SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

Similar documents
LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Diesel Engine Driven Generators Page 1 of 6

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Uninterruptible Power Supply

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Model #: SMART2200CRMXL

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Applications. Remote Display Mounting Kits

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Thyristor-controlled power supplies and battery chargers

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

EKOS Cart. Instructions for Use

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Liebert PPC Second Generation Power Distribution Cabinet

Specification Requirements DBL 700MX and 1000MX Series UPS

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Specifying a Variable Frequency Drive s

TMS TANK MANAGEMENT SYSTEM

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Power Supplies 3. SDN-P DIN Rail Series

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Fire Pump Controllers Remote Alarm Panels

BC Pro UPS System Standby UPS System

User s Manual AURORA 1.2K/2.2K

32VFD Variable Frequency Drives for Centrifugal Chillers

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Internet Office UPS System Standby UPS for PCs, workstations and more

Online UPS. PowerWalker VFI 1000R/1U

Re-defining the utility-scale inverter

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

IntesisBox KNX Mitsubishi Heavy Industries AC

Back-UPS Pro 1300/1500 Installation and Operation

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

Technical Data. back-up time in minutes 100% load % load

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

How To Use A Power Supply Unit (Upu)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

TOSHIBA G /100/160/225 kva

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Specification CyberWave UPS Ver /01/00

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Secondary Unit Substations

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

MAJORSINE Power Inverter

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Single Phase, (3 to 20KVA) & (3 to 15 KW) Harsh Environment Outdoor Application NEMA 3R Cabinet

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Voltage Tolerance Boundary

Installation and Operation Back-UPS 1250, 1300, 1500

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Fronius IG Plus. The next generation grid-connected PV inverter

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Low Voltage Products

SECTION DETECTION AND ALARM

Safety technique. Emergency stop module BO 5988 safemaster

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Internet Office 500VA Tower Standby 120V UPS with USB port

WINGLIKE ELECTRONICS CO.,LTD

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Phase Modular Finally the benefits of Modular ups are for all

Transcription:

Utility Systems Technologies, Inc. P.O. Box 110 Latham, NY 12110 SagFighter Active Voltage Conditioner / Sag Ride Through (SRT) Overview The Sag Fighter is an industrial-grade, solid state, electronic voltage sag corrector/active voltage conditioner that operates without batteries or energy storage. Industrial-grade means the Sag Fighter is compatible with all non-regenerative load types and load power factors and provides a minimum 1,000% fault-clearing capability. Unlike computer-grade products or uninterruptible power supplies (UPS), the Sag Fighter is designed for frequent high-inrush current and lowpower factor loads without the need to over-size the product. The Sag Fighter provides the following features: Sag protection compliant with SEMI-F47 Full sag correction within 2 milliseconds Sag correction duration independent of load or power factor Sag correction for a minimum of 100 seconds No need for bypass operation for high inrush or overload currents Continuous protection without the need to recharge or reset Non-continuous inverter operation that increases reliability and provides 99% efficiency Battery-free design 1

The Sag Fighter consists of a three-phase transformer with each of its secondary windings connected in series between the source (incoming line) and the load(s). Load current flows through the secondary windings of the transformer while the unit operates in a monitoring mode with the primary transformer windings shorted through SRC switches. The Sag Fighter continuously monitors the input voltage waveform for any deviation from a balanced, three-phase voltage. Upon sensing a deviation, the Sag Fighter engages an inverter circuit to apply an injection voltage to the primary windings of the series-connected transformer. The injection voltage is synthesized with a magnitude, shape, and phase angle so that when it is added in series with the incoming voltage, a balanced, three-phase voltage results. When normal, three-phase incoming voltage is detected at the Sag Fighter input, the inverter circuit is disengaged and the unit returns to monitoring mode. The Sag Fighter is thermally ranged to provide continuous correction for a voltage sag, although this is not normally required. The Sag Fighter uses natural convection cooling and has no fans or other moving parts. Larger units may include heat-sink fans that operate only when the unit is correcting a sag event. An automatic electronic failsafe bypass is incorporated into the standard design so the Sag Fighter maintains power to the load if a unit malfunctions. The Sag Fighter automatically corrects voltage sags with no operator or programming required. The unit display provides unit status and historical information on sag correction events. Alarm contacts are also provided to permit remote indication of Sag Fighter status. Sag Fighter installation is simple. The unit arrives completely assembled and requires no programming, testing, measuring or setting of switches. It is designed to install much like a dry-type transformer: simply place the unit and make input and output wiring connections. The Sag Fighter typically has no maintenance schedule other than routine inspection and cleaning. 2

Specifications Application Power Rating/Size (kva) Phase - Frequency (Hz) 100, 125, 150, 200, 250, 300, 350, 400, 500, 750, 1,000, 1,250, 1,500, 1,750, 2,000 kva 3Ø, 50 or 60 Hz Standard Input/Output Voltages 60 Hz: 208, 240, 480, 600 50 Hz: 220, 380, 400, 415 (non-standard voltages available) Sag Correction/Operating Characteristics 1- or 2-phase sags to 30% remaining voltage (-70% sag) corrected to at least 95% of Sag Correction nominal voltage. 3-phase sags to 60% remaining voltage (-40% sag) corrected to at least 95% of nominal voltage. Nominal voltage ±5% during sag correction [Note: unit normally operates in monitoring Output Regulation mode until voltage reaches 90% of nominal voltage, at which time sag correction is initiated] Response Time Correction Duration Regulation Variation Phase Shift Correction Harmonic Distortion Overload/Inrush Capability Load / Power Factor Efficiency Operating Frequency Full sag correction typically within 2ms, regardless of load or load power factor. Sags corrected for a minimum of 100 seconds, regardless of load or power factor. None: regulation constant for 0 to 100% load and any load power factor. Phase shifts are corrected automatically during sag correction. None: added in monitoring mode. 1,000 % - 1 second, 500% - 5 seconds, 200% - 1 min.; 1,000% fault clearing No minimum or part load or load-power factor limitations; compatible with all load types. 99% typical +/- 3% from nominal frequency (50Hz or 60Hz) Performance specifications are based on the input (source) voltage meeting IEEE 519 Operating Environment standards. Noise Suppression/Load Protection Surge Suppression Included, complies with ANSI/IEEE C62.41, UL 1449 Input Circuit Breaker Included, standard, UL 489, ANSI/IEEE C22.2 Failsafe Electronic Bypass Construction Technology Transformer Inverter Operation Cooling Cabling/Connections Audible Sound Level Display Controls Monitoring Environmental Requirements Temperature - Humidity Operating Altitude Auto-actuation on high temperature, over-current, component failure with no loss of load Microprocessor-controlled, inverter-based series voltage injection Copper-wound, dry-type series transformer (3W+G input and output) Non-continuous operation only during sag correction Natural convection cooled with heat-sink fans used only during sag correction [contaminant free, dry, clean air] Floor-mounted NEMA-1, ANSI 61 grey. Custom enclosures also available contact factory. See enclosure drawing for cable entry/exit options and circuit breaker/lug size table. Less than 65dB @ 1 meter Touch-screen display with event history recorder, operational data, and utilities No controls or programming required, no user-adjustable controls Contacts for remote indication of unit and surge suppression status are included. Ambient 32 to 104 F (0 to 40 C) Relative humidity 0-95% non-condensing 0 to 10,000 ft (3000m) 3

Options Option Code Description 50 Hz 5 Required to identify 50Hz units - standard units are 60Hz Power Monitor with ModBus Communications Non-Standard C E Local, push-button digital display of amps, volts, power factor, Power. For input and/or output. Per customer specification. Contact factory for further details. Mechanical bypass M An open transition bypass to power load while isolating the SagFighter for inspection or maintenance. The standard SagFighter includes an automatic failsafe internal bypass to maintain power to the load in the event of a malfunction and may operate indefinitely on this internal bypass. The internal bypass will be supplied even if the mechanical bypass option is selected. Non-Standard Voltages N For any non-standard input or output voltage Wiring Labels L Undefined Options (custom) Q Option designed to meet specific customer requirement 4

Weights and Dimensions kva Height Width Depth Weight - 60Hz Weight - 50Hz Lbs. (kg) Lbs. (kg) 100 46 (117) 36 (91) 28 (71) 1000 (455) 500 S36 125 65 (165) 44 (112) 33 (84) 1150 (523) 575 S44 150 65 (165) 44 (112) 33 (84) 1300 (591) 650 S44 200 65 (165) 44 (112) 33 (84) 1600 (727) 800 S44 250 65 (165) 44 (112) 33 (84) 2000 (909) 1,000 S44 300 80 (203) 56 (142) 40 (102) 2400 (1091) 1,200 S56 350 80 (203) 56 (142) 40 (102) 2800 (1273) 1,400 S56 400 80 (203) 72 (183) 48 (122) 3500 (1591) 1,909 S72 500 80 (203) 72 (183) 48 (122) 4500 (2045) 2,455 S72 600 80 (203) 72 (183) 48 (122) 5500 (2500) 3,000 S72 750 80 (203) 85 (216) 66 (168) 6500 (2955) 3,250 S85 1,000 80 (203) 85 (216) 66 (168) 8500 (3864) 4,250 S85 1,250 80 (203) 85 (216) 66 (168) 10000 (4545) 5,000 S85 1,500 80 (203) 96 (244) 78 (198) 11000 (5000) 5,500 S96 1,750 80 (203) 120 (305) 78 (198) 12000 (5455) 6,000 S120 2,000 80 (203) 120 (305) 78 (198) 13000 (5909) 6,500 S120 * Weights and dimensions for standard units. Certain options may require a larger enclosure or increase the weight. Contact factory for details Utility Systems Technologies, Inc. P.O. Box 110, Latham, NY 12110 Phone: 888-403-9084 Fax: 518-377-2207 Email: sales@ustpower.com Web: ustpower.com 5