Experiment IX: Angular Correlation of Gamma Rays

Similar documents
Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

GAMMA-RAY SPECTRA REFERENCES

Introduction to Geiger Counters

Tutorial 4.6 Gamma Spectrum Analysis

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

The accurate calibration of all detectors is crucial for the subsequent data

Radiation Detection and Measurement

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

ORTEC AN34 Experiment 7 High-Resolution Gamma-Ray Spectroscopy

Atomic and Nuclear Physics Laboratory (Physics 4780)

ENERGY PER PHOTOELECTRON IN A COINCIDENCE LIQUID SCINTILLATION COUNTER AS A FUNCTION OF ELECTRON ENERGY. Donald L. Horrocks

CHAPTER 6 PHOTON COUNTING

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Frequency Response of Filters

Gamma and X-Ray Detection

Chapter 18: The Structure of the Atom

AN51 APPLICATION NOTE Revision 1

Calculation of Source-detector Solid Angle, Using Monte Carlo Method, for Radioactive Sources with Various Geometries and Cylindrical Detector

GRID AND PRISM SPECTROMETERS

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Radioactivity III: Measurement of Half Life.

Atomic Structure: Chapter Problems

ELECTRON SPIN RESONANCE Last Revised: July 2007

CHAPTER 11: Flip Flops

ISTITUTO NAZIONALE DI FISICA NUCLEARE

Lab 9: The Acousto-Optic Effect

Main properties of atoms and nucleus

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

INTERFERENCE OF SOUND WAVES

TIME OF COMPLETION NAME SOLUTION DEPARTMENT OF NATURAL SCIENCES. PHYS 3650, Exam 2 Section 1 Version 1 October 31, 2005 Total Weight: 100 points

CHAPTER 7 SCINTILLATION COUNTING

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

Counters and Decoders

Step Response of RC Circuits

Experiment 5. Lasers and laser mode structure

Sequential Logic: Clocks, Registers, etc.

Electrical Resonance

Nuclear Magnetic Resonance and the Measurement of Relaxation Times of Acetone with Gadolinium

Nuclear Physics. Nuclear Physics comprises the study of:

2, 8, 20, 28, 50, 82, 126.

The Phenomenon of Photoelectric Emission:

Basic Nuclear Concepts

Experiment # 9. Clock generator circuits & Counters. Eng. Waleed Y. Mousa

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

EDXRF of Used Automotive Catalytic Converters

Copyright 2007 Casa Software Ltd. ToF Mass Calibration

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Assessment Plan for Learning Outcomes for BA/BS in Physics

Signal to Noise Instrumental Excel Assignment

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Extended Resolution TOA Measurement in an IFM Receiver

Atomic Calculations. 2.1 Composition of the Atom. number of protons + number of neutrons = mass number

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

Gamma Ray Spectroscopy

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

Gamma-Ray Spectroscopy Dan Amidei and Ramón Torres-Isea

Measurement of Muon Lifetime and Mass Using Cosmic Ray Showers

Radiation Strip Thickness Measurement Systems

ABSORPTION OF BETA AND GAMMA RADIATION

Introduction to the Monte Carlo method

Chapter NP-5. Nuclear Physics. Nuclear Reactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 NUCLEAR REACTIONS 2.0 NEUTRON INTERACTIONS

How To Understand Light And Color

Understanding Poles and Zeros

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

X Ray Flourescence (XRF)

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

RF Measurements Using a Modular Digitizer

Module 13 : Measurements on Fiber Optic Systems

Name Date Class ELECTRONS IN ATOMS. Standard Curriculum Core content Extension topics

Calorimetry in particle physics experiments

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

E/M Experiment: Electrons in a Magnetic Field.

THE STATISTICAL TREATMENT OF EXPERIMENTAL DATA 1

Vacuum Evaporation Recap

Current Standard: Mathematical Concepts and Applications Shape, Space, and Measurement- Primary

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

A Digital Spectrometer Approach to Obtaining Multiple Time-Resolved Gamma-Ray. Spectra for Pulsed Spectroscopy. W. K. Warburton a

99.37, 99.38, 99.38, 99.39, 99.39, 99.39, 99.39, 99.40, 99.41, cm

In mathematics, there are four attainment targets: using and applying mathematics; number and algebra; shape, space and measures, and handling data.

So far we have investigated combinational logic for which the output of the logic devices/circuits depends only on the present state of the inputs.

Features. Applications

TOF FUNDAMENTALS TUTORIAL

Pesticide Analysis by Mass Spectrometry

Extraction Heights for STIS Echelle Spectra

Precision Diode Rectifiers

Fiber Optics: Fiber Basics

Introduction to X-Ray Powder Diffraction Data Analysis

University of California at Santa Cruz Electrical Engineering Department EE-145L: Properties of Materials Laboratory

Basic Electronics Prof. Dr. Chitralekha Mahanta Department of Electronics and Communication Engineering Indian Institute of Technology, Guwahati

Masses in Atomic Units

Gamma Ray Scintillation Spectroscopy

Transcription:

Experiment IX: Angular Correlation of Gamma Rays Curran D. Muhlberger University of Maryland, College Park (Dated: May 9, 2008) Using a pair of scintillation detectors and a coincidence circuit, we measured the angular correlation functions for γ-rays emitted from sodium and cobalt nuclei. Theoretical arguments predict that successive γ-rays emitted from the same spinning nucleus should be distributed anisotropically, and this is indeed what we obseve. Photons emitted via pair annihilation in sodium must exhibit a δ-function distribution to conserve momentum, and our measurements indicate that coincidence rates are strongly peaked at θ = 180 with a dropoff consistent with the finite size of the detectors. Furthermore, our Legendre polynomial coefficients of A = 0.0977 ± 0.0099 and A 44 = 0.0011±0.0125 are consistent with their theoretical values for 4-2-0 quadrupole-quadrupole transitions in nickel after adjusting for finite detector size. We also compared our data with the results of Monte Carlo simulations and found them to be in agreement. I. INTRODUCTION When two γ-rays are emitted in succession from an atomic nucleus, their directions are often correlated due to the physics of the emission process. In particular, when an excited nuclear state decays to the ground state through one or more intermediate states, the spin of the nucleus affects the angular distribution of the photons emitted during each transition. The relative probability that a photon will be emitted at an angle θ with respect to a previously emitted photon is denoted W(θ) and depends both on the angular momenta of the states involved in the transitions and on the multipole order of the emitted radiation. Dr. D. R. Hamilton derived the theoretical forms of W for dipole and quadrupole radiation and computed the relevant coefficients for all possible angular momenta [1]. 60 Here we experimentally verify these results for Co. Other nuclear processes, including electron-positron pair annihilation, can also produce correlated γ-rays. Sodium- in particular exhibits a simple angular distribution suitable for evaluating our detection apparatus. After undergoing β + decay (a 90% scenario), the resulting positron is captured by an electron, and the pair annihilates to produce a pair of 511 kev γ-rays as diagrammed in Figure 1. As the momentum of the positronium system must be conserved, the photons must be emitted in opposite directions. Therefore, the angular distribution function for Na is given by W(θ) = δ(θ π) (1) Once we have calibrated the detection apparatus and coincidence circuit using the Na source, whose physics are well-understood, we can consider the more complicated case of cobalt-60. Through β emission, the cobalt nucleus decays into an excited state of nickel. This state then decays to the ground state though an intermediate state with a lifetime of 8 10 13 s, shown in Figure 2. The γ-rays emitted during these two transitions are thus effectively in coincidence. Assuming spin states of J 1,J 2,J 3 = 4,2,0 and quadrupolequadrupole transitions [2], the angular correlation function for 60Co is described by W(θ) = 1 + 1 8 cos2 (θ) + 1 24 cos4 (θ) (2) FIG. 1: Energy level diagram for the primary decay mechanism of sodium-. The half-life of Na is 2.6 yr and the initial β + decay occurs with 90% probability. or equivalently W(θ) = 1 + A P 2 (cos(θ)) + A 44 P 4 (cos(θ)) (3) where A = 0.1020, A 44 = 0.0091, and P n represent the Legendre polynomials. Note that W(θ) here gives the ratio of the likelihood of detecting a photon at an angle θ to the likelihood of detecting one at an angle of 90. By experimentally measuring these angular correlation functions, we not only test the validity of the theory of correlated emission but also gain insight into the angular momenta of these decay processes. We wish to detect not only the presence of γ-rays (with near-perfect efficiency), but also their energies. To do so we employ two NaI(Tl) scintillation detectors. When a highenergy γ-ray interacts with the sodium iodide crystal it produces a low-energy (visible) photon that is reflected towards an attached photomultiplier tube. Here it releases an electron from the cathode via the photoelectric effect, causing a cascade that is multiplied at each dynode in the tube to produce a voltage pulse at the anode whose height is proportional to the energy of the initial γ-ray.

2 Scintillator A Scintillator B LeCroy 428F Quad Linear Fan-In/Fan-Out LeCroy 623B Octal Discriminator Tennelec TC412A Variable Delay LeCroy 428F Ortec 570 Amplifier MCA LeCroy 365AL 4-Fold Logic Unit LeCroy 688AL Level Adapter Ortec 426 Linear Gate Ortec 871 Timer and Counter FIG. 2: Energy level diagram for the decay of cobalt-60. Half-life is 5.2 yr, and the intermediate state lives for 8 10 13 s. FIG. 4: Schematic of coincidence circuit indicating specific models of relevant NIM modules and their connections. Radioactive Source NaI Detector 10" θ 90 135 180 that would only pass a sum of signals detected simultaneously by both detectors. A discriminator set to its minimum threshold of 30 mv was used to generate logic pulses from detected photons. These were passed through a variable delay and then to a 4-fold logic unit triggering a gate between a linear fan-in and a multichannel analyzer (MCA). In this way, the sums of pulses caused by correlated γ-rays were amplified and delivered to the MCA while extraneous signals were filtered out. We also kept a count of coincidence events to verify the results of the MCA. Figure 4 describes the exact components and connections used in the construction of this circuit. FIG. 3: Schematic of detector array (top-down view). Components are drawn to scale. II. PROCEDURE In order to measure the angular correlation of various radioactive sources, we constructed a detector array composed of two NaI scintillation counters doped with thallium. The surface on which the detectors were placed was marked with angles in 5 increments between 90 and 195 with respect to a reference direction facing the first detector. A 10 in arc ensured that the detector faces were always a constant distance from the source, which was placed at the center. We were able to position the second detector at any of the marked angles along the arc to within σ θ = 0.45 and σ r = 1mm. Figure 3 presents a sketch of this detection apparatus. Not all photons produced by the radioactive sources represent pairs of emissions from the same nucleus. To limit our analysis to such pairs, we constructed a coincidence circuit To account for any relative delays between the two detectors, we measured the coincidence rate of a Na source (θ = 180 ) for various imposed delays in the two channels. The results are recorded in Table I and plotted in Figure 5, and from them we conclude that a delay of 16 ns in the signal from the first detector is necessary to synchronize the two channels. Furthermore, we see that the resolution of this coincidence circuit, measured as half the full width at half maximum of the plot, is 28 ns. The required imposed delay was verified and monitored throughout the experiment using a fast oscilloscope. Once the circuit was confirmed to be in-time, we could confidently measure the emission spectra of both the sodium and cobalt sources using the MCA. Placing the gate in Pulse Inhibit mode allowed us to measure the non-coincidence spectrum of sodium and thus perform a 2-point calibration of the MCA using its peaks at 511 kev and 1277 kev, as shown in Figure 6. We could further refine this calibration with measurements of the cobalt spectrum, plotted in Figure 7, which clearly show peaks at 1172 kev and 1333 kev.

3 TABLE I: Measurements of the coincidence rate at various imposed delays between the two detector channels. Positive delays correspond to a delay in the first detector s signal, while negative values indicate a delay for the second detector. Delay [ns] Counts per Minute Delay [ns] Counts per Minute -32 402 16 19255-28 595 20 19534-24 1079 24 19295-20 3999 28 19559-16 12082 32 19276-12 17621 36 18274-8 18857 40 13478-4 18928 44 5371 0 19057 48 1899 4 192 52 1320 8 19040 56 1209 12 19525 60 1100 Counts 1400 1200 1000 800 600 400 200 Sodium- Multichannel Analysis Channel # Detector A (Pulse Inhibit) Detector B (Pulse Inhibit) Coincidence (NORM) 0 0 200 400 600 800 1000 1200 FIG. 6: Emission spectra of sodium- for both coincidence and noncoincidence events. Non-coincidence spectra are plotted for both channels to check for equal gain settings. Coincidence Timings Cobalt-60 Multichannel Analysis Counts per Minute 0 5000 10000 15000 20000 Counts 300 250 200 150 100 50 Detector A (Pulse Inhibit) Coincidence at 180 (NORM) Coincidence at 90 (NORM) 0 0 200 400 600 800 1000 1200 Channel # FIG. 7: Emission spectra of cobalt-60 for both coincidence and noncoincidence events. 20 0 20 40 60 Channel A Delay [ns] FIG. 5: Plot of coincidence rate versus delay between the two detector channels. The full width at half maximum determines the resolving time of the coincidence circuit. III. DATA time required, several of these measurements had to be taken on different occasions. In such cases, a repeat measurement was made at θ = 180 so that the results could be scaled to match previously-taken data. Both the raw and scaled measurements are recorded in Table III. Due to potential saturation of the linear fan-in unit (indicated by the sharp edge at the right of Figure 7), the coincidence peak in the cobalt spectrum was difficult to define in a consistent manner. Therefore, With the coincidence circuit and MCA properly calibrated, we proceeded to measure the angular correlation of coincidence rates for both Na and Co. For sodium, we counted 60 the number of events in 1 min starting at θ = 180 and decrementing θ by 5 until the rate fell to zero. These measurements are tallied in Table II. For cobalt, we took measurements over 30 min intervals traveling from θ = 180 to θ = 90 at 30 increments, then from θ = 105 to θ = 165 in order to help compensate for temporal effects. Unfortunately, due to the long integration TABLE II: Coincidence rates for Na in 5 increments. Counts were recorded over 60 s. Net areas (and uncertainties) were computed using the MAESTRO MCA emulator. θ [ ] Counts Net Area σ Net Area 180 19460 16450 200 175 12736 10454 168 170 4443 3272 107 165 443 139 31 160 304 0 1

4 TABLE III: Coincidence rates for 60Co in 15 increments. Counts were recorded over 30 min. Data taken on different occasions are scaled based on overlapping measurements (not shown). θ [ ] Raw Counts Corrected Counts σ Counts 180 8657 93 165 8687 8542 171 150 8501 92 135 8434 8294 167 120 7695 88 105 7329 7611 121 90 7598 87 10" 17 Photopeak Counts 0 5000 10000 15000 Data Monte Carlo Angular Correlation for Sodium 160 165 170 175 180 Angle [deg] 1 FIG. 8: Analysis in 2 dimensions of the effects of finite detector resolution on the ability to detect γ-rays emitted by pair annihilation. In particular, given the size of our detectors, the coincidence rate should drop to zero around θ = 15. we based our analysis on the total count of coincidence events, using Poisson statistics for the error. As the events in the peak clearly dominate the total spectrum, the effects of this choice on the results should be negligible. IV. 13 RESULTS Ideally, the angular correlation function for Na would be a δ-function centered at θ = 180 (Equation 1). Due to the finite angular resolution of the detectors, however, this function is smeared over a range of detector angles. A 2-dimensional analysis conducted in the central plane of the detectors, pictured in Figure 8, indicates that the coincidence rate of photons emitted in opposite directions should rapidly approach zero between θ = 13 and θ = 17 given the size and separation of our detectors. Our observations of the angular dependence of coincidence events from sodium, plotted in Figure 9, agree with this analysis. The data is strongly peaked at θ = 180 and drops to zero between θ = 15 and θ = 20. To further test the extent to which our measurements agree with the theory, we developed a Monte Carlo simulation package able to accommodate custom detector arrays and radioactive sources. Approximating our detectors as circular discs with 100% efficiency, we computed the expected relative coincidence rates for Na and plotted them along our data in FIG. 9: Measurements and uncertainties of the angular correlation function of sodium- based on net photopeak area. Monte Carlo simulation results provide an indication of the effects of finite detector resolution. Figure 9. The two results agree with each other at the extremes, but diverge for intermediate angles. This is most likely explained by the dependence of the real detectors efficiency on the incidence angles of the incoming γ-rays. Non-normal γ-rays are less likely to interact with the NaI crystal, which is consistent with the more rapid decrease in coincidence rates compared with the simulation. 60 As the theoretical angular correlation function for 60 is finite and smooth, we can fit our measurements to a function of similar form (specifically, a scaled version of Equation 3) and evaluate the agreement of the resulting coefficients with theory. Using the Levenberg-Marquardt method, we find our data to be described by function parametrized by A = 0.0977 ± 0.0099 and A 44 = 0.0011 ± 0.0125. The χ 2 for the fit is 5.3, which, on ν = 4 degrees of freedom, implies that deviations from the fit as large as those exhibited by our data set would be expected 26% of the time. Our resulting fit, along with the scaled data, is plotted in Figure 10. These coefficients are not directly comparable with those of the theoretical correlation function, however. The finite angular acceptance of both detectors smears the correlation function, requiring an adjustment to the theory before the fit can be evaluated for consistency. In the case of cylindrically symmetric detectors, the correction factors can be computed directly via numerical integration if the efficiency of the detectors with respect to the incident angle is known. For these 3in 3in detectors separated from the source by 10 in, the whole-spectrum correction factors are Q 2 = 0.986 and Q 4 = 0.954, resulting in expected theoretical coefficients of A = 0.1020 and A 44 = 0.0091. These agree with our fit-

5 Angular Correlation for Cobalt 60 V. CONCLUSION Total Counts 7600 7800 8000 8200 8400 8600 8800 Data Monte Carlo 100 120 140 160 180 Angle [deg] FIG. 10: Measurements and uncertainties of the angular correlation function of cobalt-60 based on total counts. The least squares quadrupole-quadrupole fit is plotted as well. Results from Monte Carlo simulations provide a second means of assessing the effects of finite detector resolution. ted values given our propagated uncertainties. The precision of our measurements is not great, however, as A is only determined to within 36%. As an additional check of the correction factors, we conducted a 2-dimensional Monte Carlo simulation in the central plane of the detectors, which were again represented as 3 in disks with perfect efficiency at all wavelengths and incident angles. We fitted the same form of angular correlation function to the results, plotted in Figure 10, and obtained coefficients statistically consistent with the corrected theoretical coefficients with a χ 2 probability of 19%. Our results demonstrate that our theoretical understanding of the angular correlation of γ-rays produced in nuclear decay is accurate to within the uncertainties of our experimental apparatus. In particular, our measurements of sodium- are consistent with the δ-function distribution expected from pair annihilation, and our measurements of cobalt-60 agree with those expected from sequential 4-2-0 quadrupole-quadrupole transitions. While our experimental results were consistent with established theory, uncertainties in our measurements prevent us from extracting strict constraints on that theory. In particular, the long integration times required to minimize statistical uncertainties in the cobalt spectrum forced the data to be gathered on several different occasions, allowing temporal effects in the detection apparatus to accumulate significantly. Additionally, time constraints limited the extent to which we could take overlapping measurements to compensate for these effects. The limited output range of the linear fan-in also deteriorated the quality of our measurements by making analysis of the photopeak impractical. Future work could improve on our results by providing an environment in which a large number of partially overlapping measurements could be taken in close temporal proximity with a highly stable high voltage power supply. Extending integration times to 45 min or longer would reduce the moderately-sized statistical uncertainties, and scaling uncertainties would be removed entirely. These uncertainties currently dominate the final error and will continue to do so until the separation between data points approaches 1. The Monte Carlo representation of the cobalt source could also be extended to 3 dimensions to get a better handle on the smearing effects of the detectors finite angular resolution. Finally, smaller detectors would improve our ability to measure the angular correlation for Na. [1] D. R. Hamilton, Physical Review 58, 1 (1940). [2] E. L. Brady and M. Deutsch, Physical Review 78, 558 (1950).