Agilent EPM-P Series Power Meters Used in Radar and Pulse Applications

Similar documents
81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Agilent U2000 Series USB Power Sensors

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Numerical Parameters Analysis of Boonton 4540 Peak Power Meter

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

802.11ac Power Measurement and Timing Analysis

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide

Agilent Test Solutions for Multiport and Balanced Devices

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Selecting RJ Bandwidth in EZJIT Plus Software

Agilent Measuring Noninsertable Devices

Agilent E6832A W-CDMA Calibration Application

Fast and Accurate Test of Mobile Phone Boards

Agilent E5100A Network Analyzer

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

RF Measurements Using a Modular Digitizer

RF Peak Power Analyzer

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

Agilent Technologies 3000 Series Oscilloscopes

Agilent 8753ET/8753ES Network Analyzers

PXI. GSM/EDGE Measurement Suite

How To Use A High Definition Oscilloscope

Power Amplifier Gain Compression Measurements

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Agilent U2000 Series USB Power Sensors

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Impedance 50 (75 connectors via adapters)

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

GaN or GaAs, TWT or Klystron - Testing High Power Amplifiers for RADAR Signals using Peak Power Meters

Improving Chromatic Dispersion and PMD Measurement Accuracy

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Interference Analysis

Agilent 8720 Family Microwave Vector Network Analyzers

Evaluating Oscilloscope Bandwidths for Your Application

R&S ZNC Vector Network Analyzer Specifications

Agilent Technologies Storage Area Network (SAN) Test System 1730 Series 1, 2 and 4Gb/s Fibre Channel Traffic Generators and Analyzers

Agilent 8904A Multifunction Synthesizer dc to 600 khz

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Dynamic Frequency Selection (DFS) and the 5GHz Unlicensed Band

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Conquering Noise for Accurate RF and Microwave Signal Measurements. Presented by: Ernie Jackson

R&S ZNBT8 Vector Network Analyzer Specifications

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Application Note Noise Frequently Asked Questions

Agilent GSM/EDGE Self-Guided Demonstration for the E4438C ESG Vector Signal Generator and PSA Series Spectrum Analyzers

AM/FM/ϕM Measurement Demodulator FS-K7

Agilent U2000 Series USB Power Sensors

The Next Generation in Automated Oscilloscope Test

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

A Guide to Calibrating Your Spectrum Analyzer

Agilent 4338B Milliohm Meter

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Field Calibration Software

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Agilent 8509C Lightwave Polarization Analyzer

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Vector Signal Analyzer FSQ-K70

Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide

NI USB-5681 RF Power Meter Specifications

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

Agilent Balanced Measurement Example: Differential Amplifiers

GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy

U1602A Handheld Oscilloscopes, 20 MHz

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Various Technics of Liquids and Solids Level Measurements. (Part 3)

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

TCB Workshop. Unlicensed National Information Infrastructure Devices (U-NII)/Dynamic Frequency Selection (DFS)

Agilent E5063A ENA Series Network Analyzer

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

Tackling the Challenges of Pulsed Signal Measurements

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

Extended Resolution TOA Measurement in an IFM Receiver

Optimizing IP3 and ACPR Measurements

Agilent 8590C/E Series Spectrum Analyzers and Accessories Configuration Guide

PCM Encoding and Decoding:

ETSI EN V1.2.1 ( )

Measurement Guide and Programming Examples

Lab 1: The Digital Oscilloscope

Agilent Automotive Power Window Regulator Testing. Application Note

Transcription:

Agilent EPM-P Series Power Meters Used in Radar and Pulse Applications Application Note 1438 Introduction The focus of this product note is the alternative ways that pulse and peak power measurements are made. The note looks at the measurement capability of the EPM-P series power meters and E9320 peak and average sensors for pulse measurements, along with the pulse analysis feature provided by the EPM-P Analyzer Software. Pulse Power Pulse power was traditionally determined by measuring the average power of the pulse and then dividing the measurement result by the pulse duty cycle value to obtain the pulse power reading, as shown: P p = P avg / Duty Cycle Power B (pulse repetition interval) Duty cycle = A B Measured average power A (pulse width) Time Figure 1: Pulse power measurement The measurement result is a mathematical representation of the pulse power rather than an actual measurement and assumes constant peak power. The pulse power averages out any aberrations in the pulse, such as overshoot or ringing. For this reason it is called pulse power and not peak power or peak pulse power as is done in many radar references. In order to ensure accurate pulse power readings, the input signal must be a repetitive rectangular pulse of constant, known duty cycle. Other pulse shapes (such as triangle or Gaussian) will cause erroneous results. This technique is also not applicable for digital modulation systems, where the duty cycle is not constant, and when the pulse amplitude or shape is variable.

There are some advantages with using duty cycle to calculate the pulse power. The duty cycle technique provides the lowest cost solution, with average power meters and sensors being less expensive than peak and average power meters and sensors. They also have the ability to measure over a wide power and frequency range. Agilent 8480 and E9300 average power sensors have a power range 70 dbm ( 60 dbm for E9300 sensors) to +44 dbm, and frequency range 9 khz (100 khz for 8480 series sensors) to 110 GHz (24 GHz for E9300 sensors). Let us take a look at how the power meter duty cycle technique works using an Agilent EPM series power meter. In this example, shown in Figure 2, we are supplying a pulsed signal with a pulse width of 10 µs and a pulse period, or pulse repetition interval (PRI) of 40 µs. The pulse signal is set with a power level of approximately 0 dbm. Average power Pulse power Pulse width 10 µs Average power = 10 log (PW/PRI) = 10*log(10/40) = 6.02 db Pulse repetition interval = 40 µs Figure 2: Measuring pulse power using duty cycle Using a power meter to measure the average power of the signal, the result of 6.79 dbm is shown in the average power display. Since the duty cycle is known to be 10 µs divided by 40 µs, which is 25%, this value can be entered into the power meter. This generates a pulse power reading of 0.77 dbm. To understand what the power meter is doing, we can look at the duty cycle calculation. The equation: Average Power = 10 log (Pulse Width / PRI) provides the difference between the average power and pulse power. This results in a calculated value where, for this example, the average power is 6.02 db lower than the pulse power. The power meter makes this correction to show the pulse power using the entered duty cycle. In a lot of cases, as shown in Figure 2, the pulse may not be purely rectangular since there is an associated rise and fall time, as well as overshoot and ringing on the signal. The combination of these effects, create an error in the calculated result. 2

Pulsed power measurements using the EPM-P series power meters The evolution of highly sophisticated radar, electronic warfare and navigation systems, which is often based on complex pulsed and spread spectrum technologies, has led to more sophisticated instrumentation for characterizing pulsed RF power. The EPM-P series power meters go a long way to provide this necessary power measurement sophistication. Used in conjunction with the E9320A sensors, they provide the measurement and pulse profile display of time-gated peak, average and peak-to-average ratio power measurements. The EPM-P power meters utilize a continuous sampling technique, and therefore can make measurements over a defined period rather than using a calculation. The EPM-P power meters have a 20 Msamples/s continuous sampling rate to allow accurate profiling of the signal being measured. In the design of a sampling power meter, the choice can be made between continuous sampling and random sampling, and for pulse measurements there are some clear advantages obtained by continuous sampling. For example, continuous sampling allows the signal to be captured if a single shot measurement is made. This is an advantage if the pulse you are trying to capture is not repetitive. Continuous sampling also allows for digital filtering architecture and bandwidth correction within the power meter. Digital filtering enhances the dynamic range of the meter/sensor combination, and bandwidth correction provides optimum accuracy for peak and statistical power measurements. In contrast, if random sampling is used, there is no guarantee that the peak signal will be captured. For repetitive signals the trace can be built up, however this happens over a number of traces and therefore takes longer to build the display. In Figure 3 the same signal as used for the duty cycle example in Figure 2 is being measured. Figure 3: Pulse power measurements using the EPM-P power meters From the EPM-P displays we can see the difference between the duty cycle method. The most obvious difference is the ability to see the pulse signal. The left side screen shot shows how the trace can be used to configure the measurements to be made. In this example two gates have been setup, the first gate over the pulse width of the signal, to measure the power within the pulse itself. The second gate, shown by markers 1 and 2 in the left side screen shot, measures the power across the full pulse repetition interval (PRI). The right side screen shot shows how the power meter s display can be configured with the trace being shown in the upper window and the lower window being set for a dual numeric display. In the dual numeric display we have chosen to display the average power within the two gates (A1 and A2 average power). We can see from the results that the average power over the full PRI is 6.05 db lower than the pulse itself. The measured value is therefore very close to the calculated 6.02 db difference for the duty cycle method, which was for the perfect pulse shape. 3

Keys to success in radar and pulse applications For radar and pulse applications the ability to make a time-gated power measurement is very important. The time-gated measurements are performed using the EPM-P power meters extensive triggering capabilities, and includes the ability to have up to four independent measurements on either a single pulse or on multiple pulses. An example of this is shown in Figure 4 where four independent start delays and gate lengths are set from the trigger event for a single pulse. Ext trigger Start 4 Start 3 Length 3 Length 4 Delay Start 1 Start 2 Length 1 Length 2 Figure 4: Versatile time-gating features of the EPM-P series power meters Each of these four measurements can be set up to measure peak, average or peak-to-average ratio. This gives a powerful measurement setup, for example, users have the ability to make a peak measurement on the overshoot (peak power in Length 2), measure the average power over the pulse burst (average power in length 1), and measure the pulse droop, this being obtained from the subtraction of the two powers in Lengths 3 and 4. Figure 5 shows the EPM-P power meter s capability to measure power on multiple pulses. Figure 5: Power measurements on multiple pulses 4

Level triggering can be used to trigger on pulse P1. The Start and Length can be used to measure the peak power of P1, P2 and between the markers shown in P3 (Length X). Stable and reliable triggering is also essential for viewing the pulse profile, this is achieved using the power meters Trigger Holdoff feature. This feature disables the trigger for a user-defined period. Understanding important pulse parameter specifications, as shown in Table 1, and how they relate to the signal under test, is also key to success in being able to measure radar and pulse signals. Key Parameter Dynamic range Frequency range Rise time Fall time Minimum pulse width Pulse repetition frequency Pulse repetition interval Pulse analysis EPM-P / E9323A/7A Specification 52 db peak (80 db average) E9323A: 50 MHz to 6 GHz; E9327A: 50 MHz to 18 GHz 200 ns 200 ns 300 ns 2 MHz 500 ns Use EPM-P analyzer software Table 1: Pulse-related specifications The dynamic range of 52 db, in Table 1, is for peak power measurements, which cover 32 dbm to +20 dbm, with the maximum dynamic range for average power measurements being 80 db, from 60 dbm to +20 dbm. Key specification definitions are: Rise time: The time difference between the 10% and 90% points of the pulse-top-amplitude. Fall time: Same as rise time measured on the last transition. Pulse width: The pulse duration measured at the 50% power level. Pulse repetition interval (PRI): The interval between the pulse start time of the first pulse waveform and the pulse start time of the immediately following pulse waveform in a periodic pulse train. Pulse repetition frequency: The reciprocal of the PRI. 5

EPM-P Analyzer Software Figure 6 shows the features of the EPM-P analyzer software. The analyzer software operates via the GPIB in a PC or laptop environment and provides statistical, power, frequency and time measurements. The analyzer software is in full control of the meter, therefore all the meter functions and pre-defined setups are not relevant as the software overrides the meter. The analyzer software is an Agilent VEE run-time program, and is supplied as standard with all EPM-P power meters, free of charge, on a CD-ROM or can be downloaded from www.agilent.com/find/powermeters. Marker measurements Setup for EPM-P Analysis screens Measurement setup Save, recall and save screens/data Figure 6: EPM-P analyzer software We have seen how we would set up the power meter for a pulse measurement and will now look at the capabilities of the EPM-P analyzer software for making measurements. Figure 6 shows the main areas that need to be considered. Setups for EPM-P: This software controls the power meter and is used to set up the Channel, Trigger and Gate Setups as shown through the front panel. The trace is required to be setup where the user sets the capture time. Analysis screens: After the power meter is configured, the trace is captured to allow for analysis of the captured trace data. There are various analysis screens covering statistical analysis such as Probability Density Function (PDF) and Complementary Cumulative Distribution Function (CCDF or 1-CDF) measurements and pulse analysis. Marker measurements: When the trace is captured, the marker measurements can be used to provide time and power information, and the trace can also be zoomed in on to look closely at areas of interest. Measurement setup: The display can show up to four real-time power measurements, which are configured in a similar manner to the power meter display, and allows timegated average, peak, peak-to-average ratio measurements, as well as combination measurements to be displayed. Save, recall and save screens/data: If the analyzer display is required for reports or import into other applications, the screen can be saved as a JPG or BMP file and the power and time data from the captured trace can also be saved in a CSV file. The analyzer software allows 10 states to be stored and recalled. This ensures easy set up of the analyzer software and allows repeatable measurements to be obtained. These states are saved in a separate file, and stored on the PC or a disc, ensuring users on different PCs are operating the same setups and therefore making the same measurements. 6

Selecting the Pulse Analysis screen will give the display as shown in Figure 7. A choice of rise time definition is presented with the most common definition being 10% to 90%. Power measurements include peak, average, overshoot and duty cycle. Time and frequency measurements include rise time, fall time, PRI, PRF and pulse width. Figure 7: Pulse analysis screen The pulse analysis computes the numerous power, time and frequency parameters shown in Figure 7. The notes at the bottom of the pulse analysis screen are informative about how the measurements are determined. The measurements made are on the captured trace data only, even if you have zoomed on the trace, all the captured data is used. The measurements are split into Power, and Time & Frequency information. The Power information includes the pulse top power, peak power, peak-to-average ratio, overshoot from the pulse top and the duty cycle. In the Time & Frequency measurements the rise and fall times, pulse width and off time are all calculated using the first measured transitions or pulse. If you are level triggering, it is good practice to add in a negative time delay in order to capture the complete first pulse rise time. If you want to analyze a secondary pulse, the trace captured would need to be made using a trigger delay to ensure the first pulse is not included in the data. Frequency and period measurements, such as PRI, are calculated on repetitions of the same transitions or pulse. If only one pulse is captured then no reading will be presented. It can be noted that the time resolution is accurate to +/- 50 ns; this is due to the 20 Msamples/s sampling rate of the EPM-P power meters, since 1/(20 Msamples/s) is 50 ns. The terms measured on the pulse analysis display are based on IEEE definitions 1. Pulsed power is difficult to measure, as the waveform envelopes under test require many different parameters to characterize the power flow. In 1990 with the introduction of the 8990 peak power analyzer series, Agilent chose to extend the older IEEE definitions of video pulse characteristics into the RF and microwave domain. The standard was originally a video pulse standard, the ANSI/IEEE standard 194-1977. For measurements of pulse parameters such as rise time or overshoot to be meaningful, the points on the waveform that are used in the measurement must be defined unambiguously. To achieve this, all the time parameters are measured between specific amplitude points on the pulse, for example the mesial point, and all the amplitude points are referenced to the two levels named pulse top and pulse base. 1. IEEE STD 194-1977, IEEE Standard Pulse Terms and Definitions, July 26, 1977. 7

Summary In summary, the EPM series average power meters can be used for pulse power measurements when using the duty cycle technique, however the ability of the EPM-P series power meters to make peak, average, peak-to-average ratio power measurements in the time domain make a better solution for measuring the power of pulsed signals. In the past, the now discontinued range of 899XA peak power analyzers were the instruments of choice for making pulse measurements. While the EPM-P power meters are not a direct replacement for the 899XA analyzers, they will provide a good fit in many radar and pulse applications, especially when combined with the EPM-P analyzer software. 8

Appendix A: Optimizing the EPM-P Power Meter Setup for Pulse Measurements The first hardkey we will look at is the Channel key, which provides an ideal summary of the setup within the power meter. For pulse measurements the main items are: Sensor Mode: The E9320 power sensors have two modes, Average Only and Normal. If peak measurements or time-gated measurements are being made then Normal mode should be selected. Average Only mode is suitable for measuring the average power of a signal up to 20 dbm, and for signals above 20 dbm this mode will give accurate results for CW signals only. Range: This is an important setting for pulse measurements, especially when narrow pulses are being measured. If auto range is selected the sensor may switch range from lower to upper during a rising edge and from upper to lower on a falling edge. The time delay for this with video bandwidth set to off is 4 µs and this may impair the measurement. Setting the range to upper or lower removes this delay. If the pulse signal being measured is above 15 dbm then upper range should be selected, and if the maximum power being input, including any overshoot, is less than 5 dbm the lower range should be selected. Frequency: Since the E9320A peak and average power sensors are fully corrected for calibration factors, and these corrections are stored in EEPROM, it is important to enter the frequency of the signal being measured to ensure optimum accuracy. Video Bandwidth: There are four settings for the video bandwidth High, Medium, Low and Off. High, Medium and Low refer to the modulating signal bandwidth and the filters used are designed to be very flat over the bandwidth. The Off setting provides approximately 3 db roll-off at the maximum bandwidth and is recommended for pulse measurements since it removes any ringing effects caused by the sharp filters. The High, Medium and Low settings allow for different bandwidths to be selected and the trade-off with bandwidth is dynamic range, the wider the video bandwidth, the smaller the dynamic range, as shown in Table 2. High (5 MHz) Medium (1.5 MHz) Low (300 khz) Off (5 MHz) 32 dbm to +20 dbm 34 dbm to +20 dbm 36 dbm to +20 dbm 32 dbm to +20 dbm Table 2: Video bandwidth versus peak power dynamic range for the E9323A/7A sensors Step Detect: If step detect is set to On, this will reduce the settling time after a significant step in the measured power. In this case the filter re-initializes if a step increase or decrease is detected. Trigger hardkey: To make use of the measurement gates for pulse measurements either single or continuous acquisition should be used. Under trigger settings the trigger can be either internal using the rising or falling edge, or an external trigger input or GPIB trigger can be used. The trigger mode can be chosen to be Auto level or Normal mode where a trigger level can be set. To ensure a stable reading is obtained, additional control features such as trigger holdoff, hysteresis and delay are provided. Meas Setup hardkey: This hardkey allows you to configure the display to see the measurements that are important to you. For pulse measurements it is often useful to see the trace and this can be combined with either a single or dual numeric display. The numeric display allows you to select the input type for the gate (average, peak or peak-to-average ratio). If a dual channel meter is used, mathematical combinations A-B, B-A, A/B and B/A can be set up.. Meas Display hardkey: This is where you can select the display type between the trace display, single or dual numeric or an analog display. Analog display is useful for monitoring maximum or minimum power adjustments. 9

Related Agilent Literature Agilent EPM Series Power Meters, Brochure, literature number 5965-6380E Agilent EPM Series Power Meter E-Series and 8480 Series Power Sensors, Data Sheet, literature number 5965-6382E Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors, Data Sheet, literature number 5965-1469E Agilent EPM-P Series Single and Dual-Channel Power Meters E9320 Family of Peak and Average Power Sensors, Product Overview, literature number 5980-1471E 10

11

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent T&M Software and Connectivity Agilent s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. By internet, phone, or fax, get assistance with all your test & measurement needs Phone or Fax United States: (tel) 800 452 4844 Canada: (tel) 877 894 4414 (fax) 905 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Online Assistance: www.agilent.com/find/assist Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2003 Printed in USA, January 28, 2003 5988-8522EN Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 Email: tm_asia@agilent.com