HCR3.2/.. Chipcard reader HOTEL SOLUTION



Similar documents
Digital input modules

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TX OPEN RS232/485 module

Waveguide Access Point WGA631. Product Guide

PCS0100en Persy Control Services B.V. Netherlands

OZS Web server. For LPB/BSB plants

RRV934. Multi-controller. Synco living

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Product and functional description

Inwall 4 Input / 4 Output Module

Air damper actuators

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Cross-beam scanning system to detect slim objects. 100 mm in

Product and Application Description

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

is then retained absolutely without interruption.

OZW30. Central Unit SYNERGYR

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Voltage Regulator SPAU 341 C. Product Guide

Power Meter Series 700

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

HERZ-Thermal Actuators

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

ACS-30-EU-EMDR-10-MOD

Flush-mount room temperature sensor AQR2531ANW.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Accessories SUNNY REMOTE CONTROL

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Hotel room management software

AXIS 291 1U Video Server Rack Installation Guide

WIRELESS MAGNETIC CONTACT

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

7 Lighting Technology

13 SERIES. Electronic step relays A

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

AXIS T81B22 DC 30W Midspan

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

SYSTEM DESCRIPTION Termination Boards

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

RM4TG20 three-phase network control relay RM4-T - range V

KNX Panasonic Air Conditioners

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

M1000 Process Alarm Monitor

Flush-mounted room thermostats

Digital Keypad Use s Manual

Quick Connect. quick - simple - efficient.

Danfoss Link Mobile Phone Butler

OZW V2.0. Web server. Synco TM, Synco TM living

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

PROXIMITY CARD READERS C-10, C-20, C60, C70

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

TrueAlarm Fire Alarm Systems

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

How To Use A Power Supply On A Powerline 2.2 (Ai)

IntesisBox Modbus Server SAMSUNG Air Conditioners

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ACR120 Technical Specifications version 2.9 November 2005

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

HMI display Installation Guide

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

MagIC Installation Manual. Point of Sales Terminals TD06014B

Wind Sensor W-RS485 with RS485 Interface

Automation stations modular model

Combi switchbox with integrated 3/2 way pilot valve

Shunt lock function 3066

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation

Duct Humidity Transmitter

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

VAV compact controller KNX / PL-Link

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Drayton Digistat +2RF/+3RF

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

GV- RK1352 Card Reader

Transcription:

s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages from hotel room Messages indicated by LEDs above imprinted symbols Membrane switch for doorbell feature Illuminated card slot Application The HCR3.2 chipcard reader is used in conjunction with the HRC3.1 and HRC3.2 room controllers. Guest and hotel-staff access codes are read by the HCR3.2 chipcard reader and transmitted to the HRC3.1/HRC3.2 room controller for access control. CM2N6332en Building Technologies

Function The HCR3.2 chipcard reader communicates with the HRC3.1/HRC3.2 room controller via a serial port, performing the following functions: Reads the access code on a chipcard After reading it, transfers the access code to the HRC3.1/HRC3.2 room controller Activates the functions programmed in the HRC3.1/HRC3.2 room controller based on the access code concerned (guest code, hotel staff code, invalid code). Transfers the membrane switch signal for the optional doorbell feature Displays signals from the HRC3.1/HRC3.2 room controller with illuminated LEDs above imprinted symbols Control of the illumination of the slot via the HRC3.1/HRC3.2 room controller Types HCR3.2/BB HCR3.2/BW HCR3.2/VB HCR3.2/VW Chipcard reader for Bticino Living cover-plate range Chipcard reader for Bticino Light cover-plate range Chipcard reader for Vimar Idea cover-plate range Chipcard reader for Vimar Plana or Ikon cover-plate range Ordering Example When ordering, please specify the quantity, product name and type code: 30 Chipcard readers HCR3.2/BB The following items depend on the desired overall program and installation type and must be ordered separately from the corresponding frame supplier: Flush-mounted or cavity wall box for integration. Cover frame of the corresponding supplier with desired surface. Compatibility Device Type Data sheet Room controller HRC3.1 N6313 Room controller HRC3.2 N6314 Chipcard reader on same room bus HCR3.2/.. N6332 Chipcard holder on same room bus HCH3.2/.. N6333 Chipcard encoder HCW3.2 N6340 Room operating unit on same room bus HTC3.2/.. N6320 2/8

Mechanical design Construction The chipcard reader consists of: Component assembly (carrier, printed circuit board, four LEDs, membrane switch, chipcard reader-unit, terminal block and DIP switch) Base frame: Bticino Living/Type L4703 for HCR3.2/BB Bticino Light/Type N4703 for HCR3.2/BW Vimar Idea/Type 16713 for HCR3.2/VB Vimar Plana or Ikon/Type 20613 for HCR3.2/VW The component assembly is permanently glued into the base frame and cannot, therefore, be replaced. Display Depending on the standard application configured in the HRC3.1/HRC3.2 room controller, the following room states can be displayed: Do not disturb "Make up room" or "Room service" call SOS call for assistance "Guest present" indicator (for hotel staff only) Door open Door closed Access denied Operator controls, connections and display elements Front view V1 V2 V3 V4 T1 6332Z01de 1 2 Key 1 Base frame with fixing screws Bticino Living/Type L4703 for HCR3.2/BB Bticino Light/Type N4703 for HCR3.2/BW Vimar Idea/Type 16713 for HCR3.2/VB Vimar Plana or Ikon/Type 16713 for HCR3.2/VW 2 Card slot backlit with 3 green LEDs V1 Red LED Door closed V2 Green LED Door open V3 Yellow LED Room service call V4 Yellow LED Do not disturb T1 Membrane switch Doorbell function 3/8

Rear view RS485+ RS485- DC 12 V DC 0 V ON ADR0 ADR1 PROT TERM 6332Z02de 4 3 Key STOP Important note 3 DIP switches Bus address setting (ADR0, ADR1) Protocol setting PROT = 0, for HRC3.1/HRC3.2 room controller PROT = 1, for HRC3.8 room controller Control of RS485 bus termination resistance TERM = 0, bus termination resistance disabled TERM = 1, bus termination resistance enabled 4 Terminal block Connection to room controller The bus termination resistance must be enabled on the last bus device only. Engineering notes Base frame The room unit is designed for flush wall mounting in conjunction with base frames and cover plates from various manufacturers: Bticino Living for HCR3.2/BB Bticino Light for HCR3.2/BW Vimar Idea for HCR3.2/VB Vimar Plana or Ikon for HCR3.2/VW Up to four chipcard readers may be connected to the same room bus. The address is set with DIP switches on the back of the unit (see below). STOP Important note The maximum permitted current associated with the supply voltage from the HRC3.1/HRC3.2 room controller must not be exceeded. (For further information, see data sheets CM2N6313 and CM2N6314.) 4/8

Mounting instructions The HCR3.2 chipcard reader must be mounted outside the hotel room at the same height as the light switch. Ensure that there is enough spare cable in the mounting box to allow operation of the address switches on the PCB. The device is intended for fixed installation in a dry, enclosed space. For installation in a 3-module mounting box, depth 50 mm. Must be mounted horizontally with the front plate vertical. Do not install AC 230 V devices in the same mounting box. Commissioning must be carried out by trained personnel only. Local safety and installation regulations must be observed. Commissioning To operate several devices connected to the same room controller, an address must be set for each one. Only one device will operate with the factory-set default. The addresses of the room operator units are set by DIP switch on the back of these units. Bus address ADR0 ADR1 0x38 OFF OFF 0x39 ON OFF 0x3A OFF ON 0x3B ON ON Note In the standard application with only one reader, Address 0x38 is intended for the HCR3.2 chipcard reader. This address is the factory-set default (both ADR switches to OFF). Operating notes Alarm messages Pattern All symbols OFF All symbols flashing (2 Hz) Description No supply voltage to the HCR3.2 Possible causes: Room controller off or faulty Bus cable not correctly connected, or connection broken Faulty HCR3.2 No communication with the room controller Possible causes: Wrong bus address set on HCR3.2 Wrong bus address set in room controller Bus cable not correctly connected, or connection broken Room controller in "Stop" mode Faulty RS485 interface 5/8

Technical data Power supply (from HRC3..) Operating voltage (SELV, PELV) DC 9..0.15 V Current Max. 50 ma Chipcards Type Siemens SLE5542, SLE4442 Format 86 mm x 54 mm x 0.76 mm Membrane switch ServiceService life 100,000 switching operations Bus interface Type RS485 Transmission speed 4800 baud Bus voltage SELV DC 12 V Display Luminous intensity of LEDs: 1.8 mcd Ambient conditions Normal operation To IEC 721-3-3: Class 3K5 Temperature 0...+50 C Humidity < 85 % rh Air pressure Min. 700 hpa, equivalent to max. 3,000 m above sea level Transport To IEC 721-3-2: Class 2K3 Temperature -25...+65 C Humidity < 95 % rh Air pressure Min. 260 hpa, equivalent to max. 10,000 m above sea level Industry standards Product safety Electromagnetic compatibility Automatic electrical controls for household EN 60 730 and similar use Emitted interference in accordance with EN 61000-6-3 Interference immunity in accordance with EN 61000-6-2 Housing To EN 60 529 IP20 protection standard Protection class To EN 60 730 III conformity Meets the requirements of: EMC Directive 89/336/EEC Low-voltage directive 73/23/EEC Environmental compatibility Environmental product declaration CM2E6332en provides data on environmentally compatible product design and assessment (material composition, packaging, disposal) ISO 14001 (environment) ISO 9001 (quality) UL/CUL approval UL/CUL 916 Installation Suitable for flush mounting in rectangular flush-mounting box or rounded hollow wall box HCR3.2/BB and HCR3.2/BW HCR3.2/VB and HCR3.2/VW 3 modules Bticino 503E (angular),ps563n (round) Vimar V71613 (round), V71304 (angular) Color Front-plate label RAL 9005 deep black Dimensions Weight 6/8 HCR3.2/BB Bticino frame L4703 HCR3.2/BW Bticino frame N4703 HCR3.2/VB Vimar frame 16713 HCR3.2/VW Vimar frame 20613 (without cover; & see dimension diagrams) Excluding packaging With packaging 115 mm x 72 mm x 47 mm 115 mm x 72 mm x 47 mm 118 mm x 75 mm x 48 mm 118 mm x 75 mm x 48 mm 0.069 kg 0.087 kg

Connection diagrams Connection terminals (DC 12 V) (GND) 6332G01 1 Serial port, RS485 + 2 Serial port, RS-485 3 DC 12 V operating voltage 4 DC 0 V operating voltage HCR3.2 connection diagram S2 S2 N1 HCR3.2 chipcard reader HRC3.1 room controller 6332A01 X12 N1 HCR3.2 connection diagram S2 S2 N1 HCR3.2 chipcard reader HRC3.2 room controller 6332A02 X3 N1 7/8

Dimensions HCR3.2/BB Dimensions in mm Diagram and dimensions of Bticino frame L4703. 115 47 6332M01 72 HCR3.2/VB Diagram and dimensions of Vimar frame 16713. Dimensions in mm 118 111,8 48 0,9 67 75 90,6 4 9 6332M02 Note See the frame supplier documentation for dimensions of other frames and hole spacing (Bticino, Vimar). 8/8 2006-2008 Siemens Switzerland Ltd Subject to change