Spectrometers: Sources Monochromators Detectors

Similar documents
Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Experiment #5: Qualitative Absorption Spectroscopy

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

FTIR Instrumentation

Raman Spectroscopy Basics

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

GRID AND PRISM SPECTROMETERS

Introduction to reflective aberration corrected holographic diffraction gratings

Time out states and transitions

MCAL Spectrophotometry. Spectrophotometry

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Synthetic Sensing: Proximity / Distance Sensors

Introduction to Fourier Transform Infrared Spectrometry

Raman spectroscopy Lecture

Optical Communications

Fig.1. The DAWN spacecraft

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

Copyright by Mark Brandt, Ph.D. 12

Study Guide for Exam on Light

3 - Atomic Absorption Spectroscopy

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Physics 10. Lecture 29A. "There are two ways of spreading light: to be the candle or the mirror that reflects it." --Edith Wharton

v = fλ PROGRESSIVE WAVES 1 Candidates should be able to :

Physics 30 Worksheet # 14: Michelson Experiment

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Light Control and Efficacy using Light Guides and Diffusers

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Chapter 17: Light and Image Formation

SPECTROSCOPY. Light interacting with matter as an analytical tool

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Spectroscopic Methods

Theremino System Theremino Spectrometer Technology

Waves Sound and Light

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Blackbody Radiation References INTRODUCTION

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Experiment 5. Lasers and laser mode structure

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Fiber Optics: Fiber Basics

Using the Spectrophotometer

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

Projects. Objective To gain hands-on design and measurement experience with real-world applications. Contents

C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same

How To Understand Light And Color

Module 13 : Measurements on Fiber Optic Systems

Modern Classical Optics

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

COLLATED QUESTIONS: ELECTROMAGNETIC RADIATION

PHYSICS PAPER 1 (THEORY)

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Introduction to Optics

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Clinical Laboratory Instrumentation

Measuring the Point Spread Function of a Fluorescence Microscope

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

RAY TRACING UNIFIED FIELD TRACING

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

A Guide to Acousto-Optic Modulators

Solution Derivations for Capa #14

Lecture 3: Fibre Optics

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Physics 25 Exam 3 November 3, 2009

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

2 Absorbing Solar Energy

Optical laser beam scanner lens relay system

CHAPTER D1 ION OPTICS OF MAGNETIC/ELECTRIC SECTOR MS

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

C101-E142 TALK LETTER. Vol. 16

instruments Analytical Instruments for Science

Lecture 1: Basic Concepts on Absorption and Fluorescence

A down-under undergraduate optics and photonics laboratory

ORIEL. FT-IR Spectroscopy SECTION FOUR FEATURES. Glossary of Terms Introduction to FT-IR Spectroscopy

SPECTROPHOTOMETRIC MEASUREMENTS TECHNIQUES FOR FERMENTATION PROCESS BASE THEORY FOR UV-VIS SPECTROPHOTOMETRIC MEASUREMENTS

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Information about the T9 beam line and experimental facilities

INFRARED PARTS MANUAL

Code number given on the right hand side of the question paper should be written on the title page of the answerbook by the candidate.

1 of 9 2/9/2010 3:38 PM

O6: The Diffraction Grating Spectrometer

Spectroscopy Using the Tracker Video Analysis Program

TECNOTTICA CONSONNI SRL CERTIFIED QUALITY MANAGEMENT SYSTEM COMPANY BY DNV UNI EN ISO 9001:2008

Applications. Blue IF 039, Green IF 062, Yellow IF 022, Orange IF 041, Red IF 090,Dark Red IF 091 IR pass IF 092, IF098, IF 093 Surface 1 5/2 0.

Size Of the Image Nature Of the Image At Infinity At the Focus Highly Diminished, Point Real and Inverted

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Review for Test 3. Polarized light. Action of a Polarizer. Polarized light. Light Intensity after a Polarizer. Review for Test 3.

Uses of Derivative Spectroscopy

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

Transcription:

Spectrometers: Sources Monochromators Detectors

Overview of a Simple Spectrophotometer (not really so simple) The typical spectrophotometer is made up of a complex arrangement of mirrors (collimators), lenses, slits, etc. By comparison, the spectrophotometer based on the photodiode array detector (PDA) provides an elegant solution to UV/VIS absorption measurements; however, it typically suffers from poor resolution (0.5 nm for PDA vs. 0.05 nm). PDA s are conventionally used as real-time detectors for compounds with chromophoric species, i.e., where compounds absorb in the region of UV/VIS. Significantly more on PDA s later.

Typical Spectrophotometers Every spectrophotometer is made up of essentially the same hardware. Splitting the beam (dotted lines) into a reference cell following wavelength selection is often used with more sophisticated UV/VIS spectrophotometers. Source Filter or Monochromator Sample Reference Detector Electronics

Component Overview of UV/VIS Spectrophotometers Sources Low pressure hydrogen or dueterium discharge tubes (UV) Xe lamp Tungsten lamp (VIS) LASER (not for UV/VIS - fluorescence) (later) Wavelength selection Filters Monochromators Prisms Gratings Slits Transducers Phototubes Photomultiplier Tubes Multichannel Photon Transducers Photodiode Arrays Charge Transfer Devices Charge Injection Devices Charge coupled Devices Thermal Transducers (infrared radiation) (later)

Radiation (overview) Skoog Holler Nieman Chapter 6 The frequency of radiation does not change in traversing a medium; however, the velocity does (p118 SHN). This forms the basis of describing refractive index (p124 SHN). Note that as a beam of radiation (say 450 nm) traverses a medium there is a loss of velocity, but that it does not result in permanent energy transfer. Consider the following table. Some common sources and their associated energies are presented for comparative purposes. hc E = = λ hv Sources Wavelength (nm) Energy (J) Energy (ev) Wavenumber (cm -1 ) Frequency (Hz or s -1 ) X-ray 3 6.62E-17 413 3.33E+06 1.0E+17 Vacuum UV 30 6.62E-18 41 3.33E+05 1.0E+16 UV 200 9.93E-19 6.2 5.00E+04 1.5E+15 VIS 600 3.31E-19 2.1 1.67E+04 5.0E+14 IR 3000 6.62E-20 0.41 3.33E+03 1.0E+14 microwave 30000 6.62E-21 0.041 3.33E+02 1.0E+13

UV/VIS Considerations Molecules may be thermolabile and could breakdown upon prolonged exposure to the incident radiation, from white light (broad band) exposure (sample heating) Incident radiation can be intense white light (broad band) provided the sample exposure time is minimal (<1s). This is the concept used in spectrophotometers based on PDA detectors (later). Monochromators permit selected wavelengths to pass through the sample, which if you think about it significantly reduces the possibility of heating the sample during absorbance measurement at that wavelength. Also, since UV/VIS spectrophotometers are generally not based on multi-channel detectors, we have to coordinate the detector response with a specific incoming wavelength (e.g., a photomultiplier cannot discriminate between λ=300 and λ=500 nm). Target analytes may be part of a suspension of particles. As such, we have to concern ourselves with light scattering. This also presents limitations based on system noise (later). If λ >> particle diameter - Rayleigh scattering If λ << particle diameter - colloidal appearance

Sources The following diagram provides an overview of a simple spectrophotometer. We are interested at this time at the source of radiation, which is in this example a tungsten lamp. Why is there a lens positioned in front of the slit? Light Source

Light Sources Skoog Holler Nieman Chapter 13 p313 The typical wavelength ranges studied are: 160-375nm (H 2 /D 2 discharge tubes). UV lamps based on Hg are also common. 350-2500 nm as the most common output regions for Tungsten lamps. The efficiency of a W lamp output below 300 nm is low, and as such a UV lamp is thereby also required to provide reliable radiation at the higher energy levels. E out ~(Voltage) 4. For this reason, V has to be extremely stable. W/halogen lamps (W/I) - extremely efficient, also produces UV High intensity outputs don t provide an advantage to quantitative determinations (recall measuring difference in absorption of specific wavelengths). These outputs are quite useful for high resolution work where narrow slit widths are used (more on slit widths later).

Interim Summary So, we now have a source of broad band UV/VIS radiation. Unless a multichannel detector is used in the instrument, we will need to select specific wavelengths. Consider the following diagram: Slit Wavelength Selector (one of many types)

Wavelength Selectors Skoog Holler Nieman Chapter 7 p154 A narrow band of radiation incident on a sample is required to ensure both sensitivity and selectivity of absorption measurements. In particular, narrow bands are required with linear systems (such as a monochromator on an axis) to ensure linearity of response as a function of (sample) [analyte]. Filters Interference filters Interference wedges Absorption filters Monochromators Prism monochromators Grating monochromators The echellette (and echelle) grating Concave gratings Holographic gratings Slits Important part of a monochromator

Filters Skoog Holler Nieman Chapter 7 p155 Interference Filters (and wedges) These filters rely on optical interference (destructive wave addition) to provide narrow bands of radiation. The dielectric layer thickness determines the λ of transmitted radiation. (Wedge - t varies. ) 2 t η λ = n where : t is the dielectric thickness η is refractive index of dielectric n is the order of intereference λ is the transmitted wavelength atθ = 0 o Absorption Filters Here we are talking about coloured glass or a dye that absorbs the wavelength we wish to reject. Bandwidths are extremely large (30 to 250 nm) (see next page). Combining two absorption filters of different λ max can yield a bandpass filter. CaF 2 or MgF 2

Comparison Between Interference and Absorption Filters Skoog Holler Nieman Chapter 7 p155 Basically, the interference filter can provide superior bandwidth definition over an absorption filter: It is noteworthy to recognize that the greater the bandwidth definition the lower the %transmittance through that filter.

Monochromators Skoog Holler Nieman Chapter 7 p157 The monochromator is vital in its role to vary the energy of radiation incident on a sample - thus providing a spectral scan. The concept is straightforward - focus the dispersed radiation onto an exit slit. That radiation is then incident on the sample. Two basic types of monochromators: Prism Grating (reflective processes) One must be aware of the fact that prisms do not provide a linear dispersion of radiation, whereas a grating does:

Monochromators - Prisms Skoog Holler Nieman Chapter 7 p157 The Bunsen prism monochromator. Note that λ 1 > λ 2. This unit is comprised of a number of elements. Entrance slit Collimating lens (to disperse the incoming white radiation into parallel streams) A prism, on which the incoming radiation is dispersed at both surfaces Another lens, this time to focus the collimated beam to a rectangular points along the focal plane A exit slit which can be narrowed or enlarged as required, depending on required resolution (later on slits). Note that all wavelength elements are present on the focal plane; however, only those selected to exit the unit are positioned at the exit slit. Prisms are sometimes used in line with a grating (later).

Monochromators - Reflective Gratings Skoog Holler Nieman Chapter 7 p157 A Czerney-Turner grating monochromator. Note that λ 1 > λ 2. This unit is comprised of a number of elements Entrance slit A concave mirror to spread out the incoming radiation to a width that will maximize the amount of radiation incident on the grating A reflective grating which disperses the incoming radiation depending on incident angle and reflective angle Another concave mirror, this time to A exit slit which can be narrowed or enlarged as required, depending on required resolution (later on slits); however, for a reflective grating, the slit widths can remain essentially constant.

Czerny-Turner Mounting