401 DEADBOLT ELECTRIC DOOR CONTROLS

Similar documents
FOLGER ADAM PRODUCT CATALOG

PRODUCT INTRODUCTION PRECISION HARDWARE

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Decorative Lever Designs

280+ Mortise Mounted Series Shear Locks Special Application Solution

Door control and security hardware

Dor-O-Matic Exit Devices

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

INSTALLATION INSTRUCTIONS FOR MODEL 1560 AND 1570 ELECTRIC TRIM CONTROL FOR USE WITH CORBIN 955 AND YALE 626F HEAVY DUTY TRIM

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

EMF/EMR. Holder/Release Devices with Integral Door Closers

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

Basic Technical Fundamentals of Builders Hardware Mortise, Bored and Auxiliary Locks

Basic Technical Fundamentals of Builders Hardware

K17.11 DOOR BOLTS K17 DOORS

CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE

Technical Information

TS93 EMR T/PT/TDE. Surface applied door closer

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

SECTION 6. Glass Storefront Doors:

HARDWARE STANLEY ARCHITECTURAL HARDWARE

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

7200 series Electromechanical Closer/Holder

Life Safety, Security Door Hardware and Integrated Door Security Systems

Housing Fact Sheets. Protecting Your Home Against Theft

Floor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open DORMA BTS80 EMB

Cabinet Locks. Benefits:

Owner's Copy December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS

Architectural Hardware Design Guide High-performance hardware for the most demanding architectural applications

NEWSTAR BROCHURE. December 2007

Call for Availability

STANLEY DOOR CLOSERS D-4550/D-4551 D-4550 / D-4551 SERIES OOR CLOSERS

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Door Hardware Lock Specifications

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

ASSA HIGH SECURITY LOCKS ASSA Twin ASSA Twin 6000, Twin Exclusive & V10. ASSA cylinders can be supplied in the following keying forms:

Circuit Breakers. NRC Series. NRC Series

9300BC SERIES Light Commercial Door Closer

Harris County Fire Code Electronic Lock Procedures

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Key in Knob & Key in Lever

Electromagnetic locks

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

Master Code 2. Troubleshooting: Installation 7. Troubleshooting: Door Jamming and Door Handing 8. Troubleshooting: Keypad 12

Product Catalog Phone: Fax:

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Security Screen Door Hardware

Automatic Door Selection Guide

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

the Company will not warrant ANSI A156.2 Grade 2 lever Product installed in educational facilities and student housing.

Exit Devices TABLE OF CONTENTS

Sliding Door Locks & Hardware. 5 c

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Automatic Door Openers and ADA Devices Rev. 0 Bid # Scope of Work

Type NT and Type ZWM Terminal Blocks

Combi B Alarm box. Mounting instructions

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

ILCO Cylinders. Cams and Tailpieces. Keyways. Finish Codes. 1 Standard (863G) Composite NB HR1. Composite NA R1064E. 2 Adams Rite (863A) Arrow AA 1179

8900 EMR (WITH DETECTOR)

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

PROOF ONLY. Police and Fire Service Home Security & Fire Safety Checklist. Student Accommodation Security Checklist

Security Access Control 101

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Fire Pump Controllers Remote Alarm Panels

Wood Sound Retardant Door Hardware Information Bulletin

No Phone Line II-48 System

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Plastic Injection Molding

HES & Folger Adam Electric Strikes & Accessories CANADIAN PRICELIST. Effective Date: Apirl 4, 2016

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

Universal MATE-N-LOK Connectors

Combination & Screen Doors

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

B. Division 16 Basic Materials and Methods sections apply to work of this section.

YALE DIGITAL DEADBOLT

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Understanding Access Control

Lock Function Chart Page 1 of 7

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Palm Beach County Sheriff s Office

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Reachout Lock Replacement for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors

PDQ HINGE SUGGESTED ARCHITECTURAL SPECIFICATIONS METICULOUSLY MANUFACTURED, THE PDQ HINGE IS AVAILABLE IN 3 BASE METALS: SPECIFICATIONS HINGE SERIES

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Troubleshooting: Door Jamming and Door Handing 6. Troubleshooting: Keypad 11. Troubleshooting: Battery 12. Battery FAQ 13

ABLOY EL420, EL520 Europrofile motor locks

PHA 2000 PHB 3000 EXIT PAD

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

Transcription:

401 DEADBOLT

401 ELECTRIC DEADBOLT APPLICATION For use with swinging, sliding, power operated and vertical lift doors. Model 401 (Fail Safe) Locks When Energized unlocks automatically in case of power failure. Under normal operation, deadbolt extends when door is closed and control switch is in "lock" position. Model 401R (Non-Fail Safe) Unlocks When Energized locks automatically in case of power failure. Under normal operation, deadbolt extends when door is closed and control switch is in "lock" position. PRODUCT FEATURES Compact, Heavy-Duty Construction. Solenoid Actuated Power surge, continuous-duty solenoid. Tapered Deadbolt Helps locate hole in keeper that may be slightly misaligned. Door-Position Switch (DPS) An internal switch to ensure that the deadbolt extends only when door is closed. Deadlocks Automatically when door is closed. Listed by Underwriters' Laboratories, Inc. Burglary Resistant Electric Deadbolt. (UL Standard No. 1034, Burglary-Resistant Electric Locking Mechanisms.) Mortise Mounting. Non-Handed Reversible. Operates in any position. Housing Size 4-1/2" H x 9" L x 1-3/4" W designed to accomodate all optional features. (See optional features for smaller size housing.) Supplied with Mortise Keeper, wiring diagram and mounting screws. OPERATING VOLTAGES Voltage: 24 VDC, 6.25 amps inrush, 0.42 amps seated. Solenoid Voltage: 120 VAC or VDC (optional). Note: Junction box is supplied with 120V deadbolts (to comply with UL requirements). Indlcatlon Swltches: Single pole, double-throw type (SPDT). Ratings: 10 amps @ 125 or 250 VAC. (Optional only.) Note: All deadbolts are actuated by DC solenoids. When primary power source is AC, the deadbolt is supplied with an internal bridge rectifier. FINISH BHMA US Description 606 US4 Satin brass, standard 612 US10 Satin bronze, clear coated 613 US10B Oxidized satin bronze, oil rubbed 625 US26 Bright chromium plated 626 US26D Satin chromium plated Page 130

401 ELECTRIC DEADBOLT OPTIONAL FEATURES Indlcatlon Swltches Internal switch(es) to monitor the positions of the deadbolt. This feature can be used for remote door monitoring, to control alarms, indicating lights, interlocks and automatic door operators. One or two switches can be supplied, depending on circuit requirements. Specify switch options by letters: BL a switch that indicates when the deadbolt is fully extended. BUL a switch that indicates when the deadbolt is fully retracted. NOTE: When door is open, the door-position switch tripper can be manually depressed, thereby giving a false indication that the door is locked. This can be eliminated if desired by installing a door-position indication switch and wiring it in series with the indication switch(es) in the deadbolt. Then a secure signal can be produced only after three conditions have been met: 1) door-position switch tripper is depressed 2) deadbolt is extended and deadlocked, and 3) door is closed. Housing Size A smaller size housing is available, 3-3/4" H x 9" L x 1-3/4" W, but accomodates only the Fail Safe unit (Model 401). Accessories Available Mounting Tabs; Rim Mounting (see page 134); Fence Gate Mounting (see page 135). Manual Release The deadbolt may be modified for overriding the electric operation, allowing for manual unlocking from one side only. Specify "MR". This feature may be adapted by the customer for a customized unlocking system, or by the following, factory-supplied accessory items, which must be purchased separately (see pages 136-138 for options): Detention or commercial key cylinders (by others). Rim-Type Key Cylinder may be used for manual unlocking of the deadbolt, in conjunction with the appropriate holder (see pages 137-138). Key Cylinder Holders Holds and protects the key cylinder used for manual unlocking. They are available in three styles, depending on where the holder is located: Hinge For the hinge side of a door frame, when the 401 Electric Deadbolt is mortised into either the door header or jamb. Stop For the stop side of a door frame, when the 401 Electric Deadbolt is mortised into either the door header or jamb. Rim For mounting to the surface of either a rim housing (401-RM) or fence-gate housing (401-118). Page 131

401D ELECTRIC DEADBOLT APPLICATION For use with swinging, sliding, power operated and vertical lift doors. Model 401D (Fail Safe) Locks and Unlocks When Energized unlocks automatically in case of power failure. Under normal operation, deadbolt extends when door is closed and control switch is in "lock" position. Model 401DR (Non-Fail Safe) Locks and Unlocks When Energized locks automatically in case of power failure. Under normal operation, deadbolt extends when door is closed and control switch is in "lock" position. PRODUCT FEATURES Compact, Heavy-Duty Constructlon. Solenold Actuated Two, power-surge, continuous-duty solenoids. (Requires a two-position control switch.) Tapered Deadbolt Helps locate hole in keeper that may be slightly misaligned. Door-Position Switch (DPS) An internal switch to ensure that the deadbolt extends only when door is closed. Deadlocks Automatically when door is closed. Listed by Underwriters' Laboratories, Inc. Burglary Resistant Electric Deadbolt. (UL Standard No. 1034, Burglary-Resistant Electric Locking Mechanisms.) Mortise Mounting. Non-Handed Reversible. Operates in any position. Housing Size 4-1/2" H x 9" L x 1-3/4" W designed to accomodate all optional features. Supplied with Mortise Keeper, wiring diagram and mounting screws. OPERATING VOLTAGES Voltage: 24 VDC, 6.25 amps inrush, 0.42 amps seated. Solenoid Voltage: 120 VAC or VDC (optional). Note: Junction box is supplied with 120V deadbolts (to comply with UL requirements). Indlcatlon Swltches: Single pole, double-throw type (SPDT). Ratings: 10 amps @ 125 or 250 VAC. (Optional only.) Note: All deadbolts are actuated by DC solenoids. When primary power source is AC, the deadbolt is supplied with an internal bridge rectifier. FINISH BHMA US Description 606 US4 Satin brass, standard 612 US10 Satin bronze, clear coated 613 US10B Oxidized satin bronze, oil rubbed 625 US26 Bright chromium plated 626 US26D Satin chromium plated Page 132

401D ELECTRIC DEADBOLT OPTIONAL FEATURES Indlcatlon Swltches Internal switch(es) to monitor the positions of the deadbolt. This feature can be used for remote door monitoring, to control alarms, indicating lights, interlocks and automatic door operators. One or two switches can be supplied, depending on circuit requirements. Specify switch options by letters: BL a switch that indicates when the deadbolt is fully extended. BUL a switch that indicates when the deadbolt is fully retracted. NOTE: When door is open, the door-position switch tripper can be manually depressed, thereby giving a false indication that the door is locked. This can be eliminated if desired by installing a door-position indication switch and wiring it in series with the indication switch(es) in the deadbolt. Then a secure signal can be produced only after three conditions have been met: 1) door-position switch tripper is depressed 2) deadbolt is extended and deadlocked, and 3) door is closed. Housing Size A smaller size housing is available, 3-3/4" H x 9" L x 1-3/4" W, but accomodates only the Fail Safe unit (Model 401). Accessories Available Mounting Tabs; Rim Mounting (see page 134); Fence Gate Mounting (see page 135). Manual Release The deadbolt may be modified for overriding the electric operation, allowing for manual unlocking from one side only. Specify "MR". This feature may be adapted by the customer for a customized unlocking system, or by the following, factory-supplied accessory items, which must be purchased separately (see pages 136-138 for options): Detention or commercial key cylinders (by others) Rim-Type Key Cylinder may be used for manual unlocking of the deadbolt, in conjunction with the appropriate holder (see pages 137-138). Key Cylinder Holders Holds and protects the key cylinder used for manual unlocking. They are available in three styles, depending on where the holder is located: Hinge For the hinge side of a door frame, when the 401 Electric Deadbolt is mortised into either the door header or jamb. Stop For the stop side of a door frame, when the 401 Electric Deadbolt is mortised into either the door header or jamb. Rim For mounting to the surface of either a rim housing (401-RM) or fence-gate housing (401-118). Page 133

401-RM RIM HOUSING APPLICATION For use when rim-mounting the 401 Electric Deadbolt. 401-RM RIM HOUSING A two-piece housing which encases a 401 Deadbolt for mounting on the surface of a door frame. The housing and cover are made of 10-gauge, cold-rolled steel and have a primed finish. The 401 Deadbolt must be purchased separately. Manual Release Key operation which overrides other controls (see pages 136-138). 401-125 DOUBLE-SIZE RIM HOUSING To accommodate two 401 Deadbolts for mounting over double doors. 401-90 ADJUSTABLE RIM KEEPER Must be purchased separately. It is adjustable from 1" to 2", from centerline of bolt to face of door. If more than 2" is required, a 2" to 3" adjustable rim keeper is available. Special keepers for larger reveals are also available. These steel keepers have a primed finish. STANDARD FINISH Standard finish, US prime. OPTIONAL FINISHES BHMA US Description 612 US10 Satin bronze, clear coated 613 US10B Oxidized satin bronze, oil rubbed 625 US26 Bright chromium plated 626 US26D Satin chromium plated Page 134