging algorithm (4,5,6) Manual/Auto Equalization (7) User Define Charging algorithm (8) DIP Switch Functions As shown in the diagram, all the positions are in the OFF position except switch number 3 and 7 which are in the ON position. NOTE: The DIP switches should be changed only when there is no power to the controller. Turn off disconnect switches and remove all power to the controller before changing a DIP switch. A fault will be indicated if a switch is changed while the controller is powered. CAUTION 1: The Vetus Solar Charger is shipped with all the switches in the OFF position. Each switch position must be confirmed during installation. A wrong setting could cause damage to the battery or other system components. CAUTION 2: To configure your Vetus Solar Charger for the battery charging and control you require, follow the DIP switch adjustments described below. Before changing any switch, make sure the BCD switch is placed at number 0 for the Vetus Solar Charger settings. To change a switch from OFF to ON, slide the switch up towards the top of the controller. Make sure each switch is fully in the ON or OFF position. Solar charger SL45, SL60 090136.02 15

DIP Switch Number 1-Control Mode: Solar battery charging Switch 1 ON OFF Control Mode Load control mode Solar charging mode (Diversion charge control mode) For the solar battery charging control mode, leave the DIP switch in the OFF position. DIP Switch Number 2, 3-System voltage Switch 2 Switch 3 System Voltage OFF OFF 48V system ON OFF 24V system OFF ON 12V system DIP Switch Number 4, 5, 6-Battery charging algorithm DIPSW-4 DIP SW-5 DIP SW-6 Bulk voltage Float voltage Equalize Voltage Equalize Time (hours) Equalize Interval (days) OFF OFF OFF 14.0V 13.4V None - - OFF OFF ON 14.1V 13.4V 14.2V 1 28 OFF ON OFF 14.3V 13.4V 14.4V 2 28 OFF ON ON 14.4V 13.4V 15.1V 3 28 ON OFF OFF 14.6V 13.4V 15.3V 3 28 ON OFF ON 14.8V 13.4V 15.3V 3 28 ON ON OFF 15.0V 13.4V 15.3V 3 14 ON ON ON 16.0V 14.5V - - - Select one of the 7 standard battery charging algorithms, or select NiCad to determine the charging of the battery. The above setting voltage value is in the condition of 12V system. The voltage will be twice of above values in the 24V system and it will be four times of above values in the 48V system. Refer to section 8.0 of the manual for battery charging information. The 7 standard charging algorithms above are described in section 4.2-standard battery charging programs. 16 090136.02 Solar charger SL45, SL60

DIP switch number 7- Battery Equalization Switch 7 ON OFF Battery Equalization Auto Equalization Manual Equalization In the Auto Equalization Mode (Switch number 7 ON), the Vetus Solar Charger controller can automatically triggering of the equalization process. When automatic has been selected, an equalization charge will occur at set voltage and time (hours and days). During the equalization process, the status LED indicates equalization (Equalization is not recommended for NiCad batteries and is disabled). The equalization process will continue until the voltage has been held above the bulk setting for a cumulative period of set hours as shown above. This might take several days on larger system with big batteries and small solar arrays. The battery voltage only needs to exceed the bulk setting for the timer to start counting-the voltage may not reach the equalization voltage setting. To manually stop the equalization process, press the reset push button and the status LED will stop, if the equalization process was shorter than one hour, the controller will continue with a bulk charge cycle and then hold the battery at the bulk setting for one hour (the absorption voltage) before returning to the float setting. Once a manual equalization has been triggered, the period to the next automatic equalization will be restarted. In the Manual Equalization Mode (Switch number 7 OFF), equalization will occur only when manually started with the push button. The equalization status LED indicator will begin to equalization enabled. The equalization process will continue until the batteries have been held at or above the set Equalize Voltage for set Equalize Time of accumulated time. During the equalization process, the battery voltage will be limited to the set Equalize Voltage setting. Once the battery voltage has been at or above the set Equalize Voltage for a cumulative period of set Equalize Time, the Vetus Solar Charger will return to the float stage of the charge process. To stop the equalization process, press the reset push button, the status LED will stop. If the equalization process was shorter than one hour, the controller will continue with a bulk charge cycle and hold the battery at bulk setting for one hour (the absorption stage) before returning to the float setting. DIP switch number 8-User define battery select Switch 8 ON OFF Charge Control algorithm User define (VR1, VR2) Dip Switch 4~6 selection The battery voltage setting range of VR2 BULK Voltage potentiometer is 13.0V~15.0V The battery voltage setting range of VR1 FLOAT Voltage potentiometer is 12.5V~14.5V Solar charger SL45, SL60 090136.02 17

The above setting voltage value is in the condition of 12V system. The voltage will be twice of above values in the 24V system and it will be four times of above values in the 48V system. The LCD Meter display will show the voltage setting value of VR2 and VR1 and the user can adjust those values directly. 2.4.3 Load Control DIP Switch Setting The Load Control functions that can be adjusted with the DIP switches follow: ON ON DIP OFF 1 2 3 4 5 6 7 8 Control Mode (1) DC Load Control System Voltage (2,3) LVD / LVR (4,5,6) Auto / Manual LVR (7) User Define LVD/LVR (8) LVD: (Low Voltage Disconnect) LVR: (Low Voltage Reconnect) Load Control DIP Switch Functions As shown in the diagram, all the positions are in the OFF position except switch number 1, which is in the ON position. NOTE: The DIP switches should be changed only when there is no power to the controller. Turn off disconnect switches and remove power to the controller before changing a DIP switch. A fault will be indicated if a switch is changed with the controller powered. CAUTION 1: The Vetus Solar Charger is shipped with all the switches in the OFF position. Each switch position must be confirmed during installation. A wrong setting could cause damage to the load or other system components. CAUTION 2: To configure your Vetus Solar Charger for the Load Control you require, follow the DIP switch adjustments described below. Before changing any switch, make sure the BCD switch is placed at number 0 for the Vetus Solar Charger settings. To change a switch from OFF to ON, slide the switch up toward the top of the controller. Make sure each switch is fully in the ON or OFF position. 18 090136.02 Solar charger SL45, SL60

DIP Switch Number 1-Control Mode: Load Control Switch 1 ON OFF Control Mode Load control mode Solar charging mode or the load control mode, move the DIP switch to the ON position. DIP Switch Number 2, 3-System Voltage Switch 2 Switch 3 System Voltage OFF OFF 48 V system ON OFF 24 V system OFF ON 12 V system DIP Switch Number 4, 5, 6-Load Control Algorithm DIPSW -4 DIP SW-5 DIP SW-6 LVR LVD 12V 24V 48V 12V 24V 48V OFF OFF OFF 12.6V 25.2V 50.4V 11.1V 22.2V 44.4V OFF OFF ON 12.8V 25.6V 51.2V 11.3V 22.6V 45.2V OFF ON OFF 13.0V 26.0V 52.0V 11.5V 23.0V 46.0V OFF ON ON 13.2V 26.4V 52.8V 11.7V 23.4V 46.8V ON OFF OFF 13.4V 26.8V 53.6V 11.9V 23.8V 47.6V ON OFF ON 13.6V 27.2V 54.4V 12.1V 24.2V 48.4V ON ON OFF 13.8V 27.6V 55.8V 12.3V 24.6V 49.2V ON ON ON 12.0V 24.0V 48.0V 10.5V 21.0V 42.0V Select 1 of the 8 standard load control algorithms. Dip Switch Number 7-Auto Reconnect or Disconnect standard low voltage Switch 7 ON OFF Selection Auto Reconnect after low voltage returning to Dip Switch 4~6 standard LVR setting Manual Reconnect after low voltage disconnect (LVD) Solar charger SL45, SL60 090136.02 19

Manual reconnect of the loads is allowed when voltage has not exceeded the LVR setting. To reconnect the loads, press the reset button on the front panel of the unit. If the voltage is below the LVR level, the DC load can be reconnected from approximately 6 minutes. Multiple reconnects are allowed, but the on time duration will vary with battery voltage. (Approximately 5 seconds when the battery voltage is under 10V). When Dip Switch 7 is ON position, it allows the controller to be set for Auto reconnect of the DC load when the voltage exceeds the LVR setting. DIP switch number 8-User define LVR, LVD Switch 8 ON OFF LVR range set by VR2: LVD range set by VR1: Load Control algorithm User define (VR1, VR2) Dip Switch 4~6 selection 12.0V~14.0V (12V system) 24.0V~28.0V (24V system) 48.0V~56.0V (48V system) 10.5V~12.5V (12V system) 21.0V~25.0V (24V system) 42.0V~50.0V (48V system) The LED Meter display will show the voltage setting value of LVR (VR2) and LVD (VR1) and the user can adjust those values directly. 2.4.4 Diversion Charge Control DIP Switch Setting Diversion charge control DIP switch settings are exactly the same as solar battery charging DIP switch setting which can be referred to 2.4.2 description. 2.4.5 Battery Temperature Sensor (BTS) For solar battery charging and diversion load control, a Battery Temperature Sensor (BTS) is recommended for effective temperature compensated charging. This Battery Temperature Sensor should not be installed for DC load control. The BTS is supplied with 10 meters (33 ft) of 0.34 mm 2 (22 AWG) cable. There is +/- polarity so pay attention to connecting the polarity. Reverse of the polarity may damage the BTS. 20 090136.02 Solar charger SL45, SL60

2.4.6 System Wiring and Power-Up Wire Size: The five large power terminals are sized for 35-2.5 mm2 (2-14 AWG) wire. The terminals are rated for copper and aluminium conductors. Good system design generally requires large conductor wires for the solar and battery connections that limit voltage drop losses to 3% or less. The following table provides the maximum wire length (1-way distance / 2-wire pair) or connecting the battery, solar array or load to the Vetus Solar Charger with a maximum 3% voltage drop. Wire size 60 A 45 A Wire size 60 A 45 A 95 mm 2 12,86 m 17,15 m (3/0 AWG) (42.2 ft.) (56.3 ft.) 70 mm 2 10,19 m 13,58 m (2/0 AWG) (33.4 ft.) (44.6 ft.) 50 mm 2 8,10 m 10,80 m (1/0 AWG) (26.6 ft.) (35.4 ft.) 35 mm 2 5,12 m 6,83 m (2 AWG) (16.8 ft.) (22.4 ft.) 25 mm 2 3,21 m 4,27 m (4 AWG) (10.5 ft.) (14.0 ft.) 16 mm 2 2,02 m 2,69 m (6 AWG) (6.6 ft.) (8.8 ft.) 10 mm 2 1,27 m 1,70 m (8 AWG) (4.2 ft.) (5.6 ft.) 6 mm 2 1,06 m (10 AWG) (3.5 ft.) Maximum 1-Way Wire Length (12 Volts) Notes: The specified wire length is for a pair of conductors from the solar, load or battery source to the controller (1-way distance). Figures are in meters (m) and feet (ft). For 24 volt systems, multiply the 1-way length in the table by 2. For 48 volt systems, multiply the 1-way length in the table by 4. Ground Connection: Use the grounding terminal in the wiring compartment to connect a copper wire to an earth ground or similar grounding point. The grounding terminal is identified by the ground symbol shown below that is stamped into the enclosure: Ground symbol Solar charger SL45, SL60 090136.02 21

The minimum size of the copper grounding wire: Vetus Solar Charger-45A (SL45) 6 mm2 (10 AWG) Vetus Solar Charger-60A (SL60) 10 mm2 ( 8 AWG) Connect the Power Wires: First, confirm that the DIP switch #1 is correct for the operating mode intended. Di p Switches VR2 VR1 BCD Switch IN OUT Communication Port Battery Positive + PV+ / Load + PV / Load Battery Negative Earth BTS BTS + CAUTION: The solar PV array can produce open-circuit voltages over 100 Vdc when in sunlight. Verify that the solar input breaker has been opened (disconnected) before installing the system wires (if the controller is in the solar charging mode). Using the diagram on the previous pages, connect the four power conductors in the following steps: 1. Confirm that the input and output disconnect switches are both turned off before connecting the power wires to the controller. There are no disconnect switches inside the Vetus Solar Charger. 2. Pull the wires into the wiring compartment. The Battery Temperature Sensor (BTS) wires can be inside the conduit with the power conductors. 3. Connect the Battery + (positive) wire to the Battery + terminal. 4. Connect the Battery (negative) wire to the Battery terminal. 5. Connect the Solar + wire (positive) to the Solar + terminal. (or Load + / Diversion +) 22 090136.02 Solar charger SL45, SL60

6. Connect the Solar (negative) wire to the Solar terminal. (or Load / Diversion ) The CE certification requires that the battery conductors and BTS wires shall not be accessible without the use of a tool and are protected in the battery compartment. Do not bend the power wires up toward the access cover. These large wires can damage the meter assembly when the access cover is attached to the controller. Torque each of the five power terminals to 6 Nm (50 in-lbs). Power-Up Confirm that the solar (or load) and battery polarities are correct. Turn the battery disconnect on first. Observe the LED s and LCD meter to confirm a successful start-up. Note that a battery must be connected to the Vetus Solar Charger to start and operate the controller. The controller will not operate from a solar input only. Turn the solar (or load) disconnect on. 2.4.7 Finish Installation Inspect for tools and loose wires that may have been left inside the enclosure. Check the power conductors to make sure they are located in the lower part of the wiring compartment and will not interfere with the cover and the LCD meter assembly. NOTE: If the power conductors are bent upwards and touch the LCD meter assembly, pressing the cover down on the wires can damage the meter. Carefully place the cover back on the controller and install the one cover screw. Closely observe the system behaviour and battery charging for 2 to 4 weeks to confirm the installation is correct and the system is operating as expected. Solar charger SL45, SL60 090136.02 23

2.5 Communication with the Vetus Combi-Gamma Vetus Solar Charger Series can not only operate alone when the BCD Switch is placed at 0 but also communicate with Vetus Combi-Gamma up to 10 units together when BCD Switch is placed at 1~A. The example of how to wire 1 unit of the Vetus Solar Charger and how to wire 2~10 units to Vetus Combi-Gamma is demonstrated in the following. The Wiring of 1 Unit of Vetus Solar Charger to Communicate with Vetus Combi-Gamma COMBI - GAMMA PORT C (EXT) AC INPUT BREAKER PORT A (IN) PORT B (OUT) REMOTE 1 V-SENS BTS CHARGE + - + - + - RY1 RY2 RY3 A B C A B C A B C VETUS SOLAR CHARGER SL SOLAR PANEL BAT+ PV+A GND GND IN OUT RJ-45 Cable BATTERY 24 090136.02 Solar charger SL45, SL60

The Wiring of 2~10 units of Vetus Solar Charger to Communicate with Vetus Combi-Gamma COMBI - GAMMA PORT C (EXT) AC INPUT BREAKER PORT A (IN) PORT B (OUT) REMOTE 1 V-SENS BTS CHARGE + - + - + - RY1 RY2 RY3 A B C A B C A B C VETUS SOLAR CHARGER SL SOLAR PANEL BAT+ PV+A GND GND IN OUT RJ-45 Cable 2 BATTERY VETUS SOLAR CHARGER SL SOLAR PANEL BAT+ PV+A GND GND IN OUT RJ-45 Cable 3 VETUS SOLAR CHARGER SL SOLAR PANEL BAT+ PV+A GND GND RJ-45 Cable IN OUT Solar charger SL45, SL60 090136.02 25

3 Front Cover Operation There are 4 LEDs, 1 LCD Meter of 16 x 2 characters and 2 push buttons on Vetus Solar Charger front cover. The details are described as follows: Vetus Solar Charger-60 A Unit Vetus Solar Charger-60 A Display Panel 3.1 LED Status Indicators Four LED indicate operating status of the controller. When the controller is in Charge Control Mode (or Diversion Charge Control Mode), the charge mode (green) LED will blink. When in Load Control Mode, the Load Control Mode (red) LED will blink. When battery equalization is in process, the Equalization (orange) LED is blinking. A red LED solid or blinking indicates a fault condition. 26 090136.02 Solar charger SL45, SL60

3.2 Charge Control or Diversion Control Mode Indications Charge Mode LED Solid Green: The battery is being charged in the FLOAT stage. The status LED remains ON solid unless the batteries drop below the float voltage setting for an accumulative period of one hour. This allows the user to confirm that the system reached the float stage during the charging process when checked at the end of the day. Reaching the float stage frequently is a good indication of proper system operation and will maximize battery life and performance. Charge Mode LED Blinking Green: The controller is CHARGE CONTROL or DIVERSION CONTROL Mode and the battery is not fully charged. As the battery voltage approaches the BULK setting, the status LED will blink green several times (up to five) and then pause, indicating the battery voltage is approaching the BULK setting and provides an indication of the battery condition. Refer to the table 1 to determine the battery voltage. NOTE: A single green flash indicates the battery is below the bulk voltage setting. It does NOT indicate the batteries are charging. LED Status Always ON Battery Voltage (Using LED Status Indicator) Green LED (Charge/Diversion Mode) Battery at FLOAT setting 5 Blinks Battery at BULK setting Bulk Setting Minus (-) 4 Blinks 0.25 VDC 0.50 VDC 1.00 VDC 3 Blinks 0.50 VDC 1.00 VDC 2.00 VDC 2 Blinks 0.75 VDC 1.50 VDC 3.00 VDC 1 Blinks > 0.75 VDC Below Bulk > 1.50 VDC Below Bulk > 3.00 VDC Below Bulk DC Voltage 12 Volts 24 Volts 48 Volts 3.3 Load Control Indicators Load Control Mode LED Solid Red: The controller is in DC Load Control Mode and the battery voltage has reached the Low Voltage Disconnect (LVD) setting. After a 6-minute delay, DC loads will be disconnected unless the user reduces the lad to a point that the battery voltage exceeds the LVD setting. Solar charger SL45, SL60 090136.02 27

Load Control Mode LED Blinking Red: As battery voltage approaches the LVD setting, the LED will blink red several times (up to five) and then pause providing an indication of battery voltage. Refer to Table 2 to determine the battery voltage. LED Status Always ON Battery Voltage (Using LED Status Indicator) Red LED (Load Control Mode) Battery at LVD setting (for 6 minute=lvd) 5 Blinks >0.15 Above LVD >0.3 Above LVD >0.45 Above LVD LVD Setting Plus (+) 0,15 VDC 0,30 VDC 0,45 VDC 4 Blinks 0.15 VDC 0.30 VDC 0.45 VDC 3 Blinks 0.30 VDC 0.60 VDC 0.90 VDC 2 Blinks 0.45 VDC 0.90 VDC 1.35 VDC 1 Blinks > 0.45 VDC Above LVD > 0.90 VDC Above LVD > 1.35 VDC Above LVD DC Voltage 12 Volts 24 Volts 48 Volts Table 2 Battery Voltage LED Indication (Load Control Mode) Load Control Mode LED Slow Blinking Red: The controller is in the DC Load Control Mode and has disconnected the loads due to reaching the LVD setting. The user can press the reset pushbutton for a maximum 6-minute grace period when Dip Switch 7 is in OFF position or can wait until the voltage rise above the low voltage Reconnect (LVR) setting to allow an automatic reset to occur when Dip Switch 7 is in ON position. 3.4 Equalization Mode Indication Equalization LED Blinking Orange: The controller is in the Equalization Mode. It will automatically stop the equalization process after accumulating setting Equalize Time of operation at Equalize Voltage above the BULK setting. The user can stop the equalization process at any time by pressing the reset push button until the status LED stops. 28 090136.02 Solar charger SL45, SL60

3.5 Fault Mode Indication Solid Red: The controller detects an over-current or an over-temperature condition and the load is disconnected. The controller will try to automatically restart the load after a 10 second delay. If the controller will not restart, turn off all loads and press the reset push button. If it then restarts, the load may be too large. A delay up to five seconds may occur before the controller attempts to restart after pressing the reset push button. The data exchange between CPU and the display panel can be detected a fault by the controller by showing alarm CPF00. When the controller is connected to the Vetus Combi-Gamma, BCD switch position should not be placed at 0 for the communication. Blinking Red: In DC Load Control Mode, the controller is in the status of battery low voltage disconnect. Details of the fault messages could be referred to 3.6.2 Fault Messages. 3.6 LCD Meter Display This display include a two-line, 32-characters LCD and Four status LED indicator only. The LCD provides the following information: Solar PV Array or DC Load press-through current: 0~80 amps DC Battery Voltage: 4 to 80 Volts DC Watts: 0 to 3600 Watts (Volts time Amps) Amp-hours: 0 to 655536Ah; can be reset to 0 Totalizing amp-hours: 0 to 65536 Ah; reset to 0 when power is disconnected Control mode and battery charging status Display of BULK and FLOAT voltage setting value Display of Equalization Voltage, Equalization Time and Equalization Interval Display of heatsink temperature and BTS temperature Fault Messages Solar charger SL45, SL60 090136.02 29

3.6.1 LCD Displays Flow The following chart shows clearly the display flow in the charger/diversion Control Mode and in the Load Control Mode. Charge / Diversion control Mode Display Flow Amp 0.0 Watts 0.0 PUSH: Display Select Amp-Hours 0 Ah PUSH: Display Select Total Amp-Hours 0 Ah PUSH: Display Select BatV 12.0 Amp 0.0 Load Control Mode Display Flow Watts 0.0 PUSH: Display Select Amp-Hours 0 Ah PUSH: Display Select Total Amp-Hours 0 Ah PUSH: Display Select BatV 12.0 Mode : Charger State : BULK Mode : Load State : connect PUSH: Display Select PUSH: Display Select Bulk 14.0V Float 13.4V PUSH: Display Select PUSH: Display Select LVR 12.6V LVD 11.1V PUSH: Display Select EQUEQU-T 14.2V 1hrs CYCLE 28day PUSH: Display Select PUSH: Display Select Heatsink 25 º C BTS 25 º C Heatsink 25 º C BTS 25 º C 30 090136.02 Solar charger SL45, SL60

3.6.2 Fault Messages The LCD displays might have the follo-wing fault messages when SunStar stops operating. Refer to their description and causes listed as below in order to remove the faults. Display Description Cause Details Alarm : OC Over Current Alarm : OT Over Temperature Alarm : LVD Load Disconnect Alarm : CPF00 Link Maste Err Alarm : CPF01 Wait for Combi Over Current Heatsink Over Temperature Battery Low Voltage Disconnect Display Panel Error Waiting for Combi- Gamma Communication The current exceeds 150% of rated current. Heatsink temperature exceeds 90ºC In Load Control Mode, battery voltage is lower than the setting value for 6 minutes. The CPU is not able to exchange data with the display panel. When BCD switch is placed at either 1~A, Vetus Solar Charger Sl is waiting for the communication with Combi-Gamma Solar charger SL45, SL60 090136.02 31

4 4.1 Solar Battery Charging PWM Battery Charging PWM (Pulse Width Modulation) battery charging is the most efficient and effective method for recharging a battery in a solar system. Selecting the best method for charging your battery together with a good maintenance program will ensure a healthy battery and long service life. Although the Vetus Solar Charger s battery charging is fully automatic, the following information is important to know for getting the best performance from your Vetus Solar Charger controller and battery. 4.1.1 Four Stages of Solar Charging 1. Bulk Charging: In this stage, the battery will accept all the current provided by the solar system. 2. PWM Absorption: When the battery reaches the regulation voltage, the PWM begins to hold the voltage constant. This is to avoid over-heating and over-gassing the battery. The current will taper down to safe levels as the battery becomes more fully charged. 3. Equalization: Many batteries benefit from a periodic boost charge to stir the electrolyte, level the cell voltages, and complete the chemical reactions. 4. Float: When the battery is fully recharged VOLTAGE NIGHT 1 BULK CHARGING 2 PWM ABSORPTION 3 EQUALIZE 4 FLOAT NIGHT TIME Figure 4.1.1 Solar Charging Stages 32 090136.02 Solar charger SL45, SL60

4.1.2 Battery Charging Notes The Vetus Solar Charger manages many different charging conditions and system configurations. Some useful functions to know follow below. Solar Overload: Enhanced radiation or edge of cloud effect conditions can generate more current than the controller s rating. The Vetus Solar Charger will reduce this overload up to 130% of rated current by regulating the current to safe levels. If the current from the solar array exceeds 150%, the controller will interrupt charging. Battery Temperature Compensation: All charging set points are based on 25 C (77 F). If the battery temperature varies by 5 C, the charging will change by 0.15 volts for a 12 volt battery. This is a substantial change in the charging of the battery, and a remote temperature sensor (BTS) is recommended to adjust charging to the actual battery temperature. Day-Night Detection: The Vetus Solar Charger will automatically detect day and night conditions. Any functions that require measuring time or starting at dawn, for example, will be automatic. Battery Types: The Vetus Solar Charger s standard battery charging programs are suitable for a wide range of lead-acid battery types. These standard programs are reviewed in the following Section 4.2. A general review of battery types and their charging needs is provided in Section 8.0. Solar charger SL45, SL60 090136.02 33

4.2 Standard Battery Charging Programs The Vetus Solar Charger provides 8 standard battery charging algorithms (programs) that are selected with the DIP switches. These standard algorithms are suitable for lead-acid batteries ranging from sealed (gel, AGM, maintenance free) to flooded to L-16 cells and Ni-cad etc. In addition, an 8th DIP switch provides for custom set points using the two potentiometer (VR2, VR1) The table below summarizes the major parameters of the standard charging algorithms. Note that all the voltages are for 12V systems (24V = 2X, 48V = 4X). All values are 25 C (77 F). DIP Switches (4-5-6) A Battery Type B Bulk Voltage C Float Voltage D Equalize Voltage E Equalize Time (hours) F Equalize Interval (days) off-off-off 1 Sealed 14.0 13.4 None - - off-off-on 2 Sealed 14.1 13.4 14.2 1 28 off-on-off 3 - Sealed 14.3 13.4 14.4 2 28 off-on-on 4 - Flooded 14.4 13.4 15.1 3 28 on-off-off 5 - Flooded 14.6 13.4 15.3 3 28 on-off-on 6 - Flooded 14.8 13.4 15.3 3 28 on-on-off 7 - L-16 15.0 13.4 15.3 3 14 on-on-on 8-NiCad 16.0 14.5 None - - 8-on Custom VR2 VR1 VR2+1V 2 7 Table 4.2 Standard Battery Charging Programs A. Battery Type These are generic lead-acid and Ni-cad battery types. See Section 8.0 for more information about battery types and appropriate solar charging. B. BULK Voltage This is the PWM Absorption stage with constant voltage charging. The PWM voltage is the maximum battery voltage that will be held constant. As the battery becomes more charged, the charging current tapers down until the battery is fully charged. C. Float Voltage When the battery is fully charged, the charging voltage will be reduced to 13.4 volts for all battery types. D. Equalization Voltage During an equalization cycle, the charging voltage will be held constant at this voltage. E. Equalization Time The charging at the selected equalization voltage will continue for this number of hours. This may take more than one day to complete. F. Equalization Interval Equalizations are typically done once a month. Most of the cycles are 28 days so the equalization will begin on the same day of the month. It can be set by Dip 34 090136.02 Solar charger SL45, SL60

Switch 4~6 for different interval days. Each new cycle will be reset as the equalization starts so that a setting day period will be maintained. These 8 standard battery charging algorithms will perform well for the majority of solar systems. However, for systems with specific needs beyond these standard values, any or all of these values can be adjusted using the potentiometers VR2 and VR1. 4.3 4.3.1 Temperature Effects Battery Temperature Sensor (BTS) The BTS is used for temperature compensated battery charging. As the battery gets warmer, the gassing increases. As the battery gets colder, it becomes more resistant to charging. Depending on how much the battery temperature varies, it may be important to adjust the charging for temperature changes. There are three battery charging parameters that are affected by temperature: PWM Absorption This is the most important part of charging that is affected by temperature because the charging may go into PWM absorption almost every day. If the battery temperature is colder, the charging will begin to regulate too soon and the battery may not be recharged with a limited solar resource. If the battery temperature rises, the battery may heat and gas too much. Equalization A colder battery will lose part of the benefit of the equalization. A warmer battery may heat and gas too much. Float Float is less affected by temperature changes, but it may also undercharge or gas too much depending on how much the temperature changes. The BTS corrects the three charging set points noted above by the following values: 12 volt battery: 0.030 volts per C ( 0.017 volts per F) 24 volt battery: 0.060 volts per C ( 0.033 volts per F) 48 volt battery: 0.120 volts per C ( 0.067 volts per F) Variations in battery temperature can affect charging, battery capacity, and battery life. The greater the range of battery temperatures, the greater the impact on the battery. For example, if the temperature falls to 10 C (50 F) this 15 C (27 F) change in temperature will change the PWM, equalization and float set points by 1.80V in a 48V system. Solar charger SL45, SL60 090136.02 35

Temperature 12 Volt 24 Volt 48 Volt 50 C / 122 F 0.75 V 1.50 V 3.00 V 45 C / 113 F 0.60 V 1.20 V 2.40 V 40 C / 104 F 0.45 V 0.90 V 1.80 V 35 C / 95 F 0.30 V 0.60 V 1.20 V 30 C / 86 F 0.15 V 0.30 V 0.60 V 25 C / 77 F 0 V 0 V 0 V 20 C / 68 F + 0.15 V + 0.30 V + 0.60 V 15 C / 59 F + 0.30 V + 0.60 V + 1.20 V 10 C / 50 F + 0.45 V + 0.90 V + 1.80 V 5 C / 41 F + 0.60 V + 1.20 V + 2.40 V 0 C / 32 F + 0.75 V + 1.50 V + 3.00 V Table 4.3 Temperature Compensation The need for temperature compensation depends on the temperature variations, battery type, how the system is used, and other factors. If the battery appears to be gassing too much or not charging enough, an BTS can be added at any time after the system has been installed. The Vetus Solar Charger will recognize the BTS when the controller is started (powered-up). 4.4 Equalization Routine equalization cycles are often vital to the performance and life of a battery particularly in a solar system. During battery discharge, sulphuric acid is consumed and soft lead sulphate crystals form on the plates. If the battery remains in a partially discharged condition, the soft crystals will turn into hard crystals over time. This process, called lead sulphation, causes the crystals to become harder over time and more difficult to convert back to soft active materials. Sulphation from chronic undercharging of the battery is the leading cause of battery failures in solar systems. In addition to reducing the battery capacity, sulfate build-up is the most common cause of buckling plates and cracked grids. Deep cycle batteries are particularly susceptible to lead sulphation. Normal charging of the battery can convert the sulphate back to the soft active material if the battery is fully recharged. However, a solar battery is seldom completely recharged, so the soft lead sulphate crystals harden over a period of time. Only a long controlled overcharge, or equalization, at a higher voltage can reverse the hardening sulphate crystals. In addition to slowing or preventing lead sulphation, there are also other benefits from equalizations of the solar system battery. These include: 36 090136.02 Solar charger SL45, SL60

Balance the individual cell voltages. Over time, individual cell voltages can drift apart due to slight differences in the cells. For example, in a 12 cell (24V) battery, one cell is less efficient in recharging to a final battery voltage of 28.8 volts (2.4 V/c). Over time, that cell only reaches 1.85 volts, while the other 11 cells charge to 2.45 volts per cell. The overall battery voltage is 28.8V, but the individual cells are higher or lower due to cell drift. Equalization cycles help to bring all the cells to the same voltage. Mix the electrolyte. In flooded batteries, especially tall cells, the heavier acid will fall to the bottom of the cell over time. This stratification of the electrolyte causes loss of capacity and corrosion of the lower portion of the plates. Gassing of the electrolyte from a controlled overcharging (equalization) will stir and remix the acid into the battery electrolyte. NOTE: Excessive overcharging and gassing too vigorously can damage the battery plates and cause shedding of active material from the plates. An equalization that is too high or for too long can be damaging. Review the requirements for the particular battery being used in your system. 4.4.1 Standard Equalization Programs Both automatic and manual equalizations can be performed using either the standard charging programs or a custom setting. Manual Equalization The Vetus Solar Charger is shipped with the DIP switch set for manual equalization only. This is to avoid an unexpected or unwanted automatic equalization. In the manual mode, the push button is used to both start and stop a manual equalization. Hold the push button down for 5 seconds to start or stop an equalization (depending on whether an equalization is in progress or not). There are no limits to how many times the push button can be used to start and stop equalizations. Equalizations will be terminated automatically per the charging program selected if the push button is not used to manually stop the equalization. Automatic Equalization If the equalization DIP switch is moved to the ON position), the equalizations will begin automatically per the charging program selected. Other than starting, the automatic and manual equalizations are the same and follow the standard charging program selected. The push button can be used to start and stop equalizations in both the manual and automatic mode. Solar charger SL45, SL60 090136.02 37