Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages



Similar documents
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relay CM-PFE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Analog signal converters CC-E I/I Current / current isolators

Thermistor motor protection

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Three-phase monitoring relays Product group picture

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

38 Series - Relay interface modules A

Manual motor starter MS116

38 Series - Relay interface modules A

Type: DILM32 10(24V50HZ) Article No.:

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

EMR measuring and monitoring relays

Pluggable interface relays CR-P Pcb relays

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM50(230V50HZ,240V60HZ) Article No.:

RM4TG20 three-phase network control relay RM4-T - range V

Relés e Contatores de Estado Sólido SIRIUS

MasterINTERFACE 39 Series - Relay interface modules

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

48 SERIES Relay interface modules 10 A

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Type: DILM9 10(24VDC) Article No.:

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MasterINTERFACE 39 Series - Relay interface modules

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Signal converters Index

Catalog. Modular DIN rail components Installation contactors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

49 Series - Relay interface modules A. Features

Signal converters Index

R.C.C.B. s two-pole LEXIC

80 Series - Modular timers 16 A. Features

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

15 Series - Electronic step relay and dimmer. Features SERIE

ZS25 Screw Clamp Terminal Blocks Feed-through

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Technical catalogue. Modular DIN rail components Installation contactors

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Safety technique. Emergency stop module BO 5988 safemaster

Bimetallic Overload Relay Specifications

Control Devices Catalogue. Control Devices. Preferred and Standard Products

E-STOP relays, safety gate monitors

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Digital input modules

Power Supplies 3. SDN-P DIN Rail Series

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Technicaldata General

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

80 Series - Modular timers 16 A. Features

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Trip circuit supervision relay. Type RXTCS

ZS10 Screw Clamp Terminal Block

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

mecotron Safety relay ESTOP-2 For emergency stop monitoring

PHOENIX CONTACT Features

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

7 - Phaseo power supplies and transformers

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

RY2 miniature industrial relays

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Panel Meters and Controllers Modular Panel Meter Type EDM 35

5SV Residual Current Protective Devices

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Safety automation solutions

Thermal-Magnetic Circuit Breaker M1-..

Quick Connect. quick - simple - efficient.

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Transcription:

Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of phase loss. All devices are available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connecting terminals) and the completely tool-free Easy Connect Technology (push-in terminals). 2CDC 251 060 V0011 Characteristics Monitoring of DC and AC voltages (3-600 V) TRMS measuring principle One device includes 4 measuring ranges Over- or undervoltage monitoring configurable Open- or closed-circuit principle configurable Latching function configurable Hysteresis adjustable (3-30 %) Tripping delay T V adjustable (0 s; 0.1-30 s) Precise adjustment by front-face operating controls Screw connection technology or Easy Connect Technology available Housing material for highest fire protection classification UL 94 V-0 Tool-free mounting on DIN rail as well as demounting 2 c/o (SPDT) contacts 22.5 mm (0.89 in) width 3 LEDs for status indication Approvals A UL 508, CAN/CSA C22.2 No.14 C GL R EAC K CB Scheme E CCC L RMRS Marks a CE b C-Tick Order data Voltage monitoring relays Type Rated control supply voltage Connection technology Measuring ranges Order code CM-ESS.MP 24-240 V AC/DC Push-in terminals 3-30 V, 6-60 V, 30-300 V, 60-600 V 1SVR740830R0500 CM-ESS.MS Screw type terminals 1SVR730830R0500 Accessories Type Description Order code ADP.01 Adapter for screw mounting 1SVR430029R0100 MAR.12 Marker label for devices with DIP switches 1SVR730006R0000 COV.11 Sealable transparent cover 1SVR730005R0100

Connection technology Maintenance free Easy Connect Technology with push-in terminals Type designation CM-xxS.yyP Approved screw connection technology with double-chamber cage connecting terminals Type designation CM-xxS.yyS 2CDC 253 026 F0011 2CDC 253 025 F0011 Push-in terminals Tool-free connection of rigid and flexible wires with wire end ferrule according to DIN 46228-1-A, DIN 46228-4-E Wire size: 2 x 0.5-1.5 mm², (2 x 20-16 AWG) Easy connection of flexible wires without wire end ferrule by opening the terminals No retightening necessary One operation lever for opening both connecting terminals For triggering the lever and disconnecting of wires you can use the same tool (Screwdriver according to DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 ø 4.5 mm (0.177 in)) Constant spring force on terminal point independent of the applied wire type, wire size or ambient conditions (e. g. vibrations or temperature changes) Opening for testing the electrical contacting Gas-tight Double-chamber cage connecting terminals Terminal spaces for different wire sizes: fine strand with/without wire end ferrule: 1 x 0.5-2.5 mm² (2 x 20-14 AWG), 2 x 0.5-1.5 mm² (2 x 20-16 AWG) rigid: 1 x 0.5-4 mm² (1 x 20-12 AWG), 2 x 0.5-2.5 mm² (2 x 20-14 AWG) One screw for opening and closing of both cages Pozidrive screws for pan- or crosshead screwdrivers according to DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 ø 4.5 mm (0.177 in) Both the Easy Connect Technology with push-in terminals and screw connection technology with double-chamber cage connecting terminals have the same connection geometry as well as terminal position. 2 - Voltage monitoring relays CM-ESS.M Data sheet

Functions Operating controls 1 Adjustment of the hysteresis 2 Adjustment of the threshold value 3 Indication of operational states U/T: LED green control supply voltage 1 2 R: LED yellow relay status U: LED red over- / undervoltage 4 Adjustment of the measuring range 2CDC 251 052 V0011 3 4 5 6 5 Adjustment of the tripping delay T V 6 DIP switches (see DIP switch functions)! When compared with our previous version, the position of the adjustment potentiometers 4 and 5 have changed places. Application The multifunctional voltage monitoring relays CM-ESS.M are designed for use in single-phase AC and/or DC systems for over- or undervoltage monitoring as well as detection of phase loss. The devices operate over an universal range of supply voltages, provide an adjustable tripping delay and work according to the open- or closed-circuit principle. Operating mode The CM-ESS.2 have 2 c/o (SPDT) contacts and include 4 measuring ranges: 3-30 V, 6-60 V, 30-300 V and 60-600 V. The units are adjusted with front-face operating controls. The selection of over- b or undercurrent monitoring a, openh or closed-circuit principle g and latching function ON f or OFF e is made with DIP switches. Potentiometers, with direct reading scale, allow the adjustment of the threshold value U, the hysteresis % and the tripping delay T V. The hysteresis % is adjustable within a range of 3 to 30 % of the threshold value and the tripping delay T V over a range of instantaneous to a 30 s delay. Timing is displayed by a flashing labelled U/T. Data sheet Voltage monitoring relays CM-ESS.M - 3

Function diagrams Overvoltage monitoring d without latching e Open-circuit principle h The voltage to be monitored (measured value) is applied to terminals B-C. The control supply voltage applied to terminals A1-A2 is displayed by the glowing. If the measured value exceeds the adjusted threshold value, the tripping delay T V starts and the (overvoltage) glows. Timing of T V is displayed by the flashing W. When T V is complete and the measured value still exceeds the threshold value minus the adjusted hysteresis, the output relays energize and the (relay energized) glows. If the measured value drops below the threshold value minus the adjusted hysteresis, the output relays de-energize and the red and s turn off. If control supply voltage is interrupted, the turns off. Closed-circuit principle g The voltage to be monitored (measured value) is applied to terminals B-C. When control supply voltage is applied to terminals A1-A2, the output relays energize and the green and (relays energized) glow. If the measured value exceeds the adjusted threshold value, the tripping delay T V starts and the glows (overvoltage). Timing of T V is displayed by the flashing W. When T V is complete and the measured value still exceeds the threshold value minus the adjusted hysteresis, the output relays de-energize and the turns off. If the measured value decreases below the threshold value minus the hysteresis, the output relays re-energize, the yellow LEDs glows and the turns off. If control supply voltage is interrupted, the output relays de-energize and the green and s turn off. A1-A2 Threshold Hysteresis Measured value Open-circuit principle open T V Closed-circuit principle closed 2CDC 252 228 F0205 4 - Voltage monitoring relays CM-ESS.M Data sheet

Undervoltage monitoring c without latching e Open-circuit principle h The voltage to be monitored (measured value) is applied to terminals B-C. The control supply voltage applied to terminals A1-A2 is displayed by the glowing. If the measured value decreases below the adjusted threshold value, the tripping delay T V starts and the (undervoltage) flashes W. Timing of T V is displayed by the flashing W. When T V is complete and the measured value is still below the threshold value plus the adjusted hysteresis, the output relays energize and the (relay energized) glows. If the measured value exceeds the threshold value plus the adjusted hysteresis, the output relays de-energize and the red and s turn off. If control supply voltage is interrupted, the turns off. Closed-circuit principle g The voltage to be monitored (measured value) is applied to terminals B-C. When control supply voltage is applied to terminals A1-A2, the output relays energize and the green and (relays energized) glow. If the measured value decreases below the adjusted threshold value, the tripping delay T V starts and the flashes W (undervoltage). Timing of T V is displayed by the flashing W. When T V is complete and the measured value is still below the threshold value plus the adjusted hysteresis, the output relays de-energize and the yellow LED turns off. If the measured value exceeds the threshold value plus the hysteresis, the output relays re-energize, the glows and the turns off. If control supply voltage is interrupted, the output relays de-energize and the green and yellow LEDs turn off. A1-A2 Measured value Hysteresis Threshold Open-circuit principle open T V Closed-circuit principle closed 2CDC 252 229 F0205 Data sheet Voltage monitoring relays CM-ESS.M - 5

Overvoltage monitoring d with latching f Open-circuit principle h The voltage to be monitored (measured value) is applied to terminals B-C. The control supply voltage applied to terminals A1-A2 is displayed by the glowing. If the measured value exceeds the adjusted threshold value, the tripping delay T V starts and the glows (overvoltage). Timing of T V is displayed by the flashing W. When T V is complete and the measured value still exceeds the threshold value minus the adjusted hysteresis, the output relays energize and the (relay energized) flashes Z. If the measured value decreases below the threshold value minus the hysteresis, the turns off. The output relays remain energized (latching function). If control supply voltage is interrupted (reset), the output relays de-energize and the green and s turn off. Closed-circuit principle g The voltage to be monitored (measured value) is applied to terminals B-C. When control supply voltage is applied to terminals A1-A2, the output relays energize and the green and (relays energized) glow. If the measured value exceeds the adjusted threshold value, the tripping delay T V starts and the glows (overvoltage). Timing of T V is displayed by the flashing W. When T V is complete and the measured value still exceeds the threshold value minus the adjusted hysteresis, the output relays de-energize and the flashes Y. If the measured value decreases below the threshold value minus the hysteresis, the turns off. The output relays remain de-energized (latching function). If control supply voltage is interrupted (reset), the green and s turn off. The output relays energize again when control supply voltage is re-applied. A1-A2 Threshold Hysteresis Measured value Reset Open-circuit principle open T V Closed-circuit principle closed 2CDC 252 230 F0205 6 - Voltage monitoring relays CM-ESS.M Data sheet

Undervoltage monitoring c with latching f Open-circuit principle h The voltage to be monitored (measured value) is applied to terminals B-C. The control supply voltage applied to terminals A1-A2 is displayed by the glowing. If the measured value decreases below the adjusted threshold value, the tripping delay T V starts and the flashes W (undervoltage). Timing of T V is displayed by the flashing W. When T V is complete and the measured value is still below the threshold value plus the adjusted hysteresis, the output relays energize and the (relays energized) flashes Z. If the measured value exceeds the threshold value plus the hysteresis, the turns off. The output relays remain energized (latching function). If control supply voltage is interrupted (reset), the output relays de-energize and the green and s turn off. Closed-circuit principle g The voltage to be monitored (measured value) is applied to terminals B-C. When control supply voltage is applied to terminals A1-A2, the output relays energize and the green and (relays energized) glow. If the measured value decreases below the adjusted threshold value, the tripping delay T V starts and the flashes W (undervoltage). Timing of T V is displayed by the flashing W. When T V is complete and the measured value is still below the threshold value plus the adjusted hysteresis, the output relays de-energize and the yellow LED flashes Y. If the measured value exceeds the threshold value plus the hysteresis, the turns off. The output relays remain deenergized (latching function). If control supply voltage is interrupted (reset), the green and s turn off. The output relays energize again when control supply voltage is re-applied. A1-A2 Measured value Hysteresis Threshold Reset Open-circuit principle open T V Closed-circuit principle closed 2CDC 252 231 F0205 Data sheet Voltage monitoring relays CM-ESS.M - 7

Electrical connection A1 11 15 21 25 B B 11 15 21 25 A1-A2 Rated control supply voltage B-C Measuring ranges: 3-30 V, 6-60 V, 30-300 V, 60-600 V 11 15-12 16 /14 18 Output contacts - open- or closed-circuit principle 21 25-22 26 /24 28 C A1 A2 12 16 14 18 22 26 24 28 14 18 12 16 C 24 28 22 26 A2 2CDC 252 207 F0005 Connection diagram DIP switches Position 4 3 2 1 ON OFF closed open V V 2CDC 252 276 F0005 1 ON Undervoltage monitoring OFF Overvoltage monitoring 2 ON Closed-circuit principle OFF Open-circuit principle 3 ON Latching function activated OFF Latching function not activated OFF = Default 8 - Voltage monitoring relays CM-ESS.M Data sheet

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Supply circuit A1-A2 Rated control supply voltage U s 24-240 V AC/DC Rated control supply voltage U s tolerance -15...+10 % Rated frequency 50/60 Hz Typical current / power consumption 24 V DC 30 ma / 0.75 W 115 V AC 17 ma / 1.9 VA 230 V AC 11 ma / 2.6 VA Power failure buffering time 20 ms Transient overvoltage protection varistors Measuring circuit B-C Monitoring function over- or undervoltage monitoring configurable Measuring method TRMS measuring principle Measuring inputs terminal connection B-C measuring range 3-30 V, 6-60 V, 30-300 V, 60-600 V input resistance 600 kω pulse overload capacity t < 1 s 800 V continuous capacity 660 V Threshold value adjustable within the indicated measuring range Tolerance of the adjusted threshold value 10 % of the range end value Hysteresis related to the threshold value 3-30 % adjustable Measuring signal frequency range DC / 15 Hz - 2 khz Rated measuring signal frequency range DC / 50-60 Hz Maximum response time AC 80 ms DC 120 ms Accuracy within the rated control supply voltage tolerance ΔU 0.5 % Accuracy within the temperature range ΔU 0.06 % / C Transient overvoltage protection varistors Timing circuit Time delay T V 0 s or 0.1-30 s adjustable Repeat accuracy (constant parameters) ±0.07 % of full scale Tolerance of the adjusted time delay - Accuracy within the rated control supply voltage tolerance Δt 0.5 % Accuracy within the temperature range Δt 0.06 % / C User interface Indication of operational states Control supply voltage U/T: V: control supply voltage applied W: tripping delay T V active Measured value U: V: overvoltage W: undervoltage Relay status R: V: output relay energized, no latching function Z: relay energized, active latching function Y: relay de-energized, active latching function Data sheet Voltage monitoring relays CM-ESS.M - 9

Output circuits Kind of output 11-12/14 relay, 1st c/o (SPDT) contact 21-22/24 relay, 2nd c/o (SPDT) contact Operating principle open- or closed-circuit principle configurable (opencircuit principle: output relays energize if the measured value exceeds d / falls below c the adjusted threshold value, closed-circuit principle: output relays de-energize if measured value exeeds d / falls below c the adjusted threshold value) Contact material AgNi Rated operational voltage U e (VDE 0110, IEC/EN 60947-1) 250 V Minimum switching voltage / Minimum switching current 24 V / 10 ma Maximum switching voltage / Maximum switching current 250 V AC / 4 A AC Rated operational current I e AC12 (resistive) at 230 V 4 A (IEC/EN 60947-5-1) AC15 (inductive) at 230 V 3 A DC12 (resistive) at 24 V 4 A DC13 (inductive) at 24 V 2 A AC rating (UL 508) utilization category (Control Circuit Rating Code) B 300 max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking 3600/360 VA apparent power at B 300 Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime AC12, 230 V, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve n/c contact 10 A fast-acting short-circuit protection n/o contact 10 A fast-acting General data MTBF on request Duty time 100 % Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in) packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) Weight Screw connection technology Easy Connect Technology (Push-in) Net weightv 0.154 kg (0.340 lb) 0.143 kg (0.315 lb) Gross weight 0.176 kg (0.388 lb) 0.165 kg (0.364 lb) Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Material of housing UL 94 V-0 Degree of protection housing IP50 terminals IP20 10 - Voltage monitoring relays CM-ESS.M Data sheet

Electrical connection Screw connection technology Easy Connect Technology (Push-in) Wire size fine strand with(out) 1 x 0.5-2.5 mm² 2 x 0.5-1.5 mm² wire end ferrule (1 x 20-14 AWG) (2 x 20-16 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) rigid 1 x 0.5-4 mm² 2 x 0.5-1.5 mm² (1 x 20-12 AWG) (2 x 20-16 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm - (5.31-7.08 lb.in) Environmental data Ambient temperature ranges operation -20...+60 C storage -40...+85 C Damp heat, cyclic (IEC/EN 60068-2-30) 55 C, 6 cycle Vibration, sinusoidal (IEC/EN 60255-21-1) Class 2 Shock (IEC/EN 60255-21-2) Class 2 Isolation data Rated insulation voltage U i supply / measuring circuit / output 600 V (IEC/EN 60947-1, IEC/EN 60255-5) supply / output 1 / output 2 250 V Rated impulse withstand voltage U imp supply / measuring circuit / output 6 kv 1.2/50 μs (IEC/EN 60947-1, IEC/EN 60255-5) supply / output 1 / output 2 4 kv 1.2/50 μs Test voltage between all isolated circuits rated insulation voltage 250 V 2.0 kv, 50 Hz (routine test) rated insulation voltage 600 V 2.5 kv, 50 Hz Pollution degree (IEC/EN 60664, IEC/EN 60255-5) 3 Overvoltage category (IEC/EN 60664, IEC/EN 60255-5) III Standards Product standard IEC/EN 60255-1, IEC/EN 60255-27, EN 50178 Low Voltage Directive EMC Directive RoHS Directive 2006/95/EC 2004/108/EC 2002/95/EC Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 electrical fast transient / burst IEC/EN 61000-4-4 Level 3 surge IEC/EN 61000-4-5 Level 3 conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 radio-frequency fields Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B Data sheet Voltage monitoring relays CM-ESS.M - 11

Technical diagrams Load limit curves V V 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 194 F0205 V V 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 193 F0205 AC load (resistive) DC load (resistive) F 1.0 0.9 0.8 0.7 0.6 Switching cycles 250 V resistive load 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Derating factor F for inductive AC load 2CDC 252 192 F0205 Switching current [A] 2CDC 252 148 F0206 Contact lifetime 12 - Voltage monitoring relays CM-ESS.M Data sheet

Dimensions in mm and inches 113.4 4.47 105.9 4.17 22.5 0.89 85.6 3.37 103.7 4.08 2CDC 252 009 F0011 Accessories in mm and inches 22.5 0.89 8 0.32 4.8 0.19 6.5 0.256 62.5 2.461 60 2.362 70 2.756 10 11.5 0.394 0.453 20 0.787 2CDC 252 008 F0010 22.2 0.874 4T22 19.9 0.783 7.85 0.309 2CDC 252 020 F0011 68 2.68 front to back 110.5 4.31 2CDC 252 010 F0011 ADP.01 Adapter for screw mounting MAR.12 Marker label for devices with DIP switches COV.11 Sealable transparent cover Further documentation Document title Document type Document number Electronic products and relays Technical catalogue 2CDC 110 004 C02xx CM-ESS.M Instruction manual 1SVC 730 600 M0000 You can find the documentation on the internet at www.abb.com/lowvoltage -> Control Products -> Electronic Relays and Controls -> Single Phase Monitors CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/portal/portal/abb-control-products -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls -> Single Phase Monitors -> CM-ESx - Single Phase Monitors. Data sheet Voltage monitoring relays CM-ESS.M - 13

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 112 173 D0201 Rev C (10/2014) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2014 ABB All rights reserved