TXM1.6R TXM1.6R-M. Relay modules TX-I/O

Similar documents
Digital input modules

TX OPEN RS232/485 module

Air damper actuators

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

HCR3.2/.. Chipcard reader HOTEL SOLUTION

PCS0100en Persy Control Services B.V. Netherlands

Product and functional description

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Safety technique. Emergency stop module BO 5988 safemaster

Modular I/O System Analog and Digital Interface Modules

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Duct Humidity Transmitter

SYSTEM 45. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design

48 SERIES Relay interface modules 10 A

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

VAV compact controller KNX / PL-Link

E-STOP relays, safety gate monitors

PXM20-E. Operator unit DESIGO PX

PHOENIX CONTACT Features

IO-RM3 3-Stage Relay Module

Electronic overload relay EF19 and EF45

RM4TG20 three-phase network control relay RM4-T - range V

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

49 Series - Relay interface modules A. Features

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

CONFIGURABLE SAFETY RELAYS

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

ACS-30-EU-EMDR-10-MOD

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

CONFIGURABLE SAFETY RELAYS

Contact expansion modules

SYSTEM DESCRIPTION Termination Boards

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

PSR The compact range Description

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

mecotron Safety relay ESTOP-2 For emergency stop monitoring

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

VAV compact controller KNX / PL-Link

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Electronic overload relay EF65, EF96 and EF146

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Contact expander modules

FIREDEX Conventional Fire Panels

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

OZW30. Central Unit SYNERGYR

Drayton Digistat +2RF/+3RF

Combi B Alarm box. Mounting instructions

ABB i-bus KNX SA/S Switch Actuators Product Manual

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

RRV934. Multi-controller. Synco living

Electric Rotary Actuator - On/Off or programmable control actuator

PNOZsigma - Base units

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

StructureScan HD Module. Installation Guide ENGLISH

Relés e Contatores de Estado Sólido SIRIUS

MINI MCR-SL-R-UI(-SP)

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

OZS Web server. For LPB/BSB plants

HERZ-Thermal Actuators

Three-phase monitoring relay CM-PFE

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Control Devices Catalogue. Control Devices. Preferred and Standard Products

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CQM1-SF200/CS1W-SF200

Phone: Fax: Web: info@clrwtr.com

ZC-24DO CANopen I/O Module: 24 Digital Outputs

MasterINTERFACE 39 Series - Relay interface modules

Bimetallic Overload Relay Specifications

R.C.C.B. s two-pole LEXIC

Advantium 2 Plus Alarm

E-STOP relays, safety gate monitors

Manual & Technical Documentation V1.1

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Transcription:

8 175 TX-I/O s TXM1.6R TXM1.6R-M Two fully compatible versions: TXM1.6R: 6 volt-free relay outputs Individual I/O point signaling with green I/O status LED TXM1.6R-M: As TXM1.6R, but with the following additional features Three-color I/O status LED (red, yellow or green) Local override (to ISO 16 484-2) 6 relay outputs, which can be individually configured as: Maintained contact or pulse, 1 -stage Three-position control output with stroke algorithm Mixed voltages (AC 250 V mains voltage and SELV/PELV 24 V) as well as mixed phases are permitted on adjacent I/O points of the module Compact DIN format, small footprint Separate terminal base and plug-in I/O module for convenient handling Self-establishing bus connection for maximum ease of installation Terminal isolation function for fast commissioning I/O module replaceable in seconds, without rewiring and without affecting the full functioning of the remaining I/O modules Terminal strips are required to connect N and PE of the field devices Simple strategy for operation and display I/O status LED for each I/O point LEDs for fast diagnostics Double-sided labels for identification of all I/O points CM2N8175en_07 2014-12-18 Building Technologies

Functions The modules support the following I/O functions: Signal type (TRA) Signal type Description BO Relay NO 250V Q250 Maintained contact relay, changeover contact BO Relay NC 250V N/O, N/C contact BO Pulse On-Off Q250-P Q250A-P On/off pulse Q250-P With self-latching and 2 channels Q250A-P With dual-winding switch BO Pulse *) Pulse MO Steps Q-M1 M4 Multistate maintained contact, 1 6-stage mutually exclusive electronic relay interlock MO Pulse Q250-P1 P5 Multistate pulse, 1 5-stage mutually exclusive electronic relay interlock BO -Pos Relay Y250T Pulse, control signal, three-position output, internal algorithm for stroke running time *) DESIGO V4, V5: se MO Q250-P1. For a detailed description of these functions, please refer to document CM110561, "TX-I/O functions and operation". Notes Q250B se TXM1.6RL with BO Bistable NO / NC For switched current <100mA, see CM11056, Replacement of legacy signal types. QD Feedback must be implemented using separate digital inputs e.g. with TXM1.8D, see CM11056. Compatibility Support of signal types and functions in different building automation and control systems: see TX-I/O Engineering and installation manual, CM110562 Type summary ASN TXM1.6R TXM1.6R-M with local override Delivery Accessories The terminal base and the plug-in I/O module are interconnected and delivered in the same box. The available accessories include address keys, label sheets, and spare transparent label holders. Refer to data sheet CM2N8170. 2/10

Technical and mechanical design For a description of the features common to all TX-I/O modules, please refer to the TX-I/O Engineering and installation manual, document CM110562. Indicators and operator controls Connection terminals (No. 1 screwdriver for slotted or recessed-head * screws) with test pickup (for 1.8...2 mm pins) and terminal number Signal designation Override status LEDs (yellow) Address key and module status LED I/O point numbers Override button (TXM1.6R-M only) I/O status LEDs (TXM1.6R: green; TXM1.6R-M: colors can be configured, green/yellow/red) * Combined slotted / recessed-head screws from mid-2012 I/O status LEDs Module status LEDs Address key Terminals The I/O status LEDs indicate the status of the relays The LEDs on the TXM1.6R are green. In the case of the TXM1.6R-M the LEDs are three-colored. If the I/O function supports it, the module can display Alarm = red and Service = yellow, besides Normal = green The LEDs are also used for diagnostics The module status LED illuminates the transparent address key The (green) LED shows the module status as a whole (as opposed to the I/O points) It is also used for diagnostics The module operates only with the address key inserted The module address is mechanically encoded in the address key When replacing the plug-in I/O module, the address key must be swiveled outward. It remains plugged into in the terminal base. The relay contacts of the individual I/O points are volt-free, and are not interconnected. The switched voltage must be provided separately for each I/O point. Mixed voltages (AC 250 V mains voltage and SELV/PELV 24 V) as well as mixed phases are permitted on adjacent I/O points of the module /10

Local override (TXM1.6R-M only) Override button Override status LED Warning Pressing an override button in the middle enables/disables local override Pressing "+" for one of the I/O points activates the relay or switches control to the next stage up (depending on function) Repeated or sustained pressure switches several stages until the function stops at the highest stage. Pressing " " for one of the I/O points deactivates opens the relay or switches control to the next stage down (depending on function) Repeated or sustained pressure switches several stages until the function stops at the lowest stage. The yellow "Override" LED indicates that local override is active All safety-relevant functions must be implemented with external solutions The local override must not be used for safety shutdown operations In compliance with the standard (ISO 16 484-2, Section.110), the module executes all local overrides directly, without safety precautions or interlocks. Full responsibility lies with the operator. Module labeling The plug-in I/O module has a removable transparent cover (the label holder) for insertion of a label. 2 1 8172z11 Disposal The device is classified as waste electronic equipment in terms of the European Directive 2012/1/E (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. 4/10

Engineering, mounting, installation Please refer to the following documents Document TX-I/O functions and operation TX-I/O Engineering and installation manual Replacement of legacy modules Number CM110561 CM110562 CM11056 Mounting Permitted orientation The TX-I/O devices can be installed in any orientation: It is important to provide adequate ventilation so that the admissible ambient temperature (max. 50 C) is not exceeded. Technical data Supply (bus connector on side) Operating voltage DC 21.5... 26 V Extra low voltage SELV or PELV in accordance with HD84 Max. power consumption TXM1.6R 1.7 W TXM1.6R-M 1. W (for the sizing of power supplies, see CM110562) Protection Bus connector on side No protection against shortcut and incorrect wiring with AC / DC 24 V Switching outputs Number of switching outputs 6 (changeover contact) External fuse protection for incoming cable Slow blow fusible link Max. 10 A Circuit breaker Max. 1 A Circuit breaker tripping characteristic Type B, C or D to EN 6088 Insulation resistance Contact data AC/DC switching voltage AC current rating DC current rating max. AC 250 V / DC 0 V min. AC / DC 12 V Max. 4 A resistive, A inductive Min. 1 ma at AC 250 V Min. 10 ma at AC 12 V FLA, LRA, 1/4 HP, 4 () A Max. A resistive at DC 0 V Min. 10 ma resistive at DC 12V Current on make Max. 10 A (1 s) Response / dropout time 7 ms / ms typical Service life of contact for AC 250 V (guide values) With 0.1 A resistive 1 x 10 7 switching operations With 0.5 A resistive x 10 6 switching operations With 4.0 A resistive (N/O) 2 x 10 5 switching operations Reduction factor with inductive load 0.85 (cos phi = 0.6) Reinforced insulation between relay outputs and AC 750 V, to EN 60 70-1 system electronics Mixed voltages (AC 250 V mains voltage and SELV/PELV 24 V) as well as mixed phases are permitted on adjacent I/O points of the module 5/10

Connection terminals Mechanical design Solid conductors Stranded conductors without connector sleeves Stranded conductors with connector sleeves (DIN 46228/1) Screwdriver Cage clamp terminals 1 x 0.5 mm 2 to 4mm 2 or 2 x 0,6 mm to 1.5 mm 2 1 x 0.5 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 1 x 0.25 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 No. 1 Screwdriver for slotted or recessed-head * screws with shaft diameter 4.5 mm * Combined slotted / recessedhead screws from mid-2012 0.6 Nm Max. tightening torque Test pickups (terminals) For pin diameter 1 x 1.8 2.0 mm Local override (TXM1.6R-M only) Local override device ISO 16 484-2, Section.11 Classification to EN 6070 Housing protection standard Ambient conditions Mode of operation of automatic electrical controls Contamination level Mechanical design Protection standard to EN 6502 Front-plate components in DIN cut-out Terminal base Operation Climatic conditions Temperature Humidity Mechanical conditions Operation Climatic conditions Temperature Humidity Mechanical conditions Type 1 2 Devices are suitable for use in equipment with protective class I and II IP0 IP20 To IEC 60721-- Class K5-5...50 C 5 5 % rh Class M2 To IEC 60721--2 Class 2K -25 70 C 5 5 % rh Class 2M2 Standards and directives Product standard EN 6070-1 E conformity (CE) T10870xx *) Electromagnetic compatibility (EMC) For use in residential, commercial and industrial environments RCM conformity (EMC) T10870en_C1 *) *) The documents can be downloaded from http://siemens.com/bt/download. L approbation L 16, L 864 Environmental compatibility The product environmental declaration CM1E8174 contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) ISO 14001 (Environment) ISO 001 (Quality) Color Terminal base and plug-in I/O module RAL 705 (light gray) Dimensions Housing to DIN 4 880, see "Dimensions" Weight Without / with packaging TXM1.6R 21 / 252 g TXM1.6R-M 241 / 262 g 6/10

AC / DC 24... 20 V Connection diagrams (examples) Terminal layout TXM1.6R, TXM1.6R-M I/O point () (4) (5) (6) Supply 20 26 2 N/O contact 2 8 14 21 27 N/C contact 4 10 16 1 25 1 For functions with several I/O points: Always use adjacent I/O points Each function must be confined to one module only The I/O points have a fixed sequence within the function, e.g. the first I/O point is for switch-off. Maintained contact BO Relay NO 250V BO Relay NC 250V AC / DC 24... 20V () 2 4 Q1 8 10 Q2 14 16 K 8175z1_01 Q1 Switched load (N/O contact) Q2 Switched load (N/C contact) K Step switch / pulse switch / bistable relay On/off pulse BO Pulse On-Off Self-latching and 2 channels (Q250-P) Dual-winding switch (Q250A-P) AC / DC 24... 20 V Q250-P Q250A-P () (4) 14 16 21 1 20 K2 AC / DC 24... 20 V 8175z14 Power contactor, self-latching K2 Dual-winding stepping switch, bistable relay Pulse on I/O point (2) = ON Pulse on I/O point (1) = OFF Pulse on I/O point (4) = K2 ON Pulse on I/O point () = K2 OFF Pulse control for singlestage load with control from two separate control loops of equal status BO Pulse On-Off () (4) 14 16 21 1 20 Power contactor, self-latching Control circuit 1: Pulse on I/O point (2) = ON Pulse on I/O point (1) = OFF 8175z1 Control circuit 2: Pulse on I/O point (4) = ON Pulse on I/O point () = OFF 7/10

Pulse control for singlestage load with control of equal status from two remote switching locations BO Pulse On-Off 2 4 8 10 S1 S S2 S4 AC / DC 24... 20 V 8175z20 Power contactor, self-latching Control circuit 1: Pulse on I/O point (2) = ON Pulse on I/O point (1) = OFF External control location A: S1 OFF button S2 ON button External control location B: S OFF button S4 ON button Maintained contact, -stage MO Steps () 14 16, K2, K Contactors for Stages 1 AC / DC 24... 20 V K2 K 8175z I/O point (1) ON = Stage 1 I/O point (2) ON = Stage 2 I/O point () ON = Stage Pulse, 1-stage DESIGO V4, V5: se Q250-P1 DESIGO TRA se BO Pulse Pulse, -stage MO Pulse () (4) 14 16 21 1 20, K2, K Contactors with selflatching feature for Stages 1 AC / DC 24... 20 V **) K2 *) K *) *) K *) K2 *) K2 *) K 8175z16 Pulse on I/O point (1) = OFF Pulse on I/O point (2) = Stage 1 Pulse on I/O point () = Stage 2 Pulse on I/O point (4) = Stage *) External self-latching is optional **) For other means of control, replace bridge with external circuit 8/10

Pulse control for a threestage load with control from two control loops of equal status MO Pulse 1 () (4) 14 16 21 1 20 2 () (4) 14 16 21 1 20 K2 *) *) *) K *) K *) K2 *) AC / DC 24... 20 V K2 K 8175z21 1, 2 s Control loop 1: 1 Pulse on I/O point (1) = OFF 1 Pulse on I/O point (2) = Stage 1 1 Pulse on I/O point () = Stage 2 1 Pulse on I/O point (4) = Stage, K2, K Contactors with self-latching feature for Stages 1 *) External self-latching is optional Control loop 2: 2 Pulse on I/O point (1) = OFF 2 Pulse on I/O point (2) = Stage 1 2 Pulse on I/O point () = Stage 2 2 Pulse on I/O point (4) = Stage Control signal, threeposition output BO -Pos Relay AC / DC 24... 20 V 2 4 Y1 M 8 10 Y2 Y1 Y2 8175z17 Control signal OPEN Control signal CLOSE /10

Dimensions Dimensions in mm 0 67 45 22 44 70 77.5 7.1 8 108 64 8172M01 10/10 2007 Siemens Switzerland Ltd Subject to change