CO 2. Technology. Technology Benefits at a Glance: What Exactly is a Sub-Critical System? More than 50 Second Nature CO 2

Similar documents
Low GWP Replacements for R404A in Commercial Refrigeration Applications

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS

Heat Recovery In Retail Refrigeration

How To Understand Evaporator

Urban Fare Express Installs First Hillphoenix Advansor Transcritical CO2 Booster System in North America

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30,

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

Natural Alternatives in the Refrigeration & Air Conditioning Sectors

Advanced Heat Reclaim Systems. Harrison Horning, PE, CEM Delhaize America - Hannaford

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Commercial CO 2 Refrigeration Systems

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. ACHP 104 Refrigeration & Air Conditioning Service II

How does solar air conditioning work?

Freezer Floor Heaving and Solution

Part A: Fluid properties

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

Rusty Walker, Corporate Trainer Hill PHOENIX

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Why and How we Use Capacity Control

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigeration Basics 101. By: Eric Nelson

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Guidelines of how to instrument, measure and evaluate refrigeration systems in supermarkets PAU GIMÉNEZ GAVARRELL

8. Refrigeration. 4. Liquid. Refrigerant. 4. Liquid Refrigerant. Figure 8.1 Refrigeration system layout (single stage)

Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment

As supermarkets look to lessen

Thermal Coupling Of Cooling and Heating Systems

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Open Cycle Refrigeration System

High Pressure Ammonia Systems New Opportunities

THE REPLACEMENT OF R-22

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

Direct Fresh Air Free Cooling of Data Centres

How To Design A Refrigeration System

TRAINING, EXAMINATION AND CERTIFICATION

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

State of the Art Energy Efficient Data Centre Air Conditioning

DIABLO VALLEY COLLEGE CATALOG

A/C refrigerant system, overview

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

DEFROSTING. Service Engineers Section Technical Bulletin No 3

High School Graduation years 2013, 2014, Unit/Standard Number

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Chapter 3.4: HVAC & Refrigeration System

Low-GWP Alternatives in Commercial Refrigeration: Propane, CO and 2 HFO Case Studies

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

DESIGN STANDARDS SECTION

MAC-120HE-01 Air-Cooled Chiller

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

The Different Types of Air Conditioning Equipment for IT Environments

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

AIRAH Presentation April 30 th 2014

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications. Samuel F Yana Motta

Increasing the evaporation temperature with the help of an internal heat exchanger

HEATING, VENTILATION & AIR CONDITIONING

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

Test Code: 8297 / Version 1

UNDERSTANDING REFRIGERANT TABLES

Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods By: Daniel Kennedy

Guide to Good Commercial Refrigeration Practice. Part 2. System Design and Component Selection

Defining Quality. Building Comfort. Heating and Cooling Coils

REFRIGERATED COMPRESSED AIR DRYERS

2015 CARNOT REFRIGERATION CO 2 PROJECTS IN DATA CENTRES, COMMERCIAL AND INDUSTRIAL REFRIGERATION CASE STUDIES

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Supermarket Refrigeration Trends in the Asia Pacific Region. Brian Rees Group Technical Manager McAlpine Hussmann Ltd.

Two-Phase Evaporative Precision Cooling Systems

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

Characteristics of Evaporators

Commercial Hot Water. Make a difference...

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

New Trends in the Field of Automobile Air Conditioning

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Air Conditioning 101. STN Presentation AC101

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015

Transcription:

Technology Second Nature systems that utilize technology offer several distinct advantages over traditional DX refrigeration systems. These sub-critical systems deliver superior refrigeration performance with enhanced sustainability, reduced refrigerant charge requirements and greatly reduced refrigerant leak rates. Simply, they are the most energy-efficient and environmentally-friendly refrigeration systems available in the industry today. What Exactly is a Sub-Critical System? Second Nature systems operate at pressures similar to standard air conditioning units that use R-410A refrigerant. While those pressures are higher than the ones found in conventional DX systems with HFCs, they are still significantly lower than the critical pressure of 1050 psig. As a comparison, Technology Benefits at a Glance: Significant HFC charge reduction HFC leaks reduced dramatically Lower return gas temperatures improve compressor energy performance Copper pipe usage reduced (smaller diameters and shorter runs) Excellent material compatibility Eliminates future refrigerant retrofits that interrupt sales floor activity refrigerant is abundantly available and inexpensive Much smaller carbon footprint is naturally occurring and delivers a GWP (Global Warming Potential) of almost 0 Overall energy consumption is less Sustainable technology helps achieve GreenChill certification transcritical systems operate above critical pressure, often approaching 1500 psig. More than 50 Second Nature systems have been installed since 2006. From as far south as Columbia, South America to as far north as Calgary, Canada, in the moderate climates of California to the heat and humidity of Texas, Hill PHOENIX systems perform. SNLT2 Projects SNLTX2 & SNMT2LX Projects

SNLT2 Low Temperature Secondary Coolant Technology SNLT2 Systems utilize as the heat CONDENSER AND HEAT RECLAIM LOADS transfer fluid in a secondary coolant system. Since has excellent thermodynamic and transport properties, the secondary LOW PRIMARY HFC coolant removes heat from low temperature display cases and walk-in freezers via copper piping that is significantly smaller than what is typically required in traditional, direct expansion (DX) systems. LT LOADS HFC Discharge Gas HFC Suction Gas Vapor Liquid LIQUID-VAPOR SEPARATOR PUMP VALVES LOW SECONDARY SNMT2 Medium Temperature Secondary Coolant Technology SNMT2 systems use as the heat transfer fluid in a secondary coolant system. SNMT2 CONDENSER AND HEAT RECLAIM LOADS systems operate exactly like SNLT2 systems but at a temperature suitable for medium temperature refrigeration. SNMT2 systems MEDIUM PRIMARY HFC are a higher efficiency alternative to secondary systems using glycol. CONDENSER- EVAPORATOR MEDIUM TEMP EVAPORATORS HFC Discharge Gas HFC Suction Gas Vapor Liquid LIQUID-VAPOR SEPARATOR VALVES MEDIUM SECONDARY LIQUID PUMP Secondary Technologies

SNLTX2 Direct Expansion Cascade Technology SNLTX2 systems utilize as a low temperature, direct expansion (DX) refrigerant in a cascade system. The removes heat CONDENSER MEDIUM PRIMARY HFC from display cases and walk-in freezers via CONDENSER- EVAPORATOR copper piping that is also significantly smaller than what is typically required in traditional HFC-based, direct expansion systems and even smaller than in our SNLT2 secondary systems. The upper cascade (primary sys- LOW CASCADE tem) is a medium temperature refrigeration system. HFC Discharge Gas HFC Suction Gas LOW TEMP LOADS Discharge Gas Liquid Vapor Comparison: SNLT2 vs. SNLTX2 SNLT2 Secondary System Pumped-liquid system with simple solenoid valve for evaporator control (same for SNMT2) Fully-flooded coils make most use of coil surface No superheat section in coils for slightly more efficient evaporator performance than SNLTX2 system Able to take full advantage of deep subcooling (30 F liquid) on HFC primary system. Using 30 F liquid can result in energy performance equal to SNLTX2 systems Over 30 sites in operation since 2006 Requires electric defrost Little or no circuit balancing required Installation of piping critical SNLTX2 DX Cascade System Direct expansion system with components and controls more familiar to contractors/operators Hill PHOENIX SmartValve system for most economical application of electronic expansion valves Direct expansion operation less sensitive to coil circuiting - easier to apply third party coils (cases) discharge gas desuperheater can be used to improve energy performance Smaller line sizes than SNLT2 system and reduced insulation requirements for installed cost savings Smaller footprint and lower weight than SNLT2 system Lower charge than SNLT2 system HFC primary system (upper cascade) can be used to cool other medium temperature loads for overall reduced refrigerant charge More than 15 sites in operation since 2008 Requires electric defrost Cascade Technologies

AIR-COOLED CONDENSER SNLTX2 & SNMT Cascade Combined with Glycol Secondary MT RACK HFC COMPRESSORS MEDIUM PRIMARY HFC Since the SNLTX2 technology operates with a medium temperature upper cascade, it can be combined with the primary side of our SNMT medium temperature secondary system using glycol. By consolidating the two systems, the required refrigerant charge is further reduced. With more than 600 installations throughout North America, our performance-proven SNMT systems can now be applied with our latest low temperature technologies. CONDENSER- EVAPORATOR LT RACK COMPRESSORS LOW LOADS GLYCOL CHILLER GLYCOL PUMP STATION VALVES LOW CASCADE MEDIUM LOADS MEDIUM SECONDARY GLYCOL HFC Discharge HFC Suction Discharge Liquid Vapor Glycol Return Glycol Supply SNMT2LX Combined System Technology Sharing a common, medium temperature primary system, the SNMT2LX system combines a medium temperature secondary system (SNMT2) with a low temperature cascade system (SNLTX2) to further reduce refrigerant charge and consolidate duplicate components. Evaporator control uses Hill PHOENIX SmartValve technology with electronic expansion valves () on low temperature and simple solenoid valve control on medium temperature. Hill PHOENIX completes the picture by providing a full range of standard and specialty display cases with evaporators specifically designed to complement each of the Second Nature products discussed above. CONDENSER-EVAPORATORS MEDIUM LOADS PUMP VALVE AIR-COOLED CONDENSER AND HEAT RECLAIM LOADS MT UPPER CASCADE COMPRESSORS LIQUID-VAPOR SEPERATOR LOW LOADS MEDIUM PRIMARY HFC LOWER CASCADE COMPRESSORS PUMP SKID LOW CASCADE HFC Discharge HFC Suction Discharge Liquid Vapor Combined Systems

709 Sigman Road, Conyers, GA 30013 770-285-3100 phone 770-285-3071 fax website: www.hillphoenix.com e-mail: marketing-refrigerationsystems@hillphoenix.com 2011 Hill PHOENIX, Inc. RS-SN11v0911