Oil Burner Controls type BHO 64 and LOA 44

Similar documents
Assisted lift operated 2/2-way solenoid valves Type EV250B

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

HERZ-Thermal Actuators

Installation Guide. DEVIreg 530. Electronic Thermostat.

Cable Plug acc. to DIN EN , Form A

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

OPERATING AND MAINTENANCE INSTRUCTIONS LIGHT OIL BURNERS

DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

DEVIreg 330 (+5 to +45 C)

Joystick PVRES and PVREL. Technical Information

DKG 972 Gas Burner Safety Control

Triac Printed Circuit Board Replacement

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

RY2 miniature industrial relays

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

R.C.C.B. s two-pole LEXIC

3/2-way Solenoid Valve, direct-acting, NC or NO

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Combi B Alarm box. Mounting instructions

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Installation & User Instructions

Line-Mounted Valves L Series

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Plug and Socket Devices SolConeX 16 A Series 8570

User's Instructions. Alpha HE CB25/33 and HE SY25

System 8. ü ( System 8

How To Set Up An Inverter

Operating Instructions

Oil - kerosene burners


TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

How To Use A Power Supply On A Powerline 2.2 (Ai)

Operating Instructions. Room temperature controller

Phone: Fax: Web: info@clrwtr.com

Electric Rotary Actuator - On/Off or programmable control actuator

Digital Keypad Use s Manual

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

7 Lighting Technology

Modular I/O System Analog and Digital Interface Modules

Technical Information

Solid-State Timer H3G

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Operating instructions IV / 2007

H45 LED - Direct and indirect pendant

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Installation Instructions. Thermo Call TC3

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

ACS-30-EU-EMDR-10-MOD

OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.

Danfoss Link Mobile Phone Butler

Drayton Digistat +2RF/+3RF

IH E Sigma Island 90

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions


FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Instruction Manual for Operating Panel 301 and 302

Mureva Assembly surface mounted wiring devices

Conlift1, Conlift2, Conlift2 ph+

OZW30. Central Unit SYNERGYR

Infrarot-Bewegungsmelder IP44

Thermo Top - Troubleshooting Tree

Automatic Bypass Control AVDO

MovinCool Office Pro Series. The Portable Spot Cooling Solution

SELECTION, APPLICATION AND MAINTENANCE

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

E2 Series Electric Furnaces

4 Posiflow Proportional Solenoid Valves

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

CELO5. User & Installation Manual.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Digital input modules

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Elektromotoren und Gerätebau Barleben GmbH

3/2 Solenoid Cartridge Valve, Size 6

EBDSPIR-PRM, EBDSPIR-PRM-IP

Electronic Pressure Switch EDS 300

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

SMS 4 / SMS 5 safety mat Product information

TECHNICAL DATASHEET Incremental Encoder RI 58-H

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Transcription:

Oil Burner Controls type BHO 64 and LOA 44 Catalogue 5 Contents Application... page 2 Design... page 2 Variants and Application... page 2 Functions BHO 64A, 64, 64.1... page 3 Measuring of Flame Sensing Current... page 4 Terminal Ratings... page 5 Technical Data... page 5 Base, Code no... page 6 Electrical Connections... page 7 Code Numbers and Function-Times... page 8 Dimensions... page 9 Adapter... page 10 BK.21.A2.02 11-1998 1

Quality and environmental management system ISO 9001 ISO 14001 Danfoss A/S Burner Components Division operates a Quality- and Environmental Management System which has been certified to ISO 9001 and ISO 14001. Application The BHO series is for use with photo unit type LD or LDS on oil burners with intermittent operation in accordance with DIN 4787 and ISO 3544. BHO 64A, 64, and 64.1 are for oil burners with a capacity of up to 30 kg/h. LOA 44 is for oil burners with a capacity higher than 30 kg/h and hot air units. All types can be used on single and two-stage burners. All types meet the undervoltage protection requirements of ISO 3544 and European standard E 230. Design All oil burner controls are based on the familiar bimetal principle which controls burner start. An electronic amplifier adapts the current from the photo unit. Photo unit LD/LDS is designed to monitor yellow-flame oil burners. The controls consist of an upper part which houses the function elements named above and a base that contains all electrical connection facilities. There is a plug connection between the upper part and base. They are held together by a spring system. The two parts can be separated by inserting a screwdriver down in the side slots in the upper part. See fig. 4 page 6. Variants and application The BHO series is for use with single or twostage burners with prepurge, pre-ignition and post-ignition. BHO 64 is for burners with preheater where burner-start is conditional on the preheater thermostat, but continued burner operation is not conditional on the preheater thermostat. BHO 64 supersedes BHO 61 and BHO 62 and is thus used as a replacement of these units. BHO 64.1 has shorter prepurge and pre-ignition than BHO 64, otherwise they are identical. BHO 64A gives the option of short or long post-ignition. The design of the F-circuit gives a changed flame signal (min. 35 µa). LAO 44 is for use with oil burners (yellowflame) with a capacity greater than 30 kg/h, and with hot air units. LAO 44 is for use when replacing BHO 25 (new base), BHO 1 WLE and BHOV 1 WLE. Use adapter BHA 11/12. (Old type photo resistors must be replaced with new ones). 2 BK.21.A2.02 11-1998

Symbols In this catalogue the following symbols are used to explain the electrical function diagrams. Boiler thermostat External alarm High temperature cutout Ignition unit Phase lead Neutral lead Burner motor Solenoid valve Oil preheater Oil preheater thermostat Photo unit Relay Fig. 1 Function BHO 64A, 64, 64.1, LOA 44 Fig. 2 Normal start When thermostat TR makes, voltage is applied to terminal 1. If no oil preheater is used, terminals 8 and 3 must be linked. If there is an oil preheater, it receives voltage via terminal 8. When the preheater thermostat, OTR, makes the connection to terminal 3, the burner motor starts. At the same time the control timer circuit (bimetal heating element) receives voltage via contact set tz1 and pre-purge time with pre-ignition (terminals 6/7) starts. After prepurge time, contact set tz1 changes over so that contacts d-e break and c-d make. This cuts in valve 1 via terminal 4. When the flame is established, relay FR pulls in thereby breaking contacts a-b. The bimetal heating element TZ is thus cut out and the programme begins to cool down. At the same time, contact fr makes to ensure continued operation of the burner if the preheater thermostat breaks. When relay FR pulls in, a locking arm holds contacts c-d closed. When the bimetal has cooled down, the programme will have returned to its initial position where contacts a-b break and ignition is cut out. At the same time contacts d-e make so that valve 2 receives voltage via terminal 5. BK.21.A2.02 11-1998 3

False light at start In the event of false light, relay FR pulls in and the locking arm prevents contacts c-d from making. Therefore heating of the bimetal continues until contact set tz2 changes over from position a to position b. The system is thus blocked and there is voltage on alarm terminal 10. The control can only be reconnected when the bimetal has cooled down after a minimum of 50 s. The sensitivity of the flame circuit is increased during prepurge time. No flame at start If no flame is established when contact set tz1 makes contacts c-d, relay FR does not pull in and the control blocks when safety lockout time elapses. Flame failure during operation If the flame fails during operation, relay FR drops out and instantaneously cuts off voltage to the oil valves. The control immediately begins a new start with prepurge and pre-ignition. If the flame is not established before the safety lockout time elapses, the control blocks. If flame failure occurs in the interval between when valve V1 and valve V2 cut in, the flame relay drops out and the control tries to restart, i.e. there is still voltage on 4 and terminal 6/7. Undervoltage protection Undervoltage-protected controls incorporate an extra electronic circuit that protects the unit if dangerous undervoltage (<165 V) blocks burner start. No oil is released and the safety switch cuts out the burner. If undervoltage occurs in an operating period, the burner will run its period of operation until the thermostat cuts out. Restart is not possible for as long as undervoltage persists. Measurement of current through photo unit Measurement of current through photo unit The photo current is measured with a direct current ammeter in series with the photo unit (+ pole on terminal 12. Max. 5 kω internal resistance in measuring instrument). The photo current must be between 65 µa and 200 µa at 220 V and 75 µa and 220 µa at 240 V. With no flame, the measured photo current must be 5µA at 220 V and 6µA at 240 V. Fig. 3 BHO 64A min. 35 µa BHO / 64.1 /LOA 44 min. 65 µa Terminal rating Terminal Max. operating current Comments 1 5 A Max. current applied 3 5 A Incl. burner motor and preheater 4 1 A Without solenoid valve max. 4 A 5 1 A 6/7 2 A 8 5 A 10 1 A 4 BK.21.A2.02 11-1998

Technical data Rated voltage *) 220/240 V~ Operating range *) 187-264 V~ Frequency 50-60 Hz ± 6% Consumption Reset Reaction time on flame failure Mains fuse Cable connection, page 6 Approx. 3 VA After min. 50 s Max. 1 s Max. 10 A Ambient temperature -20 to +60 C Installation Any position Plate for five Pg 11 screwed cable entries Plate with knockouts Enclosure IP 40 Flame monitoring Photo unit LD or LDS Max. cable length between BHO and LD/LDS 20 m (installed separately) Sensitivity with photo LD : average 6 lux. Better than 20 lux unit during operation LDS : average 2 lux. Better than 3 lux Min.photo current during operation**) BHO 64/ 64.1 65 µa at 220 V, 75 µa at 240 V Max. photo current without flame } LOA 44 5 µa at 220 V, 6 µa at 240 V Min.photo current during operation**) Max. photo current without flame } BHO 64 Ambient temperature LD/LDS *) See types and code numbers, page 8 **) Max. 5 kω internal resistance in measuring instrument 35 µa at 220 V, 40 µa at 240 V 5 µa at 220 V, 6 µa at 240 V 20 to +70 C BK.21.A2.02 11-1998 5

Base The base has 12 terminals which accept the plug connector in the control upper part. In addition it is fitted with: Three extra neutral terminals connected to terminal 2. Four internally connected earth terminals for connection direct to the burner housing via a grounding plate. Two loop terminals marked 31 and 32. Two Ø5.4 holes for fixing the base to the burner. Two different front plates are available for the base, both with knockouts: 057H7011 for cable entry with cable relief 057H7012 for screwed cable entries. The upper part and base are kept together by a spring system. The upper part can be removed by pressing a screwdriver down into the slot, see fig. 4. Fig. 4 Miscellaneous Description Type Code no. Comments Base 057H7010 Frontplate 1) 057H7011 For five Pg 11 screwed cable entries Frontplate 1) 057H7012 Side holes : One 8.8 mm/ 17.5 mm Front holes : Three 7 mm + oval 6 20 mm Adapter 2) BHA 11/12 057H7020 For service market 1) Replaceable front plate, with knockouts. 2) For service market. 6 BK.21.A2.02 11-1998

Electrical Connections BHO 64A BHO 64 / 64.1 BHO 64A BHO 64 / 64.1 LOA 44 LOA 44 BK.21.A2.02 11-1998 7

Code numbers Controls Function Times (s) Rated Under- Prepurge Post- Interval Safety Type Code no. voltage voltage t1* ignition V1-V2 lockout protection time V t3 t3n t4 t2 max. BHO 64A 057H7030 220/240 x 13 ** 2/15 15 10 BHO 64 057H7036 220/240 x 13 15 15 10 BHO 64.1 057H7037 220/240 x 6 20 20 10 LOA 44 057H7040 220/240 x 25 2 5 5 * Prepurge time and pre-ignition time are the same. ** BHO 64A has post-ignition as an option terminal 6 gives 15 s terminal 7 gives 2 s Photo units Description Type Code no. Cable length L [mm] Comments Photo unit LD 057H7079 780 Long housing Normal sensitivity Black Photo unit LD 057H7080 270 Standard housing Normal sensitivity Black Photo unit LD 057H7081 500 Standard housing Normal sensitivity Black Photo unit LD 057H7082 800 Standard housing Normal sensitivity Black Photo unit LD 057H7083 2000 Standard housing Normal sensitivity Black Photo unit LDS 057H7084 270 Standard housing High sensitivity Red Photo unit LDS 057H7085 500 Standard housing High sensitivity Red Photo unit LDS 057H7086 270 Long housing High sensitivity Red Photo unit LDS 057H7087 520 Long housing High sensitivity Red Photo unit LDS 057H7090 700 Standard housing High sensitivity Red Photo unit LDS 057H7091 350 Standard housing High sensitivity Red Photo unit LDS 057H7092 800 Standard housing High sensitivity Red Photo unit LDS 057H7093 500 Long housing extra High sensitivity Light blue Photo unit LDS 057H7094 500 Long housing extra High sensitivity Light blue Photo unit LDS 057H7095 800 Special housing High sensitivity Red Photo unit LDS 057H7100 270 High sensitivity spec. type Red long housing (QRB1S) Colour Flange Flange Clamping ring See page 9. Basepart, see page 6. 057H7070 057H7071 057H7072 Accessories Service kit code no. 057H7022 contains the following components: Description Code no. Comments BHA 11/12 057H7020 Adapter Photo unit 057H7087 Elongated housing and high light sensitivity Flange 057H7071 As the old LD photo unit Clamping ring 057H7072 8 BK.21.A2.02 11-1998

Dimensions BHO Control with base Front plate 057H7011 Base 057H7010. Hatched part is interchangeable with either of the front plates below. Front plate 057H7011 Front plate 057H7012 LD/LDS Short housing H = 50 mm Long housing H = 65.5 mm Cable length L = se side 8 057H7070 057H7071 057H7072 BK.21.A2.02 11-1998 9

Adapter The new series of controls has 12 connection terminals and replace BHO 11/12 series, and the BHO 1, BHO 3, BHO 4 which all have 9 connection terminals. To make servicing easier, Danfoss supplies an adapter, type BHA 11/12, which can be mounted in the old base. Then, with light finger pressure, the new control can be mounted on the adapter. The adapter can be used for all controls with the same terminal arrangement as BHO 11/ 12, 57H1, 57H3, BHO 1, BHO 1 WLE, BHO 3, BHO 4, BHO 4 WLE. The adapter cannot be used with BHO 15 and BHO 25. To ensure reliable operation, the photo unit should be replaced with the new type LD/LDS when an adapter is used. Using an adapter when replacing a control Upper part with 12 terminals Adapter BHA 11/12 Base with 9 terminals Adapter + BHO 64 assembled has the same height as the BHO 11/12 upper part. 10 BK.21.A2.02 11-1998

BK.21.A2.02 11-1998 11

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 12 BK.21.A2.02 11-1998 Produced by Danfoss G1 advertising agency 98.12 FO-Bi.CCB