CFO400 Series. User Manual CRT422 & CRR422. CFO422 User Manual, , rev002

Similar documents
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

NC-12 Modbus Application

F2400 FOM II Series Fiber Optic Modem Technical Manual

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

OPT SERIAL TO FIBER OPTIC CONVERTER

Gigabit Switching Ethernet Media Converters - Product User Guide

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

2-Pair HDSL1 Adtran Fiber Optic Link System

HDO700 P FIBRE OPTIC TRANSMITTER

DMX2PWM 9 Channel Dimmer Setup Manual

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide

Modular I/O System Analog and Digital Interface Modules

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

PCS0100en Persy Control Services B.V. Netherlands

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Software Manual RS232 Laser Merge Module. Document # SU Rev A

10/100/1000 Base-T to Gigabit Fiber Media Converter

Perle Fast Fiber to Fiber. Media Converters

FlexPoint T1/E1 Copper to Fiber Line Driver

Optimux-34, Optimux-25

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Perle Protocol Transparent Media Converter Modules

DS-7200HWI-SH/A Series DVR. Technical Specification

Optimux-134, Optimux-125

Single Port Gigabit Ethernet Media Converter Board (P/N xxx) User s Manual And Troubleshooting Guide

Setup guide. point to point wall plate extenders

Module Connectors and Cable Specifications

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Perle 10/100 Ethernet Media Converters

Bluetooth UART/RS232 Module

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

ZC-24DO CANopen I/O Module: 24 Digital Outputs

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

HDMI/DVI to VGA/Component & Audio Break out Converter

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Optimux-134, Optimux-125

ABB Drives. User s Manual HTL Encoder Interface FEN-31

CONTROL SWITCHER User s Manual (Preliminary)

RC8061 Pan and Tilt Camera Installation Guide

Provides one channel for Ethernet over existing

4UHD. SDX-8x8. Flexible and comprehensive professional Digital Modular Matrix (DMM) for Commercial, Education and Residential

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Inwall 4 Input / 4 Output Module

C24-CAMANL Video Server/Encoder

SNC-VL10P Video Network Camera

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

LwLVision-USB 2.0. Installation Guide

MANUAL PC1000R

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DS-7608NI-S Series NVR. Technical Manual

Product Information D23m Digital I/O System

User Manual. EtherUSB

Colour Video Monitors PVM-9045QM/9042QM/9040ME PVM-6041QM

HDMI over IP Broadcasting System ITEM NO.: HE05BT, HE05BER HDMI Matrix over IP Broadcasting

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D

AXIS 291 1U Video Server Rack Installation Guide

RFS-805. Digital Modulator AV to COFDM. User Manual

Perle Gigabit Fiber to Fiber Media Converters

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

RC8021 Indoor Camera Installation Guide

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

DS-7208HVI-ST Series DVR. Technical Manual

HP4000EX Hardware Manual

Auxiliary equipment for communication with the EuroProt protective devices

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

SD Rack. DiGiCo SD Rack. User Manual B - August

FlyingDream AAT Driver Quick Guide V1.1

MCR1900 Media Converter 19-Slot Chassis

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

REAR-VIEW CAMERA INTEGRATION FOR SELECT CHEVROLET, CADILLAC & GMC VEHICLES 2013-UP

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM. User s Manual

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

BrightSign Expander Hardware Guide

MANUAL FOR RX700 LR and NR

Unidirectional Transmitter/ Receiver Units Introduction

IP Box Camera ACM Ver Hardware User s Manual

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

FB-500A User s Manual

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

T3 Mux M13 Multiplexer

TDMoEthernet. Description

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Chapter 4 T1 Interface Card

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Transcription:

CFO400 Series User Manual CRT422 & CRR422 CFO422 User Manual, 59300059, rev002

Contents Introduction... 1 Video Transmitter CRT422 (version A)... 2 General... 2 Frame Installation... 2 Stand-Alone Installation... 2 Video Inputs and Indicator Leds... 2 Super Video Connection... 3 Data Connections... 4 Management (MGMT) Data Connection... 5 Audio Connection... 5 Contact Closure Loop (CCL) Connection... 5 Link Status and Module Indicator Leds... 6 Alarm Connections... 6 Video Source Alarm (VSA)... 7 Fibre Connection... 7 Video Receiver CRR422 (version A)... 8 General... 8 Frame Installation... 8 Stand-Alone Installation... 8 Video Outputs and Indicator Leds... 8 Data Connections... 9 Management (MGMT) Data Connection... 10 Audio Connection... 10 Contact Closure Loop (CCL) Connection... 10 Link Status and Module Indicator Leds... 11 Alarm Connections... 11 Video Source Alarm (VSA)... 12 Fibre Connection... 12 Copyright Acknowledgements... 13 CFO422 Series User Manual rev002

CFO422 Multimode 4 Channel Digital Units for Uni-directional Video, Bi-directional Data, Audio and CC, In-band Management Introduction The CFO422 is a four channel uni-directional video link with two bi-directional data, one audio and one contact closure channels. PAL, NTSC and SECAM video formats are supported to provide a transparent video transmission. It is also possible to transmit S-video channels (2 pcs) that comprises separate luminance (Y) and chrominance (C) signals. All common data protocols are supported as well and are easily configured by terminal software interface. Optical transmission is based on a FP laser operation. The multiplexed data stream of 540 Mb/s enables a full quality and a real-time video transmission in one multimode fiber up to 4...5 km typical transmission distance. All CFO422 units are compatible with all CFO rack systems. Stand-alone options are available with the CMA021 module adapter and a separate mains adapter. CRT422 Transmitter 4 x Video MGMT (RS232) MGMT (RS232) Audio (600 Ω/High) Audio (10 Ω) Data 1 (RS232) Data 1 (RS232) Data 2 (TTL/RS485/RS422) Data 2 (TTL/RS485/RS422) CC1 CC1/VSA bit rate 13.5 Mbps 1310 nm multimode optical fibre link budget 13 db bit rate 540 Mbps CRR422 Receiver 4 x Video MGMT (RS232) MGMT (RS232) Audio (10 Ω) Audio (600 Ω/High) Data 1 (RS232) Data 1 (RS232) Data 2 (TTL/RS485/RS422) Data 2 (TTL/RS485/RS422) CC1/VSA CC1 CFO422 Series User Manual rev002 1

OPTICAL TRANSMITTER CRT422 (version A) CAUTION: THIS OPTICAL UNIT USES CLASS 1 LASER DIODE. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. APPLICABLE STANDARD IEC825-2: 1993 1 2 VIDEO 1 Front view OPTICAL TRANSMITTER AUDIO GENERAL The CRT422 is a four channel optical transmitter for unidirectional video transmission with two bi-directional data, one audio and one contact closure channel in a multimode fibre. The current consumption is max. 800 ma (+12V DC). VIDEO 2 5 FRAME INSTALLATION 3 4 VIDEO 3 VIDEO 4 Picture 1. CRT422 Video Transmitter 1) Locking screw. 2) Video input (BNC female) and video indicator. 3) Optical output (ST). 4) Handle. 5) AUDIO connector 6) DATA / MGMT connector 7) Optical input (ST). DATA MODULE LINK STATUS 6 7 The module is to be pushed along the guide rails into the installation frame (e.g. CSR216 or 316 series) and secured with the four locking screws. The unit can be freely positioned in any slot in the frame. The empty positions in the frame should be blanked off with cover plates. The supply voltage is to be provided by a CPS384 power supply unit. STAND-ALONE INSTALLATION The unit can be installed for stand-alone use by using a CMA021 module adapter (see picture 2). The module should be mounted to a vertical surface. The 12V DC supply voltage is supplied by the means of a separate mains adapter with a regulated output, (e.g. CPS221). The permitted supply voltage range is 10.5...14V DC. The current consumption is 800 ma (max). The permitted operational temperature range is from 10...+55 C. VIDEO INPUTS AND INDICATOR LEDS The impedance of the video inputs (BNC female) is 75 Ω. The nominal input level is 1 Vpp. Each video input is equipped with the dual colour VIDEO led on the front panel. In case a video signal is present and in nominal level (and the unit detects video synchronization pulses), the VIDEO led is green. If there is no video signal, or the video level is too low, the VIDEO led is yellow. 2 CFO422 Series User Manual rev002

1 2 Rear view CONTROL BUS RF 2 1 CONTROL/ ALARM SUPER VIDEO CONNECTION It is also possible to transmit S-video signal that comprises separate luminance (Y) and chrominance (C) signals. This, however, uses two channels per one transmission channel as shown in picture 3 below. The video inputs are switched to S-video settings by DIP switches on the left-hand side of the unit (default factory setting is normal video). Note! The video LEDs on the front panel are locked to the synch pulse transmitted in the Y channels. POWER 3 + 12 V GND Y (ch 1) Picture 2. CMA021 Module Adapter 1) RJ-45 female connector, not in use. 2) Control / alarm interface connector 3) Supply voltage connector. Note! This DIP switch at rear connector is for factory use only. If this switch is set to "Reset" (lower position), the unit goes to "programming state" and then has no normal operation. Default factory setting is "Normal" (higher position). Switch exists in all units (CRT & CRR). Normal Reset Normal video Normal video Super video ch1 Super video ch2 C (ch 1) Y (ch 2) C (ch 2) Pin Signal 1-4 Not used 5 +12 V DC output 6 A - alarm 7 B - alarm 8 CTRL1 (cfo address bus data) 9 CTRL2 (cfo address bus clk) 10 No connection 11-15 Not used Table 1. Pin information for the HD15 female connector of the CMA021 module adapter. Picture 3. DIP switch settings for Super Video transmission. Note! No adjustments are needed on the receiver CRR422 for the S-video reception. CFO422 Series User Manual rev002 3

1 5 15 Picture 4. The DATA connector 6 11 DATA CONNECTIONS The DATA connector contais two bi-directional data channels (CRR <--> CRT). The connector in use is a HD15 female connector (see picture 4 and table 2 for detailed description). The recommended cable for DATA connection is CIC103 (HD15 female / open wires). Data channel 1 is always in RS232 mode. The desired data mode for data channel 2 can be selected by using a PC and any terminal type communication software (see separate documentation for CFO422 terminal software). The default factory settings are RS485-2 wire + Dwell time 75 µs. See table 3 for available data modes for data channel 2. Pin Signal TTL RS422 RS485 RS485-4w 1 Ch2 in (-) in/out (-) in (-) 7 Ch2 in in (+) in/out (+) in (+) 10 Ch2 out (-) out (-) 14 Ch2 out out (+) out (+) 4 Ch1 output (RS232) 5 Ch1 input (RS232) 3, 15 Ground Table 2. Data connector s pinout. Mode TTL RS422 RS485-2 wire RS485-4 wire Input termination options None No term (only failsafe) Hard bias Line bias (120 Ω line impedance) No term (only failsafe)+ Dwell time adjustable 50...10000µs Hard bias Line bias (120 Ω line impedance) No term (only failsafe) Hard bias Line bias (120 Ω line impedance) Table 3. Available datamodes for channel 2. 4 CFO422 Series User Manual rev002

1 Picture 5. The AUDIO/DATA connector (HD15 female) Pin Signal 2 MGMT output 3 Ground 12 MGMT input Table 4. MGMT connection s pinout Pin Signal 3 Ground 1, 11 Audio ground 4 Non-inverted input 5 Inverted input 10 Non-inverted output 14 Inverted output Table 5. AUDIO connector s pinout Table 6. CCL connection s pinout 6 11 5 15 Pin Signal 8 Contact closure output (+) 13 Contact closure output (-) 6 Contact closure input (+) 11 Contact closure input (-) MANAGEMENT (MGMT) DATA CONNECTION The DATA connector contains one bi-directional MGMT data channel (RS232). The management connection allows locally or remotely (CRT <--> CRR, bi-directional in-band connection via fibre) configuration and monitoring of CFO422 unit by using a PC and any terminal type communication software (see separate documentation for CFO422 terminal software). The connector in use is a HD15 female connector (see picture 5 and table 4 for detailed description). The recommended cable for terminal connection is CIC403 (HD15 female / D9 female, see table 7 for detailed description). Pin HD15 female D9 female 2 MGMT output MGMT input 3 Ground MGMT output 5 - Ground 12 MGMT input - Table 7. CIC403 cable s pinout (HD15 female / D9 female). AUDIO CONNECTION The AUDIO connector contains one bi-directional audio channel line (CRT <--> CRR). The audio input impedance can be set to high impedance (>10 kω) or 600 Ω with the terminal software (see separate documentation for CFO422 terminal software). The default factory setting is 600 Ω. The audio output impedance is constant and cannot be adjusted. The audio output impedance is 10 Ω. The connector in use is a HD15 female connector (see picture 5 and table 5 for detailed description). The recommended cable for AUDIO connection is CIC103 (HD15 female / open wires). CONTACT CLOSURE LOOP (CCL) CONNECTION The DATA connector contains one bi-directional contact closure channel line (CRR <--> CRT). The CCL input/output is TTL level voltage on/off - signal between connector s contact pins. The connector in use is a HD15 female connector (see picture 5 and table 6 for detailed description). The recommended cable for CCL connection is CIC103 (HD15 female / open wires). The CCL output channel can be alternatively configured for VSA usage (see page 7). The default factory setting is CCL usage (CC1=CC1). CFO422 Series User Manual rev002 5

LINK STATUS AND MODULE INDICATOR LEDS When the optical input signal level is adequate and in syncronisation to input data is achieved, the LINK STATUS led is green. If optical input signal level is adequate, but no syncronization is achieved the LINK STATUS led blinks green/yellow. If optical input signal is missing or it s level is too low, the the LINK STATUS led is yellow. When the supply voltage is not in the permitted range (10.5...14 V DC) or there is a transmitter laser failure, the MODULE led colour on the front panel is red. During normal operation MODULE led is blinking green (blinking indicates embedded software is working properly). ALARM CONNECTIONS All alarms at the rear connector of the unit are low open collector outputs,with the capability of 30 V/10 ma switching. Alarm Description Reason A Hardware failure TX Laser failure Supply voltage is not in the permitted range B Link status alarm Input optical signal too low No syncronisation archieved to input data Table 8. Open collector alarms. Note! At the rear of unit is located a DIP switch for factory use only (see picture 3). If this switch is set to "Reset" (lower position), the unit goes to "programming state" and then has no normal operation. Default factory setting is "Normal" (higher position). 6 CFO422 Series User Manual rev002

VIDEO SOURCE ALARM (VSA) The CCL output channel can be alternatively configured for VSA usage. When VSA mode is enabled and CRT s video input is missing (link otherwise operates normally, but e.g. only the camera is broken), the CCL output pins are closed. VSA have no effect to CRT s CCL input i.e. it can be used normally to transmit CCL information to CRR if VSA is not activated at CRR. In case when VSA is enabled at the same time in both CRT and CRR, then CCL channels are not available for other use. The VSA function can be set on/off by using a PC and any terminal type communication software (see separate documentation for CFO422 terminal software). The default factory setting is CCL usage (CC1=CC1). Note! Video detection has 20 sec delay before VIDEO SOURCE ALARM is activated / inactivated. FIBRE CONNECTION The optical connector is of the type ST. The optical output level is constant and cannot be adjusted. The nominal optical output level is 7 dbm (maximum optical input level for return signal is -1 dbm). The operating wavelenght is 1310 nm. When installing the fibre optic cable, do not exceed the minimum bending radius when connecting cable to the system. Note! For correct optical operation ensure that all optical connectors are cleaned immediately before mating. Connectors should always be cleaned using high purity alcohol (e.g. methyl or isopropyl alcohol). Dry the surfaces using clean compressed air or other equivalent pressurised gas. The optical connectors on the equipment should always be protected with dustcaps when there is no fibre inserted. CFO422 Series User Manual rev002 7

OPTICAL RECEIVER CRR422 (version A) CAUTION: THIS OPTICAL SYSTEM USES CLASS 1 LASER DIODE. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. APPLICABLE STANDARD IEC825-2: 1993 1 2 VIDEO 1 Front view OPTICAL RECEIVER AUDIO GENERAL The CRR422 is a four channel optical receiver for unidirectional video transmission with two bi-directional data, one audio and one contact closure channel in a multimode fibre. The current consumption is max. 800 ma (+12V DC). VIDEO 2 5 FRAME INSTALLATION 3 4 VIDEO 3 VIDEO 4 Picture 1. CRR422 Video Receiver 1) Locking screw. 2) Video output (BNC female) and video indicator. 3) Optical output (ST). 4) Handle. 5) AUDIO connector 6) DATA / MGMT connector 7) Optical input (ST). DATA MODULE LINK STATUS 6 7 The module is to be pushed along the guide rails into the installation frame (e.g. CSR216 or 316 series) and secured with the four locking screws. The unit can be freely positioned in any slot in the frame. The empty positions in the frame should be blanked off with cover plates. The supply voltage is to be provided by a CPS384 power supply unit. STAND-ALONE INSTALLATION The unit can be installed for stand-alone use by using a CMA021 module adapter (see picture 3). The module should be mounted to a vertical surface. The 12V DC supply voltage is supplied by the means of a separate mains adapter with a regulated output, (e.g. CPS221). The permitted supply voltage range is 10.5...14V DC. The current consumption is 800 ma (max). The permitted operational temperature range is from 10...+55 C. VIDEO OUTPUTS AND INDICATOR LEDS The impedance of the video outputs (BNC female) is 75 Ω. The nominal output level is 1 Vpp. Each video output is equipped with the dual colour VIDEO led on the front panel. In case a video signal is present and in nominal level (and the unit detects video synchronization pulses), the VIDEO led is green. If there is no video signal, or the video level is too low, the VIDEO led is yellow. 8 CFO422 Series User Manual rev002

5 1 6 15 11 Picture 2. The DATA connector Rear view DATA CONNECTIONS The DATA connector contais two bi-directional data channels (CRR <--> CRT). The connector in use is a HD15 female connector (see picture 2 and table 2 for detailed description). The recommended cable for DATA connection is CIC103 (HD15 female / open wires). Data channel 1 is always in RS232 mode. The desired data mode for data channel 2 can be selected by using a PC and any terminal type communication software (see separate documentation for CFO422 terminal software). The default factory settings are RS485-2 wire + Dwell time 75 µs. See table 3 for available data modes for data channel 2. 1 2 CONTROL BUS RF 2 1 CONTROL/ ALARM POWER Pin Signal TTL RS422 RS485 RS485-4w 1 Ch2 in (-) in/out (-) in (-) 7 Ch2 in in (+) in/out (+) in (+) 10 Ch2 out (-) out (-) 14 Ch2 out out (+) out (+) 4 Ch1 output (RS232) 5 Ch1 input (RS232) 3, 15 Ground Table 2. Data connector s pinout. 3 + 12 V GND Picture 3. CMA021 Module Adapter 1) RJ-45 female connector, not in use. 2) Control / alarm interface connector 3) Supply voltage connector. Pin Signal 1-4 Not used 5 +12 V DC output 6 A - alarm 7 B - alarm 8 CTRL1 (cfo address bus data) 9 CTRL2 (cfo address bus clk) 10 No connection 11-15 Not used Table 1. Pin information for the HD15 female connector of the CMA021 module adapter (with CRR422 installed). Mode TTL RS422 RS485-2 wire RS485-4 wire Table 3. Available datamodes for channel 2. Input termination options None No term (only failsafe) Hard bias Line bias (120 Ω line impedance) No term (only failsafe) Hard bias Line bias (120 Ω line impedance) No term (only failsafe) Hard bias Line bias (120 Ω line impedance) CFO422 Series User Manual rev002 9

1 Picture 4. The AUDIO/DATA connector (HD15 female) Pin Signal 2 MGMT output 3 Ground 12 MGMT input Table 4. MGMT connection s pinout Pin Signal 3 Ground 1, 11 Audio ground 4 Non-inverted input 5 Inverted input 10 Non-inverted output 14 Inverted output Table 5. AUDIO connector s pinout Table 6. CCL connection s pinout 6 11 5 15 Pin Signal 8 Contact closure output (+) 13 Contact closure output (-) 6 Contact closure input (+) 11 Contact closure input (-) MANAGEMENT (MGMT) DATA CONNECTION The DATA connector contains one bi-directional MGMT data channel (RS232). The management connection allows locally or remotely (CRT <--> CRR, bi-directional in-band connection via fibre) configuration and monitoring of CFO422 unit by using a PC and any terminal type communication software (see separate documentation for CFO422 terminal software). The connector in use is a HD15 female connector (see picture 4 and table 4 for detailed description). The recommended cable for terminal connection is CIC403 (HD15 female / D9 female, see table 7 for detailed description). Pin HD15 female D9 female 2 MGMT output MGMT input 3 Ground MGMT output 5 - Ground 12 MGMT input - Table 7. CIC403 cable s pinout (HD15 female / D9 female). AUDIO CONNECTION The AUDIO connector contains one bi-directional audio channel line (CRT <--> CRR). The audio input impedance can be set to high impedance (>10 kω) or 600 Ω with the terminal software (see separate documentation for CFO422 terminal software). The default factory setting is 600 Ω. The audio output impedance is constant and cannot be adjusted. The audio output impedance is 10 Ω. The connector in use is a HD15 female connector (see picture 4 and table 5 for detailed description). The recommended cable for AUDIO connection is CIC103 (HD15 female / open wires). CONTACT CLOSURE LOOP (CCL) CONNECTION The DATA connector contains one bi-directional contact closure channel line (CRR <--> CRT). The CCL input/output is TTL level voltage on/off - signal between connector s contact pins. The connector in use is a HD15 female connector (see picture 4 and table 6 for detailed description). The recommended cable for CCL connection is CIC103 (HD15 female / open wires). The CCL output channel can be alternatively configured for VSA usage (see page 12). The default factory setting is CCL usage (CC1=CC1). 10 CFO422 Series User Manual rev002

LINK STATUS AND MODULE INDICATOR LEDS When the optical input signal level is adequate and in syncronisation to input data is achieved, the LINK STATUS led is green. If optical input signal level is adequate, but no syncronization is achieved the LINK STATUS led blinks green/yellow. If optical input signal is missing or it s level is too low, the the LINK STATUS led is yellow. When the supply voltage is not in the permitted range (10.5...14 V DC) or there is a transmitter laser failure, the MODULE led colour on the front panel is red. During normal operation MODULE led is blinking green (blinking indicates embedded software is working properly). ALARM CONNECTION All alarms at the rear connector of the unit are low open collector outputs,with the capability of 30 V/10 ma switching. Alarm Description Reason A Hardware failure TX Laser failure Supply voltage is not in the permitted range B Link status alarm Input optical signal too low No syncronisation archieved to input data Table 8. Open collector alarms. Note! At the rear of unit is located a DIP switch for factory use only (see picture below). If this switch is set to "Reset" (lower position), the unit goes to "programming state" and then has no normal operation. Default factory setting is "Normal" (higher position). Note! This DIP switch at rear connector is for factory use only. If this switch is set to "Reset" (lower position), the unit goes to "programming state" and then has no normal operation. Default factory setting is "Normal" (higher position). Switch exists in all units (CRT & CRR). Normal Reset CFO422 Series User Manual rev002 11

VIDEO SOURCE ALARM (VSA) The CCL output channel can be alternatively configured for VSA usage. In CRR units the VSA is only monitored by the CRT s video input. When VSA mode is enabled and CRT s video input is missing (link otherwise operates normally, but e.g. only the camera is broken), the CCL output pins are closed. VSA have no effect to CRR s CCL input i.e. it can be used normally to transmit CCL information to CRT if VSA is not activated at CRT. In case when VSA is enabled at the same time in both CRT and CRR, then CCL channels are not available for other use. The VSA function can be set on/off by using a PC and any terminal type communication software (see separate documentation for CFO422 terminal software). The default factory setting is CCL usage (CC1=CC1). Note! Video detection has 20 sec delay before VIDEO SOURCE ALARM is activated / inactivated. FIBRE CONNECTION The optical connector is of the type ST. The maximum optical input level is -1 dbm (the nominal optical output level is 7 dbm). The operating wavelenght is 1310 nm. When installing the fibre optic cable, do not exceed the minimum bending radius when connecting cable to the system. Note! For correct optical operation ensure that all optical connectors are cleaned immediately before mating. Connectors should always be cleaned using high purity alcohol (e.g. methyl or isopropyl alcohol). Dry the surfaces using clean compressed air or other equivalent pressurised gas. The optical connectors on the equipment should always be protected with dustcaps when there is no fibre inserted. 12 CFO422 Series User Manual rev002

Copyright Acknowledgements Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation. Copyright Teleste Corporation. All Rights Reserved. No part of this document may be reproduced, transmitted, stored in a retrieval system, or translated into any other language without the express permission of Teleste Corporation. Teleste Corporation Video Networks P.O. Box 323 FIN-20101 Turku FINLAND www.teleste.com/cctv CFO422 Series User Manual rev002 13