Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Divadlo Inspirace (Ints-per-ats-zay)

Contacts. The Space. Lx Kit List. Sound Kit List. Stage Management. Health & Safety Policy

TECHNICAL SPECIFICATIONS.

Technical Specifications Lyric Theatre Belfast Danske Bank Stage

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER CAPACITY. Stalls: 257 Seats per row: 22(Max)

CORONET LONDON / Technical Information Pack (Updated - 1 st January 2015)

The Civic Hall in Bedworth Technical Specification

CIRCUS INCOGNITUS. Technical Rider Version: April 15, 2008

THEATRE USER INFORMATION GUIDE

SHUBERT THEATER 247 College Street, New Haven, CT

J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO THEATRE TECHNICAL INFORMATION MARCH 29, 2013

PRODUCTION SPECIFICATIONS

Théâtre de Suresnes JEAN VILAR presents RAYAHZONE

The theatre cafeteria can provide snacks during the morning and coffee in the afternoon for 500 persons.

TECHNICAL RIDER

Theatre Manager: Linda Aitken (03) ,

UCLA Department of World Arts and Cultures Glorya Kaufman Dance Theater (Room 200) Technical Information

Schouwburg & Filmtheater Agnietenhof Venue: 4000 AN Tiel. info@agnietenhof.nl techniek@agnietenhof.nl

FOOTHILL COLLEGE FINE ARTS FACILITIES OFFICE

Stadsschouwburg Amsterdam Rabozaal website technical rider - 13th of may 2011

Broadway Theatre refurbishment

TECHNICAL SPECIFICATIONS Paramount website: Paramount

Bradford Odeon. Tim Ronalds Architects

Les Docks / Av. de Sévelin Lausanne! Technical Rider

Artist: Michael and Amy Rider: Corporate - Grand Pianos

Brochure Event Production Suppliers Office Contact Sub Audio 2014

Theaters Tilburg - Concertzaal. Address

Adress: Teatertorvet DK Horsens Denmark. Postal adress: P.O.Box DK 8700 Horsens. Phonenr, etc..

The Swingle Singers RIDER PART 1: TECHNICAL REQUIREMENTS A Cappella Show

STAGE SPECIFICATIONS. Newberry Opera House

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

Meydenbauer Center Audio Visual Services & Price Guide. Provided by Audio Visual Factory Inc.

PA and Lighting Packages - Ready to Go

Production Services Department

Technical Specifications Version

TECHNICAL RIDER HULK

Traktor Audio Configuration

TECHNICAL SPECIFICATIONS

TECHNICAL INFOS CAPACITY 2 STAGE 2 TECHNICAL ROOF GRID (NOT YET AVAILABLE) 2 STAGE CURTAINS 3 FOLLOWSPOTS PLATFORM 3 ELECTRIC INSTALLATIONS 3

Our philosophy is grounded in supporting and nurturing a sustainable and modular creative environment and arts community.

L ORATORIO D AURELIA. Technical Rider. Administration: Didier Bendel Cell phone:(0049) (0) didierbendel@gmx.

TheatreNI Captioning Service Guide Contents

Douglas J. Cardinal Performing Arts Centre. Information and Technical Specifications

Watford s Major Entertainment and Hospitality Venue

Cole 100 Auditorium. Equipment Use Instructional Guide

Rental Policy & Pricing 2013

CUA50413 Diploma of Live Production and Technical Services

93 Caswell Avenue 1 Church Street Fax: opera.haskell@gmail.com website:

CONTACTS: * Alejandra Gómez [Management] alejandra@biche.com.co (+57) * Julián Salazar [Director] infomitu@gmail.com (+57)

Guidelines for Display Rules & Regulations

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

MEETING PACKAGES 400 LEVEL

Booking Procedure TERMS AND CONDITIONS

Conferencing, Room Hire and Events. Ticket Office

The Theatre Dictionary

LETTINGS POLICY. Claverham Community College. Adopted by the Governing Body on. Date. Signed

Access Statement Atlantic Tower Liverpool ( )

Exhibitor Guidelines for Booth Display Rules and Regulations

CONTACT INFORMATION. TICKET OFFICE Trevor Mangion, Ticket Operations Manager T: E:

Service Charges & Price List 2014

FREEMAN LABOR JURISDICTIONS

Theatre Hire Terms and Conditions of Use and General Information

Hotel accessibility pack

Section 6. Off-street Bicycle Space Regulations

Event Planner/Venue Specialist Phone:

Ellesmere Port Civic Hall Conferencing

City of Belmont Contractor Induction Program

Responsible For : Supervising students, temporary /casual and event staff

HC VEHICLE Local Government (Miscellaneous Provisions) Act 1976 The Town Police Clauses Act 1847

Signage Guide. for. Hearing Augmentation Systems

BRUXELLES ROOM. Total seats capacity 30. Total standing capacity. Total available seats / available armchairs. Hall qualitative level

Perth Concert Hall. Technical and Production Information

Theaters Tilburg - Concertzaal. Address

Banquet/Meeting Room Rental Agreement

Part 4 - Booking Form. Science Park MICE Venues / Open Spaces Booking

Conference Room Environmental Conditions :

SPACE AGREEMENT - (ENSEMBLE) - MCL Chicago USE OF SPACE AGREEMENT FOR MCL CHICAGO

SURROUND MASTER. User Manual 1.0. English. Copyright 2012 Involve Audio

Theater One (Upper level)

Technical & Production information. Updated

The Parkdale Yacht Club (PYC) may at its discretion refuse to accept any application for hire of PYC Hall.

Special Events & Space Rentals

SERVICING AND SPARES FOR YOUR SEATING

A/V and Video Conference Standards for Teaching and Learning Rooms.

make a model Roman Villa Supported by bbc.co.uk/history

Spreckels Theatre Theatre Rental Information

Blair School of Music

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

technical rider & Stage plan

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

Fire Safety Requirements for Child Care Centre

Noosa Jazz Festival Terms and Conditions Food and Market Stalls

CAIRNS CRUISE LINER TERMINAL VENUE HIRE DEED

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

Technical Requirements for Zoe Juniper

A laundry with washer, dryer, deep sink, sewing machine, full length mirror, steamer, and ironing equipment is also available.

PRODUCTION SPECIFICATIONS THE MANÈGE (RIDEHUSET)

ACCESSIBILITY STANDARD

Transcription:

Version 2015 By Carl Murray Bradford Playhouse Technical Rider

The Bradford Playhouse is a versatile theatre and performance space dating from the 1930 s.there are 5 performance spaces available in the venue with varying degrees of technical equipment/support. The performance spaces are: - The auditorium is a 265 seater proscenium arch traditional theatre space with counterweight flying. - The Isherwood studio space is a flexible black box space with movable seating and a maximum capacity of 70 and a standard capacity of 40. - The bar has a maximum capacity of 200. The simple regular performance space comfortably seats 50/60. - The Sewing Room Bar and our Room at the Top are blank canvases that people can very much make their own. We would like all visiting companies to have a safe and successful visit to The New Bradford Playhouse. This technical rider provides guidance to what is available within the building but is not intended to be a comprehensive guide to every situation. We expect all companies to understand and comply with all current health and safety legislation including the health and safety at work act 1974 and the licencing act 2003. Please ensure you have read all the information in this document before visiting the New Bradford Playhouse. There is a form at the end of the document for companies to sign to confirm they have read the information in this document. Please sign this form and return it at least 4 weeks prior to the start of your event. If you are considering any actions which would result in your undertaking a risk assessment please discuss the details with one of our team at least 4 week prior to your event. If you are not sure about any of the information contained in this document please ask. We would much rather have a conversation and ensure your event can take place safely.

Useful Contacts Company Manager Megan Murray 01274 800416/07542950590 Email megan@bradfordplayhouse.org.uk Artistic Director Jono Gadsby 01274 800415 Email jono@bradfordplayhouse.org.uk Technical Manager & Artistic Director (Studio@) Carl Murray 01274 800416 Email carl@studioat.co.uk Manager Clare Gadsby - 01274 800415 Email clare@bradfordplayhouse.org.uk

Technical Equipment All equipment was available at the time of writing this rider and all efforts will be made to ensure that equipment is maintained and where appropriate swiftly repaired. However, it may be the case that some equipment will be unavailable/in the process of being repaired at the time of your event. If there are any equipment items which you deem essential for your performance please contact us at least 2 weeks prior to your event. 1. The Get In Important, especially for the auditorium 1.1 The get in to the auditorium is extremely tight. The corridors to the main auditorium are the main access point. The larger staircase has two left turns in quick succession which then narrows to a gap only 1.00m wide by 1.95m tall. 1.2 There is a second access point available to the auditorium. This is accessed through the workshop under the stage and access is then through a trap door stage right. The dimensions of this access space are 2.10m long by 0.36m wide. Any set/equipment coming through this gap will have to be manually lifted into the auditorium. 1.3 It is recommended that any set intended to be used in the auditorium is able to be flat packed. 1.4 Access to Studio@, Sewing Room Bar and Room at the Top is also limited to any items that can pass through a standard doorway. 1.5 Access to the bar is similarly limited. 1.6 There is no lift access to any of the spaces and access to all spaces involves stairs. We recommend that if your event is reliant on significant set and/or equipment that you consider allowing additional time for your get in/get out and/or have additional technical crew available.

2. The Main Auditorium 2.1. Lighting Equipment Included In Hire NB. Lighting stock is shared with the Auditorium, Studio and Bar. Please specify what you require in advance. Strand LBX 300 Lighting Desk 72 ch * 2.5kw Strand LD90 Dimming 12 * 1.2kw Strand Cantata 18/32 Profiles 10 * 1.2kw Strand Cantata 26/44 Profiles 6 * 650w Strand Prelude 28/40 Profiles 1 * 650w Strand Prelude 16/30 Profile 12 * 1.2kw Strand Cantata Fresnell 10 * Strand Patt 137 Junior Flood 6* PAR64 Par Can 2 * Source 4 Juniors 650w 4 * 500w Strand minuette F 2.2. Sound Equipment Included In Hire Sound Desk Currently TBC AUX PDA500 Induction Loop JBL Digital System Controller for Stalls / Circle Speakers 8 x 2Ch Amps patchable for surround sound / standard setup Sony MXD-D40 CD/MD Player 3 x JBL Stage Speakers (Moveable) 4 x Fixed JBL Speakers (2xStalls, 2xCircle) 10 x Fixed Surround Sound Cinema Speakers (Patchable) 1 x Surround Sound Subwoofer (Beneath Stage)

2.3. Flies Standard Configuration Items marked with * may be removed or rehung by prior arrangement. Dimensions of stage 1. House Tabs 2. Not usable 3. IWB 4. *Legs 5. Not Usable 6. Free 7. *Border 8. Tabs 9. Cinema Screen 10. *Border 11. IWB 12. *Legs 13. Free 14. *Speakers 15. Free 16. *Border 17. IWB 18. Free 19. Free 20. *Cyc Border House and Mid Tabs electrically operated open and close, and may be flown in and out. Movable Drapes 8 x Black Serge Legs 3 x Black Serge Borders Assorted gauzes and screens by arrangement.

2.4. Cinema Projection By Arrangement Only Flown electrically operated cinema screen. Full Screen Cinema Projector 2.5. Staging By Arrangement Only Assorted treads, staging blocks and gate leg rostra. 2.6. Cabaret Seating - Auditorium The first three rows of seats in the auditorium are movable to create cabaret seating. This does however take a crew of 4 approximately 2 hours to complete so 4 weeks notice is required if you would like cabaret seating. This will Cost approx. 200. NB. The seats are located in the stage right wing after being moved which significantly reduces the available wing space. 2.7. Comms Metro Audio CM2 Master Studio (Loop A Tech, Loop B Dressing Rooms 4 x Monitor (DR1, DR2, DR3, Tech Box) 3 x Cans Belt Pack & Headset + Stage Manager Set Additional Belt Packs and Headsets available for hire by prior arrangement. 3. Studio@ 3.1. Lighting Equipment Included In Hire Zero88 Elara 12/24 Channel Crossfade Desk 2 * Zero 88 Betapack - 12 ch Dig6 Dimming Max 1k/channel (manual desk) Lighting is shared between the Auditorium, Studio and Bar. As a general rule the studio has 6 * 650w fresnels, 4 * 500w fresnels 3 * parcan 64 and 2 * 650w spotlights provided for any events. Please specify your requirements in advance.

Sound Equipment Included In Hire Crest 1500 Powered Amp Eclipse CD Player 2 * EV SX 100+ 20w Speakers Small 6 channel desk 4. The Priestley Coffee Lounge and Bar 4.1. A sound system is available on request. 5. The Sewing Room Bar/ Room At The Top No included equipment supplied. 6. Equipment Available By Arrangement All available equipment is subject to availability. 6.1. Lighting Equipment A full range of equipment is available for hire at additional cost. Please discuss your requirements with our Technical team, which will result in a formal quote being issued within 10 working days.

6.2. Sound Equipment 1 x Shure SM58 Vocal Microphone 2 x Shure SM57 Instrument Microphone 1 x Sennheiser Handheld Radio Microphone (300 Series) 3 * Ultra DI 2 * Studiospares DI Boxes 7 * Microphone stands Various lengths and types of cable NB. The tech box for the main auditorium is sound proof. It is recommended for live sound you mix from the back of the stalls or circle. This will take additional time if you have not let us know in advance this is what you want to do. 6.3. Scenic and Staging Various canvas covered flats in 12 and 8 heights and widths from 1 to 6, including single and double door, and window flats available strictly by prior arrangement. At least 6 weeks notice is required for Companies wishing to use House scenic materials, and an additional charge will be levied. Design and build may be quoted on application. Various gate leg rostra, staging blocks and treads available by arrangement, quoted on application. 7. Spares and Consumables 7.1. Lighting Spares and Consumables Lamps for Venue stock lanterns will be provided free of charge. Please request replacements from the Duty Technician. Gel we hold a good stock or warm and cold gel. We have some colours which you are welcome to use however these are not a regular supply or restocked.

7.2. Flameproofing All scenery, decorations, borders, drapery, gauzes, cloths, curtains and similar decorative hangings must be made of material which is not readily inflammable, or of material which has been rendered and is maintained flame-retarded to the satisfaction of The Venue and the Licensing Authority. 8. Technical Cover Charging Technical cover is required in the Main Auditorium and Studio: Whilst the dimmers are up; Whilst rigging or working at height. Please be aware if your get in or out exceeds the five hours in your contract - extra technical time will be charged at 15 per hour. Technical cover may be required for events in other spaces at the discretion of the Venue. You will be advised when booking if technical cover is required in addition to the hire price. 9. Risk Assessments For any aspect of your show or set where trips, falls, burns or traps are likely to be caused or where injury might happen due to specialist equipment or procedures taking place a risk assessment needs to be carried out. Please use the proforma (appendix 1). This needs to be returned to the venue manager 4 weeks before performance. In the event of equipment, staging or procedures taking place that have not been risk assessed, our duty technician has the right to stop or change an element of your show. Every endeavour will be taken to safely assess and put in place safe control measures to make things happen. If you have any element of your show you are unsure about please ask. Our team have a great deal of experience making exciting things happen safely.

General Information and a couple of rules: The technicians provided by the New Bradford Playhouse are there to help your performance to happen and we will endeavour to do so. That said we do have a couple of definite rules again not a definitive list - and since we don t like to use the word no we thought we would let you know upfront what they are: - The Duty Technician has the right to stop any aspect of your show if they deem your actions to be unsafe and/or in breach of any Health and Safety legislation. They will only do this once all avenues have been explored to try and ensure that the action can be achieved safely. - Please let us know if you are going to fly people upside down, use fire, blow things up, sword fight etc. We want to make these things happen safely. - Please let us know if you are using strobe lighting or other flashing effects at least 4 weeks prior to your event so we can make sure we comply with all the legislation and have signage up. - Only trained staff can use the flying system in the auditorium especially when loading and unloading flying bars. - Please don t assume you can leave things at the end of your performance. We only have a limited amount of space. All set, props and wood you have cut up from our workshop must be removed from site. If items are left the cost of a skip hire will be applied to your show. Please talk to us if you would like ts to help to arrange this anyway. - Please ensure that all appropriate set and/or equipment is fireproofed. - We have a safety curtain in the auditorium which is 4.90m from the back wall and 1.58m from the end of the stage. This MUST be shown to the audience at some point either prior to the show or during an interval so please ensure that there is no solid set obstructing the safety curtain. - We have no parking on site. We really mean this! - Please don t consume alcohol back stage, we have a very reasonably priced bar for you to do this following your event. - We have neighbours who are close to us especially opposite the front door/main get in point. Please bear this in mind when either performing, or during your get in and get out. We retain the right to ensure you to keep your performance within reasonable parameters.

Confirmation of Understanding and Acceptance Declaration By a Company I, the undersigned do, acting for and on behalf of ***** COMPANY NAME ***** hereby confirm understanding and acceptance of the Bradford Playhouse Technical Rules, as communicated to me in Version 1 of the same. I agree, for and on behalf of ***** COMPANY NAME ***** to indemnify The Bradford Playhouse, against loss or damage, howsoever caused, and litigation arising from failure of the Company to act in accordance with the Bradford Playhouse Technical Rules. Signed:.. Print:.. Date: Please return to Carl Murray carl@studioat.co.uk Carl Murray, Bradford Playhouse, 4 Chapel St, Bradford, BD1 5DL.