System Installation guide

Similar documents
Quantec Wiring Instructions

Application/Connection Examples

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Product and functional description

KNX Lighting Control System

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Modular I/O System Analog and Digital Interface Modules

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Using installed Fieldbus Wiring to carry Ethernet Communications

connecdim Gateway G1 Ethernet TCP/IP to DALI

Installation manual. Version

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Combi B Alarm box. Mounting instructions

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

SYSTEM 4C. C R H Electronics Design

Lighting Control Overview

MechoNet TM Network Interface (MNI) Specification Submittal

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

EMBEDDED ACCESS CONTROL Hardware Installation Guide

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

EBDSPIR-DD, EBDSPIR-DD-IP

Repeaters and Mimics Data Sheet

DALI RC BASIC SO. Control unit Operating instructions

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

SYSTEM 45. C R H Electronics Design

EDI Distributor Control Interface Wiring and Setup Instructions

Power Supply and Cabling Options. SmartTrak 100/101/140

MOTION COORDINATOR MC206X Quick Connection Guide

Inverter / Charger Installation General Operations and AC and DC Connections

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

conventional system operation

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

IRIS Touch 600 Range Dialler Installation Manual. Version 1.3

WD-AMX Water Detection Controllers

LDG DTS-4/4R Desktop Coaxial Switch / Remote

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

TS510 & TS500. Installation & User Guide. Compatible Equipment

LocoNet, the Digitrax Difference

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

MSL1000 Monitored Serial Link Interface Manual V1.01

Contents. Document information

IO-RM3 3-Stage Relay Module

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

SECTION LOW VOLTAGE LIGHTING CONTROLS

ALARMLINE ANALOGUE Linear Heat Detection System

The ABCs of Power Over Ethernet

Heating and Hot Water Services Controls General Technical Specification

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Switch board datasheet EB

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Product Information Fire alarm panel 8000 C

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

M-Bus Network Installation Notes

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

M1000 Process Alarm Monitor

Model: DC-A2IO Advanced HVAC Controller

THE INPUT/OUTPUT SYSTEM. Key Points

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

NC-12 Modbus Application

Digital input modules

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

IO-DIM6 6-Channel, Digital to Analogue Converters

MLC TM Maximum Productivity and Versatility for Control without Compromise!

WEB log. Device connection plans

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Thyristor-controlled power supplies and battery chargers

Installation guide H A. HSI hardwired system interface

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Copyrights 2010 Victron Energy B.V. All Rights Reserved

8 by 8 dot matrix LED displays with Cascadable Serial driver B32CDM8 B48CDM8 B64CDM8 General Description

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

NX safety stand-alone

HM-W536 Install Guide

200 Range Dialer Installation Manual. Version 1.0

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

KNX Powerline PL 110. KNX Association

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Maximum distance: 15m P/N DESCRIPTION NOTES

D200+ Auto-Dialler Installation/Operators Manual

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Future proof lighting management

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

Bluetooth HC-06 with serial port module Easy guide

Transcription:

System Installation guide Ligo System installation guide.doc Page 1 of 12

Contents 1 Introduction... 3 2 System Topology... 3 3 Control Elements... 4 3.1 LiGO Controllers... 4 3.2 IP Domain... 5 3.3 RS232/DALI interfaces... 5 3.4 DALI Power supplies... 5 4 DALI... 6 5 DALI Cabling... 6 5.1 Topology... 6 5.2 Conductors... 7 5.3 System Limits... 7 6 Override Connection... 8 6.1 Inputs:... 8 6.2 Outputs... 8 7 Pre Commissioning Checks... 9 8 Annex A Typical Panel Schematic and Layout... 10 Ligo System installation guide.doc Page 2 of 12

1 Introduction The LiGO system provides control and integration of lighting DALI control. Each LiGO controller can interface to up to 8 DALI loops. Multiple LiGO controllers can be linked via IP to integrate into a single complete system, which can be configured, monitored and controlled from a browser over an internal network or over the internet. 2 System Topology Ethernet RS232 RS232/DALI Interface DALI Power Supply DALI Loop Ligo System installation guide.doc Page 3 of 12

3 Control Elements The control elements of the system consist of The LiGO controller, its power supply, the RS232/DALI interfaces and DALI power supplies. These should be installed in suitable enclosures (see example right), in an accessible position preferably adjacent to the lighting distribution board(s) feeding the luminaires to be controlled by the system. Each panel should be fed from the 240V essential mains from supply via a 5A fused spur. An internal RCD socket should be provided to allow the configuration laptop to be plugged in. A typical schematic and layout are shown in annex A. 3.1 LiGO Controllers The LiGO controller is the main element of the control system. One or more controllers should be mounted in an enclusure together with their power supply, the required interfaces and DALI bus power supplies. Ligo System installation guide.doc Page 4 of 12

3.2 IP Domain LiGO controllers are connected together via an IP network. This can be a local private network, or part of another data network. An RJ45 data socket should be installed within 3m of each LiGO controller. An IP hub may be used to connect several LiGO controllers to an RJ45 network socket. For remote access and maintenance internet access should be provided to the LiGO network. 3.3 RS232/DALI interfaces Each LiGO has 8 TTY (serial ports) comprising RJ45 sockets. Tridonic SCI2 interface units convert between the serial signals from the LiGO controller and the DALI bus. A bespoke DALI/Triconv 1.2M 9way to RJ45 cable is available from Open Technology. 3.4 DALI Power supplies Each DALI bus requires a power supply. Tridonic PS DALI bus power supply may be used and should be installed in the control enclosureand connected at the interface end of the bus. Ligo System installation guide.doc Page 5 of 12

4 DALI What is DALI? Digital Addressable Lighting Interface is a lighting control method that allows for the remote switching and dimming of individual luminaires. Up to 64 fittings can be connected on a single DALI bus. Control signals are passed along a bus cable connected from fitting to fitting. Commands can be sent down the control cable to individual luminaries, or groups of luminaries, to switch them on or off and/or to dim them. DALI compliant luminaries are able to send status information (ECG errors/ lamp errors) back up to the next level control system (IP with LiGO). A 2-core (1.5mm2 max. 300m), polarity independent cable is connected from fitting to fitting using any topology (star, daisy-chain, etc). The nominal voltage on the DALI line is 16V (SELV). 5 DALI Cabling The electrical installation of lighting control systems with a DALI interface must be carried out by an authorised electrical engineer in accordance with the relevant power system regulations. 5.1 Topology DALI cabling can be wired in a free, radial topology (daisy chain, star, etc) Loops are NOT ALLOWED Live is permanent to all fittings (i.e unswitched) The same DALI pair may be connected to fittings that are on different phases Ligo System installation guide.doc Page 6 of 12

5.2 Conductors Can run alongside mains cables Minimum cross sectional area : 1.5mm2 Can be single cores, busbar or modular wiring Red and White insulation / sheathing Source voltage (at LCS Panel) : 16VDC All components to be disconnected before insulation resistance tests are undertaken 5 cores to each fitting (L,N,E & DALI pair) whether normal or emergency fitting. The polarity of the termination of the DALI pair at the light fitting is not important. 5.3 System Limits Maximum permissible cable length between any two DALI devices is 300m (with 1.5mm²) or 2V volt-drop. Example shows that the cable run distance from (X to Y) or (X to Z) or (Y to Z) or any point to the DALI/RS232 interface should not exceed 300m. Total loop resistance on longest run < 18 Ohms 300m X Z X 300m Z Addressing: Up to 64 DALI devices per DALI loop (e.g. Ballasts, EMPro inverters, sensors etc.) Y X Z Y X Z Current: Ballasts pull 2mA, and Sensors pull 6mA. Max current pulled by all devices on the loop is 200mA (Tridonic DALI PS). 300m 300m Select logical lighting circuits to group on to each DALI Loop. Y Y Ligo System installation guide.doc Page 7 of 12

6 Override Connection Each LiGO controller provides a 25 pin DIN socket giving access to 21 programmable I/O lines. Each of pins 1 to 21 may be configured either as an input to accept switches or as outputs to interface to other systems or operate loads. Plug shown 6.1 Inputs: Pins Switches and/or volt free contacts from other systems may be connected to any of pins 1 to 21 and these configured as inputs to provide override functions. 1k 1k 1k 23 Sw 1 These inputs may be configured for special functions such as Fire Alarm or emergency test. Sw 2 Sw 3 etc. 25 6.2 Outputs Pins Pins 1 to 21 may be configured as outputs to Drive 5v logic circuits or operate suitable The outputs can sink a maximum of 15mA in the low state. TTL level relays may be connected to provide isolated interfaces. Pin 23 provides a 5v Source supply 23 1 To other system To other system A suitable relay is the Crydom MPDCD3-B-MS11 which may be mounted in a DIN rail socket as shown below. 2 3 etc. To TTL input Ligo System installation guide.doc Page 8 of 12

7 Pre Commissioning Checks To enable the commissioning visit to site to be undertaken as requested the following points should be tested and documented during the final check of the installation: All parts of the system must be powered, and all DALI luminaires checked to ensure that they operate correctly and that the DALI bus is fully operational. 1. All mains wiring associated with the control panel and the luminaires in the area has been tested and certified in accordance with the current IEE Wiring Regulations and all of the control panels, field devices and luminaires forming the zone are energised (230v), with all MCB s and isolators on? 2. The DALI loop length is <300m (furthest distance device to device) and the loop resistance is <18 Ohms 3. The DALI loop has no short circuits (Red LED on SCI RS232/DALI interface on continuously if short circuit present) 4. The number of devices on each loop is within the required system limits (both addresses and current drawn). 5. All luminaires are on at full brightness (normal condition with power on and before commissioning) Any luminaires that are not lit should be rectified prior to commissioning. 6. Luminaires should have the lamps burnt in (operated at 100% for 200 hrs) before commissioning is undertaken. The Pre-commissioning checklist (see later) should be completed, signed off and returned to the commissioning agent at least 5 working days before commissioning is required Ligo System installation guide.doc Page 9 of 12

8 Annex A Typical Panel Schematic and Layout Ligo System installation guide.doc Page 10 of 12

NOTES: Ligo System installation guide.doc Page 11 of 12

LiGO System Pre-commissioning Check Sheet Issued By: Issue Date: Project: Project Number: To enable the commissioning visit to site as requested the following listed points must be completed, signed-off and issued to the commissioning office prior to the Engineer arriving on site. A completed copy of this form must be issued at least 5 working days before the scheduled visit date. Please carry out the following pre-commissioning checks: Are all of the LiGO panels, field devices and items of equipment forming this control panel zone installed and complete and the device limits adhered to? Has the mains wiring associated with the control panel in this area been tested and certified in accordance with the current IEE Wiring Regulations? Are all of the control panels, field devices and luminaires forming this zone energised (230v), with all necessary MCB s and isolators on? Has all of the DALI bus wiring been installed and terminated and cable length limits adhered to? Tick when Complete Are all light fittings operating with working lamps? When was the last of the 230v mains power to the lighting circuits energised? (with all lamps lit - 200 hour lamp burn-in required): Date: Time: ------------------------------------ ---------------------------------- Is safe access available to all devices and components forming part of the system to be commissioned? Will all ceiling tiles, access hatches, doors etc. be open or accessible for our works upon arrival to site? Will the system and areas be ready and available for commissioning on the date indicated below? Does Open Technology have your latest as fitted drawings? Please give ref: ----------------------------------------------------------------------------------- Commissioning is required to commence on: Date: Signed: Date: Print Name: Open Technology Ltd 2009 No. 1 Woodlands Court, Albert Drive, Burgess Hill, West Sussex, RH15 9TN, UK Tel: 0845 680 0303 Fax: 0845 680 0404 sales@opentechnologyuk.com