QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Similar documents
Digital input modules

TX OPEN RS232/485 module

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Product and Application Description

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Duct Humidity Transmitter

PXM20-E. Operator unit DESIGO PX

Room Temperature Sensors

PCS0100en Persy Control Services B.V. Netherlands

RRV934. Multi-controller. Synco living

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Drayton Digistat +2RF/+3RF

Flush-mount room temperature sensor AQR2531ANW.

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Electronic Control Devices The European Product Catalogue 2007

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

OZW30. Central Unit SYNERGYR

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

T0118 T2118 T3118. Instruction Manual

T7560A,B,C Digital Wall Module

Product and functional description

VAV compact controller KNX / PL-Link

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

OZW V2.0. Web server. Synco TM, Synco TM living

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Digital inductive conductivity transmitter

Air damper actuators

Inwall Room Temperature Unit

Electronic Control Devices The European Product Catalogue 2007

Automation stations modular model

3873P01. Room controllers. For fan-coil applications FC-10, FC-11, FC12 with Konnex bus communications (S-mode and LTE mode)

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Proportional pressure regulators VPPE

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Flush-mounted room thermostats

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

HMI display Installation Guide

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

FIREDEX Conventional Fire Panels

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

VAV compact controller KNX / PL-Link

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Automation stations modular series

AXIS T81B22 DC 30W Midspan

OZS Web server. For LPB/BSB plants

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Processor. Installation Guide

KNX Panasonic Air Conditioners

IntesisBox KNX Mitsubishi Heavy Industries AC

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Heating Controller. Building Technologies HVAC Products

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

IFS SP-PoE Splitter User Manual

Adjustable room thermostat for heating only or cooling only systems

HERZ-Thermal Actuators

IntesisBox Modbus Server SAMSUNG Air Conditioners

aseries A13B Mini Bullet Camera User Manual

IN-OUT Thermometer with Cable Free Sensor and Clock

Input module, input/output module

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

StructureScan HD Module. Installation Guide ENGLISH

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Dear Customer! Thank you for choosing our product.

=============================== WARNING

How To Use A Power Supply On A Powerline 2.2 (Ai)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

CompactLogix Power Supplies Specifications

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Waveguide Access Point WGA631. Product Guide

Manual. Simrad StructureScan LSS-1 Sonar Module. English

I STAR COMPUTER CO., LTD

ACS-30-EU-EMDR-10-MOD

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

PHOENIX CONTACT Features

Installation Instructions. Thermo Call TC3

Building Technologies

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Applied Electronics. Commercial Dimming System UPDATE NOTICE

T5000 T000 LCD Digital Fan Coil Thermostat

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Portable Air Conditioner

Transcription:

1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature measurement Buttons for adjustment of the room temperature setpoint Rocker switch for mode selection ( / Auto) and for manual control of the fan in fan-coil systems (up to 3 speeds) LCD with room temperature and control mode display Panel for configurable buttons for the operation of lighting and blinds Off-button ( ), to switch room lighting off and set HVAC system to an energysaving mode LONMARK -compatible bus communications Power supply via the two-wire bus (LONWORKS bus, LPT-10) Socket for RXT10 commissioning and service tool CA2N1648en_04 05.03.2012 Building Technologies

Use The flexible room unit is used in conjunction with the Desigo RXC room automation system for measurement of the room temperature and for integrated operation of HVAC, lighting and blinds. The HVAC functions are identical to those of the QAX34.1 room unit. The functions for operating lighting and blinds can be configured flexibly to match the requirements in the room. This involves fitting the required rocker switches and downloading the associated application software (referred to further on as the application ). The various applications are described individually in the Desigo RXC Applications library, CA2A3810 (V1) or CA110300 (V2). The flexible room unit is delivered in its unconfigured state (see Ordering ). The room units must be fitted with buttons/rocker switches and loaded with the application at the commissioning stage. The latter process is carried out with the RXT10 commissioning and service tool (see Commissioning notes ). Type summary The flexible room unit is available in two basic versions, which differ only in the number and type of buttons/rocker switches supplied. 80067 A QAX50 2 x + 4 x 3 x 4 x 1 x 2 x 80068 A QAX51 2 x + 1 x 4 x 3 x 1 x 3 x Type QAX50 is used for all applications involving on/off lighting control. Type QAX51 is required for dimmer control. Product No. Stock number Designation QAX50.5/C000 S55623-H114 Flexible room unit (on/off lighting control) QAX51.5/C000 S55623-H115 Flexible room unit (dimmer control) 2/10

Ordering When ordering, please specify the quantity, product name, type code and configuration. Unconfigured room units Unconfigured units are available only in the basic versions shown under Type summary above. The configuration code for these units is C000. Example: 7 Flexible room units QAX51.5 / C000 Button sets The two different button sets can also be ordered separately: Set A: SAP ordering No. 4268 277 30 (on/off lighting control) Set B: SAP ordering No. 4268 277 40 (dimmer control) Equipment combinations The QAX50 and QAX51 are primarily used in conjunction with the RXC30 / RXC31 / RXC38 room controllers and the associated extension modules, types RXC40 and RXC41. The room units are also used in conjunction with the RXC20, RXC21, or RXC22 for fancoil applications. The flexible room units can also be used for the control of lighting and blinds (and to a limited extent HVAC) in conjunction with LONMARK -compatible third-party devices. Mechanical design The room unit is designed for mounting on a recessed conduit box. The bus cable is connected to the unit from the rear with a plug-in connection. Essentially, the flexible room units comprise a housing and base unit, connected by releasable snap-fittings. The housing accommodates a printed circuit board, room temperature sensor element, buttons for setpoint adjustment, mode selection and fan-speed control, the LCD panel, a configurable control panel, a plug-in connector for the bus and a socket for the RXT10 commissioning and service tool. The configurable control panel incorporates two rubber membranes and a total of 10 contact points. The contacts are operated by the buttons and rocker switches fitted into the panel. The flexible room unit has a plastic housing and a galvanized steel mounting plate. Mounting plate 80075 Housing Plug-in connector for bus Socket for commissioning and service tool 3/10

Operator controls and display 80069 A Buttons for adjustment of the room temperature setpoint Room temperature and control sequence (heating / cooling) display Display of current control mode or current fan speed Rocker switch for selection of control mode and fan speed Configurable control panel (example of configuration) Note The actual functions of the operator controls and display panel are determined by the downloaded application. The description below covers all the possible options. Rocker switch for mode selection and fan-speed control The control mode of the connected room controller can be selected with the rocker switch. The same switch is used for manual control of the up to three fan speeds. Pressing once in the direction of the left arrow switches one stage to the left, and pressing once in the direction of the right arrow switches one stage to the right. The current control mode or manually-selected fan speed is indicated in the display panel by a horizontal bar below the associated symbol. Position Fan speed control 1) Control mode 1) Fan controlled automatically by room controller Fan controlled automatically by room controller Manual, fan speed 1 Manual, fan speed 2 Manual, fan speed 3 Pre-comfort or Economy (according to central control) Comfort 1) For function descriptions of the relevant HVAC applications refer to the Desigo RXC Applications library, CA2A3810 (V1) or CA110300 (V2). Note The operation of this rocker switch has no effect on the control of lighting or blinds. Buttons for room temperature setpoint adjustment Press the button once to switch from a display of the current room temperature to a display of the setpoint. Each further operation of the + or button raises or lowers the setpoint by 0.5 K or 1.0 F. The unit of measurement and the maximum allowable adjustment range is determined by parameters in the application software. 4/10

LCD display In normal operation, the following may be displayed (depending on the application parameters) For details refer to the Desigo RXC Applications library, CA2A3810 (V1) or CA110300 (V2).: Display element (examples) Description Room temperature in C (resolution 0.5 C) Room temperature in F (resolution 1.0 F) Digital display of setpoint adjustment (displayed only while relative adjustment is in progress). Digital display and scale (displayed only while absolute adjustment is in progress) Control sequence: Cooling Control sequence: Heating Room units with mode and fan-speed selection enabled: Fan speed 1: ON In room units allowing mode selection only: Auto: ON Configurable control panel The configurable control panel can be fitted according to requirements with a variety of buttons and rocker switches. The following options are available: Large button for on/off control of lighting Standard button for on/off control of lighting Rocker switch for on/off control of two lighting units Rocker switch for dimmer control Rocker switch for control of blinds OFF button: Switches all room lighting off Switches the connected room controller to Pre-comfort or Economy Blank plate (no function) Note Flexible room units configured with an OFF button incorporate the following additional function: If the connected room controller is in Pre-comfort or Economy mode, it will switch to Comfort as soon as any of the rocker switches or buttons on the room unit are operated. 5/10

Removing the buttons/rocker switches 80096 A Search LED Service LED There are two LEDs under the top button/rocker switch on the configurable control panel. These remain permanently on so that the unit can be located more easily in the dark. The yellow Service LED is fitted under the last button/rocker switch on the configurable panel and indicates the status of the room unit by means of different flashing patterns (see the RXT10 user manual, CM110669). Disposal The devices are classified as waste electronic equipment in terms of the European Directive 2002/96/EC (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Engineering notes The flexible room unit is connected to the LONWORKS bus by a two-wire twisted cable and receives its power via the bus cable. This cable must be connected to a central bus power supply in accordance with LPT-10 (see the Installation guide, CA110334). For mounting, a standard recessed conduit box or an aperture of the equivalent size is required. Mounting notes The room unit must be mounted on a recessed conduit box Mount on a flat surface with a maximum offset of 1 mm The base plate should be fixed with screws, max. diameter 3.5 mm Do not mount in recesses, shelves, behind curtains or doors, or above or near heat sources. Avoid exposure to direct sunlight or draughts. The electrical wiring conduit must be sealed where it joins the room unit, to prevent the occurrence of draughts in the conduit which could affect the sensor. The specified ambient conditions must be complied with. Mounting instructions are printed on the room unit packaging. 6/10

1 80091 A 2 Fit to top rail (1) and snap-mount on bottom rail (2) Installation notes Local installation regulations must be observed. Do not route mains voltage cables to the conduit box. Use only the original bus plug. STOP Warning The room unit is not protected against connection to AC 230 V. Commissioning notes The QAX50 and QAX51 flexible room units are commissioned with the RXT10 commissioning and service tool. This is connected to the LONWORKS bus via the tool socket. The RXT10 user manual (CM110669) contains a step-by-step commissioning procedure for the entire Desigo RXC range. Response on start-up When the supply voltage is connected (via the LONWORKS bus) the room unit runs a self-test, during which all segments of the LCD are enabled. At the end of the self-test, the LCD panel reverts to the normal display. Service pin function The service pin function, which is used to transmit the identification number of the unit to the bus can be enabled by simultaneously pressing the two setpoint adjustment buttons and the mode selection/fan-speed rocker switch (to the left or right). The LCD panel displays for approximately 1 to 2 s in acknowledgement. 80112 Press simultaneously Wink function display If the RXT10 commissioning and service tool is used to issue an identification command to in the room unit (wink function), the LCD panel responds with the display. This display persists for a maximum of 64 s or until a rocker switch or button is operated. The room unit then reverts to the normal display. 7/10

Notes on operation During normal operation and commissioning, the LCD panel also serves to display error messages: Display Description Room temperature sensor outside range 0... 40 C Technical data Power supply Operating voltage SELV / PELV Max. DC 42 V The Room unit receives its power via the LONWORKS bus in accordance with specification LPT-10 Power consumption Max. 0.3 W Function data Temperature sensor Measuring element NTC resistor Measuring range 0... 40 C Response time 9 min Measuring accuracy (5... 30 C) ± 0.5 K Measuring accuracy (25 C) ± 0.25 K Setpoint correction Correction range (defined by application Max. ± 10 K (default ± 3 K) parameters) Display Type LCD Functions displayed Room temperature Setpoint adjustment Operating status Manually selected fan speed Control sequence (heating / cooling) Configurable operator panel Number of contact points 10 Max. number of buttons/rocker switches 5 Functions On/off control of lighting Lighting dimmer control Blinds up/down and adjustment of slat angle OFF button Interfaces LONWORKS bus Interface type LONMARK -compatible Transceiver LPT-10 Baud rate 78 kbit/s Bus topology and bus termination See Installation guide, CA110334 Cable connection Connection terminals (plug-in screw terminals)solid or stranded conductors 2 x 1.0 mm 2 Single cable lengths See also Installation guide, CA110334 LONWORKS bus Max. 500 m Cable type See Installation guide, CA110334 Tool connecting cable Max. 3 m (manufactured) 8/10

Housing protection standard Protection standard to EN 60529 IP 30 Protection class Insulation protection class III Ambient conditions Operation IEC 721 Ambient air conditions Class 3K5 Temperature 0... 50 C Humidity < 85 %rh Mechanical conditions Class 3M2 Transport IEC 721 Ambient air conditions Class 2K3 Temperature 25... 70 C Humidity < 95 %rh Mechanical conditions Class 2M2 Standards and directives Product safety Product standard Automatic electronic controls for household and similar use EN 60730-1 Electromagnetic compatibility Immunity (industrial & residential) EN 60730-1 Emissions (residential) EN 60730-1 compliance Meets requirements of EMC directive 2004/108/EC UL compliance UL916 C-Tick conformity (EMC) AS/NZS 61000-6-3 Environmental compatibility The product environmental declaration CA2E1648 contains data on materials composition, packaging, environmental benefit, disposal ISO 14001 (Environment) ISO 9001 (Quality) Dimensions See "Dimensions" Color Front plate and operator control panel NCS S 0502-G, RAL 9003 signal white Buttons/rocker switches for setpoint adjustment RAL 7035 light grey and mode selection Weight Excluding packaging 0.175 kg Connection terminals The LONWORKS bus connection terminals are removable, so that if the bus cable is looped, the room unit can be separated from the bus without causing an open circuit. Terminal layout CLA CLB LONWORKS bus, Data A LONWORKS bus, Data B Tool socket CLA CLB 9/10

Dimensions All dimensions in mm 10/10 2000-2012 Siemens Switzerland Ltd. Subject to change