ENSC 388: Engineering Thermodynamics and Heat Transfer

Similar documents
Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

UNIT 2 REFRIGERATION CYCLE

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

How To Calculate The Performance Of A Refrigerator And Heat Pump

The Second Law of Thermodynamics

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

Why and How we Use Capacity Control

How does solar air conditioning work?

Chapter 3.4: HVAC & Refrigeration System

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

Testing methods applicable to refrigeration components and systems

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

Thermodynamics - Example Problems Problems and Solutions

The Second Law of Thermodynamics

Waste Heat Recovery through Air Conditioning System

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Refrigeration Basics 101. By: Eric Nelson

Mohan Chandrasekharan #1

REFRIGERATION (& HEAT PUMPS)

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Condensers & Evaporator Chapter 5

Refrigeration & HVAC

We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.

Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics

Automobile Air Conditioning Primer

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

A/C refrigerant system, overview

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES

UNDERSTANDING REFRIGERANT TABLES

AIR CONDITION & REFRIGERATION INSTALLATION & REPAIR

AdSORPTION CHILLER NAK

ECOCIAT. Domestic hot water heat recovery unit

New Trends in the Field of Automobile Air Conditioning

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

How Ground/Water Source Heat Pumps Work

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Refrigerant Charge and Ambient Temperature Effects on the Refrigeration Cycle of a Small Capacity Food Freezer

High Pressure Ammonia Systems New Opportunities

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

How To Know If A Refrigeration System Is Efficient

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

Characteristics of Evaporators

Increasing the evaporation temperature with the help of an internal heat exchanger

TRAINING, EXAMINATION AND CERTIFICATION

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

How To Design A Refrigeration System

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM

Research on the Air Conditioning Water Heater System

P. A. Hilton Ltd REFRIGERATION & AIR CONDITIONING VAPOUR COMPRESSION HEAT PUMPS VENTILATION VOCATIONAL

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Technical data. Danfoss DHP-A

Low GWP Replacements for R404A in Commercial Refrigeration Applications

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Analytical Study of Vapour Compression Refrigeration System Using Diffuser and Subcooling

Stirling heat engine Internal combustion engine (Otto cycle) Diesel engine Steam engine (Rankine cycle) Kitchen Refrigerator

Lesson 36 Selection Of Air Conditioning Systems

Performance Improvement of an Air Conditioning System Using Matrix Heat Exchanger

Warm medium, T H T T H T L. s Cold medium, T L

Rusty Walker, Corporate Trainer Hill PHOENIX

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Optimal operation of simple refrigeration cycles Part I: Degrees of freedom and optimality of sub-cooling

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

The final numerical answer given is correct but the math shown does not give that answer.

LG Electronics AE Company, Commercial Air Conditioning

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

Energy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

AUTOMOTIVE AIR CONDITIONING SYSTEM.

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Chapter 10: Refrigeration Cycles

Experimental Analysis of an Automotive Air Conditioning System With Two-Phase Flow Measurements

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Efficiency of Hydrogen Liquefaction Plants

ON-VEHICLE INSPECTION

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

AIR CONDITIONING TECHNOLOGY

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Energy Procedia Energy 00 Procedia (2011) (2012) 56 65

Cooling system components, removing and installing

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges

Air Conditioning 101. STN Presentation AC101

Transcription:

ENSC 388: Engineering Thermodynamics and Heat Transfer Experiment 2: Vapor Compression Refrigeration Cycle Objective Determining the coefficient of performance of a vapour compression refrigeration cycle. Apparatus Figure 1 shows the experimental setup in details. Key components in the refrigeration system are a compressor, a condenser, an evaporator and an expansion valve. The compressor unit shown in Fig. 2 comprises an encapsulated, fully hermetic reciprocating compressor with an integrated drive motor. Such compressors are used in regular refrigerators. The condenser is a glass container with a cooling coil through which water flows (see Fig. 3a). The gaseous refrigerant is pumped into the container by the compressor, here it condenses and collects in the bottom of the container. Heat is drawn off via the water circulating in cooling coil in the container. The evaporator shown in Fig. 3b, similar to the condenser, includes a glass container and a copper coil through which water flows. In this case, the water is not used for cooling; conversely, it generates the cooling load. The refrigerant expands in the evaporator and changes from the liquid to vapor. The system has an expansion valve which is a float valve. Schematic of the expansion valve is shown in Fig. 4. Once the refrigerant collecting in the condenser reaches a certain level, the float (1) lifts the needle (2) from its seat, and opens the connection to the evaporator. The injection of the refrigerant into the evaporator is controlled by the expansion valve. When the system is started, the air in the system has to be released using the bleed valve. For this purpose the valve (item 20 in Fig. 1) is opened several times for a few seconds after the compressor is started, until the clearly detectable odour of escaping gas indicates that there is no more air in the system. 1

1 Table Support 12 Flow meter, Hot Water 2 Water Connections 13 Sight Glass 3 Temperature Measurement Point 14 Evaporator 4 Condenser 15 Pressure Display, Evaporator 5 Expansion Valve 16 Power meter, Compressor 6 Hand Valve 17 Switchable Temperature Display 7 ON-OFF Switch, Compressor 18 Flow meter, Refrigerant 8 Compressor 19 Pressure Display, Condenser 9 Filling Connection 20 Bleed Valve 10 Emergency Stop Button 21 Pressostat 11 Master Switch 22 Flow meter, Cooling Water Figure 1- Components of experimental apparatus Figure 2- Compressor unit 2

(a) Figure 3- a) Condenser and b) Evaporator of the system. (b) Figure 4- Schematics of the expansion valve. The system is equipped with 8 thermometers. The positions of the measuring points are marked with their numbers on the front panel of the system; these numbers correspond to the following points: = Cold water inlet, condenser = Cold water outlet, condenser = Hot water inlet, evaporator = Hot water outlet, evaporator = Mean temperature, evaporator = Refrigerant temperature, outlet of compressor = Mean temperature, condenser = Temperature after expansion valve The measured data collected during the operation of the system enables one to calculate the thermal characteristics of the system to be calculated. Filling and draining the system The system is to be filled until the glass container for the evaporator is half full (Fig. 1). The hand valves 1-3 are open during the filling process, hand valve 4 is closed. 3

Fit suitable hose to the filling connection (9) and insert into the container in which the refrigerant is supplied such that refrigerant can be drawn out. Start the compressor, a partial vacuum is formed in the evaporator such that the refrigerant is drawn out of the container Continue filling process until the evaporator is half full with the liquid phase of the refrigerant Close the hand valve 2, remove the hose Switch off the compressor The compressor is filled with oil on assembly in the factory; this filling is sufficient for its lifetime. Due to the fully hermetic construction, no more oil can be added during later operation. However, during its operation oil droplets enters the refrigerant circuit. When the system is switched off, the majority of the refrigerant and some oil gather in the evaporator. The oil is returned in the following way: Hand valves 2 and 3 must be closed Hand valves 1 and 4 must be open Switch on compressor, the liquid is drawn from the compressor through the capillary tube to the compressor and from there pumped to the condenser When the contents of the container have been drawn out, stop the process, for this purpose close valve 4 and open valve 3; in this way the system is again in normal operation For draining the system Switch off the compressor Fit the hose to the filling connection and place it in the container Open all hand valves except valve 4 Open bleed valve (item 20 in Fig. 1), the refrigerant slowly returns to the container Theory The basis of refrigeration systems is a thermodynamic cycle working between two different temperature sources. In this cycle a refrigerant (e.g. R134a) passes through various changes of state in a defined sequence and returns to its initial state. A refrigerator is a machine that removes heat from a low temperature region. Since energy cannot be destroyed, the heat taken in at a low temperature must be dissipated to the surroundings. The Second Law of Thermodynamics states that heat will not pass from a cold region to a warm one without spending energy or work. Therefore, a refrigerator requires energy input for its operation. It should be noted that heat pump and refrigeration cycles are the same, but in the 4

case of the heat pump the heat emitted is utilised where in the case of a refrigeration system the amount of absorbed heat is beneficial. One of the common refrigeration systems in use today is the Vapor Compression Cycle. Schematic of a vapour compression refrigeration cycle is shown in Fig. 5; this cycle has the following component: A compressor which compresses the vaporous working fluid and providing required mechanical energy,, to the system The condenser that absorbs heat (at constant pressure) from the working medium and transfer it to the high temperature source An expansion (throttling) valve that expands the liquid working medium during a constant enthalpy process An evaporator facilitates the evaporation of the working medium while it absorbs heat from the low temperature reservoir Figure 5- Schematics of a vapor compression refrigeration cycle. For thermal analysis of refrigeration cycle several diagrams such as or diagrams can be used. The pressure diagram of an ideal refrigeration cycle shown in Fig. 6, includes the following processes: 1-2: Isentropic compression to the final compression temperature with superheating of the working medium, adiabatic 2-2 : Isobaric cooling to the condensation temperature 2-3 : Isobaric condensation, releasing the condensation enthalpy 3-4 : Expansion in the wet vapour region, 4-1 :Isobaric evaporation, absorption of the evaporation enthalpy The key difference between the real cyclic process and the ideal cyclic process is that compression is not isentropic. Thus more work must be expended at the compressor to achieve the same final pressure. In 5

addition superheating of the refrigerant is necessary prior to compression to exclude, with certainty, the possibility of the entry of liquid droplets into the compressor. Otherwise the compressor would be damaged by the impact of liquid droplets. By means of liquid sub-cooling the vapour portion is reduced at the inlet to the evaporator. Hence, more evaporation heat can be absorbed. Figure 6- Pressure-enthalpy diagram of an ideal refrigeration cycle. Figure 7- diagram of a real refrigeration cycle. To calculate the refrigerating capacity, i.e., heat transfer from low temperature source,, the refrigerant mass flow rate should be known beforehand. The specific volume for the refrigerant is read from the diagram. Using the volumetric flow rate read on the volumetric flow meter,, the mass flow rate is calculated: (1) Consequently, the refrigeration capacity,, is calculated as: L h h (2) This value is identical to the heat which is transferred to the water cooled in the evaporator: 6

C T T (3) where is the water mass flow rate in the evaporator, C is the specific heat capacity of water, T and T are inlet and outlet temperatures of water in the evaporator, respectively. The compressor work W can be taken from the cyclic process plotted in the p diagram. It is given by the enthalpy difference between the working fluid states before and after the compressor (points 1 and 2 in Fig. 6): h h (4) Another important parameter in analysis of refrigerators is the coefficient of performance (COP). COP is the ratio of useful energy, i.e., heat transfer from low temperature source,, to the costing energy, i.e., the energy consumption of the compressor,. The COP can be greater than 1 because is the difference between the absorbed and the emitted heats. Therefore, the performance number must not be termed efficiency; efficiency is always less than 1. It should be noted that in real cycles, energy consumption of the cycle is different from and is equal to energy consumption of the driving motor,. Therefore, should be used in Eq. (5) instead of. A further parameter for a refrigeration system is the compressor compression ratio,. This provides an indication of the increase in pressure that takes part in the compressor. It is given by the ratio of the upper and lower isobars for the cyclic process (see Fig. 8): / (6) / The compression ratio may affects the COP of a refrigeration cycle. (5) Figure 8- Pressure ratio on a diagram of a refrigeration cycle. Procedure After the system is filled as described in previous sections, the subsequent procedure should be followed: 1. Close the hand valves 2 and 4 2. Open the hand valves 1 and 3 3. Start water flow through the system 7

4. Switch on compressor 5. Set the volumetric flow rate of the refrigerant, cooling and heating waters. Leave compressor to run for a while so that a steady state condition is reached in the system. Measure the temperatures T -T and also read the pressure in the condenser and the evaporator, fill out Table 1. On reading the manometer 1 bar must be added to the value read to obtain the actual pressure. 6. Change the flow rate of the refrigerant, wait until the cycle reaches its steady-state condition, and repeat step number 5. Using the diagram of R141b provided in Appendix A and the measured data during the experiment draw thermodynamic cycles for the two tests. Then, calculate the pressure ratio, the refrigeration capacity and the COP of the cycle for each pressure ratio. Also, plot the COP and the refrigeration capacity versus the pressure ratio. Table 1: Operating parameters vapor compression refrigeration cycle Test # 1 2 Test # Cooling Water Heating Water Refrigerant Condenser Evaporator Compressor Flow Rate Flow Rate Flow Rate Pressure Pressure Power 1 2 Discussion 1) What are the important characteristics of a refrigerant? 2) How pressure ratio variation affects the COP of refrigeration cycle? 3) When the state of the refrigeration locates in the saturation dome, how its state can be fixed? 8

Appendix A Figure 9- diagram of R141b 9