SECOND SUITE GENERAL DESIGN REQUIREMENTS

Similar documents
BUILDING PERMIT SPECIFICATIONS

Number of Sides Required to Have a Handrail

New Ontario Building Code Highlights

The replacement or modification of existing windows shall comply with the following requirements:

How To Build A Basement House

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Single Family Residential Basement Finish

City of Peterborough

Basement Development Construction requirements for the development of basements in residential dwellings.

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev


H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Building Code Clarifications - 7. Fire Resistance

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Property Maintenance Check List

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)

NRC Canadian Codes Centre. Codes Update. Nedjma Belrechid October 2012

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

New York City Department of Buildings

CITY OF TORONTO. BY-LAW No

FINISHED BASEMENT SUBMITTAL GUIDE

Smoke & Carbon Monoxide

Applications for building permits will not be reviewed until all of the required information has been submitted.

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Walking and Working Surface Checklist:

Building Control Guidance Note

Minimum Housing and Health Standards

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Excerpts from the Canadian National Building Code (NBC)

Guidance on loft conversions in two-storey houses

Smoke & Carbon Monoxide

COMMONLY USED RESIDENTIAL BUILDING CODES

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

- 5 - Table1. Maximum Compartment Volumes

Development Services City of Lawrence, KS

Typical Finished Basement Details

City of Elk River BASEMENT Office Use Only

City of St. Charles Basement Finish or Remodel

Name Of Occupancy Date. Yes No Describe

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

CERTIFICATE OF COMPLIANCE

St. John s University

Typical Finished Basement Details

How To Make A House Safe

HOUSING QUALITY STANDARDS (HQS)

2012 CODES SIGNIFICANT CHANGES 2012 IBC

RRIO Checklist. Use of checklist: Definitions: Limitations

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

EXISTING BUILDINGS AND STRUCTURES

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Arapahoe County Residential Water Heater Installation and Inspection Guide

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/20/2009)

FINISHED BASEMENT REQUIREMENT GUIDE

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

Overview of Hotel Fire Safety Requirements

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

Certification: Building Plans Examiner. Exam ID: B3

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

City of Riverside Building & Safety Division Phone: (951)

Guide to Massachusetts Smoke & Carbon Monoxide Requirements

*It is unlawful to occupy or use any project for which a permit was issued without first receiving final inspection approval from this department.

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

2010 FLORIDA BUILDNG CODE, FIRE AND LIFE SAFETY i

Current as of 11/10/08 1 of 1

Residential Code Requirements

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Rental Property Safety Inspection Checklist

17,280 square feet Overview:

New York City Department of Buildings

Rochdale Building Control Guide. Approved Document F Means of ventilation

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

NUNAVUT HOUSING CORPORATION. Home Repair Program (HRP)

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

Approved Document Q: Security

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

Transcription:

SECOND SUITE GENERAL DESIGN REQUIREMENTS OBC Part 9 HOUSES EXISTING LESS THAN FIVE YEARS (Part 9) OBC HOUSES EXISTING MORE THAN FIVE YEARS Part 11 (Part 11) 9.4 Floors not previously designed for use as a habitable space, or where it is proposed to be structurally altered, must be assessed by a Professional Engineer. 11.4.2. (Same as Part 9) 9.5.3.1. Living, Dining, Kitchen room heights shall not be less than 2300mm (7ft-7in) over 75% of the required floor area (required floor areas shall not include areas having a clear height of less than 1400mm (4ft-7in)) or 2100mm (6ft-11in) over all the required floor area. Bedroom heights shall not be less than 2300mm (7ft-7in) over 50% of the required floor area and 2100mm (6ft-11in) in the remaining required area. Bathroom and Laundry room heights shall not be less than 2100mm (6ft-11in) in any place where a person normally stands. C98 Any proposed room heights shall not be less than 1950mm (6ft-5in) over the required floor area and in any location that would normally be used as a means of egress, or, Any proposed room height shall not be less than 2030mm (6ft-8in) over at least 50% of the required floor area. (required floor areas shall not include areas having a clear height of less than 1400mm (4ft-7in)) Hallway room heights shall not be less than 2100mm (6ft-11in)

9.5.4. Living space serving two or more bedrooms shall have a minimum area of not less than 13.5m² (145ft²) and a Living space serving one bedroom shall have a minimum area of not less than 11m² (118ft²) Combined Dining space shall have a minimum area of not less than 3.25m² (35ft²) and a proposed separate Dining space shall have a minimum area of not less than 7m² (75ft²) Kitchen space serving two or more bedrooms shall have a minimum area of not less than 4.2m² (45ft²) and a Kitchen space serving one bedroom shall have a minimum area of not less than 3.7m² (40ft²) Master Bedroom space with built-in closets shall have a minimum area of not less than 6m² (65ft²) and a proposed Master Bedroom space without built-in closets shall have a minimum area of not less than 7m² (65ft²) Secondary Bedroom space with built-in closets shall have a minimum area of not less than 8.8 m² (95ft²) and a proposed Secondary Bedroom space without built-in closets shall have a minimum area of not less than 9.8m² (105ft²) Combined Bedroom space shall have a minimum area of not less than 4.2m² (45ft²) Proposed suite with all spaces combined with only one bedroom space shall have a minimum area of not less than 13.5m² (145ft²) NOTE: ZONING BYLAW REQUIRES MINIMUM 37m² (400ft²) PER SUITE

9.6.3.1. Doors shall be 1980mm (6ft-6in) in height. C99 Proposed doors may be reduced in height to suit ceiling heights. 9.6.6.2. & 9.6.6.3. Glass or mirrored entrance doors and sidelights that could be mistaken for clear passage shall be tempered or of safety type glass. C102 Existing glass or mirrored doors and sidelights that could be mistaken for clear passage need not be tempered or of safety type glass if the glass in doors or sidelights is made readily identifiable (by markings) or protected by a laminated film or other safety measure. 9.6.8.3. Deadbolt locks with a minimum 25mm (1in) throw must be provided on all swinging exterior doors that lead into the dwelling. 9.6.8.8. Main entry doors to each suite shall be provided with a door viewer, door window or sidelight. 9.7.1.2. Laundry, Washroom, Kitchen, Storage, Basement Recreation, rooms do not require windows. Living and Dining rooms require a minimum window glass area of 10% of the floor area served. Bedrooms and other normally occupied rooms require a minimum window glass area of 10% of the floor area served. C103 Proposed Living rooms, Dining rooms and Bedrooms may reduce the minimum window glassed area from 10% of the floor area served to 5%, where the windows are not needed as a means of egress (escape) and where they are not required for ventilation. 9.7.1.3. & 9.7.1.4. & 9.7.1.6. Proposed floor levels containing a bedroom need not have an openable window for escape, where there is direct access to the exterior from that floor level. C104 (Same as Part 9) Where there is no direct access to the exterior, one window on that floor must have a minimum unobstructed opening of 0.35m² (3.8ft²) with no

dimension less than 380mm (1ft-3in). Where a suite is located in the basement and requires a window that opens onto a window well for escape, the well must provide 550mm (1ft-10in) clearance when the window is fully open. Above ground windows with sills less than 480mm (1ft-7in) from the floor must be protected. 9.8.1. to 9.8.4. Stairs shall have a width of not less than 860mm (2ft-10in) and a width of not less than 900mm (2ft- 11in) for exit stairs. The minimum clear height over stair tread nosing or landing of 1950mm (6ft-5in). C107 Replacement or extension of an existing stair system shall be exempt from the standards, provided that they have a minimum width between wall faces of 700mm (2ft-4in), and a minimum clear height over tread nosing or landing of 1800mm (5ft- 11in). 9.8.4.4. Curved stairs shall have a minimum average run of 200mm (7.875in) and a minimum run of 150mm (5.875in). Spiral stairs are not permitted. C108 Existing curved or spiral stairs are acceptable. 9.8.4.5. Proposed extensions to a stair may contain multiple sets of winders provided that they are separated by at least 6 straight treads or a landing 1200mm (3ft-11in) in length, and complies with all other step dimension standards. C109 Proposed extensions to a stair may contain two sets of winders provided that they are separated by at least 3 straight treads or a landing 860mm (2ft-10) in length, and complies with all other step dimension standards. 9.8.5.1. Ramps shall have a minimum width of 860mm (2ft- 10in) and a maximum vertical slope of 1:10. The minimum headroom clearance shall be 1950mm (6ft-5in). C110 Existing ramps acceptable, where practical. 9.8.6. Landings shall be the same width of the stair, but not less than 900mm (2ft-11in) in width and not less than 860mm (2ft-10) in length.

9.8.7. Handrails shall be provided on interior stairs with more than two risers and on both sides of interior straight stair that are more than 1100mm (3ft-7) in length. The top of the handrail shall be located between 800mm (2ft-7in) and 965mm (3ft-2in) measured vertically from the stair nosing. 9.8.8. Guard-railings shall be a minimum of 900mm (2ft- 11in) in height for interior applications and a minimum of 1070mm (3ft-6in) in height for exterior applications where the floor level is greater than 1800mm (5ft-11in) above the adjacent ground. Guard-railings shall be non-climbable and have pickets spaced not more than 100mm (4in). 9.9.3.2. Proposed exit width shall be not less than 900mm (2ft-11in) 9.9.3.4. Proposed exit and access to exit shall have a clear height of not less than 2100mm (6ft-11in). C111 C112 C116 C118 Existing handrails acceptable, unless considered unsafe by the Chief Building Official. Existing guard-railings are acceptable, unless considered unsafe by the Chief Building Official. Existing exit width shall be not less than 800mm (2ft-7in). Existing exit and access to exit shall have a clear height of not less than 1950mm (6ft-5in). 9.9.4.2. Proposed exit must be fire separated from both suites by a minimum of 45 minute fire resistance rating. Suites that occupy more than two storeys C120 must have exits fire separated from both suites by a minimum of 1 hour resistance rating. Proposed fire resistance rating may be reduced to 30 minutes for the exit fire separation. 9.9.5.4. Proposed exit shall have no obstruction to the minimum required exit width. 9.9.5.9. Ancillary rooms (washroom, storage room, laundry room, furnace room) shall not open directly into an exit. C121 C123 Existing minor obstructions in an exit is permitted. Existing ancillary rooms (washroom, storage room, laundry room, furnace room) may open into an exit, provided that the enclosure has a 45 minute

fire-resistance rating. 9.9.6.7. Doors providing access [path] to exit [exterior] are not permitted to be keyed in the direction of exiting. 9.9.7.5. & 9.9.9. Proposed access [path] to exit from one suite C134 shall not be through another suite nor shall the path of travel from any suite be more than one storey to an outside exit door which is not more than 1500mm (4ft-11in) above adjacent ground level or to an enclosed exit stair. Proposed access (path) to exit is acceptable, if a door, including a sliding door, that opens directly to the exterior from a suite, serves only that dwelling suite and has reasonable access to ground level, and both suites are equipped with interconnected hardwired smoke alarms, or, Proposed access (path) to exit is acceptable, if an exit that is accessible to more than one suite and provides the only means of egress [path to outside] from each suite, provided that the means of egress [path to outside] is separated from the remainder of the house and common areas by a fire separation having a 30 minute fire-resistance rating and provided further that the required access [path] to exit from any suite cannot be through another suite, or service room and both suites and common areas are provided with interconnected hardwired smoke alarms, or, Proposed access (path) to exit is acceptable, if an access [path] to an exit from one suite which leads through another suite where an additional means of escape is provided through a window where the sill height is not more than 1000mm (3ft-3in) above or below adjacent ground level, can be opened from the inside without the use of tools, has an individual

9.9.11.3. Emergency lighting is required in a common exit. C137 (Same as Part 9) unobstructed open portion having a minimum area of 0.38 m² with no dimension less than 460mm (1ft- 6in), has a sill height not exceeding 900mm (2ft- 11in) above the floor or fixed steps, where the window opens into a window well, a clearance of not less than 1000mm (3ft-3in) shall be provided in front of the window, interconnected hardwired smoke alarms are installed in both suites and common areas, an additional means of escape is provided through a casement window not less than 1060mm (3ft-6in) high, 560mm (1ft-10in)wide, with a sill height not more than 900mm (2ft-11in)above the inside floor, where the sill height of the window is not more than 5m (16ft-5in) above adjacent ground level. 9.10.3.2. The maximum flame spread rating is 150 (FSR) for suite interior walls and ceilings. The maximum flame spread rating for exit walls and ceilings is 25 (FSR) of which 10% may be 150 (FSR). 9.10.9.7. Combustible piping is only permitted to pierce a fire separation with an approved firestop system. C145 Compliance alternative gives no relief for new fire separations. (Same as Part 9) 9.10.9.14. Proposed suites shall be separated from each other C149 by a fire separation with a minimum fire resistance rating of 45 minutes. If either suite occupies more than one storey the minimum fire resistance rating increases to 1 hour. All fire separations are permitted to be reduced to 30 minute fire resistance rating. Horizontal fire separations are permitted to be further reduced to 15 minute fire resistance rating, where interconnected hardwired smoke alarms are installed in every suite and in common area. Vertical fire separations are permitted to be

waived where interconnected hardwired smoke alarms are installed in every suite and in common area. Vertical fire separations are permitted to be waived, where the service room is sprinklered. 9.10.9.19. Central vacuum system shall not serve more than one suite. 9.10.10.3. Furnace rooms serving more than one suite shall be fire separated from the suites with a fire resistance rating of at least 1 hour. The fire-resistance rating of the vertical fire separation is waived where the furnace room is sprinklered. 9.10.13.2. Solid core wood doors, 45 mm thickness, are permitted to be used to achieve a 20 minute fire protection rating provided it is labeled as conforming. C150 C153 The fire separation of the furnace room is permitted to be reduced to a 30 minute fire resistance rating. The fire-resistance rating of the furnace room s vertical fire separation is waived where interconnected hardwired smoke alarms are installed in every suite and in all common areas. Existing unlabelled Solid core wood or metal clad doors, 45 mm thickness, are acceptable. 9.10.13.3. Unrated wood door frame is acceptable where it is used to achieve a 20 minute fire protection rating and is a minimum 38mm (1.5in) thick. C155 Existing unrated wood door frame of less than 38mm (1.5in) thick is acceptable provided that it is secured with hinge screws going through frame into the stud. 9.10.13.10. All doors in fire separation shall have a functionally operable self-closing device. C161 (Same as Part 9) 9.10.13.12. Furnace room doors shall swing outward. C163 Existing door swing to a furnace room is acceptable. 9.10.13.13. Ducts and openings in fire separations must be C165 Existing duct penetrations in fire separations

equipped with approved fire dampers. 9.10.13.14. Ceiling openings in fire separations must be equipped with approved fire stop flaps. 9.10.5.1. Proposed fire rated wall and ceiling assemblies pierced by outlet type boxes must be tested and approved for their installation. 9.10.16.2. Fire stops shall be provided between every interconnected concealed vertical and horizontal space, between every interconnected concealed interior and exterior space. 9.10.19. Smoke alarms must be hardwired to the electrical panel but may have battery backup in case of power failure. Smoke alarms must be interconnected and installed on the ceiling within 5m (16ft-5in) of any bedroom and within 15m (49ft-3in) of any point of every storey. 9.10.20. Access for firefighting shall be provided to every second or third storey, facing a street, by a window or door. Access for firefighting shall be provided to every building by an acceptable driveway. C166 C167 C170 C172 C173 acceptable without fire dampers. Existing fire separations acceptable without fire stop flaps provided smoke alarms are installed in each suite and provided a smoke detector is installed in the supply or return air duct system serving the entire building which would turn off the fuel supply and electrical power to the heating system upon activation of such detectors. Existing fire rated wall and ceiling assemblies pierced by outlet type boxes are acceptable. Existing fire stopping acceptable except where balloon framing is exposed during renovation. Smoke alarms may be battery operated if electrical AC power was not required by another compliance alternative. Regardless of the power source the smoke alarms must be interconnected with each other. Existing access for firefighting acceptable. 9.11. Each suite shall be separated from each other

including common areas by a minimum sound transmission class rating of 50 (STC). 9.31.4 Each suite shall be equipped with a kitchen sink, a wash basin, a bathtub or a shower and a toilet. Each suite shall be equipped with laundry facilities, or have ready access to a common space for laundry facilities. 9.32. Kitchens and washrooms must have mechanical exhaust ventilation systems. 9.33. Heating or air-conditioning system may not serve more than one suite. Hardwired interconnected carbon monoxide detectors shall be installed in all suites where the house includes any fuel-burning appliance or includes an attached garage. C191 C192 Proposed rooms or spaces in suites may be ventilated by natural means or by adequate mechanical ventilation. Existing heating or air-conditioning system may be altered to serve more than one suite provided smoke alarms are installed in each suite and provided a smoke detector is installed in the supply or return air duct system serving the entire building which would turn off the fuel supply and electrical power to the heating system upon activation of such detectors. Hardwired interconnected carbon monoxide detectors shall be installed in all suites where the house includes any fuel-burning appliance or includes an attached garage. 9.34.2 Electric lighting is required in most areas including at exterior entrances.