2 Page Electroac0ustic. for a maximum of system security. Part 2. Emergency warning system

Similar documents
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

T Zone Weekly Timer

Product Information Fire alarm panel 8000 C

ABUS WIRELESS ALARM SYSTEM

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Plena Voice Alarm System. Software Manual Configuration Software

9452/9453 Installation and User Guide

EN54-16 Voice Alarm System PRODUCT DATASHEETS

GSM Alarm System User Manual

Plena Voice Alarm System. Installation and Operation manual

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

Memcom Emergency Telephone

TS-770 SERIES CONFERENCE SYSTEM

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

FIREDEX Conventional Fire Panels

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

Voice alarm system E100 the new standard for safe evacuation

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

PagePac PAGEPAL V

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Product Information Sheet UH36 Hi Pot Tester

1 All safety instructions, warnings and operating instructions must be read first.

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

Permissible ambient temperature Operation Storage, transport

VM-3000 Series. With new features! Integrated Voice Evacuation System. sound without compromise.

Quick Connect. quick - simple - efficient.

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Repeaters and Mimics Data Sheet

AC-115 Compact Networked Single Door Controller. Installation and User Manual

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

Safety Relays ESM/ESM-F

1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.

Public Address and Voice Alarm

PM1122 INT DIGITAL INTERFACE REMOTE

Emergency voice communications Product Name

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Praesideo - Digital Public Address and Emergency Sound System

HCS-3600MB2 Conference Main Unit

Communication A BRITISH MANUFACTURER. Features:

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Alliance System Ordering Guide

Always on the Lookout Perfect Protection against Burglary

Input module, input/output module

GST301. (Single Protection Zone) Operation Manual

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

T Substation Maintenance and Commissioning Test Equipment

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

C e r t i f i c a t e of Conformity

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI

User's Guide. Integrating Sound Level Datalogger. Model Introduction

TS510 & TS500. Installation & User Guide. Compatible Equipment

sat-nms SMU Signal Management Unit

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

USER S MANUAL LEN15M

OZW30. Central Unit SYNERGYR

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

XIA-USB INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

VEGA Analogue Addressable Control Panels

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Business/Home GSM Alarm System. Installation and User Manual

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Setting Up the Cisco Unified IP Phone

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Honeywell Security. Honeywell Hello Series Video Door Phone System Product Catalog. Smile reaches your heart. Smile reaches your heart

ATS Control Panel. User s Manual

Digital FM/AM Receiver

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

TAC I/NETTM. Intrusion Alarm System

telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR

Monitors. Platea Monitor

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Notifier by Honeywell: Voice Alarm Solutions

Plena Weekly Timer. Installation and User Instructions PLN-6TMW

ZC-24DO CANopen I/O Module: 24 Digital Outputs

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

computer radio control system

FLOOR INDICATORS CATALOGUE 2007

FIRE DETECTION SYSTEMS ALARM STRATEGIES 2.0. New Version

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

GC2 Panel User Guide

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

GSM ATT Modules Simply effective remote control

ACTIVE 5 ENGINEERING MANUAL

SYSTEM MONITORING Locally and remotely

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

ETHERNET based public address and voice alarm system

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

AC3200 INTELLIGENT BROADBAND AMPLIFIER

M-Bus-Logger Data Logger

Transcription:

Emergency warning system 2 Page 25 30 Part 2 FOR 12 LINES Electroac0ustic emergency warning SYSTEM EN 54-16 / VDE 0833-4 / VDE 0828 / IEC 60849 for a maximum of system security

Control-Center Rear view ESC-012A A Power supply input 230 V AC B Output relay contact Emergency A + B C Output relay contact Error and Power failure D Input 24V-DC emergency power supply E Input backup amplifier F Speaker line 1-12 G Fire brigade call station 1 (FWS1 with priority of FWS2) H Fire brigade call station 2 (FWS2) I Input for annunciator 1-3 J Input for annunciator 4-6 K Line-level input program 1 L Line-level input program 2 M Line-level output for Equalizer N Line-level input for Equalizer O Line-level output for 100V amplifier 1-6 P Line-level output for 100V backup amplifier Q Contact input to activate program 2 R Memory card for Textmessages S Serial Interface RS232 for Printer T Digital Interface RR-120 (optional) Technical data Speaker lines VARES ESC-012A 12 lines, max. 480 W each (6 lines with ELM-106) Fire Brigade call stations 2x ESM-100D suitable for connection Digital microphone stations up to 10 devices ELM-106 (not monitored) Signal outputs 13x NF 0dB; transformer balanced; 12 x 100V Signal inputs 2x NF 0dB; unbalanced (Prg 1 + Prg 2); 13x 100V; 6x upervised switching inputs for text or alarm activation (input 6 has a special function to analyse external errors r) Switching outputs (max. 120V AC; max. 2A AC) 2x Emergency (break or open contact) 1x Error (break or open contact) 1x Power failure (break or open contact) PC-interface RS-232 Voice memory SD-card Display LCD 64 x 128 px, LEDs Control panel 2 buttons, 6 programming buttons, selection wheel Power supply 230V AC, 24V DC Power consumption < 40 W Dimensions (WxHxD) 483 x 89 x 340 mm, 2 RU Weight 6,7 kg Digital Microphone Station ELM-106 ELE-006 ELE-004 ELM-106 manages announcements into one or more selected zones and all-calls. An expansion to handle 12 call zones is possible by the use of an optional six-button module ELE-006. On an overall bus length of 100 m on CAT7 cable up to ten pcs. ELM-106 can be connected to a single ESC-012 A. For larger distances please use lower resistance cables. With the extension module ELE-004 can be extended to a covered alarm button, three buttons for special functions and 2 fault LED s. * Digital Microphone Station, Electret microphone with cardioid characteristic................................................................ ELM-106 Digital Microphone Station, as ELM-106, but without interface RR-120............................................................... ELM-106 WO Button Extension Module, for ELM-106 to handle 12 call zones............................................................................ ELE-006 Function Extension Module, for ELM-106 to expand with further functions.................................................................. ELE-004 26

CONTROL-CENTER Lifesaving in the case of an emergency! In the case of an alarm, an electroacoustic emergency warning system may avoid panic by understandable speaker announcements, which are, contrary to the howling of a siren, a much more efficient way of initiating the evacuation of a building. Certainly, the availability and safe working of such systems has to be guaranteed at any time by monitoring the complete signal path. The standard IEC 60849/ VDE 0828 and VDE 0833-4 defines the requirements for such systems. Control-Center ESC-012A VARES ESC-012 A has been developped in full accordance to the latest rules and regulations for security. Targeted towards small and medium-scaled usage scenarios, it handles all the tasks and challenges a voice alarm systems faces in everyday life. Installation is handled in an easy and straightforward way by using the LCD based user interface. All connected auxiliary components are scanned and registered automatically. Speaker lines can be configured in 12 single or 6 A/B lines for an increasd of security. Even a mix of single and redundant line setups for custom scenarios is possible. A logging function stores all system conditions on non-volatile memory in any case of a technical failure. The generated protocol can be viewed immediately or sent to a printer. Specifications: Graphical user interface with adjustable colour scheme, in any case of an alarm the display flashes in red colour. Menu interface with digital rotary encoder. Password protected menu interface. Fully variable assignment of up to 12 speaker lines to a maximum of 6 power amplifiers, maximum amplifer power is 480 W each. A faulty power amplifier is detected and replaced by the backup amplifier automatically. Two line level inputs of different priority levels can be used for various tasks, like background music distribution or paging via a telephone system. Free assignment of the program to any of the 12 speaker lines. The internal digital message memory (based on an SD card) is equipped with an evacuation announcement, a siren according to DIN 33404 and various different chimes (one tone and four tones). All 12 speaker lines are monitored for short circuits, line breaks and impedance variation. Error messages are provided by clear text display, signalling LED, sounder and dry contact. Up to 10 digital call stations ELM-106 can be connected. ELM-106 call stations can be expanded to address 12 zones by ELE-006 expansion units. Indicated here is the different reaction pattern to siren signals or a spoken message. Model designation Emergency microphones ESM- 100D and ESM-020H enjoy individual 3-band equalisation for best intelligibility of any announcement (up to two emergency microphones can be connected). VARES Control-Center, 2 RU.....................ESC-012 A * 27

example of use Example of an emergency warning system compliant to IEC 60849 Emergency Desk-Micro Emergency Power-Supply Digital Remotemicrophones* ESM-100D up to10 pcs. ELM-106/WO ESP-500 A VARES Emergency Control-Center House alarm and Microphone Monitoring Text Module, Digital Speech Memory Fire-Alarm-Transfer Monitoring Speaker Line Monitoring Line Current and Battery Monitoring Automatic Error Log Recording HMH-001 B ESC-012A Various Devices* Backup e.g.: ME-2 A with sound source Modules BA-480DP BA-240 DP BA-240 DP BA-480 DP BA-480 DP BA-120 DP BA-120 DP Possible connection of one to six Disconnection of all non safety-relevant components when in emergency announcement operation. 2 monitored emergency call stations. * unsupervised devices 28

ACCESSORIES Fire Brigade Call Station Fire Brigade Handheld Mic In addition to the monitored microphone, the station ELM-106 can be used. The call station is electronically monitored compliant to VDE 0828/IEC 60849. Measured values of the microphone cap, the entire signal path and the press-to-talk bar are detected and analysed. The direct connection with VARES is made by a 4-pin shielded cable. The stable slim desktop housing has a functional design. It is suitably coloured for the specially targeted application. VARES Fire Brigade Call Station.............. ESM-100D The handheld microphone is electronically monitored compliant to VDE 0828/IEC 60849. Measured values of the microphone cap, the entire signal path and the press-to-talk bar are detected and analysed. The direct connection with VARES is made by a 4-pin shielded cable. The handy, coloured housing with its lateral press-to-talk bar is optimized for its special purposes. VARES Fire Brigade Handheld Mic.......... ESM-020 H VARES Software Languages Housing and Mounting Panel for ESM-020 H VMF-020 A VCF-020 A VARES Language Options As alternatives to English and German ESC-012A offers a variety of menu languages as options: 1. German (factory setting, at no extra charge) 2. English ESL-001/2 3. Czech ESL-001/3 4. Spanish ESL-001/4 5. Italian ESL-001/5 6. Polish ESL-001/6 VARES Software Language.....................ESL-001/X (Please replace the X by corresponding last digits, at ordering) The Mounting Panel VMF-020 A for the fire brigade microphone ESM-020 H provides installation in a standard housing according to DIN 14661 and DIN 14662 and can thus be integrated in a fire control panel. The housing VCF-020 A is optional, if no fire brigade control panel is available. It is designed as a standard housing according to DIN 14661 and DIN 14662, in red (RAL 3000). The housing with transparent door, lockable with on-site fire brigade profile half cylinder according to DIN 18252. Protection type: IP40, DIN 40050 Surface design according to DIN 14663 The ESM-020 H is part of the certification to EN 54-16 Mounting Panel, for ESM-020 H....................... VMF-020 A Housing, for ESM-020 H (without mounting panel)............. VCF-020 A Dimensions (WxHxD): 250x180x60 mm, 4 kg 29