Push Button Interface, 4-fold, FM TS/U 4.2, GH Q R0002

Similar documents
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Busch-Watchdog Presence EIB Type:

Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S , GH Q R0111. ABB i-bus EIB / KNX

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Application Unit, MDRC AB/S 1.1, GH Q R0111

Inwall 4 Input / 4 Output Module

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Push button 3gang standard flush-mounted xx

KNX Gateway RGK E-01

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

How To Use A Power Supply On A Powerline 2.2 (Ai)

ABB i-bus EIB / KNX Room Controller

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

Light scene push button 8gang comfort flush-mounted xx

ABB i-bus EIB / KNX Weather Station WS/S 4.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Inwall Room Temperature Unit

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Product and functional description

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus KNX DALI-Gateway DG/S 8.1

ABB i-bus KNX SA/S Switch Actuators Product Manual

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Transmitter Actuator 230V wave UP 560. Operation

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Time functions. Functions of the relay. instabus EIB Application program description. September A1 Binary 510D01

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Operating instructions IV / 2007

Operating instructions II / 2004

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

ABB i-bus KNX IP Router IPR/S 2.1

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

ABB i-bus KNX i-bus Tool Product Information

Movement/monitoring 1307/1.0 (6325xx)

Technical Manual MDT Rain sensor

ABB i-bus EIB Application unit AB/S 1.1 with application program Times Groups/1

Wind Sensor W-RS485 with RS485 Interface

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Copyrights 2010 Victron Energy B.V. All Rights Reserved

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Unica for KNX system 226

gesis KNX RM Manual Installation System for European Installation Bus Product and Object Description Doc. no. BA Wieland Electric GmbH

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Electronic Control Devices The European Product Catalogue 2007

IntesisBox KNX Mitsubishi Heavy Industries AC

DALI RC BASIC SO. Control unit Operating instructions

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

IntesisBox KNX - LON

ABB i-bus KNX Switch Actuators SA/S Product Information

Disturbance Recoder SPCR 8C27. Product Guide

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus RTU master

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

ABB i-bus KNX Switch Actuators SA/S Product Information

KNX L. Brightness Sensor. Installation and Adjustment. Item number 70119

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

Drayton Digistat +2RF/+3RF

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

OZW30. Central Unit SYNERGYR

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

ABB i-bus KNX Application Manual Lighting

Preset Counter signo 721

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

HERZ-Thermal Actuators

Electronic Control Devices The European Product Catalogue 2007

Air damper actuators

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Safety technique. Emergency stop module BO 5988 safemaster

is then retained absolutely without interruption.

IntesisBox KNX LG Air Conditioning

Transcription:

Push Button Interface, -fold, FM, GH Q605 0025 R0002 The push button interface is used for example for the connection of conventional switches or push buttons. It can be fitted together with a switch in a combined wall and joint box (60 mm, 60 mm deep). The push button interface can send e.g. switching, dimming, shutter control or 1 byte value telegrams to EIB actuators. Inputs A and B or C and D are combined for dimming and shutter control. SK 0025 B 95 The floating contacts are connected via four core pairs (28 cm long). The prefabricated cables can be extended up to 5 m using twisted cables. The contact scanning voltage is supplied by the push button interface. The bus connection is established via a bus connecting terminal. Technical Data Power supply EIB 2 V DC, via the bus line Inputs, for floating contacts Scanning voltage 20 V impulses Scanning current 1 ma with closed contact Cable length 280 mm, can be extended up to 5 m with twisted cables Minimum signal duration 50 ms Signal delay on max. 35 ms rising edge Signal delay on max. 5 ms falling edge Operating and display elements Red LED and push button for assigning the physical address Connections Push button / switch Four core pairs with plug-in connection EIB Bus connecting terminal Type of protection IP 20, EN 60 529 when inserted Protection class II Ambient temperature range Operation - 5 C 5 C Storage -25 C 55 C Transport -25 C 70 C Housing, colour Plastic housing, grey Dimensions 38 x 3 x 18 mm (H x W x D) Weight 0.05 kg Certification CE norm EIB-certified in accordance with the EMC guideline and the low voltage guideline Page 1 of 8 TSU_2_TD_EN_V1-1 2CDC 50 017 D0201

Push Button Interface, -fold, FM, GH Q605 0025 R0002 Application programs Number ofmax. number ofmax. number of communication objects group addresses associations Switch Edge Dim Shutter Value 8 20 20 Cyclic /2 Circuit diagram D C B A D C B A 1 violett pink orange wei violett pink orange wei 2 rot + schwarz - rot + schwarz - 3 5 A666807A A666807B 1 Connection for single contacts Connection for contact pairs Input A: white, black/white Input A: white, black/white Input B: orange, black/white Input B: orange, black/white Input C: pink, black/white Input C: pink, black/white Input D: purple, black/white Input D: purple, black/white 2 Programming button 5 Bus terminal 3 Programming LED Note The black/white cores form a common reference potential, enabling serial or shutter switches to be connected. Cores that are not required must be insulated. Page 2 of 8 TSU_2_TD_EN_V1-1 2CDC 50 017 D0201

Push Button Interface, -fold, FM, GH Q605 0025 R0002 Switch Edge Dim Shutter Value Cyclic /2 Selection in ETS2 The application program is specifically for use with isolated switches or push buttons. Depending on the setting, the four inputs can be used individually or as two pairs of inputs. Individual inputs can be used for switching, dimming or for sending values. Input pairs can be used for shutter control or for dimming. Cyclic If the parameter Cyclical sending is activated, the object values can be sent cyclically. It is possible to send cyclically with an object value of 0 and/or 1. The total cyclic time is calculated with a base and a factor. Cyclic time = Base * Factor ABB Input Binary input, -fold It must be specified in the general parameters Preselection of functions for input... whether the inputs are connected individually or as a pair. If the inputs are connected individually, the option switching / one-touch dimming / 8 bit value must be set while dimming / shutter should be selected when the inputs are connected in pairs. Edge The value of the communication object after the closing and/or opening of the contact is defined separately for each input with the setting Reaction on change at input. The reaction can be ON, OFF, TOGGLE or none depending on the parameterisation. The period for a long push button action and the debounce time are specified in the general parameters. The Debounce time determines how long a contact must be pressed in order for the device to accept the push button action as valid. So that the bus is not put under load with too many unnecessary telegrams, it is possible to limit the number of telegrams that the devices can send in 17 s. Switch A 1 bit communication object is available for each input when the switch function is selected. The parameter Reaction on change at input defines the current object value (see also Edge ). The parameter Sending condition on change at the input or on bus voltage recovery specifies when and whether an object value is sent. Depending on the parameter setting, it is possible to send when the contact closes and/or opens. If the object value is not to be sent at all, the parameter should be set to do not send. If the sending condition of an object value has been met, it is also possible to specify whether the input sends its current value or not on bus voltage recovery. The current values are sent approx. 1 s after bus voltage recovery. Push button function With the Function parameter, it is possible to use an input both for switching on and off. A distinction is made between a long and a short push button action. It is therefore possible e.g. to switch on with a short push button action and switch off with a long push button action. Alternatively, it could be possible to switch on with a long push button action and switch off with a short push button action. Depending on the contact type used, it is possible to set either a normally closed or a normally opened contact. One-touch dimming If the function type one-touch dimming is selected, a 1 bit communication object Telegr. switch and a bit communication object Telegr. dimming is available for the input. After a short push button action, the switching object is toggled while dimming telegrams are triggered at the dimming object after long push button operations. Whether the device dims up or down is dependent on the last dimming procedure. The dimming telegram that has been triggered always dims in the opposite direction to the last dimming telegram that was sent. The contact type can be a normally closed or normally opened contact. Page 3 of 8 TSU_2_TD_EN_V1-1 2CDC 50 017 D0201

Push Button Interface, -fold, FM, GH Q605 0025 R0002 Dim Shutter If two inputs are used as a pair for dimming, they can dim in two ways. With the setting switch/dimming sensor with stop telegram, the inputs operate with the start/stop dimming procedure i.e. a Dim brighter or Dim darker telegram is sent after a long push button action and a Stop telegram is triggered when the push button is released. Alternatively, it is possible to dim with dimming steps. This means that telegrams are triggered for the duration of the dimming process. The individual telegrams contain the size of the dimming step i.e. the percentage for dimming brighter or darker. The size of the dimming step can be defined with the parameter Long push button action - change by...%. The parameter Telegram is repeated every specifies how often this telegram is triggered. In the setting shutter sensor, two 1 bit communication objects are available for each pair of inputs. An object sends Adjust lamella / stop telegrams after a short push button action and Move shutter up/down telegrams after a long push button action. It is specified that input A (C) is used for raising the shutter and input B (D) for lowering the shutter. Value If the 8 bit value function is set, values between 0 and 255 can be sent to a 1 byte communication object. One value is sent if the contact closes or two values are sent if the contact closes or opens. With both dimming types, it is possible to set the contact type separately for each input. This can be a normally closed or normally opened contact. The behaviour after a short or long push button action is fixed. If the input parameter Input A/B is set to ON / OFF, the first (third) input switches on with a short operation and the second (fourth) input switches off. If the parameter is set to TOGGLE / TOGGLE, each input is toggled. After a long push button action at the first (second) input, a dimming brighter process occurs while a long push button action at the second (fourth) input causes the device to dim darker. If TOGGLE / TOGGLE is selected, dimming is always carried out in the opposite direction to the last dimming process after a long push button action at any input. Page of 8 TSU_2_TD_EN_V1-1 2CDC 50 017 D0201

Push Button Interface, -fold, FM, GH Q605 0025 R0002 for switch inputs 0 1 bit Input A Telegr. switch 2 1 bit Input B Telegr. switch 1 bit Input C Telegr. switch 6 1 bit Input D Telegr. switch for one-touch dimming 0 1 bit Input A Telegr. switch 1 bit Input A Telegr. dimming 2 1 bit Input B Telegr. switch 3 bit Input B Telegr. dimming 1 bit Input C Telegr. switch 5 bit Input C Telegr. dimming 6 1 bit Input D Telegr. switch 7 bit Input D Telegr. dimming for value inputs 0 1 byte Input A Telegr. value 2 1 byte Input B Telegr. value 1 byte Input C Telegr. value 6 1 byte Input D Telegr. value for dimming inputs 0 1 bit Input A / B Telegr. switch 1 bit Input A / B Telegr. dimming 1 bit Input C / D Telegr. switch 5 bit Input C / D Telegr. dimming for shutter inputs 0 1 bit Input A / B Telegr. lamella adj./stop 1 1 bit Input A / B Telegr. move shutter Up-Down 1 bit Input C / D Telegr. lamella adj./stop 5 1 bit Input C / D Telegr. move shutter Up-Down Page 5 of 8 TSU_2_TD_EN_V1-1 2CDC 50 017 D0201

Push Button Interface, -fold, FM, GH Q605 0025 R0002 General parameters General: Preselection of functions for switching / one-touch dimming / input A / B 8 bit value dimming / shutter Preselection of functions for switching / one-touch dimming / input C / D 8 bit value dimming / shutter Push button action interpreted as long from 0.3 s / / 0.5 s / / 7.0 s Debounce time 10 ms / 30 ms / 50 ms / 100 ms Limit number of telegrams yes / no Only if yes is selected: Max. number of telegrams in 17 s 30 / 60 / 100 / 127 Parameters for switch inputs, onetouch dimming or value inputs. Only for switching, one-touch dimming and 8 bit value functions: Function switching one-touch dimming 8 bit value (contact closes) 8 bit value (contact closes or opens) short/long push button action Only for switch function: Reaction on change at input contact closes: ON, contact opens: OFF contact closes: OFF, contact opens: ON contact closes: ON contact opens: OFF contact closes: OFF contact opens: ON contact closes: TOGGLE contact opens: TOGGLE contact closes: TOGGLE, contact opens: TOGGLE none Sending condition on change at the send if contact is closed input or on bus voltage recovery send if contact is opened send if contact is opened or closed do not send Only if sending is selected: Send current object value on bus yes voltage recovery no The object value depends on the reaction to the change at the input. When and whether a value is sent is dependent on the sending conditions. Cyclical sending no for ON for OFF for ON and OFF Only if cyclical sending is selected: Time base 130 / / 8. s / / 1.2 h Factor (5 127) 37 Page 6 of 8 TSU_2_TD_EN_V1-1 2CDC 50 017 D0201

Push Button Interface, -fold, FM, GH Q605 0025 R0002 Parameters for switch inputs, onetouch dimming or value inputs. Only for one-touch dimming function: Contact type normally opened contact Only for 8 bit value function (contact closes): Value if contact closes 255 (0 255) Only for 8 bit value function (contact closes or opens): Value if contact closes 255 (0 255) Value if contact opens 0 (0 255) Only for short/long push button action: Send after a short push ON / OFF button action Send after a long push ON / OFF button action Contact type normally opened contact Parameters for dimming sensor or shutter sensor functions. Only for dimming sensor and shutter sensor functions: Separately for inputs A/B and C/D: Function shutter sensor switch/dimming sensor (stop telegr.) switch/dimming sensor (dimming steps) Only for shutter sensor: Separate for each input: Contact type of input normally opened contact Short push button action adjust lamella/stop For input A (C): Long push button action move shutter up For input B (D): Long push button action move shutter down Only for switch/dimming sensor with stop telegram: Input A / B ON / OFF TOGGLE / TOGGLE Separate for each input: Contact type of input normally opened contact Only for ON / OFF: Short push button action ON For input A (C): Long push button action dim up For input B (D): Long push button action dim down Only for TOGGLE / TOGGLE: Short push button action TOGGLE Long push button action dim up/down Page 7 of 8 TSU_2_TD_EN_V1-1 2CDC 50 017 D0201

Push Button Interface, -fold, FM, GH Q605 0025 R0002 Parameters for dimming sensor and shutter sensor functions. Only for switch/dimming sensor with dimming steps: Input A / B ON / OFF TOGGLE / TOGGLE Long push button action change by 100% change by 50% change by 25% change by 12.5% change by 6.25% change by 3% change by 1.5% Telegram is repeated every 0.3 s / / 0.5 s / / 7.0 s Separate for each input: Contact type of input normally opened contact Only for ON / OFF: Short push button action ON For input A (C): Long push button action dim up For input B (D): Long push button action dim down Only for TOGGLE / TOGGLE: Short push button action TOGGLE Long push button action dim up/down Page 8 of 8 TSU_2_TD_EN_V1-1 2CDC 50 017 D0201