Manual Release 09/2002. cm-eib FOR LOGO! Communication with LOGO! with EIB and the Konnex standard

Similar documents
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Product and functional description

Modular I/O System Analog and Digital Interface Modules

TX OPEN RS232/485 module

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Digital input modules

Universal Serial Bus (USB) to DH-485 Interface Converter

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

PCS0100en Persy Control Services B.V. Netherlands

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB i-bus KNX SA/S Switch Actuators Product Manual

EIB/KNX IP Interface with Power over Ethernet (PoE)

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

ADM1TE 5/30A DIN rail single phase two wire energy meter

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

KNX Interface. User Manual PM00A00IRI

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

DALI RC BASIC SO. Control unit Operating instructions

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Inwall 4 Input / 4 Output Module

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

StructureScan HD Module. Installation Guide ENGLISH

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Install the DeviceNet Module using the following procedure:

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Safety technique. Emergency stop module BO 5988 safemaster

Manual. Simrad StructureScan LSS-1 Sonar Module. English

ABB i-bus EIB Logic Module LM/S 1.1

How To Use A Power Supply On A Powerline 2.2 (Ai)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Inwall Room Temperature Unit

KNX Gateway RGK E-01

is then retained absolutely without interruption.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ACS-30-EU-EMDR-10-MOD

Permissible ambient temperature Operation Storage, transport

IntesisBox KNX Mitsubishi Heavy Industries AC

PHOENIX CONTACT Features

Air damper actuators

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

L5354 ControlNet Communications Interface

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

5SV Residual Current Protective Devices

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

CompactLogix Power Supplies Specifications

Drayton Digistat +2RF/+3RF

gesis KNX RM Manual Installation System for European Installation Bus Product and Object Description Doc. no. BA Wieland Electric GmbH

ABB i-bus KNX Fan Coil Controller FC/S 1.1

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Actuator-Sensor-Interface

MINI MCR-SL-R-UI(-SP)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

instabus KNX / EIB System System E F G H

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

4KVA/5KVA Parallel Installation Guide

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Cross-beam scanning system to detect slim objects. 100 mm in

Disturbance Recoder SPCR 8C27. Product Guide

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

User Manual Revision English

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

WEB log. Device connection plans

PCAN-ISA. CAN Interface for ISA. User Manual

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

BroadBand PowerShield. User Manual

CONFIGURABLE SAFETY RELAYS

Transcription:

Manual Release 09/2002 cm-eib FOR LOGO! Communication with LOGO! with EIB and the Konnex standard

s /KNX LOGO! Expansion Module Manual Chapters Safety Notices 1 Getting to know 2 Mounting and wiring the 3 Putting the into operation 4 Supported functions 5 specifications INDEX

Copyright - Siemens AG 1996 to 2002 All rights reserved You may not transfer or duplicate this document or utilize or reveal its contents, unless expressly authorized in writing. In the case of a violation, you will be obliged to pay damages. All rights reserved, in particular in the event that a patent is granted or that a utility model is registered. Disclaimer of liability: We have checked that the contents of this document correctly describe the associated hardware and software. Nonetheless, it is impossible to exclude the possibility of deviations and therefore we cannot guarantee that there are no errors in this document. The information in this document is checked regularly and any necessary corrections are then made in the next release issued. We are of course thankful for any suggestions for improvements. 2 J31069-D1262-U002-A4-7618

Table of Contents Safety Notices 1 Getting to know... 5 1.1 What is the?... 5 1.2 The construction of the... 6 2 Mounting and wiring the /KNX... 7 2.1 General guidelines... 7 2.2 Wiring the... 9 2.2.1 Connecting the power supply 10 2.2.2 Connecting the EIB 11 3 Putting the into operation... 12 3.1 Step-by-step... 12 3.2 The - operational status... 13 3.3 Behavior in case of a fault... 15 4 Supported functions... 16 4.1 Inputs / Outputs... 16 4.2 Available communication objects... 18 4.3 EIB configuration... 19 5 - Specifications... 22 J31069-D1262-U002-A4-7618 3

Safety Notices DANGER Indicates that death, severe bodily injury or substantial material damage will occur, if the corresponding safety measures are not taken. WARNING Indicates that death or severe bodily injury may occur, if the corresponding safety measures are not taken. CAUTION With the warning triangle, this indicates that minor bodily injury may occur, if the corresponding safety measures are not taken. CAUTION Without the warning triangle, this indicates that material damage may occur, if the corresponding safety measures are not taken. WARNING This indicates that an undesirable result or condition may occur, if the corresponding instructions are not observed. 4 J31069-D1262-U002-A4-7618

1 Getting to know 1.1 What is the? This is the communications module (CM) for connecting the LOGO! to the EIB bus. The LOGO! communications module has been implemented as a Slave module for the LOGO control module (12/24 or 115/240 Volt). The module supports communication between the LOGO! Master and external EIB devices via an EIB. The CM is a bus participant on the EIB and allows the LOGO! to communicate with other EIB devices using EIB telegrams. What are the capabilities of the? The CM transfers EIB telegrams to the LOGO! and LOGO! functions to the EIB. The CM presents the current states of the EIB devices to the LOGO!, which is thus able to use its logical functions und timers to join them together. In the process, the EIB signals can also be combined with the signals of the local LOGO! inputs and outputs. The CM then transmits every change of the output signal via the EIB. The combination of LOGO! and gives the user a decentralized controller functionality for the EIB with the capability of setting or changing parameters or operations quickly, simply and without a programming device. J31069-D1262-U002-A4-7618 5

1.2 The construction of the 1. Power supply 2. Bus lock slide, interface to the LOGO! 3. The RUN/STOP LED for communication with LOGO! 4. The BUS LED, EIB communications 5. Label for the physical address 6. Inputs - EIB connection 7. Expansion interface to the LOGO! 8. Mechanical coding - pin 9. Programming button 6 J31069-D1262-U002-A4-7618

2 Mounting and wiring the /KNX 2.1 General guidelines The following guidelines must be observed when mounting and wiring your : When wiring the, make certain that you follow all of the applicable and legally binding standards. Observe all of the relevant national and regional regulations when installing and operating the device. Check with the local authorities regarding the standards and regulations that must be observed in your special case. Make certain that the device is de-energized. Use only approved bus cables. The EIB bus cables may also be laid parallel to other lines. The must always be installed as the last module on the right of the LOGO!, since you may not install other expansion modules onto the. J31069-D1262-U002-A4-7618 7

Please note: - The must have its own voltage supply (24V). NOTE This module may only be mounted and wired by qualified personnel, who know and observe the generally applicable guidelines and applicable regulations and standards. Observe the assembly and disassembly instructions in the LOGO! manual. WARNING The expansion module may only inserted or removed when the power is off. 8 J31069-D1262-U002-A4-7618

2.2 Wiring the To wire the, use a screwdriver with a 3 mm wide blade. There is no difference between the terminals of the LOGO! and the EIB. NOTE To protect personnel against unintentional contact with the portions of the that are conducting electricity, the appropriate national and local standards must be observed. The is a double-insulated switching device. A protective grounding conductor is not necessary. J31069-D1262-U002-A4-7618 9

2.2.1 Connecting the power supply The has been designed to serve as a Slave module for the LOGO! controller. It must be connected to a 24 V AC/DC supply voltage. Please observe the relevant instructions that are found in product information that was included with your equipment as well as the technical data regarding the permissible voltage tolerances, mains frequency and current consumption. Connecting How to connect the to the power:... with... with DC supply AC supply Protect with a 80 ma/slow action fuse, if desired (recommended). 10 J31069-D1262-U002-A4-7618

2.2.2 Connecting the EIB This connection is made using the two screw terminals (+ and -). RUN/STOP BUS 6BK1700-0BA00-0AA0 X 2 3 4 Prog. + - EIB red black Only the red black pair is used, the white yellow pair is not connected. You can set the in the programming mode by pressing on the Prog button. NOTE Don't apply too much force when pressing the Prog button. When contact has been made, the LED will light up in orange. J31069-D1262-U002-A4-7618 11

3 Putting the into operation 3.1 Step-by-step 1. Both the BUS and supply voltage must be present. 2. Connect a PC to the serial EIB interface. 3. Start ETS. Use ETS2 Version 1.2. 4. Use ETS2, V.1.2 to configure the application program. 5. The application program is loaded into the devices via the EIB interface. The application program is available for downloading from the LOGO! homepage (http://www.siemens.de/logo). 6. In ETS, click on Program Physical Address. 7. Press the button on the to set the in programming mode; the LED will light up in orange. 8. When the LED goes out, the physical address has been programmed. You can now note the physical address on the device. The syntax of the physical address: Area / Line / Device XX / XX / XXX 12 J31069-D1262-U002-A4-7618

9. The application program can now be loaded. Afterwards, the device is ready for operation. RUN/STOP BUS 6BK1700-0BA00-0AA0 X 2 34 Prog. + - EIB red black 10. If multiple s have been installed in an EIB system, repeat Steps 1 to 9 for each. 11. For further details regarding the EIB installation, please read the corresponding documentation. 3.2 The - operational status The is a LOGO! expansion module. This module has two LED displays: 1. RUN/STOP LED Communication with the LOGO! 2. BUS LED EIB-Bus status J31069-D1262-U002-A4-7618 13

The RUN/STOP LED will light in green, red or orange. LED Lights In Green (RUN) Red (STOP) Orange The expansion module is communicating with the device on the left. The expansion module is not communicating with the device on the left. The BUS LED will light in green, red or orange. The expansion module's initialization phase LED Lights In Green Red Orange Bus connection OK, communication OK, not programming mode Bus connection fault Programming mode active and bus connection OK L+ M AC/DC 24V / KNX RUN/STOP BUS 6BK1700-0BA00-0AA0 X 2 3 4 Prog. + - EIB 14 J31069-D1262-U002-A4-7618

3.3 Behavior in case of a fault LOGO! - Power failure If the power to the LOGO! fails or the communications with the LOGO! Master or the communications partner to the left is interrupted, the outputs will be set to 0. The RUN/STOP LED will light in RED after one second. LOGO! - Power returns The LOGO! will startup and the CM will send the parameterized status. CM - Power failure All of the inputs of the EIB's LOGO! Master will be set by the LOGO! Master to 0. CM - Power returns All of the LOGO!Master outputs on the EIB will be updated. The inputs will be depending on the EIB parameters read. BUS - Short-circuit or interruption The inputs and outputs will retain their last value until they receive a new one. After 5 seconds, the Bus LED will light in red. BUS - Restored When the BUS is restored, the CM remains neutral, i.e. it does not send any telegrams. J31069-D1262-U002-A4-7618 15

4 Supported functions The supports the communications between the LOGO! and EIB and supplies the I/O necessary for the communication via the EIB. 4.1 Inputs / Outputs The standard application fills the complete LOGO! process image. A1 A2 I1 I2 I3 I4 I5 I6 I7 I8 LOGO! 12/24 RC CM-EIB/KNX Q1 Q2 Q3 Q4 A3... A8 I9... I24 Sensorik EIB (Instabus) Q5... Q16 Aktorik I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 230 RC DM8 AM2 /KNX Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 A 1 A2 A3... A8 I13... I24 Sensorik EIB (Instabus) Q9... Q16 Aktorik 16 J31069-D1262-U002-A4-7618

Sample application: LOGO! I1 I2 I3 I4 I5 I6 I7 I8 DM 8 I9I10I11I12 /KNX 1 I9 Q9 2 I1 I14 & Q16 Q6 3 Q1 I13 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 I13... I24 Q9... Q16 EIB (Instabus) 1. To map the LOGO! inputs (I1 to I8and I9 to I12) as outputs on the EIB, these must be joined with free EIB outputs (Q9 to Q16) in the LOGO! application. 2. Operations (basic functions BF / special functions SF) useable within the LOGO! application (e.g. as a feedback signal). 3. To access the LOGO! application (Q1 to Q4 and Q5 to Q8) directly via the bus communications, these must be joined with free EIB inputs (I13 to I24) in the LOGO! application. J31069-D1262-U002-A4-7618 17

4.2 Available communication objects An example of the basic variant LOGO! CPU and without an expansion module: The following communication objects will be available on the EIB / KNX Bus: EIB-Object No. Type (Size) EIS IN / OUT 0 UINT1 EIS1 I9 Input 1 UINT1 EIS1 I10 Input 2 UINT1 EIS1 I11 Input 3 UINT1 EIS1 I12 Input 4 UINT1 EIS1 I13 Input 5 UINT1 EIS1 I14 Input 6 UINT1 EIS1 I15 Input 7 UINT1 EIS1 I16 Input 8 UINT1 EIS1 I17 Input 9 UINT1 EIS1 I18 Input 10 UINT1 EIS1 I19 Input 11 UINT1 EIS1 I20 Input 12 UINT1 EIS1 I21 Input 13 UINT1 EIS1 I22 Input 14 UINT1 EIS1 I23 Input 15 UINT1 EIS1 I24 Input 16 UINT1 EIS1 Q5 Output 17 UINT1 EIS1 Q6 Output 18 UNIT1 EIS1 Q7 Output 19 UINT1 EIS1 Q8 Output 20 UINT1 EIS1 Q9 Output 21 UINT1 EIS1 Q10 Output 22 UINT1 EIS1 Q11 Output 23 UINT1 EIS1 Q12 Output 24 UINT1 EIS1 Q13 Output 25 UINT1 EIS1 Q14 Output 26 UINT1 EIS1 Q15 Output 27 UINT1 EIS1 Q16 Output 28 UINT16 / UINT8 EIS5 / EIS6 AI1 Input 29 UINT16 / UINT8 EIS5 / EIS6 AI2 Input 30 UINT16 / UINT8 EIS5 / EIS6 AI3 Input 31 UINT16 / UINT8 EIS5 / EIS6 AI4 Input 32 UINT16 / UINT8 EIS5 / EIS6 AI5 Input 33 UINT16 / UINT8 EIS5 / EIS6 AI6 Input 34 UINT16 / UINT8 EIS5 / EIS6 AI7 Input 35 UINT16 / UINT8 EIS5 / EIS6 AI8 Input EIS1 (switches) 1 Bit EIS 5 (EIB floating) 2 byte value EIS 6 (EIB floating) 1 byte value 18 J31069-D1262-U002-A4-7618

4.3 EIB configuration The following application parameters can be set in ETS2, V.1.2: - The number of digital I/Os on the LOGO! Master or expansion modules - The number of analog inputs on the LOGO! Master or expansion modules - The data type for each analog input EIS6 (scaling/8-bit with sign) or EIS5 (EIB-Value Temp/8-bit without sign). In the parameter dialog, you can set the number of inputs and outputs that are already on the LOGO! (including expansion modules) and how many are available via the EIB. J31069-D1262-U002-A4-7618 19

The EIS5 values are converted to a fixed point numerical value with a resolution of 0.1, which equates to a value range of 3276.8 (FFFFh) to +3276.7 (7FFFh). EIS6 values for scaling are accepted, i.e. 0 to 100 % corresponds to an analog value of 0 to 255. Unused analog inputs must be set to Not Used. 20 J31069-D1262-U002-A4-7618

Inputs/Outputs Special Considerations When using the LOGO! I/O on the, you must consider the following. To access the LOGO! outputs (Q1 to Q4) directly via communication over the bus, these must be joined in the LOGO! application with free EIB inputs. To map the LOGO! inputs (I1 to I8) as outputs on the bus, these must be joined in the LOGO! application with free EIB outputs. The outputs on additional I/O modules can also be transferred in parallel via the EIB. J31069-D1262-U002-A4-7618 21

5 - Specifications Electrical Data Supply voltage 24 V AC 24 V DC Permissible range -15% +10% -15% +20% Current consumption (power supply) max. 25 ma Current taken from BUS 5 ma EIB data transfer rate 9600 Baud Physical Construction Standard width Dimensions (W x H x D) Weight Mounting options Operational status display Controls 2 SU 36 x 90 x 55 mm approx. 50 g 35 mm rail wall mounting RUN/STOP LED - communications with LOGO! BUS LED communications with EIB/KNX EIB/KNX programming button S1 Connections LOGO! connection EIB connection (TP 256) max. torque Power supply max. torque Standard bus lines to use Digital inputs (I) - virtual max. 16 Digital outputs (Q) - virtual max. 12 Analog inputs (AI) - virtual max. 8 Max. group addresses 64 Max. associations 64 Standard expansion interface for LOGO! 12/24 V and 115/240 V 2 screw terminals (0.5 2.5 mm²) 0.5 Nm 2 screw terminals (0.5 2.5 mm²) 0.5 Nm YCYM or J-Y(ST)Y (2 x 2 x 0.8 mm²) Environmental Conditions Permissible operating temperature Storage and transport temperatures Humidity 0 C to +55 C free convection -40 C to +70 C 95% at +25 C 22 J31069-D1262-U002-A4-7618

Safety Protection standard IP 20 Radio interference suppression EN 55011 (Limit Value Class B) Certification CE EIB/KNX UL 508 VDE 0631 IEC 61131-2 Overvoltage protection Fuse 80 ma slow action fuse Order Data LOGO! Expansion Module EIB/KNX CM 6BK1700-0BA00-0AA0 J31069-D1262-U002-A4-7618 23

INDEX EIB EIS ETS KNX European Installation Bus EIB Interoperability Standard EIB Tool Software Standard of the Konnex Association 24 J31069-D1262-U002-A4-7618

Siemens Aktiengesellschaft Automation and Drives Systems Engineering PO. 2355, D-90713 Fürth www.siemens.com Order No. J31069-D1262-U002-A4-7618