Calculation of total measurement uncertainty

Similar documents
Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Automatic compression measurement using network analyzers

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

F = S i /N i S o /N o

Application Note Noise Frequently Asked Questions

Optimizing IP3 and ACPR Measurements

A Guide to Calibrating Your Spectrum Analyzer

Impedance 50 (75 connectors via adapters)

Understanding Mixers Terms Defined, and Measuring Performance

Propagation Channel Emulator ECP_V3

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

RF Level Measurement Uncertainties with the Measuring Receiver R&S FSMR

Visual System Simulator White Paper

Field Calibration Software

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

Network Analyzer Operation

R&S ZNBT8 Vector Network Analyzer Specifications

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

MATRIX TECHNICAL NOTES

Fast and Accurate Test of Mobile Phone Boards

Michael Hiebel. Fundamentals of Vector Network Analysis

GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

Conquering Noise for Accurate RF and Microwave Signal Measurements. Presented by: Ernie Jackson

R&S ZNC Vector Network Analyzer Specifications

Power Amplifier Gain Compression Measurements

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal.

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

Calculating Antenna System Return Loss As Viewed Through The RF Path

TCOM 370 NOTES 99-4 BANDWIDTH, FREQUENCY RESPONSE, AND CAPACITY OF COMMUNICATION LINKS

Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Network analyzer and spectrum analyzer two in one

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

RECOMMENDATION ITU-R BS.704 *, ** Characteristics of FM sound broadcasting reference receivers for planning purposes

DSA800 Series Spectrum Analyzer

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

Audio processing and ALC in the FT-897D

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

RF Communication System. EE 172 Systems Group Presentation

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

RECOMMENDATION ITU-R SM Measuring sideband emissions of T-DAB and DVB-T transmitters for monitoring purposes

Introduction to Receivers

AM/FM/ϕM Measurement Demodulator FS-K7

One Port Network Analyzer

Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview

HD Radio FM Transmission System Specifications Rev. F August 24, 2011

Interpreting the Information Element C/I

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

R&S SMZ Frequency Multiplier Specifications

Measurement, analysis, and monitoring of RF signals

HF Receiver Testing. Issues & Advances. (also presented at APDXC 2014, Osaka, Japan, November 2014)

A Network Analyzer For Active Components

The Calculation of G rms

Experiment 7: Familiarization with the Network Analyzer

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Keysight Technologies Understanding the Fundamental Principles of Vector Network Analysis. Application Note

EE4367 Telecom. Switching & Transmission. Prof. Murat Torlak

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

GSM frequency planning

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

R&S ZVA Vector Network Analyzer Specifications

DVT913 TV CHANNEL CONVERTER

The Phase Modulator In NBFM Voice Communication Systems

Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

How to avoid typical pitfalls when measuring Variable Frequency Drives

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Implementation of Digital Signal Processing: Some Background on GFSK Modulation

Fig 1a: Two-tone signal at the input of mixer. Fig 1b: Signals at the output of mixer

Realtime FFT processing in Rohde & Schwarz receivers

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

iva Cable & Antenna Analyzer

R&S ZVL Vector Network Analyzer Specifications

1 Multi-channel frequency division multiplex frequency modulation (FDM-FM) emissions

RF-Microwaves formulas - 1-port systems

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

Cable Impedance and Structural Return Loss Measurement Methodologies

Improving Network Analyzer Measurements of Frequency-translating Devices Application Note

Analysis/resynthesis with the short time Fourier transform

Robot Perception Continued

Antenna Deployment Technical Brief

khz to 2.7 GHz Spectrum Analyzer

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

Understanding Power Splitters

Algebra 1 Course Title

'Possibilities and Limitations in Software Defined Radio Design.

How To Use A Sound Card With A Subsonic Sound Card

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

APPLICATION NOTES: Dimming InGaN LED

Welcome. Rulon VanDyke RF System Architect, Agilent Technologies. David Leiss Senior RF Simulation Consultant, Agilent Technologies

Agilent E6832A W-CDMA Calibration Application

Characterizing Digital Cameras with the Photon Transfer Curve

Transcription:

Fundamentals of Spectrum Analysis 5.10. Calculation of total measurement uncertainty Error sources contributing to the total measurement uncertainty depend on the type of measurement. In the following sections, error sources encountered in frequency measurement applications are described. Measurement of absolute level If the absolute level of a sinusoidal signal is to be measured, the following factors usually contribute to the total measurement uncertainty: Absolute level error Frequency response (only if the signal frequency distinctly differs from the frequency of the internal calibration source) Attenuator error (only if the attenuator setting differs from that specified in the data sheet for the absolute error) IF gain error (only if the set reference level differs from that specified in the data sheet for the absolute error) Linearity error The linearity error to be taken into account depends on the spacing of the input signal from the reference level. Bandwidth switching error (only if the set bandwidth differs from that specified in the data sheet for the absolute error) An additional bandwidth error has to be taken into account in noise or channel power measurements. Relative level measurement The following error contributions have to be taken into account when measuring the level difference between two sinusoidal signals. 156

Performance Practical Features Realization of Spectrum of an Analyzers Frequency response (only if the signal frequency strongly varies between the individual measurements) Attenuator error If the attenuator setting is not varied during measurement, this error can be ignored. IF gain error If the reference level is not varied during measurement, this error can be ignored. Linearity error Bandwidth switching error If the bandwidth is not varied during measurement, this error can be ignored. An additional bandwidth error has to be taken into account in noise or channel power measurements if the resolution bandwidth is varied between the measurements. Resolution bandwidth, attenuator setting (RF attenuation) and reference level should not be varied during the measurement in order to minimize the error of relative level measurement. Only the linearity error and frequency response, if applicable, will then contribute to the total measurement uncertainty. Table 5- shows the error contributions that have to be considered in a number of typical measurements. The maximum error (worst case error) can be calculated from the individual contributions simply by adding the relevant parameters. The calculated maximum error has a confidence level of 100% so that the actual error of a measurement never exceeds the calculated error limits. In practice, however, the maximum error seldom occurs. If the total uncertainty is the sum of many individual errors stemming from completely independent sources, it is statistically a very rare event that all individual errors occur in a measurement simultaniously at their maximum value and same sign. 157

Fundamentals of Spectrum Analysis Measurement Absolute Harm- rd order rd order Channel Adjacent- Power versus Phase noise, far Phase noise, level of onic intermodulation intercept power channel time (e.g. for off carrier, with close to carrier CW signal distor- products power TDMA variation of RF tion (close to carrier) ratio signals), attenuation and relative reference level Error contribution Absolute error Frequency response Attenuator error IF gain error Linearity error Bandwidth switching error Bandwidth error Error due to limited number of samples Mismatch error Table 5- Error contributions in typical measurements using a spectrum analyzer 158

Performance Practical Features Realization of Spectrum of an Analyzers It is more realistic to calculate the total uncertainty with a certain confidence level, which is typically 95% or 99%. Such calculation is permissible if the total uncertainty is composed of several error contributions of equal magnitude. The distribution of the individual error contributions depends on the type of error. The following discussions are based on [5-5]. For random errors, that is for all errors listed above with the exception of mismatch errors, a rectangular distribution is assumed. The variance σ of the individual errors is given by: σ = a (Equation 5-49) where σ = variance a = max. systematic error, in db If the data sheet specification of the level error is not given as worst case but with a certain confidence level, the variance has to be calculated from this value first. The following applies: σ = ( a CL k ) (Equation 5-50) where σ = variance a CL = specified error with certain confidence level or standard uncertainty, in db The value of k depends on the confidence level of the value specified in the data sheet. The following applies: ( ) CL k = erfinv (Equation 5-51) 100 where erfinv = inverse error function CL = confidence level, in % Fig. 5-7 shows k as a function of the confidence level. For a confidence level of 95%, k assumes a value of 1.96, and for 99%, a value of.58. 159

Fundamentals of Spectrum Analysis Factor k 4.5.5 1.5 Factor k 4.5.5 k =.58 1 0.5 k = 1.96 0 0 10 0 0 40 50 60 70 80 90 100 a) Confidence level / % 91 9 9 94 95 96 97 98 99 100 Fig. 5-7 Coverage factor k as a function of confidence level a) confidence level 0% to 100%, b) confidence level 90% to 100% (zoomed) 1.5 90 b) Confidence level / % In some cases the standard uncertainty s is specified in addition to the level error. This makes the calculation according to equation 5-50 unnecessary. The variance can be calculated from the specified standard uncertainty simply by squaring it. Bandwidth errors are usually specified as a percentage. The following applies: ( ) { 10 log 1 + RBW / % } σ 100 = where σ = variance RBW = bandwidth error, in % (Equation 5-5) Errors due to mismatch have a U-shape distribution. The variance σ is given by s { ( s 1 s l 1 )} {0 log(1 r s r l )} 0 log 1 σ s +1 s +1 = s l = (Equation 5-5) where σ = variance r s = magnitude of source reflection coefficient r l = magnitude of spectrum analyzer reflection coefficient s s = VSWR of source s l = VSWR of spectrum analyzer The reflection coefficient can be calculated from Equation 5-47. 160

Performance Practical Features Realization of Spectrum of an Analyzers Error Absolute level error Frequency response Attenuator error IF gain error Linearity error Bandwidth switching error Bandwidth error Mismatch error Calculation of variance σ = σ = σ = { a and 10 log 1 + ( RBW / % ) } 100 {0 log(1 r s r l )} Equation 5-49 and Equation 5-50 Equation 5-5 Equation 5-5 Table 5- Calculating the variance of specified error contributions The combined standard uncertainty σ tot can be calculated from the variances σ i of the individual contributions as follows: σ tot = σ 1 + σ +... + σ n (Equation 5-54) It has a confidence level of 68% (Fig. 5-7a). To maintain the error at some other confidence level, σ tot tot has to be multiplied by a factor k which can be derived from Fig. 5.7. For a confidence level of 95%, k = 1.96 and for 99%, k =.58. Example: For the absolute level measurement of a sinusoidal input signal of 1 GHz (output VSWR of signal source 1.:1), the total measurement uncertainty is to be determined with a confidence level of 95%. The resolution bandwidth set on the spectrum analyzer is 0 khz, the RF attenuation is 0 db and the reference level 0 dbm. The signal level is about 0 db below the reference level. 161

Fundamentals of Spectrum Analysis Which errors contribute to the total measurement uncertainty? Absolute error Frequency response Attenuator error IF gain error Linearity error Bandwidth switching error Since the input is a sinusoidal signal, the bandwidth error does not affect the total measurement uncertainty. The required data are taken from the spectrum analyzer data sheet: Specified error Variance σ i Absolute error 0. db 1. 10 Frequency response 0.5 db 8. 10 Attenuator error 0. db 1. 10 IF gain error 0. db 1. 10 Linearity error 0. db 1. 10 Bandwidth switching error 0.1 db 1. 10 Mismatch error VSWR at spectrum analyzer input 1.5 VSWR at signal source output 1. 1.7 10 The combined standard uncertainty can be calculated from the variances σ i with the aid of Equation 5-54 to yield σ tot =0.9. The total measurement error of 0.76 db is obtained at a confidence level of 95% by multiplying the standard uncertainty by a factor of 1.96. To simplify such error calculations, a spreadsheet in MS Excel 5.0 is available (file FSP_ERR.XLS, Fig. 5-8) which can be obtained via the R&S Web site (www.rohde-schwarz.com). 16

Performance Practical Features Realization of Spectrum of an Analyzers 1 4 5 6 7 8 Fig. 5-8 Spreadsheet FSP_ERR.XLS Legend for spreadsheet FSP_ERR.XLS All input fields in the table are highlighted yellow. The fields for intermediate results and the resulting total level are highlighted in light and dark blue. 1You can choose whether the values entered in () are absolute error limits (worst case) or a standard uncertainty. Input fields for specified errors. Output of the variances calculated from the input values. 4You can choose whether the error entered under () is to be taken into account in calculating the total error. Error contributions can thus very easily be ignored without having to set the value entered under () to zero. 5Output of the calculated total error with a confidence level of 95% or 99%. Errors due to mismatch are not considered in this result. 6You can choose whether the mismatch of the DUT or spectrum analyzer is entered as VSWR (v) or as return loss (a). 7Input field for specified maximum mismatch of the DUT or spectrum analyzer. 8Output of the calculated total error with a confidence level of 95% or 99%. All error sources are considered in the result. 16