IBM System Storage. EXN1000 Installation and Setup Instructions

Similar documents
IBM System Storage. N3300 Installation and Setup Instructions

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

HP UPS R1500 Generation 3

HP 16/18-Port Cable Management Kit Installation Guide

Rack installation instructions

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

About the BitStorm 6051 POTS Splitter

Rack Installation Instructions

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

The power module is Feature Number 8800-F2-901.

MCR1900 Media Converter 19-Slot Chassis

How to Set Up Your NSM4000 Appliance

E2600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

DE1600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

Installation. Basic Rack Power Distribution Unit for Blade Servers

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

PS6500 Storage Arrays Rack Mount Instructions

430 Power/Electronics Replacement

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

IBM System Storage EXN1000 SATA expansion unit can now be ordered as partially populated and attaches to the N3700 filers

42U/45U 28" Wide Rack Installation & Service Guide

Set Up Your MXI -Express x1 System

Set Up Your MXI -Express x4 System

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

HP R12000 and R18000 DirectFlow UPS User Guide

UPGRADING AND SERVICING GUIDE

Small form factor bay converter and hard drive installation

About the HotWire Slot Standalone Shelf

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

HP 22-in-1 Media Card Reader

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

HP SATA/SAS hard drive and Solid State Drive installation

BX7000 Multi-Access Gateway Getting Started Guide

ATS Overhead Table Shelf System INSTRUCTION MANUAL

How To Install A Cisco Cisco 520-T1 Router On A Network Card (Cisco) With A Network Cable (Cio) And A Network (Cnet) (Coconc) (Net) And An Ipo (

ASKING FOR ASSISTANCE

1500 Follow Spot Yoke

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Wall-Mounting your HP computer. User Guide

CETAC Z-Drive Assembly

Unpacking, Installation, and Customization

Part Name/Description Part Number Quantity. Power Cable

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Rack Installation Instructions

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Installing Your 960 or 980 Server into a Rackmount Cabinet

Replacing the Gateway M675 Keyboard

4RU High Density Shelf Installation Instructions

Replacing a Vantage Vue Transmitter

BRACKET LOCKING SCREW

EVID Compact Sound Speaker System

Installation Instructions For Slider Casement Air Conditioners

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

Front Panel Board Cable Replacement Instructions

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

DCF Optimized Rack System

HermanMiller Aeron Posturefit Installation AE905A AE905B AE905C

UNPACKING AND ASSEMBLY

UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Out-of-box comparison between Dell, HP, and IBM blade servers

Raritan LCD KVM Console (T1700/T1900)

3500/93 System Display

Acano solution. Acano Solution Installation Guide. Acano. January B

Installation Instructions

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

Contractors Guide Central Inverter System Installation

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

FT Server. Fault Tolerant Server Platform. Instruction Manual

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

Installing Cisco TelePresence MX200 G2 - Wheel Base

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

Cable Routing Procedures for Dell PowerEdge R310 & R410 Systems

AU-110 racking guide NBXPN: 023

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Bubble King. User Manual

Anthro Tablet Charging Cabinets

Power Supply Guide Version 1.0 for D-Show

INSTALLATION INSTRUCTIONS

Service Guide. Gateway M275

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

PDI-P10LCD Pre-Tensioned Swivel Cartridge

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Refer installation of power supplies to qualified service personnel.

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Uninterruptible Power Supply. 500 kva kva

Out-of-box comparison between Dell and HP blade servers

RM410. Hardware Installation Guide. Quick Start Guide. Rack Mounting Kit. Version 1.00 Edition 1, 12/2012

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

Transcription:

IBM System Storage EXN1000 Installation and Setup Instructions

r This document provides installation and setup instructions for the IBM System TM Storage EXN1000 storage expansion unit. Additional information about the EXN1000 can be found in the IBM System Storage EXN1000 Storage Expansion Unit Hardware and Service Guide. Read the safety notices: Before continuing, make sure that you have reviewed the safety notices on the documentation CD that came with this system. Do not plug any cables into the system, adapters, or any electrical outlets until you have reviewed the safety information and followed the procedures in this document. Need help? If you encounter any difficulties while setting up your system, contact IBM service and support for assistance. Information can also be found at the following Web site: www.ibm.com/storage/support/nas/ Customer-supplied items needed for setup: #2 Phillips screwdriver and slotted screwdriver ESD wrist strap Pointed tool for setting ID switches 7-mm nut driver 1

1 Unpacking the EXN1000 (expansion unit) Important: If your system was shipped already assembled and cabled in a rack, go directly to the Installation and Setup Instructions of the storage system to boot the system. Accessory kit: - IBM rail kit - Power cables - Setup kit EXN1000 (expansion unit) 1 2 Note: The contents of the box will differ based on the model you purchased. See Step 1.1 for a list of contents for specific models.

1.1 Verify that the shipping packages include the following items: EXN1000 (2861-001) 1 EXN1000 1 IBM rail kit 1 Wrist Strap, ESD 1 Enclosure Shelf IDs Label 1 Publications 2 Power Cords Miscellaneous Data Cables May be present: Small Form Factor Pluggable (SFP) module 32 kg (70.5 lb) Caution: The weight of this part or unit is between 32 and 55 kg (70.5 and 121.2 lb). It takes three persons to safely lift this part or unit. (C010) 1.2 1.3 Remove the expansion unit and its tray using the handles built into the cardboard tray. Place the expansion unit and tray on a table. Remove the top portion of the plastic surrounding the expansion unit. 3

2 Installing the rails in an IBM 19-inch rack Note: Read this document in its entirety before proceeding. Rear of rack Front of rack Rail adjustment screws Left rail Locating pins Right rail 2.1 Loosen (but do not remove) the four rail adjustment screws on each rail. 2.2 Use the figure on the next page for reference. At the front of the rack, position the right-hand rail into the rack at the appropriate EIA location (make sure that the two locating pins seat properly). The bottom of the rail should line up with the bottom EIA boundary. Note: When installed, each EXN1000 unit will occupy a 3U space. Using two silver pan head M5 screws, attach the rail to the front of the rack using holes H3 and H7. Tighten these screws with a screwdriver. 4

2.3 At the rear of the rack, position the rail at the same EIA location used in step 2.2 (make sure that the locating pins seat properly). Using two silver pan head M5 screws, attach the rail to the rack using holes H2 and H8. Tighten these screws with a screwdriver. 2.4 Tighten the four rail adjustment screws on the installed rail. 2.5 Repeat steps 2.2 through 2.4 for the left-hand rail. 2.6 Repeat steps 2.1 through 2.5 if installing a second EXN1000. FRONT Left and Right Rails Section of rack EIA rail REAR Left and Right Rails H1 H1 Chassis attach screws H2 Top rail screws H2 1 EIA unit (1U) Top rail screws H3 H3 H4 Locating pins H4 H5 H5 H6 Locating pins H6 Bottom rail screws H7 H7 Chassis attach screws H8 Bottom rail screws H8 H9 H9 5

3 Installing the expansion unit into the rack 32 kg (70.5 lb) Caution: The weight of this part or unit is between 32 and 55 kg (70.5 and 121.2 lb). It takes three persons to safely lift this part or unit. (C010) Note: Verify the shelf IDs before installing into the rack. All shelf IDs should be correct and sequential in the individual loop(s). If the filer and expansion unit were configured together by manufacturing, these IDs are already set. The label on the front should match the switch on the back. For more information, refer to the Hardware and Service Guide for the expansion unit. 3.1 From the front of the rack, place the expansion unit onto the rails and slide it in until the front mounting bracket of the expansion unit is flush with the frame rails of the rack. 3.2 At the front of the rack, using four black hex head M5 screws in the H2 and H8 holes, secure the system unit to the rack by threading the screws through the system unit bracket and the rack frame rail into the threaded rail nuts. Tighten the screws using the 7-mm nut driver. 3.3 From the rear of the rack, use two silver pan head M5 screws to attach the rear of the chassis to the rails as shown below. 6 Screws

4 Setting the speed switch 4.1 Make sure that all expansion unit speed switches are set to the correct position for your application. If you are connecting to an N3700 storage system, the speed switch must be set to the 1Gb position. If you are connecting to any other N series storage system, the speed switch must be set to the 2Gb position. Note: You must remove the AT-FCX controller from the back of the EXN1000 to access the speed switch. Use the following diagrams for reference: 2 Gb 1 Gb 7

5 Grounding expansion units Note: For proper grounding, you must fasten together your expansion units (and N3700 systems, if applicable). Use the provided braided copper grounding cables and screws (may be in the rail kit). 5.1 If only one expansion unit is being used, go to Step 6, "Installing the power cables" on page 9. If two or more expansion units are being used continue with the following. Using the grounding kit, fasten the lug at one end of the 0.25m grounding cable to one of the two threaded inserts (adjacent to the power supply receptacles as indicated by a ground symbol) at the back of the expansion unit using the M5 x 0.5-inch screw. If additional expansion units need to be grounded, continue attaching the grounding cables from unit to unit, overlaying the hole on one end of the grounding cable from one to the next. Dual expansion unit grounding Multiple expansion unit grounding Grounding cable Grounding cables 8

6 Installing the power cables 6.1 Make sure all power supply switches of the expansion unit(s) are in the Off position. 6.2 Connect the power cords to all PSU1 and PSU2 power receptacles for all expansion units that are being installed by holding the wire clamp up, plugging in the power cord, and lowering the clamp to secure the power cord. 6.3 Connect the power cords to the power sources, making sure that the power supplies on the left side of the system are connected to a separate AC source than the power supplies on the right side of the system. This ensures redundant power. Caution: Do not power on the system at this time. 9

7 Cabling the EXN1000 7.1 Cable the first expansion unit (for example, ID=x=1) controller A Output port module to the second expansion unit ( for example, ID=x+1=2) controller A module Input port. Repeat as necessary to attach a third expansion unit ( for example, ID=x+2=3) to the second expansion unit. For dual-node connection, cable the expansion unit controller B Output port module to the expansion unit controller B module Input port. Repeat as needed. Make sure that the cables are secure. A In Out B Out In ID = x+2 (=3, for example) A In Out B Out In ID = x+1 (=2, for example) A In Out B Out In ID = x (=1, for example) 1 To Filer Notes: 1. To cable your expansion unit to an N series storage system, refer to the Installation and Setup Instructions for the N series storage system to which you are connecting the EXN1000. 2. For information about dual-path Fibre Channel cabling, refer to the Installation and Setup Instructions for the N series storage system to which you are connecting the EXN1000. 10

8 Additional resources - IBM System Storage N3700 Hardware and Service Guide, GA32-0515 - I BM System Storage N3300 and N3600 Hardware and Service Guide, GC27-2087 - IBM System Storage N5000 Series Hardware and Service Guide, GC26-7785 - IBM System Storage N7000 Series Hardware and Service Guide, GC26-7953 - IBM System Storage EXN1000 Hardware and Service Guide, GC26-7802 - IBM System Storage N series Introduction and Planning Guide, GA32-0543 - IBM Systems Safety Notices,G229-9054 - www.ibm.com/storage/support/nas/ 11

International Business Machines Corporation 2005, 2007 Printed in USA All Rights Reserved Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001 Internet URL: www.ibm.com/storage/support/nas References in this publication to IBM products or services do not imply that IBM intends to make them available in every country or region. IBM, the IBM logo, and System Storage are trademarks and/or registered trademarks of International Business Machines Corporation. Data ONTAP, NetApp, and Network Appliance are trademarks and/or registered trademarks of Network Appliance, Inc in the United States and other countries. Other company, product, and service names may be trademarks or service marks of others. NA 210-03789_A0 *1P45E0089* 45E0089 *07GC26778604* GC26-7786-04