ABLOY EL490, EL590 AND PE590 SCANDINAVIAN RANGE MOTOR LOCKS

Similar documents

ABLOY EL420, EL520 Europrofile motor locks

ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand


ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions

ABLOY DC 240 DOOR CLOSER Heavy duty door closer


EXIT HARDWARE. Uniclass L CI/SfB (31.59) Xt7 VERSION: AUGUST-11. An ASSA ABLOY Group brand

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

Narrow stile lock 1314

ABLOY VEGA CABINET LOCKS

Panic & emergency exit devices

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

KEY CYLINDER PLATFORMS

Lock Function Chart Page 1 of 7

Modular mortice locks

WE ARE UNION. replace with new shot. Mortice Lock Range. ASSA ABLOY, the global leader in door opening solutions

Key in Knob & Key in Lever

Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors

What locks do I have Timber Doors

Mechanical Entry Locksets

INSTALLATION MANUAL XM3 Reader

Mechanical Digital DX Locks

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

Digital Keypad Use s Manual

UBC Technical Guidelines Section Edition Secure Access: General Standards Page 1 of 7

PHA 2000 PHB 3000 EXIT PAD

Euro Profile Mortice Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

CISA Safe Home. Locks for shutters and security grates

An overview of mechanical lock and security related standards and why they re important to the Insurance Industry

D.A.C.S. Door Access Control System

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Standard Door Specification

Adaptability to Enhanced Security

Adaptability to Enhanced Security

PAC1 Door Access Controller

Fire suppression system for engine compartments USER MANUAL

Mortice Lock. ASSA ABLOY, the global leader in door opening solutions

e-ask electronic Access Security Keyless-entry

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

TS93 EMR T/PT/TDE. Surface applied door closer

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Patented technology ASSA P600. Reliable master key system. ASSA ABLOY, the global leader in door opening solutions

1000 Series Knob Pushbutton Locks

Relevant British, European and International standards

Shunt lock function 3066

CREATING LOCKING SOLUTIONS...

AD425S Automatic door operator

ASSA ABLOY Factory Training Adams Rite HES Securitron Course Offerings

ScanFlex lever handles

SECURITY LATCH TM SIMPLE, SAFE & SECURE

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

HyperAccess Access Control System

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

USER MANUAL V5.0 ST100

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

TrueAlarm Fire Alarm Systems

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Basic Technical Fundamentals of Builders Hardware Mortise, Bored and Auxiliary Locks

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

9300BC SERIES Light Commercial Door Closer

Simplex. Mechanical Pushbutton Locks Keyless Convenience

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Basic Technical Fundamentals of Builders Hardware

bts 80 f/emb/flb/bsr Floor spring system

Shunt lock function 3066 Operator Instructions

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Electromagnetic Locking

FIREDEX Conventional Fire Panels

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Controlers. Controler

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Combi B Alarm box. Mounting instructions

Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Stove Guard Kit User Manual

Commercial or Business Security Survey

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

Mechanical Pushbutton Locks Keyless Convenience

Series 300 / 200. Mortice locks for timber doors

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Transcription:

ABLOY EL490, EL590 AND PE590 SCANDINAVIAN RANGE MOTOR LOCKS Flexible multifunctional locking

application The electromechanical ABLOY locks offer complete high security solution whenever you need pedestrian traffic control in addition to mechanical locking safety, for example in fire doors and exit doors. By using the latest technology, the ABLOY motor locks are developed to further increase both security and safety of the door environment. More possibilities - less product versions ABLOY motor locks EL490 for narrow profile doors and EL590/PE590 for wooden and metal doors are developed to aid product selection for demanding and functionally challenging door environment. The motor locks are especially suitable for one- and two-way access controlled fire doors and emergency exit doors. One-way access controlled doors Typical applications are the exterior and fire doors of business premises hospitals Doors with both access control and fixed time control Typical applications are the exterior of educational premises public buildings sport halls apartment buildings Two-way access controlled doors exterior and fire doors of business premises access controlled doors, which are used also as emergency exits hospital and residental building doors, when special control is needed (e.g. dementia wards) Entrance doors for customers with both access control and fixed time control exterior doors of business premises, where extra security is required to prevent vandalism (e.g. bank entrance doors)

One-way access controlled doors function The lock is electrically controlled by access control system. Mechanical opening by cylinder and by inside handle / push pad (EN179/EL490, EL590) or panic bar is always possible. Please note the following lock case settings: Bolt throw 14 mm in fire rated doors (EL590) EL490/EL590 EL490/EL590 EL490/PE590 Doors with both access control and fixed time control The lock is electrically controlled by fixed time control or access control system. When time controlled, the door can be opened by pulls and when access controlled, the door can be opened by a reader outside and with inside handle. Mechanical opening by cylinder and inside handle is always possible. EL490/EL590 Two-way access controlled doors The lock is electrically controlled by access control system, i.e. the lock can be opened by readers from both sides of the doors. In case of emergency the door can be opened with the inside handle, which is activated by e.g. central fire alarm. In case of power failure, mechanical opening with the inside handle is always possible. EL490/EL590 Please note the following lock case settings: The bolt throw 14 mm in fire rated doors (EL590) In emergency exit doors the handle operation must be changed to electrically controlled Accessory Exit button Entrance doors for customers with both access control and fixed time control The lock is electrically controlled by access control system. Mechanical opening by inside cylinder is always possible. In case of emergency the inside handle is controlled by e.g. central fire alarm system or with exit button. In case of power failure, mechanical opening with the inside handle is always possible. EL490/EL590 Please note the following lock case settings: In emergency exit doors the handle function must be changed to electrically controlled Accessory Exit button

24.5 technical information features ABLOY EL490, EL590 and PE590 motor locks offer several functional options in just one lock case. Because all the options are covered by a small number of versions, the same lock can be used in several differently functioning door environments. The following mechanical and electromechanical functions can be set at the installation phase. handing of the bolt handing of the trigger bolt (EL590, PE590) bolt throw: 14 or 20 mm (EL590) handle function: mechanical or electrically controlled (EL490, EL590) opening delay 1-20 sec. monitoring The lock includes the following monitoring outputs: bolt deadlocked handle down cylinder monitoring (available as an accessory) The monitoring output for door automatics: bolt in The monitoring outputs are not available during power failure. technical details Operating voltage: Current: Max Normal (seal force 50N) Idle Relays: Operating temperature: Bolt throw: Backset: Forend: Spindle: Door clearance: Finish: Cylinder monitoring: delivery Standard delivery includes: Lock case, handing 2,4 Fixing screws etc. Lock case manual 12 (10%) - 24 (+15%) VDC STAB 1700 ma (12 VDC) 700 ma (24 VDC) 600 ma (12 VDC) 250 ma (24 VDC) 50 ma (12 VDC) 25 ma (24 VDC) Max. 30V, 100 ma -25...+70 o C 14 mm/20 mm (EL590) 14 mm (EL490, PE590) 50 mm (EL590, PE590) 29 mm/35 mm (EL490) 22 mm (EL590, PE590) 25 mm (EL490) 8 mm 2-5,5 mm (the distance between forend and striker plate) Chrome plated forend Switch 950885 (EL590, PE590) Switch 950886 (EL490) Versions of lock cases with cylinder monitoring: EL490 29mm 110011 / EL490 35mm 110021 / EL590 110011 dimensions 278 253 ABLOY EL490 104 18 4 25 10.5 8 ABLOY EL590, PE590 3 29/35 47/53 21.5 115 211.5 cylinders and accessories (please order separately) EL590 PE590 EL490 CYLINDERS ABLOY PROTEC2 (T) ABLOY PROTEC (N) EXIT DEVICES ABLOY NOVEL (U) CY021 (inside) CY037 (outside) Double CY002 Handle (EN 179): Thumbturn Double Thumbturn CY001 CY037 (outside) CY021 (inside) *) For further information, please contact Abloy Architectual hardware e.g. ABLOY PRESTO 3-20/030*) Push pad (EN 179): ABLOY PPE002 Panic Bar (EN1125): ABLOY PBE002 CY064 (inside) CY063 (outside) Handle (EN 179): e.g. ABLOY PRESTO 3-20/0630*) CY065 Push pad (EN 179): CY066 ABLOY PPE003 CY063 Panic Bar (EN1125): ABLOY PBE003 STRIKE PLATES LP12 LP22 LP32 EA307 EA308 4613 4614 CABLES EA217 (6 m) EA227 (10 m) EA228 (0,5 m) 18x0,14 mm² LEAD COVERS EA280 EA281

more functions less accessories ABLOY EL490, EL590 and PE590 motor locks offer most comprehensive features which reduce the need of accessories in both access controlled emergency exits and fire doors. For example there is no longer need for emergency power supply, exit buttons, thumbturns or emergency exit domes. In addition to that more status information is available. One-way access controlled doors no need for emergency power supply in fire doors no need for separate push buttons or emergency exit domes the door can always be opened with the inside handle, push pad or panic bar Doors with both access control and fixed time control no need for separate push buttons or emergency exit domes the door can always be opened with the inside handle Two-way access controlled doors no need for emergency exit domes no need for magnetic locks in especially demanding applications in emergency situations the door can be opened with the inside handle which is activated by e.g. central fire alarm and always in case of power failure. Entrance doors for customers with both access control and fixed time control no need for emergency exit domes in emergency situations the door can be opened with the inside handle ABLOY Motor locks have been tested according to the following standards: EN 1634-1 (for fire resistance) EN 14846 (for electromechanically operated locks) EN 179 (for emergency exit doors) EN 1125 (for panic exit doors) The durability of ABLOY EL490, EL590 and PE590 motor locks has been tested with 200.000 opening cycles.

ABLOY EL490, EL590 AND PE590 SCANDINAVIAN RANGE MOTOR LOCKS Abloy develops continuously the products and solutions offered. Therefore, the information contained in the marketing materials is subject to change without notice. ABLOY secures people, property, and business operations on land, at sea, and in the air in all circumstances. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. MANUFACTURER: Abloy Oy Wahlforssinkatu 20 P.O. Box 108 FI-80101 Joensuu Finland Tel. +358 20 599 2501 WWW.ABLOY.COM An ASSA ABLOY Group brand PEFC/02-31-151 8802257. 08/2014 1500 kpl PunaMusta Oy, Joensuu