M C I C. MAERSK /SAFMARINE Container Inspection Criteria

Similar documents
TRITON CONTAINER INTERNATIONAL. Reefer Technical Bulletins. Version 4.0

Installation Instructions

Guidelines for Earthquake Bracing Residential Water Heaters

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

AMPSEAL* Automotive Plug Connector and Header Assembly

INSTALLATION INSTRUCTIONS

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Protecting Your Home from Wind Damage

SAFETY & OPERATING INSTRUCTIONS

Guidelines for Earthquake Bracing of Residential Water Heaters

Cedar Cottage Doghouse Plans

Basic Spring Motor Roller Shades

Technical data sheet PVC Bi-fold doors

Gear PEPSI CAN STOVE INSTRUCTIONS

19 DYNAmax Free Standing Server C A B I N E T s

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

19 DYNAmax Free Standing Server C A B I N E T s

2.9 WINDOW & DOOR BUCKS

39HQ Airovision Air Handling Units

MALONER. Installation & Loading Instructions - Please Read Before Beginning. Step 1: Installing Carriers to Cross Bars

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Protecting Your Home From Hurricane Wind Damage

RODENT PROOFING CHECKLIST

Window Installation Instructions

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

Mark Cramer Inspection Services, Inc.

FOR 20' X 8' X 8'6" ISO 1CC TYPE STEEL DRY CARGO CONTAINER WITH FULL CORTEN WITH

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

MODEL T200-F18 MODEL T125-F18 Finish Nailers

Rack installation instructions

Pole Lathe and Shave Horse Design

Modular Locomotive System Instruction Manual for HBK8 George Body Kit

INSTALLATION OF A BAY WINDOW

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

Fire Hydrant Troubleshooting

Your guide to home maintenance. Flat Roofs

March 14, Installation of Bay, Bow and Garden Windows

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Tundra Series Windows January 2016

GENUINE PARTS INSTALLATION INSTRUCTIONS

OWNER S MANUAL Table Tennis Table Patent Pending

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

Sash Replacement Guide

MGB Chrome Bumper Conversion


How to secure your property after a disaster

Oil and Gas Pipeline Design, Maintenance and Repair

Installation Instructions

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Ceiling Mounted Folding Attic Ladders Installation Instructions

SECTION PREFORMED METAL STANDING SEAM ROOFING

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

Post and Beam Construction

WINDOW REPAIR MANUAL & REFERENCE GUIDE

Rack Installation Instructions

Owner s Manual & Safety Instructions

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

Drive shaft, servicing

Packaged Terminal Air Conditioner Wall Sleeve Installation

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

A. All operable windows from Simonton include screens. With the exception of our Garden doors, our Patio door lines also include screens.

Table of Contents. Safety... 3 Specifications... 4 Assembly Maintenance Warranty Parts Lists... 30

Installation Instructions For Slider Casement Air Conditioners

DCF Optimized Rack System

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Maintenance & Inspection Guide

WINDOW CHANNEL, WEATHERSTRIP & WHISKER STRIP REPLACEMENT FOR 2-DOOR SEDANS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

MODEL J SERIES CONVERTER

SUPER SHED. Indoor shelter for your outdoor tools.


Check for deteriorated, shifting or missing tie-down pads. Replace if needed.

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Skirt 1 / 4. The Skirt. The skirt patterns were downloaded from Mark's site but they need expanding before they can be used.

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors

Chapter. Restoration of Damaged Structures

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

Air Conditioner Duct Construction & Repair

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

OSHA Remove impacted systems and components. Inspect systems prior to use.

How to Install Hardwood Flooring Over a Sub Floor

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

Residential Garage Door Terminology

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

Railway Freight Car Inspection and Safety Rules

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Structural Failures Cost Lives and Time

Installation, operation and maintenance manual TX 35A

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

Home Warranty Inspection Report

Transcription:

M C I C MAERSK /SAFMARINE Container Inspection Criteria (For use with all General Purpose- and O/T containers in-service) Supports the: U C I R C Unified Container Inspection & Repair Criteria (For use at all container interchanges) Issued by MCIC Version 6 (English) revised August 2010 Page 1 of 8

1. INTRODUCTION 1.1 General These criteria are designed for use at all container inspections The criteria should not vary between an in-service and on/off hire survey inspection and should be accepted on a universal basis by shipping lines, container leasing companies and container operators supporting these criteria for all general world-wide container interchanges Items not specifically detailed in the criteria are covered by this general introduction only if they require repair Any user of these criteria requiring a standard different from that detailed in the criteria should negotiate directly with the depot and/or owner/operator concerned The tolerances/permitted damages listed are not the minimum necessary to meet basic safety requirements but are selected to ensure the container is serviceable while minimising the need for repair and thereby preserving asset life The repair method selected should be the most economical and suit the particular repair location 1.2 Acceptable Damage This is defined as a damage that is not to be repaired and includes: all flange damage except damage to weld connections; deformation of structural members up to ISO +10mm on the side face of the corner casting and ISO +5mm on the end face of the corner casting; Previous repairs should not be reworked unless the structural integrity of the container is compromised or it is unsuitable for cargo. 1.3 Non-Acceptable Damage This is defined as damage that must be repaired because: The International Convention for Safe Containers, 1972, as amended (CSC) is violated and container safety is affected. There is a reduction in the internal height dimension by more than 70mm and/or the internal width dimension by more than 50 mm. Cracks or deformation in corner castings are present The container is unsuitable for cargo. Cracks in welds are present. Corrosion, not due to paint failure, causing loss of structural integrity is present. MCIC Version 6 (English) revised August 2010 Page 2 of 8

1.4 Wear & Tear This is defined as unavoidable change or deterioration of the condition of the container brought about by routine operational use and includes: General paint deterioration; Deterioration of door gaskets and fittings; Deterioration of door fixings arising from deterioration of doors; Flooring de-laminations resulting from routine cargo loading and unloading cycles. 1.5 Manufacturing Defects This is defined as differences to builder s specification with regard to material, workmanship and factory guarantees. Manufacturing defects or suspected manufacturing defects are to be reported to the owner. 2. GLOSSARY OF TERMS Bent/Bowed: Broken: Cracked: Cut: Dent: Gouge: Holed: Torn: sharp deflection in a component, which causes a permanent change in the original geometry of the component over some portion of its length or width. fractured or shattered into two or more separate pieces. having a fracture, which penetrates the entire thickness of material and causes it to split slightly? In addition, if a weld between two different metal components has any separation in it, even if the entire thickness of the weld material is not penetrated, that weld is considered cracked. separated throughout the entire thickness of material along a sharp edge. a localised depression in a panel or structural member made by pressure or an impact or blow that causes a sharp change in the shape of a component over a limited area of the component. A cavity in the surface of flooring with material scooped out. The width of the gouge is the smaller horizontal direction, regardless of the orientation of the gouge. perforated through the entire thickness. pulled apart by ripping or rending through the entire thickness of the material. MCIC Version 6 (English) revised August 2010 Page 3 of 8

3. MAIN STRUCTURAL COMPONENTS Component Damage Recommended repair methods, (by priority sequence) Rails, Headers & Sills Top Side Rail Deformation in excess of 30 mm Bottom Side Rail Web Flange Front & Rear Headers Front & Rear Sill Posts Corner Posts Front corner Posts Rear corner Posts Corner castings Deformation in excess of 50 mm Cracks or tears which extend into web radius Deformation in excess of 40 mm Deformation in excess of 50 mm Dents exceeding 25mm Dents exceeding 20mm Bend, bow or deformation, if exceeding outer faces of corner castings by +5 mm on end face or +10 mm on side face. Cracked, deformed, broken Deformation preventing correct twist-lock operation Weld or straighten and weld and weld, or insert or Straighten or insert or Straighten or insert or Replace Replace MCIC Version 6 (English) revised August 2010 Page 4 of 8

3. MAIN STRUCTURAL COMPONENTS (Continued) Component Damage Recommended repair methods, (by priority sequence) Floor/Under structure Forklift pocket & Goose Neck Tunnel Assembly Top plate separation from floor in excess of 10mm or floor screws ineffective Straighten or weld, or straighten and weld, or insert, or Cross Members Floor Floor Planks and panels Floor Fastenings Web holed, cut, torn, or cracked in excess of 50mm or extending into a weld connection Lower flange connection to bottom side rail, holed, cut, torn, cracked extending into web radius Web deformation below line of corner castings Top plate pushed up in excess of 50 mm, cut, torn or broken Strap broken, cracked, cut, torn, missing Web holed, torn, broken, cracked, cut or missing Web deformed in excess of 75 mm Web upper flange separated from floor by more than 10 mm Bowed up by more than 50 mm or below line of corner castings Gouge greater than 15 mm deep irrespective of length Gouge more than 6 mm deep and greater than 150 mm wide irrespective of length Delamination or other damage (affecting floor strength) Difference in height between adjacent planks/panels exceed 10 mm Holes other than nail holes Protruding Three or more adjacent broken/loose, missing fasteners and weld, or insert, or Straighten or weld, or straighten and weld, or insert, or Straighten or weld, or straighten and weld, or insert, or Weld, or straighten and weld, or Weld, or straighten, or straighten and weld, or insert, or Straighten, or Straighten and re-fix or Straighten or Section or Renew Section or Renew Replace if structural Refasten Plug (Maximum 25mm diameter) Refasten Refasten or Replace See guidelines at the end of the tables for allowable repairs on Plywood floors. MCIC Version 6 (English) revised August 2010 Page 5 of 8

4. OTHER COMPONENTS Doors Door Component Damage Recommended repair methods, (by priority sequence) component or weld, or deformation affecting security and operation of doors. and weld, or patch, or insert, or Missing/broken or loose parts (incl. Gasket) which affect door operation or water-tightness Replace or re-fix J Bars If interfering with door operation and weld, or insert Data Plates Loose or missing Plates Refasten or replace Side/Front/ Door-Panels/ Roof Panel including header plate Doors assembly incl. hardware and hinges component or weld, or deformation affecting security and operation of doors. Missing/ broken or loose parts incl. gasket which affect door operation or water tightness. Weld or straighten or vice versa or insert, or section or Renew or refit Locking bars Seized, frozen or stiff. Free-up / loosen Hinge pins Seized, frozen etc. Free-up / loosen Keepers/cams Cracked or deformed. Weld or Handle Torn or deformed. Renew J-bars If interfering with door operation. To be repaired and corrected Door gasket Holed, cut, torn, cracked Burned or showing light or water leaks. Minor damage, if light- and watertight, no action. If not, repair, Panels panel or weld. Dents into cubes which reduce internal width by more than 50mm from inner corrugation including multiple dents, or reduce internal height by more than 70 mm from the floor to the roof inner corrugation. Dents exceeding the outer face of corner castings +40mm. Weld, or straighten and weld, or patch or insert, or section Straighten, or straighten and weld, or patch, or insert Straighten, or straighten and weld, or patch, or insert, or section MCIC Version 6 (English) revised August 2010 Page 6 of 8

5. OTHER ITEMS Component Damage Recommended repair methods, (by priority sequence) Other Lashing rings Broken, cracked or missing or non functional Weld, or straighten or replace Surfaces Graffiti/Foreign Markings ISO Decals Rain Gutters Hazardous labels Glue (Sticky) Odour, infestation, debris, contamination that can be transferred Vents blocked, loose, damaged, and not weather tight, missing Any political, religious, sexual or possible offensive markings. Missing or illegible Damage affecting door operation or exceeding outer face of corner castings +10mm Remaining on panels Clean and/or paint Clean and/or remove Repair, or replace Remove or Clean Replace Straighten or remove Remove See Maersk Line Global Cleaning Guidelines for specific details on required container condition and associated cleaning activities. 6. REPAIRS TO PLYWOOD FLOORS. Delaminated plywood floors must be replaced, as below, when damage is observed to the 4 th layer of ply i.e. the top 3 layers are missing or loose and the 4 th layer is also damaged. Part replacement of plywood floors is allowed but only as below. A repair is only acceptable when both old and new sections of ply floor are supported by at least three under-structure support members. Acceptable Repairs: (i) (ii) (iii) Adjacent to the door at least a half-length plywood sheet must be used (minimum 1220 x 1220 mm). 2 cross members plus front sill 3 cross members plus forklift pocket support rail MCIC Version 6 (English) revised August 2010 Page 7 of 8

(iv) 3 cross members (where situations above do not apply) It is not necessary to carry out full-length replacement of sections. Half- length (1220 x 1220 mm), full width, replacement sections are allowable as long as the edges are properly sealed and the section is properly secured. Any floor repair must always involve the full width of the plywood sheet - partial width repairs are never acceptable Floor repairs that involve plywood sections that are unsecured on any edge are never acceptable. Metal plates are never acceptable as a permanent method of repair to a damaged or holed floor and must be replaced when observed. MCIC Version 6 (English) revised August 2010 Page 8 of 8