Power & Energy Monitoring in the Era of Green Energy

Similar documents
Metering for today s systems

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Titelgrau belassen! Leere Vorlage

Business Energy Efficiency. Webinar August 29, 2012

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

Electricity Terminology. Simplifying energy management

FIXED CHARGE: This is a cost that goes towards making the service available, including

Substation Automation and Smart Grid

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

Topic 2: Introduction to Smart Grid

scalable data centre energy management solution

Three phase circuits

Net Metering Summary Within Northeast Utilities

Power Meter Series 700

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

Fundamentals of Power

21 st Century Facilities

VOLTAGE REGULATOR AND PARALLEL OPERATION

Renewable Choice Energy

Deep Dive on Microgrid Technologies

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

Energy Cost Reduction through Load Balancing & Load Shedding

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

factor max Delivering Electrical Efficiency INFORMATION PACK factor max

Current Transformers

Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation

SUSTAINABLE TECHNOLOGY

Electricity Meter in the age of Photovoltaic

Power Electronics Testings

UNDERSTANDING ENERGY BILLS & TARRIFS

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Creating a Resilient Energy Network of Net Zero Buildings

AC Power. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department

Tamura Closed Loop Hall Effect Current Sensors

Table of Contents. TransformerIQ FAQs 1

Comparison of Recent Trends in Sustainable Energy Development in Japan, U.K., Germany and France

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

March 15th 2005 EI Solutions - Submetering 1

GSM ATT Modules Simply effective remote control

Smart Cities Smart Streetlights Panel Discussion. September 23, 2014

UPS Applications and VRLA Battery Sizing

TITLE PAGE MINNESOTA POWER ELECTRIC RATE BOOK

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

UTILITY RATE STRUCTURE

Agenda. Part I: Introduction to OptimumHVAC. Part II: Initial Energy Savings Analysis for MCO Main Terminal. Part III: Case Studies & Conclusion

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

ADMS(Advanced Distribution Management System ) in Smart Grid

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Process and Energy Audits at Water and Wastewater Facilities. Thomas Devine, CAP, CEM, LEED AP April

Applications. diris_826_a_1_gb_cat

Starting Current Reduction of Residential HVAC System and Peak-Load Impact of Power System: A Case Study

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

EssPro Energy Storage Grid Substation The power to control energy

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

White Paper: Pervasive Power: Integrated Energy Storage for POL Delivery

415V DISTRIBUTION FOR GREEN DATA CENTERS

Florida Department of Education Student Performance Standards

Green Energy Solutions

Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17

Control of a Hybrid Energy System

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

415V DISTRIBUTION FOR GREEN DATA CENTERS

Inverter technology. bulletin

TESLA Recorder Power Metering Setup Configuration for 3 and 2 Element Watt/VAR Metering

Foreseer Services. Product application guide. Table of contents

Guideline for Energy Efficient Electrical systems for building. Presentation by TERI

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

Power factor correction. An introduction to technology and techniques

How To Get A Better Deal On Power From Powerline Power From Pse

Reliability and security of electricity supply: the Italian blackout

Power Quality. Uninterruptible Power Supply

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

SAGEON SITE MONITOR (SSM) Application Note AN

Eaton s E-Series protective relay family

Multiple sources of energy will be available, giving the consumer choices. A Higher Percentage of Energy will come from renewable energy sources

3-Phase AC Calculations Revisited

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

FIT TIER 2 Application

Smart Grid Enabling a Sustainable Energy Future

Wireless Networks and Power Quality

KACO-monitoring. watchdog prolog insight sunwatch. Easy to install. Inverter integrated monitoring available

Application Information Improving Efficiency in Smart Grid Applications With Fully Integrated Current Sensing ICs

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Step Voltage Regulators

Definition AC Power Distribution

Multilin EPM GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.

Dakota Energy Cooperative, Inc. POLICY STATEMENT

BCSE Briefing: Driving US Economic Growth and Jobs. Chris Perrault, Vice President January 26, 2011

NC-12 Modbus Application

Energy Audits Waste Water Treatment Plants

KACO-monitoring. watchdog prolog insight. Easy to install. Inverter integrated monitoring available. Monitor up to 32 inverters with one device

ABSTRACT DCMCCT PROJECT OVERVIEW

Transcription:

Power & Energy Monitoring in the Era of Green Energy Weschler Instruments IRIS2009.ppt 1

Agenda Energy Trends Consumer Load Monitoring Commercial & Industrial Applications Industrial Products Test Equipment 2

Distributed Generation Solar Wind Geothermal Hydroelectric Energy Trends 3

Off-Grid Operation Mobile Applications Temporary Applications Isolated Sites Innovators Energy Trends 4

Smart Meters Automated Reading (AMR) Outage Notification Real Time Load Monitoring Variable Rate Billing Remote Load Shedding Energy Trends 5

Time of Day Rates Reduce Demand Peaks Defer Power Plant Construction Better Utilize Existing Transmission Lines Encourage Conservation Energy Trends 6

Real Time Load Management By Utility or Customer Prevent Overloads, Brownouts & Blackouts Avoid Power Plant Construction Defer New Transmission Lines Energy Trends 7

Cogeneration Combined Heat & Power Supply Local Electrical Need Sell Excess Power to Utility Standby Power Energy Trends 8

Higher Energy Costs Fuel Prices Emission Controls Delivery Fees Carbon Tax Escalating Rate Brackets Energy Trends 9

Mandatory Conservation Energy Independence & Security Act (2007) Executive Order 13423 (2007) Energy Policy Act of 2005 DOD Instruction 4170.11 (2005) LEED Certification (Green Building Initiative) Utility Demand Response programs Energy Trends 10

Energy Trends Distributed Generation Off-Grid Operation Smart Meters Variable (Time of Day) Rates Remote Load Management Higher Energy Costs Mandatory Conservation Goal Conserve energy & reduce fossil fuel use Where & How Much Need to Measure 11

Key Terms Active Power Apparent Power Reactive Power Power Factor Active Energy Demand (kw) Fundamental Harmonic Order W = VA (DC source) W = VA PF (AC source) S = VA Q = VAr PF = W/VA λ kwh Average power for time interval Mains frequency Multiple of mains frequency 12

Waveforms Motor Load Switching Power Supply 13

Power Measurement ICs RMS Voltage, RMS Current Line Frequency Neutral Line Current Power Factor(s) Voltage Phase Angles Active/Reactive/Apparent Power Active/Reactive/Apparent Energy Fundamental/Harmonic Power Bi-Directional 14

Load Monitoring Consumer Products Single Device Entire House Web Enabled 15

Commercial Applications Generation Load Monitoring Demand Management 16

Solar DC System Generation 17

Solar AC System Generation 18

Grid Connected System Generation 19

Sub-Metering AC Mains Distribution Panel to Individual Units Sub-Meters Load Monitoring 20

Commercial Sub-Metering 21

Data Collection 22

Other Sub-Metering Applications Building Management HVAC Lighting Computer/Server Arrays Factory Work Cells Processing Plant Stages Load Monitoring 23

Vehicle Charging AC Mains Sub-Meter Load Monitoring 24

Demand Management Monitoring Manual Load Shedding Automatic Load Shedding Branch Circuit Limit Alarm Demand Controller 25

System Configurations 26

Industrial Products Panel Instruments Systems Wireless Products Smart Meters Services 27

Panel Instruments 28

Energy Meter Parameters kwh delivered & received kvar delivered & received kw real time kw per phase kvar real time kvar per phase kva real time kva per phase % Power Factor Power Factor per phase Total Amps Average Amps Amps per phase Average volts, line to neutral Average volts, line to line Volts to neutral per phase Volts line to line Average phase angle Phase angle per phase Frequency 29

Current Transformers Solid core for cost, reliability Split core for easy retrofit Specified by ratio, accuracy class & burden Burden sets maximum secondary load R Metering CTs may require heavy leads 30

Systems 31

Current Transducer A:mV transducer Locate far from meter with no accuracy loss 32

"Green" Meter kwh in dollars Estimated cost per hour, based on current load CO 2 emissions in pounds, based on DOE data Estimated hourly CO 2 emissions based on current load Net metering, including utility delivered vs. usergenerated power 33

Software 34

Wireless Products 35

Smart Socket Meters Accurate energy measurement Advanced power quality recording Wire or wireless communication 36

Services Energy Audit Remote Energy Monitoring DSL CONNECTION EMS PC EMS PC GSM /CDMA MODEM GSM/CDMA TOWER ISP (Internet Service Provider) REMOTE MONTORING CENTER Online Data Analysis 37

Case Study Chemical Plant $k/mo Production Energy Profits Before 1943 357 93 After 1943 300 140 16% energy savings resulted in >50% profit increase 38

Test Equipment Power Monitors Power Quality Analyzers Power Dataloggers 39

Power Quality Analyzer PQ Parameters Dips & Swells Harmonics Interruptions Flicker Inrush Graphical Display Analysis Scope, Phasor Diagrams Setup Prompts 40

Calculations 41

Connections 42

Summary Key Factors in Equipment Selection: Permanent or Temporary Installation Turn-key or Build your Own Parameters to be Measured Mains Configuration Distance to Sensors Type of Display Needed Computer Interface/Software Control or Alarm Outputs Size, Cost. 43

68 Years of Power & Process Measurements 44

45

Final Thoughts Energy costs are controllable Easier to reduce than other cost factors ARRA 2009 provides $20B for energy efficiency programs State & Federal tax incentives also available Measure & Verify required to substantiate any improvement Thanks to E-MON, Conzerv, AEMC, Fluke & Yokogawa for providing material for this presentation. 46