Section 3.3. Built-up Metal Walls. Rail and bracket system. Liner tray system. Product: Earthwool FactoryClad Roll Bw01. Roll.

Similar documents
Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Rockwool Cladding Roll

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

Multi-layer Insulation Blanket for Roofs

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

PROFILED METAL ROOFING DESIGN GUIDE

The Pocket Guide To Insulation August 2013

Rockwool Flexi Insulation Application Guide

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

sound reduction systems for commercial, educational and industrial environments

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

Lightweight Partition Design for Residential and Commercial Buildings

Colorcoat Technical Paper Acoustic performance of pre-finished steel cladding systems

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Rev Code of Practice. SIP Technology.

FIREPROOF Panels Trimoterm

Composite Panel Firewall Systems

The Kingspan Insulation Price List 1 st January 2013

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

ProRox Slabs (formerly known as RW slabs)

Rooflighting and Glazing

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

PB301 July Lightweight Building Solutions. Bushfire Protection.

CONDENSATION IN REFRIDGERATED BUILDINGS

Guide to the safe installation of downlighters in dwellings

Timber Frame Walls Rethinking Construction

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

The Warm Edge for insulating glass

Construction details. Technical specifications

Module 3.7. Thermal bridging

Understanding BS EN 771-3: Aggregate concrete masonry units

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Windows are one of the most important components of a

FederalDemocratic RepublicofEthiopia

RPV - RP - RA air handling units

Steel-framed Walls. Insulation

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Underwriters Laboratories Testing Information

Wardle Storeys. Reducing Rain Noise on Profiled Metal Roofing Systems Using DEDPAN DS2020 RDV

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Tsawwassen BC Arena Before & After installation of the Low-E ceiling

Physically Crosslinked Foam Insulation

ETHICS. WP 7: Design Guidance on energy and thermal improvements for non-residential buildings

The Case for Cross Laminated Timber: Part 2

How To Certify The Scottsdale Construction System

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Prefabricated building PVC vertical sliding window

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE

SOUND INSULATION FOR GLAZED DOORS AND STANDARD DOORS

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

Continuous Insulation Using Polyiso Wall Sheathing

Roof Insulation Building. Energy. Environment friendly e-library

Fiberglas, Exterior Wall Thermal Insulation

Confort 26. Sliding Systems. Sapa Building System

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Linear thermal transmittance of the assembly of the glazing and the frame in windows

Including. Rubershield-Pro. Breather Membrane

Decree of the Ministry of the Environment on fire safety of ventilation systems

Chapter 2 Basis of design and materials

IMPACT DAMAGE RESISTANT WALL SYSTEMS

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Fire Resistant Systems

SCHOTT PYRANOVA Planline System

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

Master Panel 1000 W Wall

Residential Refurbishment. September ThermoShell Internal Wall Insulation System Design Guide

Light-Weight Panels. High quality panels.

Dubai Municipality Standard DMS 1: Part 5: 2004

Avoiding Air Barrier Pitfalls

Providing protection in construction

Mineral fibreglass insulation

AND MEMBRANES ROOFING UNDERLAYS.

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

SANDWICH PANEL FILLING MATERIALS

Internal wall insulation in existing housing

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

The BASA Guide to the ISO Classification of Sealants for Building Construction

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

Certification of construction products - Fire dampers. Certification Rules 032

Energy Company Obligation (ECO): Technical Monitoring Questions

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications

ETAG 016 SELF-SUPPORTING COMPOSITE LIGHTWEIGHT PANELS. (Part one : G E N E R A L)

Transcription:

Section Built-up Metal Walls Rail and bracket system Product: Earthwool FactoryClad Roll Bw01 system Product: Earthwool FactoryClad Roll Bw02

Built-up Metal Walls Built-up metal walls Built-up metal wall design Thermal insulation Built-up metal walls can be installed on all types of residential and non-residential buildings, although they are most commonly installed on non-residenial buildings such as offices, shops and warehouses. It is possible to achieve very high standards of thermal insulation using built-up metal walls, but due to the complex nature of heat flow through these systems (due to the way they are assembled) it is not possible to calculate U-values using the normal simplified methods. Knauf Insulation Technical Advice and Support Centre can calculate the specification of insulation needed to achieve specific U-values (including the effect of thermal bridging for simple rail and bracket systems) but normally one would consult the system manufacturer, which is also the case for standing seam systems. Air permeability The uncontrolled infiltration or air leakage from a building has a significant impact on its energy efficiency. With good detailing and workmanship during the construction phase it is possible to achieve very high standards of airtightness in built-up metal wall constructions. This will of course restrict uncontrolled infiltration or air leakage and improve the energy efficiency of the building. Part L of the Building Regulations requires a measurement of the air permeability to be included in the whole building calculations used for compliance. The Simplified Building Energy Model (SBEM) is used for non-residential buildings and the Standard Assessment Procedure (SAP) is used for residential buildings. Typical problem areas include the junction of building elements at window and door openings or penetrations through the system such as rooflights. Thermal bridging There are two categories of thermal bridging that occur in built-up metal walls, the repeating thermal bridges inherent in built-up space type systems and the non repeating thermal bridges that occur at junctions and openings in the construction. The effect of the repeating thermal bridges are taken account of and included in the U-value calculation for the wall. Non repeating thermal bridges such as those found at junctions and openings must be calculated separately and the associated heat losses included in the SBEM or SAP calculations. Heat loss through linear thermal bridges (known as the psi value) is accounted for by multiplying the length of each thermal bridge by its psi value. Acoustic performance Buildings with built-up metal walls may need to incorporate noise control measures not only to meet Building Regulation requirements, but also Health and Safety and Environmental Health Regulations as well as the building occupiers specific requirements. These measures can be grouped into two categories, sound insulation and sound absorption. Sound Insulation A poorly designed built-up metal wall can transmit a significant amount of sound, which will lead to the building failing to provide an acceptable level of protection either to the users or occupants of the building or to people living close to the building from noise generated within the construction envelope. One of the most effective methods of improving sound insulation is to increase the mass of the structure. Built-up metal walls are generally lightweight, however they are able to provide a high level of separation (between the internal and external metal sheets) and also include glass or rock mineral wool within the structure which provides very high levels of sound absorption. When the effects of separation and sound absorption are combined in a built-up metal wall it is possible to achieve outstanding levels of sound insulation. Health and Education requirements Building Regulations primarily impose a requirement on external walls in schools where it is a requirement that the building should meet the standards set out in Section 1 of Building Bulletin 93 The Acoustic Design of Schools. This sets specific upper limits for indoor ambient noise levels. Factors affecting the performance required by the walls will include noise from road, rail, air traffic and industrial and commercial premises. The acoustic performance required in other types of buildings may be controlled by government requirements such as hospitals under HTM 08-01 160 Technical Advice and Support Centre 01744 766666 www.knaufinsulation.co.uk

Built-up Metal Walls (previously HTM 2045), or specific client Fire protection It is a requirement of the Building Regulations that The spacer system used to support the outer requirements. Environmental Health Regulations may require specific sound insulation performance from external walls where high levels of internal noise are generated, such as industrial buildings and sports and concert halls to stop sound breaking out of the building and thus prevent noise nuisance to neighbours. Sound absorption The control of the indoor acoustic environment is important to maintain health and safety for workers and occupants of buildings. It is possible using perforated metal liner sheets containing a sound absorbing lining (usually glass or rock mineral wool) to control sound reverberation which would otherwise be problematic. Rain noise Acoustic performance has traditionally not featured high on the list of design priorities but guidance now states that it is essential that rain noise is considered in the design of built-up metal systems as it can significantly increase the indoor ambient noise level. Future intention is that rain noise will be considered within Building Bulletin 93. Until this time, it is appropriate for design teams to provide evidence to the building control body that the built-up metal system has been designed to minimise rain noise where required. external cladding elements shall resist the spread of fire from one building to another. The degree of fire resistance which the external roofing element must provide will depend upon the size and use of the building and it's distance from any boundary. Further performance information will be available from the cladding system manufacturer, whose built-up metal wall systems have the advantage of using non-combustible glass and rock mineral wool insulation. Control of condensation Surface condensation could potentially occur on the underside of the liner sheet if there were significant thermal bridges through the system, interstitial condensation could occur within the structure of the system if there was a significant break in the vapour control layer. Many proprietary systems have sealed joints and overlaps in the liner sheet in order to provide the vapour control layer or they contain a separate vapour control layer in the form of a polyethylene sheet which itself has sealed joints and overlaps. Where a perforated liner sheet is used then a separate vapour control layer should always be installed. cladding sheet contains a potential thermal bridge and thus could be a point for localised condensation on the liner sheet. However, modern built up metal systems include a significant thermal break pad underneath the support brackets as a necessity for the achievement of the specified U-value, and as such the chance of condensation occurring where the spacer system is fixed to the liner sheet is negligible. If there are significant gaps in the insulation layer then it may be possible for localised surface condensation to occur. The likelihood of either problem occurring is extremely low, however, extra care needs to be taken in buildings with high levels of humidity such as swimming pools or food processing plants. Solution optimiser and pathfinder Knauf Insulation solution U-values 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 Rail and bracket system Product: See page: 172 Bw01 system Product: See page: 174 Bw02 Key Thermal insulation achievable by constructions within this document. Pb01 Find online. Visit knaufinsulation.co.uk and key in construction code to find the most up to date information on your chosen solution. Technical Advice and Support Centre 01744 766666 www.knaufinsulation.co.uk 161

Built-up Metal Walls Built-up metal walls Rail and bracket system Interlocking nature of mineral wool ensures: Rolls knit together at joints ensuring no loss of thermal or acoustic performance Joints between rolls are closed, preventing air movement and infiltration through or around the insulation Lightweight cost effective solution Bw01 Liner sheet NEW BUILD REFURB Non-combustible with a Euroclass A1 reaction to fire rating Rail and bracket A+ Generic BRE Green Guide rating Zero Ozone Depletion Potential (ODP) Zero Global Warming Potential (GWP) Products is a range of flexible, lightweight, non-combustible, resilient glass mineral wool quilts. They are manufactured in long lengths and have exceptionally high tear strength, making them particularly suitable for use in the walls of profiled metal clad buildings. Typical construction Profiled metal external sheet, rail and bracket spacer system with thermal break, profiled metal liner and installed between the external metal profiled sheet and the inner liner sheet. is used for the thermal and acoustic insulation in profiled metal clad roofing systems. With a Euroclass A1 fire classification, its use can potentially reduce insurance premiums when compared to foam composite panels. is manufactured 1200mm wide and in long lengths, making it particularly suitable for use in profiled sheeting systems. Installation Following the erection of the building frame and sheeting rails, the internal profiled metal liner is fixed, together with the metal spacer system. Seals are applied as necessary to minimise air leakage. is installed against the liner panels and between the spacers, with all quilt edges tightly butted. With rail and bracket spacer systems, the rail holds the insulation tightly to the internal sheets. Profiled metal external sheets are fixed as soon as possible after the, to avoid exposure to the weather. Performance Thermal performance 32 has a thermal conductivity of 0.032 W/mK 37 has a thermal conductivity of 0.037 W/mK 40 has a thermal conductivity of 0.040 W/mK Knauf Insulation recommend that the system designer is contacted for specific U-value calculations. Fire is classified as Euroclass A1 to BS EN 13501-1 Vapour resistivity has a vapour resistivity of 5.00 MN.s.g.m. Acoustic performance Sound absorption: Achieved by perforating the metal liner sheet and incorporating a soft absorbing insulation material behind it. Different combinations of perforations and levels of insulation will give varying results of sound absorption. Airborne sound reduction: A standard insulated roof construction will have an approximate weighted sound reduction (Rw) of 33dB with an aluminium trapezoidal liner and 36dB with a steel trapezoidal liner. The acoustic performance can be increased by varying the number and the density of the insulation layers as well as adding additional mass into the construction. Rain impact noise and flanking sound: System manufacturers have achieved significant impact noise reductions through the use of mineral wool insulation. 162 Technical Advice and Support Centre 01744 766666 www.knaufinsulation.co.uk

Built-up Metal Walls Typical sections Vapour control layer Vapour control layer Proprietary Z or C section Proprietary Z or C section Table 15 - Typical U-values for a rail and bracket system Product Rails at 1.20 metre spacings Thickness (mm) U-value (W/m 2 K) 32 170 0.21 160 0.22 37 180 0.23 160 0.26 140 0.29 40 160 0.27 140 0.31 130 0.33 Typical specification 32*/37*/40* mm thick, to be positioned over the inner lining sheet and between the spacer system prior to positioning of the outer cladding sheet. Insulation to be installed according to the system manufacturer s installation instructions. Alternatively, consult the National Building Specifications, Standard version clause/clauses H31/50, 254 and 271 Knauf Insulation specification clauses can be downloaded from knaufinsulation.co.uk/nbs CERTIFICATE CS/1001-2 U Value Competency Scheme Notes: Generic rail and bracket U-value calculations can be provided by our Technical Advice and Support Centre, however, for proprietary rail and bracket systems and all standing seam systems, the system manufacturer should be consulted for project specific U-value calculations. Technical Advice and Support Centre 01744 766666 www.knaufinsulation.co.uk 163

Built-up Metal Walls Built-up metal walls system Interlocking nature of mineral wool ensures: Rolls knit together at joints ensuring no loss of thermal or acoustic performance Joints between rolls are closed, preventing air movement and infiltration through or around the insulation Lightweight cost effective solution Bw02 NEW BUILD Non-combustible Euroclass A1 reaction to fire rating A+ Generic BRE Green Guide rating Zero Ozone Depletion Potential (ODP) Zero Global Warming Potential (GWP) Products is a range of flexible, lightweight, non-combustible, resilient glass mineral wool quilts. They are manufactured in long lengths and have exceptionally high tear strength, making them particularly suitable for use in the walls of profiled metal clad buildings. Typical construction Profiled metal external sheets are fixed to the metal liner trays which incorporate a thermal break strip. is positioned within the troughs of the liner trays. An unventilated airspace of at least 25mm is maintained between the insulation and the external sheeting. Built-up metal walls and cladding systems are assembled on site and the design and components used are usually part of a proprietary system. Installation s are fixed horizontally to the structural steel members and sealed to minimise air leakage. is cut to size and installed in the liner trays, prior to fixing the external sheets. The profiled metal external sheets should be fixed as soon as possible after the has been installed, to avoid exposure to the weather. Performance Thermal performance is produced in three different thermal conductivities as follows: 32 has a thermal conductivity of 0.032 W/mK 37 has a thermal conductivity of 0.037 W/mK 40 has a thermal conductivity of 0.040 W/mK Knauf Insulation recommend that the system designer is contacted for specific U-value calculations. Fire performance is classified as Euroclass A1 to BS EN 13501-1 Vapour resistivity has a vapour resistivity of 5.00 MN.s.g.m. Acoustic performance Sound absorption: Achieved by perforating the metal liner sheet and incorporating a soft absorbing insulation material behind it. Different combinations of perforations and levels of insulation will give varying results of sound absorption. Airborne sound reduction: A standard insulated roof construction will have an approximate weighted sound reduction (Rw) of 33dB with an aluminium trapezoidal liner and 36dB with a steel trapezoidal liner. The acoustic performance can be increased by varying the number and the density of the insulation layers as well as adding additional mass into the construction. Rain impact noise and flanking: System manufacturers have achieved significant impact noise reductions through the use of mineral wool insulation. Environmental s manufacture has a low impact on the environment and is classified as Zero ODP and Zero GWP. 164 Technical Advice and Support Centre 01744 766666 www.knaufinsulation.co.uk

Built-up Metal Walls Typical sections Thermal break Stuctural steel support Thermal break Stuctural steel support Table 16 - Typical U-values for liner tray systems Product Thickness (mm) U-value (W/m 2 K) 32 170 (90+80) 0.21 160 (2x80) 0.22 37 180 0.23 160 0.26 140 0.29 40 160 0.27 140 0.31 130 0.33 Notes: The system manufacturer should be contacted for project specific U-value calculations. This U-value calculation table is outside the scope of the BBA/TIMSA Scheme for U-value Calculation Competency. Typical specification Wall liner trays: liner trays fixed horizontally to the vertical steel members Earthwool FactoryClad Roll 32*/37*/40* mm thick, placed in the liner trays. Insulation should be cut to accommodate the tray dimensions and positioned in the tray prior to fixing the outer cladding. Insulation to be installed according to the system manufacturer s instructions. Alternatively, consult the National Building Specifications, Standard version clause/clauses H31/50, 254 and 271 Knauf Insulation specification clauses can be downloaded from knaufinsulation.co.uk/nbs Technical Advice and Support Centre 01744 766666 www.knaufinsulation.co.uk 165

Knauf Insulation Ltd Customer Service (Sales) Technical Advice and Support Centre Literature PO Box 10 Tel: 0844 800 0135 Tel: 01744 766 666 Tel: 08700 668 660 Stafford Road Fax: 01744 612007 Fax: 01744 766 667 Fax: 0870 400 5797 St Helens Email: sales.uk@knaufinsulation.com Email: technical.uk@knaufinsulation.com Email: info.uk@knaufinsulation.com Merseyside www.knaufinsulation.co.uk WA10 3NS