Carbon Monoxide (CO) Single-Point Gas Detection System

Similar documents
Carbon Monoxide (CO) Gas Detection and Control System

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Electronic Control Devices The European Product Catalogue 2007

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

WD-AMX Water Detection Controllers

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

PIEZOMETER AIRFLOW MEASURING RING

Advantium 2 Plus Alarm

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Fire & Security DETECTORS

Pressure Switch for gas and air

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

PRODUCT PROFILE FEATURES

INSTALLATION INSTRUCTIONS

TC-9102 Series Surface Mount Temperature Controllers

HMI display Installation Guide

Digital Keypad Use s Manual

Y7230A CO 2 Alarm System

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

FIREDEX Conventional Fire Panels

Fire Pump Controllers Remote Alarm Panels

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

FX07 Field Controller

T7560A,B,C Digital Wall Module

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

ACS-30-EU-EMDR-10-MOD

Series B14 Monitor System

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

Water Leak Detection System

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

User s Manual Before using the inverter, you need to read and save the safety instructions.

AIS750 Series Alarm Annunciator

Radiant Temperature Sensor TY7321

Model: DC-A2IO Advanced HVAC Controller

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

NC-12 Modbus Application

Product Specification instalert Rapid Messenger Variable Message Sign

Overview of Standards for CO Detection Products

Drayton Digistat +2RF/+3RF

Centro-Matic Automatic Lubrication Systems System Controls

UM-X Field display for continous level sensors

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

T0118 T2118 T3118. Instruction Manual

SEC 1500 Gas Detector Instruction Manual

SECTION LOW VOLTAGE LIGHTING CONTROLS

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

RAEGuard EC FGM-13XX

Controller Automation, Model II+

Contents. Document information

TrueAlarm Fire Alarm Systems

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

CQM1-SF200/CS1W-SF200

CO2 Alarm. Operation. Application

Electronic, Digital and Mechanical Vibration Switches

O C M III. Open Channel Flow Monitor

Repeaters and Mimics Data Sheet

User Manual. Humidity-Temperature Chart Recorder. Model RH520

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Panel Meters and Controllers Modular Panel Meter Type EDM 35

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

GSM Autodialer Professional GJD700 Speech & Text Autodialer

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

FX07 Field Controller

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

DUCT SMOKE DETECTOR D4120

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Buckeye Detection Systems Fixed Detection Systems Application Survey

Nokeval. User's Manual Models 301 / 302 / 305

PD 100A. Printing data system

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

T7079A,B Solid State Remote Temperature Controllers

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Multipoint Scanning Alarm System

System 350 A350E Electronic Cooling Control

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

Transcription:

Carbon Monoxide (CO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in carbon monoxide (CO) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity sensor. PolyGard SPC- APPLICATION To detect and control levels of carbon monoxide (CO) and other gases in a wide variety of commercial and industrial applications such as Carbon Monoxide level in parking structures, engine repair shops, equipment rooms and ventilation systems, etc. The controller can communicate with any compatible electronic analog control, DDC/PLC control or automation system via binary and/or analog output signal. FEATURES Continuous monitoring One () built-in CO electrochemical sensor Easy plug-in sensor One () remote analog input, -0 ma One () digital input Two () relay outputs: - Four stage control - Fail-safe assignable One () analog output, (0)-0 ma / (0)-0 VDC - Selectable for low, high, or averaging One () VDC switched output Liquid Crystal Display (LCD) LED status indicators Accepts toxic or combustible gas, refrigerant, temperature or humidity temperature remote sensor input Built-in horn Keypad user interface Simple menu-driven programming Modular technology Overload & short-circuit protected NEMA X enclosure Easy maintenance City of Los Angeles Approved NRTL Performance Tested & Certified Conforms to STD UL 0 SPECIFICATIONS Electric Power Supply VAC/VDC, -0%/+% 0/0 Hz, reverse polarity protected Power Consumption VA (0. A) w/ () remote sensor connected Sensor Performance Gas detected Carbon monoxide (CO) Sensor element Electrochemical, diffusion Range Span field adjustable from 0-00 to 0-00 ppm via calibration, 0-0 ppm factory set Stability & Resolution ±.0 ppm of reading Repeatability ±.0 % of reading Long term ouput drift 0.% signal loss/month Response time t90 0 sec. Sensor life expectancy - years, normal operating environment Sensor coverage,000 sq. ft., max 0,000 sq. ft. ( m, max 90 m ), under ideal conditions Installation Location Mounting height to ft. (.-.8 m) above floor Type of Control General Analog input Analog reading Stage level / setpoint Four-stage (S to S) control, assignable up to two () binary/ relay, horn/audible alarm, and VDC / 0 ma switched outputs, i.e. low-high stage for relay output, horn / audible alarm and switched VDC at any stage for remote alarming One () -0 ma, for additional remote sensor, load ma / 00, reverse polarity protected Current and mean (average) value Field adjustable over full range, four () stages (S to S) per analog input, assignable to current or mean (average) value - hysteresis/ switching differential Selectable for each sensor point Digital input One (); can be assigned to any relay (R, R). - application Remote audio/visual alarm reset or override function INTEC Controls, 00 Stowe Dr. Suite 0, Poway, CA 90 Page of Printed in USA

SPC- SPECIFICATION Type of Control (Cont...) Relay outputs (R, R) () SPDT (R), and () SPST-NC w/ status LEDs or SPST-NO (R), jumper selectable Contact rating 0 VAC/VDC, 0. A, max. - each stage level (S-S) Assignable to any relay - sensor fail-safe Assignable to any stage level Time delay switching Selectable for make and brake of each sensor point (SP to SP) 0-9,999 seconds Analog output One (), (0)-0 ma, load 00 ; (0)-0 VDC, load 0K ; jumper selectable; polarity protected, assignable to low, high or averaging of sensor inputs VDC switched output One () VDC, 0 ma max Audible alarm 8 db @ unit, enabled or disabled, selectable; assignable to stage level S, S, S or S Alarm acknowledgement Menu-driven and system reset function for latched relays User Interface Keypad type Refer to illustration keypad user interface Touch buttons Four () Status LED s Four (), for system on, stage status, and failure Digital display Liquid Crystal Display (LCD), two lines, characters per line, digit resolution - unit display Menu selectable, per sensor; ppm, %v/v, %LEL, F or % RH Environmental Permissible ambient - working temperature F to F (-0 C to 0 C) - storage temperature F to 8 F (- C to 0 C) - humidity to 9% RH, non-condensing - working pressure Atmospheric ± 0% Physical Enclosure (panel) - material Polycarbonate, UL 9-HB, fire-retardant - conformity UL 0 standards - color Light gray - protection NEMA X (IP) - installation Wall (surface) mounted, or single gang electrical box Dimensions (H x W x D). x. x.9 in. (0 x 0 x mm) Cable entry holes for / in. conduit for wall (surface) mounting and hole on back side of base plate for single gang electrical box mounting Wire connection Terminal blocks, screw type for lead wire Wire size Min. AWG (0. mm ) Max AWG (. mm ) Wire distance Max. loop resistance 0 (= wire distance plus controller input resistance) Weight 0. lbs (0. kg) Approvals / Listings - unit rating NRTL Performance Tested & Certified Conforms to STD ANSI/UL 0 City of Los Angeles CE VDI 0, C-No. 89 EMV-Compliance 00/08/EWG Low voltage directive //EWG - relays (R-R) UL Recognized, E CSA, C. No. 0, No. (File No. LR98) - enclosure UL Listed, E080 CSA Certified, E080 Warranty One year material and workmanship OPTIONS Enclosure Metal, wall-mount - material Galvanized steel w/zinc coating, corrosion resistant - color Light gray - protection NEMA, general purpose - installation Wall (surface) mounted, or single gang electrical box Dimensions (H x W x D).9 x.9 x.8 in. ( x x mm) Cable entry holes for / in. conduit for wall (surface) mounting and hole on back side of base plate for single gang electrical box mounting INTEC Controls, 00 Stowe Dr. Suite 0, Poway, CA 90 Page of Printed in USA

SPC- ORDERING INFORMATION SPC- - 00 US 0 Enclosures Wall NEMA, metal Wall NEMA X = Standard enclosure 00 0 99 Trip/Setpoints Factory set (for built-in sensor): Stage (S to S) S = Low alarm @ ppm CO (Relay R) S = High alarm @ 00 ppm CO (Relay R) S = Audible alarm @ 00 ppm CO (built-in Horn) S = Remote alarm @ 00 ppm CO ( VDC switched output disabled ) Special request Standard control system, ordering part number: SPC - - 00 US, configuration includes: Digital, programmable controller with menu-driven keypad user interface, LCD & LEDs, VAC/VDC, 0/0 Hz NEMA X enclosure Built-in: () CO sensor/transmitter () Horn, audible alarm Input: () -0 ma, for remote sensor Outputs: () Relays, 0 VAC/VDC 0. A; -SPDT (R) and -SPST-NO/NC (R), jumper selectable () Switched VDC, 0 ma () (0)-0 ma or (0)-0 VDC, selectable INTEC Controls, 00 Stowe Dr. Suite 0, Poway, CA 90 Page of Printed in USA

SPC- USER INTERFACE & CONTROLLER Keypad User Interface Alarm Orange LED Alarm Red LED Failure Yellow LED Power Green LED Alarm Alarm INTEC Controls SPC Main Page Main Menu Sub Menu INTEC Controls SPC Flashes when any stage level setpoint is exceeded; steady when any relay output is in manual override operation. Flashes when high alarm stage or multiple alarm stage level setpoints are exceeded; steady when any relay output is in manual override operation Flashes when system or sensor fails Steady when power is ON Scroll down in Main menu and Sub menus; decreases a value Navigates through menus on the same level; moves cursor when inputing data Exits programming and saves settings or return to previous level or menu Enter Sub menus or stores data; horn silence (if assigned) System Errors Stage Status Relay Status Sensor Readings Relay Setup SP Setup System Setup System Operation All Programming is made via the keypad user interface in combination with the display screen. Security is provided via two password levels. The lower level password allows to override or to reset system status functions. The upper level password allows all programming and override functions. Main Page Display After powered on, displays INTEC and part number and changes to sensor reading display unless a system error occurs; then the error is displayed. Main Menu Displays headings of System Errors, Stage Status Relay Status, Sensor Readings, Relay Setup, SP (Sensor Point) Setup, and System Setup. Sub Menu System Errors Displays errors, reset corrected errors, and historical error summary. Sub Menu Stage Status Displays status of each SP sensor point, stage level/ setpoint exceeded. Sub Menu Relay Status Displays status and manual control of each output relay. Sub Menu Sensor Readings The current and mean/average values are displayed for each SP sensor point with sensing type and engineering unit (ppm, %v/v, %LEL, F, %RH). Sub Menu Relay Setup Enter and /or change parameters of each relay. - Assign de-energized or energized normal operation - Select steady or flashing function - Select horn function - Select latching or non-latching mode - Select digital input usage, and assign to any output relay - Set delay ON/OFF time Sub Menu SP Setup Enter and/or change parameters of each sensor point. - Activate sensor point - Select sensor point type (gas, temperature, humidity) - Select measuring range - Select sensor signal - Select stage/setpoint to - Select hysteresis - Set delay ON/OFF time - Select current or mean/average value - Assign sensor point fault to stage level setpoint - Assign setpoint to to any output relay - Assign to analog output Sub Menu System Setup Enter and/or change system parameters. - Select service mode - Display software version - Set next maintenance date - Select service phone number - Select averaging function, time and overlay, of any SP - Set date, time and time format - Change customer password - Set failure relay - Select power ON time - Select analog output function INTEC Controls, 00 Stowe Dr. Suite 0, Poway, CA 90 Page of Printed in USA

SPC- WIRING CONFIGURATION VAC/VDC Input Power Supply, and Analog Output AO0 X (0) -0 ma, or (0) -0 VDC*** VAC/VDC** -0%/%, 0/0 Hz ***Jumper output signal AO0 range selectors: 0-0% V-A X Over both pins Pins not covered Over both pins Pins not covered = VDC = ma = -0 ma / -0 VDC = 0-0 ma / 0-0 VDC Optional -0 Remote AT-...V Series Sensor/Transmitter Input SP0, -0 ma, -wire sensor/transmitter -0 ma Common VAC or VDC** -0 ma, -wire loop-powered sensor/transmitter X -0 ma VDC** Twisted, shielded wire is recommended for - or - wire configurations. Binary-Relay Outputs R0 and R0, VDC switched Output S, and Digital Input Digital input VDC, 0 ma Relays are normally de-energized, 0 VAC/VDC 0. A S = Built-in horn S = Switched output **Jumper SPST relay (R) NC/NO selector: NC NO NO NC Common NC/NO** Common X 8 9 0 Covers top two pins = SPST-NC Covers buttom two pins = SPST-NO **/*** Be Alert: Only the same type of power, VAC or VDC, as supplied to the unit, is available for the remote transmitter. I. E. When VDC transmitter power is required, the unit must be powered with VDC. -wire loop powered transmitter transmitter can use the internal power. -wire transmitters that allow power common to DC common can use the same power supply to power the SPC and the transmitter. -wire transmitters that require separate power common from DC common must use a separate power source. S S R R INTEC Controls, 00 Stowe Dr. Suite 0, Poway, CA 90 Page of Printed in USA