Control module CP-A CM

Similar documents
Three-phase monitoring relay CM-PFE

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic overload relay EF65, EF96 and EF146

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Electronic overload relay EF19 and EF45

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Analog signal converters CC-E I/I Current / current isolators

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Pluggable interface relays CR-P Pcb relays

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Catalog. Modular DIN rail components Installation contactors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Thermistor motor protection

Type: DILM9 10(24VDC) Article No.:

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RM4TG20 three-phase network control relay RM4-T - range V

49 Series - Relay interface modules A. Features

48 SERIES Relay interface modules 10 A

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Manual motor starter MS116

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Bimetallic Overload Relay Specifications

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Safety technique. Emergency stop module BO 5988 safemaster

PHOENIX CONTACT Features

Technicaldata General

Manual Motor Starter MS 116 up to 16 A Technical Data

Technical catalogue. Modular DIN rail components Installation contactors

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Power Supplies 3. SDN-P DIN Rail Series

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Redundancy Module QUINT-DIODE/40

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

System pro M compact Miniature Circuit Breaker S 200/S 200 M

38 Series - Relay interface modules A

mecotron Safety relay ESTOP-2 For emergency stop monitoring

ZS25 Screw Clamp Terminal Blocks Feed-through

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuators SA/S Product Information

E-STOP relays, safety gate monitors

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

38 Series - Relay interface modules A

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

5SV Residual Current Protective Devices

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

ABB i-bus KNX SA/S Switch Actuators Product Manual

Three-phase monitoring relays Product group picture

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

MasterINTERFACE 39 Series - Relay interface modules

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

RY2 miniature industrial relays

Contact expansion modules

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

PNOZsigma - Base units

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

MasterINTERFACE 39 Series - Relay interface modules

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Relés e Contatores de Estado Sólido SIRIUS

EMR measuring and monitoring relays

Contact expander modules

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

EBS852 (Contrac) Power Electronic Unit

R.C.C.B. s two-pole LEXIC

Low Voltage Products. Switches Automatic Transfer Switches

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Safety automation solutions

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

DLP-PU/E Instruction Manual

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Transcription:

2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel a SENSE OUT: +, +, : terminals output b IN 1: 11 12/14, IN 2: 21 22/24: terminals input c IN 1 < V: rotary switch threshold value adjustment for channel 1 d IN 2 < V: rotary switch threshold value adjustment for channel 2 e OUT: green LED output voltage > 3 V f IN 1: green LED input voltage at channel 1 OK g IN 2: green LED input voltage at channel 2 OK h Circuit diagram Approvals H UL 60950, CAN/CSA C22.2 No. 60950 D GOST K CB scheme Marks a CE b C Tick pending Order data Type Description Order code Control module The CP A CM provides monitoring of the input signals of the redundancy unit CP A RU. Application The control module CP A CM provides monitoring of the input signals of the redundancy unit CP A RU. Operating mode Control of input voltages of CP A RU with CP A CM The control module CP A CM indicates the presence of both input voltages of the CP A RU via LEDs and energized output relays. The threshold values for the output relays are adjustable separately per channel from 14 to 28 V. If, by a fault (e.g. failure of a power supply, blown fuse), the voltage in a channel drops below the adjusted threshold value, the corresponding output relay de energizes. The green LEDs IN 1, IN 2 glow, if the corresponding voltage exceeds the adjusted threshold value. The green LED OUT glows, if the output voltage is higher than 3 V. 1

Example(s) of application CP A RU with CP A CM for monitoring of two power supplies In case of fault: Fault signal If both relays are de energized, the voltages of both channels are below the adjusted threshold value (e.g. 20 V). This could mean, that both power supply units failed or are switched off, or that there is an overload on the secondary side. Momentary de energization of the relays may be caused by inrush current of a connected load, during starting. If one of the two relays de energizes, this can indicate that the primary power supply unit failed or is switched off, and the redundant power supply is now supplying power to the load. + - + - CP-A RU CP-S / CP-C CP-S / CP-C Relay message channel 1 < 20 V + + - - Load Relay message channel 2 < 20 V 2CDC 272 028 F0205 CP A RU with CP A CM for monitoring of one power supply In case of fault: Transfer to an alternative power supply The following example of application shows transferring to an alternative power supply (in this example a battery) after a failure in the primary power supply unit. + - + - CP-A RU CP-S / CP-C Battery L1 N PE L N PE + + - - Load 2CDC 272 029 F0205 Installation Mounting The module is plugged and fixed as shown in the accompanying picture onto the front side of the redundancy unit CP A RU. Doing so, the pre cut front foil of the redundancy unit is penetrated by the latching hooks and the plug contacts. The module must not be plugged in when the power is on. 2CDC 272 073 F0b04 2

Installation Demounting The module is removed as shown in the accompanying picture. The module must not be removed when the power is on. 2CDC 272 074 Fb004 Electrical connection Output side [SENSE OUT ++ ] The terminals SENSE OUT + + are situated on the + and potential on the output side and can be used for signalling. Electrical connection Input side [IN 1 (11 12/14) and IN 2 (21 22/24)] Message input 1 OK Volt free (dry/floating) change over contact: 11 14 closed and 11 12 open, if the voltage in channel 1 (IN 1) of the CP A RU exceeds the threshold value adjusted at IN 1 <V. 11 12 closed and 11 14 open, if the voltage in channel 1 (IN 1) of the CP A RU drops below the threshold value adjusted at IN 1 <V. Message input 2 OK Volt free (dry/floating) change over contact 21 24 closed and 21 22 open, if the voltage in channel 2 (IN 2) of the CP A RU exceeds the threshold value adjusted at IN 2 <V. 21 22 closed and 21 24 open, if the voltage in channel 2 (IN 2) of the CP A RU drops below the threshold value adjusted at IN 2 <V. Connection diagram(s) IN1 IN2 Sense OUT + + - 11 12 14 21 12 11 14 22 21 24 2CDC 272 050 F0b07 22 24 IN 1 11 12/14 IN 2 21 22/24 Sense OUT +, +, Message input 1 (IN 1) OK Message input 2 (IN 2) OK + and potential of the output side 3

Technical data Data at T a = 25 C, U in = 230 V AC and rated values, unless otherwise indicated Input circuits - Supply circuits Rated input voltage U in Typical power consumption 24 V DC Input voltage range DC 13 28 V DC Rated input current Measuring circuit Monitoring function Measuring voltage Threshold value(s) at rated sense load and 24 V DC 1 W 120 ma undervoltage monitoring rated operational voltage 14 28 V Hysteresis related to the threshold value fix: 3 5 % Accuracy / Tolerance Maximum measuring cycle Indication of operational states 10 % of full scale value 6 ms Status of input 1 IN 1: green LED V: voltage at input 1 > than threshold 1 = no faults existing Status of input 2 IN 2: green LED V: voltage at input 2 > than threshold 2 = no faults existing Status of output OUT: green LED V: U out > 3 V = no faults existing Output circuits Kind of output 11 12/14 relay, 1 c/o (SPDT) contact Contact material Operating principle Rated operational voltage U e (IEC/EN 60947 1, VDE 0110) Minimum switching voltage / Minimum switching current Maximum switching voltage / Maximum switching current 21 22/24 relay, 1 c/o (SPDT) contact AgNi closed circuit principle 250 V 24 V / 10 ma 250 V / 1 A Rated operational current I e (IEC/EN 60947 1) AC12 (resistive) at 230 V 1 A AC15 (inductive) at 230 V 1 A DC12 (resistive) at 24 V DC13 (inductive) at 24 V 1 A 1 A Rating according UL 508 General purpose (GP) 250 V AC 1 A Maximum fuse rating to achieve short-circuit protection n/o contact n/c contact 2 A, gl 2 A, gl 4

Sense output (+, +, -) Sense output voltage Sense output current Maximum fuse rating 13-28 V DC 0.1 A for applications acc. UL the sense output shall be provided with a listed DC fuse 3 A General data Duty time 100 % Dimensions (W x H x D) when mounted Material of housing Weight Mounting position Mounting 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 inches) plastic 0.063 kg (0.14 lb) plugged onto redundancy unit CP A RU snap on mounting without any tool Degree of protection housing / terminals IP20 / IP20 Class of protection II Electrical connection all circuits Wire size Stripping length Tightening torque fine strand with wire end ferrule fine strand without wire end ferrule screw connection 0.2 2.5 mm 2 (24 14 AWG) 0.2 2.5 mm 2 (24 14 AWG) rigid 0.2 4 mm 2 (24 12 AWG) 7.5 mm (0.3 inches) 0.4 0.6 Nm Environmental data Ambient temperature range operation 25...+70 C storage 40...+85 C Damp heat (IEC/EN 60068 2 3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068 2 6) Shock (IEC/EN 60068 2 27) 93 % at +40 C, no condensation 3k3 Isolation data Rated isolation voltage U i (IEC/EN 60947 1, EN 50178, VDE 0160) Rated impulse withstand voltage U imp (type test) (IEC 664, VDE 0160) Power frequency withstand voltage test (Test voltage, routine test) Basic insulation all circuits all circuits 250 V 2.5 V 1.2 kv AC Protective separation (EN 50178) Input circuit / Output circuit yes Pollution degree (IEC/EN 60950) 2 Overvoltage category (IEC/EN 60950) 500 V II 5

Dimensions in mm 54 [2.13 ] 56,5 [2.22 ] 24 [0.94 ] 2CDC 272 016 F0b07 Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C02xx Power Supply Units Application manual 2CDC 114 048 M0201 Redundancy unit CP A RU 2CDC 114 036 D0202 You can find the documentation on the internet at www.abb.com/lowvoltage R Control Products R Power Supplies CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/partcommunity/portal/abb-control-products -> Low Voltage Products & Systems -> Control Products -> Power Supplies 6

Contact us STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 114 037 D0202 (10/12) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of AG. Copyright 2010 All rights reserved