Portal Frame Bracing Without Hold-Down Devices

Similar documents
POST AND FRAME STRUCTURES (Pole Barns)

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Chapter 6 ROOF-CEILING SYSTEMS

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

6 RETROFITTING POST & PIER HOUSES

Residential Deck Safety, Construction, and Repair

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Supplement to IRC Wall Bracing Guide: Design Examples

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Featuring TJ Rim Board and TimberStrand LSL

Perforated Shearwall Design Method 1

PERFORMANCE RATED I-JOISTS

STANDARD OPEN PATIO COVER

Residential Decks. Planning and Development Services Department

Uncovered Decks & Porches

Glulam Appearance Classifications for Construction Applications

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

TYPICAL PATIO COVERS 111

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

8/18/14. Introduction to. Framing. Terminology and Concepts

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Owner s Guide to Understanding Checks in Glued Laminated Timber

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

Wisconsin Building Products Evaluation

Page & Turnbull imagining change in historic environments through design, research, and technology

Design of Cold-Formed Steel Shear Walls

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

MUNICODE SERVICES LTD.

Section A Roof Truss

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

LP OSB Sheathing & Structural 1 Sheathing

COMMONLY USED RESIDENTIAL BUILDING CODES

Timber Frame Construction

Formwork for Concrete

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

CPA Steel Stud Framing Page 1 of 11

Bracing Webs in Trusses that have Dissimilar Configurations

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Chapter 10 - Scaffolding Systems

Structural Design for Residential Construction

2015 UCC Residential Code Update

Superform Products Ltd.

Residential Foundations and Basements

Breakaway Walls

March 14, Installation of Bay, Bow and Garden Windows

Post and Beam Construction

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

Load-Span Tables for PS-1 Plywood

Guidelines for Earthquake Bracing of Residential Water Heaters

Development Services City of Lawrence, KS

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Handling, Erection and Bracing of Wood Trusses

ICC-ES Evaluation Report

Protecting Your Home From Hurricane Wind Damage

OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

Typical Deck Details

Fastener Loads for Plywood Screws Number E830D August 2005

research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Protecting Your Home from Wind Damage

What is Seismic Retrofitting?

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

Mark Cramer Inspection Services, Inc.

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Discipline: Structural Issued

1/2" CDX PLY W/ 6"/ 6"/ 12" 2x ROOF 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

NORDIC ENGINEERED WOOD RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC JOISTTM FSC-CERTIFIED PRODUCTS AVAILABLE

Diaphragms and Shear Walls DESIGN/CONSTRUCTION GUIDE

PART 1 GENERAL 1.1 SECTION INCLUDES

Introduction...COMB-2 Design Considerations and Examples...COMB-3

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

INFORMATION BULLETIN NO.

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

Wood Truss Restraint and Bracing Guide

Residential Plan Routing Information

Guidelines for Earthquake Bracing Residential Water Heaters

System Report SR-405B DECEMBER 2014

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Renovating Your Basement

SIGNIFICANT CHANGES to the 2015 Minnesota Residential Codes (MR 1303, 1309 and 1322)

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

SUPER SHED. Indoor shelter for your outdoor tools.

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

How to secure your property after a disaster

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

PUMP JACK SYSTEM AND ACCESSORIES

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Georgia Association of Home Inspectors

The minimum reinforcement for the stem wall is the placement of:

Additions and Alterations

CITY OF LOS ANGELES CALIFORNIA

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Transcription:

T E C H N I C A L N O T E Portal Frame Bracing Without Hold-Down Devices FOR USE IN CONTINUOUSLY SHEATHED WALLS Number J740 July 2008 BACKGROUND Wall bracing is required by the International Residential Code (IRC) to resist wall racking due to wind or seismic forces. Historically, wall bracing segments had to be a minimum of 48 inches in width. With modern home designs maximizing windows and minimizing wall sections, finding 48 inches to count toward bracing can be a challenge. APA developed the portal frame for wall bracing to help provide a segment as narrow as 16 inches that can be counted toward the overall bracing amount required by the code. The portal frame design relies on additional nailing and a semi-rigid connection between the wall segment sheathing and header to improve performance in a narrow wall segment. For information on IRC wall bracing requirements, refer to APA s publication, Introduction to Wall Bracing, Form F430. This portal frame without hold downs is also sometimes referred to as 6:1 aspect ratio segments used with continuous structural panel sheathing and/or the APA narrow wall bracing method. This portal frame design has been tested to show bracing performance comparable to existing code-permitted bracing for residential structures. APA and three other independent labs have conducted nearly 100 cyclic tests (1) showing that the 16-inch-wide portal frame design used in a continuously sheathed wood structural panel wall, with a 6:1 aspect ratio as measured at the vertical wall segment, performs comparably to wood structural panel wall bracing segments currently permitted in the IRC. The portal frame segment depicted in Figure 1 provides bracing performance that is comparable to other continuously sheathed wood structural panel bracing segments, on strength per foot of bracing basis. This bracing method is recognized in the 2006 IRC Table R602.10.5 footnote c, where it is limited to installations next to garage doors only, with up to a story above, and only in Seismic Design Category A-C. Significant expansion of the IRC provisions can be seen in the 2007 IRC Supplement where the bracing segment is listed in Section R602.10.4.6, and can be used anywhere in the dwelling (not just next to garage doors) and in any seismic design category. The 2007 IRC Supplement also includes provisions for not only how this segment resists in-plane wall racking loads, but also how this segment resists out-of-plane wind loads (those acting perpendicular to the wall). This is a unique strength advantage over all other IRC bracing methods. Section R301.2.1 of the IRC requires that wall coverings and garage doors be able to resist the design wind pressures, and Section R601.2 of the IRC requires that wall construction be capable of accommodating all loads imposed. Garage doors, for example, collect a large area of wind pressure and impose large loads on the adjacent wall framing. For the portal frame to resist these loads perpendicular to the wall, provisions included in Table 1 and Figures 1 3 have been developed. Current APA recommendations for using this bracing segment follow and closely reflect what is expected to appear in the 2009 IRC. (2)

2 APA RECOMMENDATIONS Wall segments having a maximum 6:1 aspect ratio shall be permitted to be built in accordance with Figures 1 3 and Table 1. The maximum 6:1 aspect ratio is based on height being measured from the top of the header to the bottom of the wall segment bottom plate. For purposes of calculating the percentage of bracing present in the braced wall line, i.e., per 2006 IRC Table R602.10.1, the width of the full height sheathing segment shall be equal to its measured width. For example, a portal frame without hold downs with a 16-inch-wide wall segment is counted as 16 inches of bracing. If applicable, the bracing amount reduction factors (0.8 or 0.9 from 2006 IRC Section R602.105) for continuously sheathed braced walls next to given openings shall be applied when calculating the total amount of wall bracing required for the entire braced wall line. FIGURE 1 WALLS WITH 6:1 ASPECT RATIO USED WITH CONTINUOUS WOOD STRUCTURAL PANEL SHEATHING OUTSIDE ELEVATION Extent of header (two braced wall segments) Extent of header (one braced wall segment) SIDE ELEVATION 12' max. total wall height 1 Pony wall height (a) 10' max. height Note: (a) See Table 1 Braced wall segment per IRC Table R602.10.4 Min. 3" x 11-1/4" net header 2' to 18' (finished opening width) Fasten sheathing to header with 8d common nails (0.131" x 2-1/2") in 3" grid pattern as shown and 3" o.c. in all framing (studs and sills) typ. Header shall be fastened to the king stud with 6-16d sinker nails (0.148" x 3-1/4") Minimum 1,000 lb strap shall be centered at bottom of header and installed on backside as shown on side elevation (a) For a panel splice (if needed), panel edges shall be blocked and occur within middle 24" of wall height Wood structural panel strength axis Min. number of studs shown (a) Min. length based on 6:1 aspect ratio. For example:16" min. for 8' height. Anchor bolt per IRC Table R403.1.6 typ. Min. 2"x2"x3/16" plate washer OVER CONCRETE OR MASONRY BLOCK FOUNDATION No. of jack studs per IRC Table R502.5(1&2) Min. 1,000 lb tension strap. (a) Strap shall be centered at bottom of header. 16d sinker nails (0.148" x 3-1/4") in 2 rows @ 3" o.c. Wood structural panel must be continuous from top of wall to bottom of wall, or from top of wall to permitted splice area 7/16" min. thickness wood structural panel sheathing Not to scale

3 FIGURE 2 BRACING METHOD OVER RAISED WOOD FLOOR OR SECOND FLOOR FRAMING ANCHOR OPTION (a)(b) Outside Elevation Side Elevation Min. 670 lb framing anchors (b) (Ref. No. LTP4) Nail sole plate to joist per IRC Table R602.3(1) Nail sole plate to joist per IRC Table R602.3(1) Wood structural panel sheathing over approved band joist Approved band joist Framing anchors installed per the anchor manufacturer s recommendation Notes: (a) See Figure 1 for complete framing detail. (b) Framing anchors may also be rotated vertically. Use engineered wood Rim Board, I-joist, or DRY lumber rim joist to minimize potential for buckling over band joist Not to scale FIGURE 3 BRACING METHOD OVER RAISED WOOD FLOOR OR SECOND FLOOR WOOD STRUCTURAL PANEL OVERLAP OPTION (a) Outside Elevation Min. Overlap 9-1/4" Nail sole plate to joist per IRC Table R602.3(1) 8d common nails (0.131" x 2-1/2") 3" o.c. top and bottom Side Elevation Nail sole plate to joist per IRC Table R602.3(1) Wood structural panel sheathing over approved band joist Approved band joist Use engineered wood Rim Board, I-joist, or DRY lumber rim joist to minimize potential for buckling over band joist Note: (a) See Figure 1 for complete framing detail. Not to scale

4 TABLE 1 TENSION STRAP CAPACITY REQUIRED FOR RESISTING WIND PRESSURES PERPENDICULAR TO 6:1 ASPECT RATIO WALLS (a)(b) Minimum Wall Stud Framing Size and Grade (Nominal) Maximum Pony Wall Height (ft) Maximum Total Wall Height (ft) Maximum Opening Width (ft) Basic Wind Speed (mph) 85 90 100 85 90 100 Exposure B Exposure C Tension strap capacity required (lbf) (a)(b) 0 10 18 1000 1000 1000 1000 1000 1000 1 10 9 1000 1000 1000 1000 1000 1275 16 1000 1000 1750 1800 2325 3500 9 1000 1000 1025 1075 1550 2500 2x4 No. 2 2 10 16 1525 2025 3125 3200 3900 NP Grade 2 12 9 1000 1200 2075 2125 2750 4000 16 2600 3200 NP NP NP NP 4 12 9 1775 2350 3500 3550 NP NP 16 4175 NP NP NP NP NP 9 1000 1000 1325 1375 1750 2550 2 12 2x6 Stud 16 1650 2050 2925 3000 3550 NP Grade 9 1125 1500 2225 2275 2775 3800 4 12 16 2650 3150 NP NP NP NP (a) NP = not permitted (b) Strap shall be installed in accordance with manufacturer s recommendations.

5 Corners at ends of continuously sheathed braced walls shall be constructed in accordance with 2006 IRC Figure R602.10.5, shown in Figure 4 in this document. The total number of braced wall segments having a maximum 6:1 aspect ratio in any individual braced wall line shall not exceed four. For purposes of resisting wind pressures acting perpendicular to the wall, as described above, the requirements of Figures 1, 2 or 3, and Table 1 shall be met. There shall be a maximum of two braced wall segments per header and header length shall not exceed 22 feet. Tension straps shall be installed in accordance with the manufacturer s recommendations. FIGURE 4 EXAMPLE OF REQUIRED OUTSIDE CORNER DETAIL (IRC FIGURE R602.10.5) 16d nail at 12" o.c. Orientation of stud may vary Gypsum, when required, installed in accordance with IRC Chapter 7 Wood structural panel At corners, connect the two walls together as outlined in this detail to provide overturning restraint. For sizing the header to resist gravity loads (snow, live, or dead), the following resources are available: 2006 IRC Section R502.5 The Wood Frame Construction Manual (WFCM) Tables 3.22A-3.22E APA publication, Glulam Garage Door Headers Offer Design Options, Form C410. APA publication, Glued Laminated Beam Design Tables, Form S475. The minimum header size of 3" x 11-1/4" is required for in-plane lateral load resistance. A deeper, thicker header may be required for gravity load resistance depending on building geometry, framing layout, and number of stories above. Like all header sizing, the proper size shall be determined by the design professional responsible for the particular project. PORTAL FRAME WITH HOLD DOWNS Additional information is also available on the portal frame with hold downs for use as a wall bracing segment in APA Technical Topic, A Portal Frame With Hold Downs for Wall Bracing or Engineered Applications, Form TT-100. The portal frame bracing segment with hold downs is described in 2006 IRC Section R602.10.6.2 and has limitations for stories constructed above the portal frame. It also has additional foundation size and reinforcement requirements, but the 16-inch wall length of a portal frame with hold downs counts as 48 inches of bracing. (1) Cyclic Response of Narrow Wall Bracing for Seismic Design, http://www.apawood.org/docs/narrowwallbracingandseismicdesign.pdf (2) International Code Council 2007/2008 code development cycle result of the public hearings in Palm Beach, CA, February 2008.

We have field representatives in many major U.S. cities and in Canada who can help answer questions involving APA trademarked products. For additional assistance in specifying engineered wood products, contact us: APA HEADQUARTERS 7011 So. 19th St. Tacoma, Washington 98466 (253) 565-6600 Fax: (253) 565-7265 PRODUCT SUPPORT HELP DESK (253) 620-7400 E-mail Address: help@apawood.org DISCLAIMER The information contained herein is based on APA The Engineered Wood Association s continuing programs of laboratory testing, product research and comprehensive field experience. Neither APA, nor its members make any warranty, expressed or implied, or assume any legal liability or responsibility for the use, application of, and/or reference to opinions, findings, conclusions or recommendations included in this publication. Consult your local jurisdiction or design professional to assure compliance with code, construction and performance requirements. Because APA has no control over quality of workmanship or the conditions under which engineered wood products are used, it cannot accept responsibility for product performance or designs as actually constructed. Form No. J740/Issued July 2008