MASTERCALL DIAL-UP PA INTERFACE

Similar documents
Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Digital Keypad Use s Manual

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

AC-115 Compact Networked Single Door Controller. Installation and User Manual

ACTIVE 5 ENGINEERING MANUAL

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

How To Program An Autodialer

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

PagePac PAGEPAL V

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

AUTODIALLER / QUICKDIALLER - SA132

Emergency Dialer DIAL-ALERT MODEL: AD

Automatic Telephone Dialer TD-101(W)

Model PBX 206 System User Guide

GSM Autodialer Professional GJD700 Speech & Text Autodialer

User manual Rev 1.3 Contents

DC-8706K Auto Dial Alarm System

Features, Benefits, and Operation

GSM Voice Auto Dialer & SMS Sender JC-999

K-2000-DVA See at a Glance when Lines are Multi-Input Ringing Voice. Telecommunication Peripheral Products. Technical Practice

Auto Dialer. Manual E-921APQ E-921GPQ

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.

System Administration Guide. Model KS 832. Expandable up to 1664

TCR easy Plus Alarm. Operating Instructions

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Temperature & Humidity SMS Alert Controller

Innovative PABX Accessories. for Any PABX System

Art.275 PABX Interface

Add Door Phones to Your Phone System

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ACCESS CONTROL DOOR PHONES Installation and Programming Manual

TS510 & TS500. Installation & User Guide. Compatible Equipment

Innovative DOOR STATION Solutions

V-9970 SINGLE ZONE ONE-WAY STATION LEVEL PAGE CONTROL

Advantium 2 Plus Alarm

Operating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel

Secure Keypads for access control

Enterprise Telephone. Model OPERATING INSTRUCTIONS

SMART SENSOR COLLECTION

AD-01 Slave Auto Dialer. Owner s Manual

Business/Home GSM Alarm System. Installation and User Manual

GSM Desktop phone DPH101. User manual v1.00

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

Installation Manual for D0700 ISDN Analogue Converter

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

Operating Instructions. UL325 Compliant Non-monitored

Model PBX 308 Plus System Administration Guide

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

GSM1000 The Orchid Mobile Gateway. Benefits & Feature List

FIREDEX Conventional Fire Panels

In addition to our VoiceDirector hardware products, the following SIP broadband devices are also compatible with VoiceDirector:

VOIP-500 Series Phone Quick Installation Guide

PS 155 WIRELESS INTERCOM USER MANUAL

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Enterphone Solo. User/Installation Manual Part No

Magnetic proximity switches

FSLIMRF

Home Security Alarm System

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

GSM Alarm System User Manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Model PBX 308 System Administration Guide

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

User Manual for CH-PFC76810

FIRERAY 2000 Installation Guide

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog.

PCM2000 Configuration Guide

NOKIA 32 SUPPORT GUIDE FOR INSTALLING NOKIA 32

Memcom Emergency Telephone

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

FWT-8848 GSM (GATEWAY) USER S MANUAL

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

Duct Humidity Transmitter

Control/Communicator Installation Manual

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

Magnum Mobile Generator MMG55 Specifications

Water Leak Detection System

Pancode VoIP/Pantel VoIP Access Control Door Phones. Installation and Programming Manual Release 1.0 June 2006

Model PBX 308 Plus System Administration Guide

Model PBX 416 Plus System Administration Guide

Transcription:

MASTERCALL DIAL-UP PA INTERFACE MD-4900PA WITH AUTOMATIC DISCONNECT ISOLATED VERSION SERIAL/ITEM 533/nnn USER GUIDE Issue 5, JULY, 2013, AUTHOR: PETER ZEUG DESIGNED AND MANUFACTURED IN AUSTRALIA Est. 1968 www.design2000.com.au DESIGN TWO THOUSAND PTY LTD ACMA SUPPLIER CODE NUMBER N468 DESIGN TWO THOUSAND IS CERTIFIED TO ISO9001 MADE IN AUSTRALIA User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5

User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5

MASTERCALL MD-4900PA DIAL-UP PA INTERFACE USER GUIDE CONTENTS PAGE Introduction 1 Connections 2 Wiring Diagram For Door Latch & Output Mode 3 Unit wall mounting option 4 User Instructions 5 To Make an Announcement over the PA 5 Siren Alert Tone 5 Busy Tone Disconnect Counter 5 Automatic Disconnect 5 Dial (Long) Tone Disconnect 5 Force Disconnect 6 Silence Disconnect 6 Speaker Volume 6 Busy Tone Detect Selection 7 Specifications 8 Packing List 10 N468 DESIGNED AND MADE IN AUSTRALIA Est. 1968 DESIGN TWO THOUSAND PTY LTD TELEPHONE: (03) 9758 5933 FAX: (03) 9758 5560 E-MAIL: gen@design2000.com.au Copyright 2013, Design 2000 Pty Ltd. All Rights Reserved. User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5

MASTERCALL PA INTERFACE MD-4900PA DIAL-UP WITH AUTOMATIC DISCONNECT INTRODUCTION The Mastercall Dial-up PA Interface, with an inbuilt line-powered pre-amplifier, interfaces a standard telephone line or analog PABX extension to a line-level input of a Public Address amplifier. It allows people to make PA announcements from any telephone simply by dialing the PA extension number. An alert tone sounds over the PA just before the announcement is due. This system is fully ACMA compliant and isolates the telephone line from the PA system. The MD-4900 has an inbuilt microprocessor controlled busy tone and disconnect tone detector so that calls to the PA disconnect virtually the moment the caller hangs up. User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 1

CONNECTING THE MD-4900 HIDE-AWAY UNIT TO THE PA AND TELEPHONE LINE OUTPUT TO P.A. POWER 12V DC (IF REQUIRED) TELEPHONE LINE DOOR OPENER / ALARM CONNECTOR 1ALARM 2ALARM 3DOOR - 4DOOR + 1 4 1 3 RELAY CONNECTOR 1NC 2NO 3COM 1. Connection to the PA is made via pins 7 & 8 of the RJ45 PA connector. RJ45 plug Pin 1. Not used (Pin 1 of RJ45 connector) --------------- 1 2. Not used (Pin 2 of RJ45 connector) --------------- 2 3. Not used (Pin 3 of RJ45 connector) --------------- 3 4. Not used (Pin 4 of RJ45 connector) ---------- 4 5. Not used (Pin 5 of RJ45 connector) ---------- 5 6. Not used (Pin 6 of RJ45 connector) ---------- 6 7. To PA shield & cold (Pin 7 of RJ45 connector) --------------- 7 8. To PA hot/conductor (Pin 8 of RJ45 connector) --------------- 8 2. Connection to the telephone line is made via pins 3 & 4 of the RJ12 Telephone Line connector. RJ12 plug Pin 1. Not Used Pin 1 of RJ12 connector --------------- 1 2. Not Used Pin 2 of RJ12 connector --------------- 2 3. Line side a Pin 3 of RJ12 connector ---------- 3 4. Line side b Pin 4 of RJ12 connector ---------- 4 5. Not Used Pin 5 of RJ12 connector ---------- 5 6. Not used Pin 6 of RJ12 connector --------------- 6 3. The relay output can be used to switch other devices. In the default setting, the relay operates whenever the phone line is looped (seized). User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 2

WIRING DIAGRAM FOR DOOR LATCH & SWITCHED OUTPUT MODE PLEASE CONSULT YOUR DISTRIBUTOR FOR FULL DETAILS PIN 4 DOOR+ HIDE-AWAY UNIT POWER SUPPLY FOR DC DOOR STRIKE + 10-30 V DC 2 Amps MAX PIN 3 DOOR- + +VE - -VE Open Collector Switch & Isolation Circuit ELECTRIC DOOR STRIKE Switched Output Mode The door latch switched output (open collector) and voltage free relay contact can be programmed to operate only when *5 is pressed by the person on the phone. (Please note that the voltage free relay contact requires external isolated 12Vdc, 350mA nominal power. Use only a transformer type plug pack. DO NOT use a switch mode supply as this introduce noise and hum on the line). The open collector and relay contact can also operate when the line is seized on a PA call. This mode can be used to operate the PA etc.. 1. Dial up the MD-4900. 2. Wait for it to answer with a double pip tone. 3. Press * 601. 4. Press 0 for both switched outputs to be activated only by DTMF *5, OR: Press 1 for both switched outputs to be activated when an external input triggers an outgoing call (DTMF *5 still works for activating the output on incoming calls), OR: Press 2 for the relay to be activated when an external input triggers an outgoing call, and the transistor output (DOOR +, DOOR -) to be activated only by DTMF *5, OR: Press 3 for the relay to operate when an incoming call is received and the phone line is looped (default for the MD-4900 PA version). 5. Press # to store the setting. Summary: <* [PIN] 601 [0, 1, 2 or 3] #> User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 3

HIDE-AWAY UNIT WALL MOUNTING OPTION 110 mm 215 mm 20mm 1 Disconnect all wiring from Hide-away unit. 2. 3 4 5 Drill holes for mounting screw as shown in diagram. Fit mounting screw to mounting surface and check that screw does not protrude more than 7mm from surface Locate Hide-away unit onto mounting screw. Connect wiring to Hide-away unit. NOTE: SCREW HEIGHT FROM MOUNTING SURFACE MUST NOT EXCEED 8mm (5/16 ) User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 4

USER INSTRUCTIONS To Make an Announcement Over the PA 1. Dial the PA extension (or press the PA speed dial button), wait for the double pip tone, make your announcement and hang up. Siren Alert Tone (Emergency Services version only with SW-9942602 or later) 1. While talking over the PA, simply press *5 to sound the alert siren. 2. When the siren stops, continue talking or hang up. Automatic Disconnect The MD-4900 will disconnect the telephone line if: One or two busy tones are detected. DTMF *9 is detected. Loop current loss or line reversal is detected Silence time has elapsed. Busy Tone Disconnect The MD-4900 will disconnect after a programmable number of consecutive valid busy tone on/off periods. Please note that a valid off period is included in the counter. 1. Dial up the Mastercall unit and wait for it to answer with a double pip tone. 2. Press * 606. 3. Enter the number of busy tone on/off periods for automatic disconnection (range 1-8, default = 2). If you enter 2, you will hear one (or perhaps two) busy tones over the PA when you hang up. 4. Press # to store the setting. Summary <* [PIN] 606 b#>, where b = 1 8 (default = 2) Dial (Long) Tone Disconnect Some telephone systems provide dial tone or long tones as the disconnect signal. The MD-4900 may be programmed to disconnect after 1 second to 255 seconds of continuous tone (two seconds minimum is recommended). Summary <* [PIN] 603 t #>, where t = 1 255 (or 0 = off) seconds. (ie. enter a value of the seconds required or enter 0 to turn this feature off). User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 5

Force Disconnect 1. While talking over the PA, simply press *9 Silence Disconnect 1. Dial up the Mastercall unit and wait for it to answer with a double pip tone. 2. Press * 8. 3. Enter the maximum number of seconds of silence detection on the LINE side for a PA call to be automatically disconnected (0 = no silence disconnect or 1 255 seconds). Eg. if you enter 30 seconds, any call with a silence period (on the line side) of thirty seconds or more will be automatically disconnected. 4. Press # to store the setting. Summary: <* [PIN] 8 s #> How to Change the Speaker Volume 1. While talking over the PA, simply press *3 to turn up the volume or *4 to turn down the volume. 2. Repeat step 1 as required, then just hang up to save changes. Summary: <* 3 (up by 2dB) or * 4 (down by 2dB)> User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 6

BUSY TONE DETECT SELECTION Brief IP based telephone switches and VoIP analogue terminal adaptors can provide either North American busy tone or Australian busy tone. All MD-4900 Series units can be set to detect either US or AUS (default) busy tones for automatic disconnect. Instructions Remove the MD-4900 hideaway unit cover: Locate LK2 - the three pin US_AUS jumper link circled below in red: Position the shunt in either the US or AUS position. Test for reliable busy tone disconnect and replace cover. User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 7

SPECIFICATIONS Enclosure Powder coated steel. Dimensions Hide-away Unit 215 mm x 105 mm x 35 mm. Power Requirement Telephone line powered. Power Consumption 50 µa nom. in stand-by mode. 15 ma nom. during line seize. Operating Temperature Range -10 +50 C. Storage Temperature Range -20 80 C ambient. Humidity, Storage and Operating To 98% non condensing. Mean Time Between Failure > 20 years. Speakerphone pre-amplifier Motorola MC33218AP half duplex. Output level -13.5 0 dbm adjustable. Frequency range 300 Hz 3.4 khz. Line Interface Two wire analogue ring in loop out. Programming method DTMF Push buttons (Hide-away unit) 12 button silicone membrane (Optional). Displays Off hook dialer LED, Tone detect LED. ACMA Supplier s Code Number N468 Warranty Two years. Note: Specifications are subject to change without notice. User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 8

MASTERCALL PA INTERFACE MD-4900PA DIAL-UP WITH AUTOMATIC DISCONNECT MADE IN AUSTRALIA BY Est. 1968 TELEPHONE: (03) 9758 5933 FAX: (03) 9758 5560 E-MAIL: gen@design2000.com.au WEB SITE: www.design2000.com.au User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 9

MASTERCALL MD-4900 PA INTERFACE Packing List Quantity Item Use 1 Hide-away unit Electronics and connections 4 Rubber feet For base of hide-away unit 1 RJ12 to RJ12 telephone lead Connection to phone line 1 BL-4 screw terminal dc door strike 1 BL-3 screw terminal voltage-free (dry) relay contacts 1 Wall plug (drill size 3/16 (5 mm)) Masonry applications 1 6g x 25 mm cross-recess pan head screw Wall mount Hide-away unit option 1 This manual - Document G/01141B How to use this Interface Est. 1968 TELEPHONE: (03) 9758 5933 FACSIMILE: (03) 9758 5560 E-MAIL: gen@design2000.com.au WEB SITE: www.design2000.com.au User Guide for Mastercall Dial Up PA Interface MD-4900PA Document G/01141B Issue 5 Page 10