1000W DUSK TO DAWN LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLDD1000 INSTRUCTIONS

Similar documents
5W LED Energy Saver PIR Bulkhead

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

OPERATING INSTRUCTIONS

PIR Motion Detector INSTALLER GUIDE E-806. SF-SA-360-CS-W.qxd 12/04/ :34 Page 1

PIR Motion Detector INSTALLER GUIDE E-700. SF-SA-140 -B.qxd 16/05/ :19 Page 1

PIR Motion Detector E-808

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Fused Spur Time Switch

60W Security Twinspot. 754HB2/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

Wireless 7 Day Programmable Room Thermostat

External Lighting Receiver

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

LED MOTION ACTIVATED FLOOD LIGHT

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

Xenon HID Lighting System

LED Security Spotlight User Manual

Awning Instructions. Full Cassette 1.5m to 6m

Triac Printed Circuit Board Replacement

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

EBDSPIR-PRM, EBDSPIR-PRM-IP

Wiper Motor Marinco 2.5. Installation Instructions

INFRARED QUARTZ WALL HEATER

Product and functional description

V94 BULK TAPE DEGAUSSER

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Operating instructions IV / 2007

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Contractors Guide Central Inverter System Installation

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

LED MOTION ACTIVATED FLOOD LIGHT

Atlanta CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Infrarot-Bewegungsmelder IP44

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

54 LinkTM. Instruction Manual. Includes our new CoolTouch Control System Looks permanent, but goes wherever you go! U.S.

LIEBERT VNSA Installation Sheet

EBDSPIR-DD, EBDSPIR-DD-IP

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Floodlight Range Installation Guide

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

User's Instructions. Alpha HE CB25/33 and HE SY25

WIRELESS HOME ALARM SYSTEM (WHA1)

Dome Security Camera with IR night vision

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

LOS 2500 SUPER CEILING SENSOR. Installation Manual

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

INSTALLATION INSTRUCTIONS

LED WATERPROOF TUBE LIGHT SPECIFICATION

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

How To Read A Pipe From A Sensor

Bubble King. User Manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE

Operating Instructions. Room temperature controller

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Security Camera Indoor/Outdoor Color Camera w/ Night Vision

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Cooktop Low-Profile Ventilation Hoods

KNX L. Brightness Sensor. Installation and Adjustment. Item number 70119

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Installation instructions, accessories. Cruise control. Volvo Car Corporation Gothenburg, Sweden. Instruction No Version Part. No

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Model 2300DR Installation Guide

6 LED colours: White Blue Green Red Yellow Amber

Drayton Digistat +2RF/+3RF

Secure Keypads for access control

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

Section G TEL-E-FOUL

Please also see 10 golden rules for correct Saniflo installation on

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

TREX OUTDOOR LIGHTING TROUBLESHOOTING GUIDE

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Chevelle Chevelle. (500645) Gauge Cluster Kit Installation Instructions. (500645) Gauge Cluster Kit Installation Instructions

Acano solution. Acano Solution Installation Guide. Acano. January B

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Section G TEL-E-FOUL

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

KNX R. Rain Sensor. Installation and Adjustment

Transcription:

1000W DUSK TO DAWN LIGHT CONTROLLER Cat No. SLDD1000 INSTALLATION & OPERATING INSTRUCTIONS

Introduction The SLDD1000 features an integral daylight sensing photocell which will automatically switch connected lights on at dusk and off at dawn. It incorporates an adjustable operation delay to prevent mis-operation due to e.g. car headlamps. A C LED Insert screwdriver and twist Common 1 Front cover hinges upwards Cable clamp Mains in Cable clamp fixing screws x 2 Output B Top

D Lux Time delay View on underside of unit shows adjustments. 2 Parts included Photocell (Dusk/Dawn) Switch. Instruction manual. Please keep safe for future reference. Accessory Pack. Tools and parts needed 3 core cable Electric/hand-held drill & bits. Terminal or Electricians screwdriver Wire cutters Unit can be used indoors or outdoors, but is specifically designed for outdoor use. Do not attempt to install during wet weather, if you are suffering from nausea or dizzy spells or if you are taking any medication with similar side effects. Do not attempt to install during wet weather, if you are suffering from nausea or dizzy spells or if you are taking any medication with similar side effects. If in any doubt, consult a qualified electrician.

Installation The unit is suitable for connection to a 240 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1sq.mm gauge is used. An internal switch should be installed to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for maintenance purposes. IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. 3 Open the unit by gently prying the ears on each side of the unit. See diagram A. This can be done without a tool, but if you prefer use a flat blade screwdriver, but be careful not to damage the clips. They should release easily. The front cover is hinged at the top, the front cover will swing open upwards. Using the unit as a template, drill the holes. Insert the wall plugs into the holes. See diagram B. It is recommended that the grommet is pierced with a screwdriver to ensure a better seal. Fix the unit to its mounting surface. Do not overtighten the mounting screws as this could damage the unit. If using a power screwdriver, use the lowest torque setting. Remove the cable clamp. See diagram C Pierce and pass the cables through the grommet. We recommend you use a screwdriver to pierce the grommet as this will give a better seal.

4 Connection Connect the incoming mains cable to the terminal block on the unit as follows (see connection diagram): NEUTRAL (Blue) N EARTH (Green/Yellow) LIVE (Brown) L Connect the lighting load cable to the terminal block. NEUTRAL (Blue) N EARTH (Green/Yellow) LIVE (Brown) L1 Please note the the N terminals are common. Ensure that the connections are secure. Re-attach the cable clamp and secure. Close the front cover. Installation is complete. Connection Diagram Mains in Isolation switch Testing Set the adjustment knobs as follows:- See diagram D. Dusk setting, fully anti-clockwise (daylight setting) Time Delay setting fully anti-clockwise (minimum 2 sec) The Dusk setting determines at which light level the switch will turn its connected load ON Turning this setting fully anti-clockwise allows you to test the circuit during daylight.

5 Connect the unit to the mains and switch power on. After a short delay, the unit will switch ON. This is indicated by the red LED see diagram C. Any attached lights will also illuminate. Setting up for automatic operation The DUSK (LUX) control determines the level of darkness required for the unit to start operating. The setting is best achieved by the procedure below: Set the Dusk and Time Delay control knob fully anticlockwise. Wait until darkness falls. When the ambient light level reaches the level of darkness at which you wish the lamps to become operative (ie. At dusk), SLOWLY (a small step at a time) rotate the control in a clockwise direction until a point is reached where the lamp illuminates. Leave the control set at this point. At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie. only when it is very dark), adjust the control slightly clockwise. Continue to adjust until the unit operates as desired. The Time Delay setting allows the user to determine at which time after the required darkness level is reached the lights will illuminate. This is beneficial in areas where intermittent light/darkness exposure is possible ie:- car headlights, or shadows. Turning the adjustment knob fully anticlockwise will illuminate the lamps 2 seconds after the lower lux level is reached. Turning the adjustment knob fully clockwise will illuminate the lamps 5 minutes after the lower lux level is reached. This will eliminate possible on/off switching due to intermittent light/darkness exposure.

Technical specifications Power Supply: Maximum Switching capacity: 230 V AC ~ 50Hz Filament/incandescent 1000W Fluorescent 250W (iron ballast only), not suitable for electronic high frequency ballast units including low energy/compact fluorescent lamps) Not suitable for discharge lighting 6 Operation: Environmental Protection: Conforms to Directives: Dusk - Dawn (adjustable daylight sensing) IP44 (suitable for outdoor use) 73/23/EEC and 89/336/EEC Troubleshooting guide Problem The sensor will not operate at night. Solution The level of ambient light in the area may be too bright to allow operation at the current DUSK setting. During the hours of darkness first turn the Time Delay knob to minimum then adjust the DUSK control slowly clockwise until the lamp illuminates. Refer to previous section for more details. Unit activates during the daytime. Adjust the setting anti-clockwise to lower the level of ambient light required for activation.

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. THREE YEAR 3 GUARANTEE HELPLINE 020-8450-0515 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND 020-8452-1112 or email csc@timeguard.com