6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Main Catalog 2012/2013 for specialists in automation and control technology

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES BE01-0AB0 6ES BE01-0AB0

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

CPUs - CPU PN/DP

CPU PN/DP. Function


SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

S and STEP 7 Basic V10.5

Siemens AG /42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

CP Page 1342 Mar 2008 Siemens ITS

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

The CP provides access to different communication services of the PROFIBUS bus system:

DS1621 Digital Thermometer and Thermostat

The CP FO provides access to different communication services of the PROFIBUS bus system:

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

PCS0100en Persy Control Services B.V. Netherlands

NEW. EVEN MORE data acquisition and test stand automation

Technical Information POWER PLANT CONTROLLER

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

RS - SPM. Serial parallel translator module

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

SIMATIC S /2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC S /2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules

Modular I/O System Analog and Digital Interface Modules

Rack mounted telephone- and leased line modem for industrial applications

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

Permissible ambient temperature Operation Storage, transport

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Telephone- and leased line modem for industrial applications TD-36

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

DS1621 Digital Thermometer and Thermostat

Digital input modules

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

NC-12 Modbus Application

Preset Counter signo 721

Flexible Counter Series in DIN size 24 x 48 mm

DS1104 R&D Controller Board

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Programmable Controller G Series. New. Models

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Safety technique. Emergency stop module BO 5988 safemaster

Analog Inputs and Outputs

Optimize your simple machines... Modicon M218 Selection Guide

Programming Logic controllers

S7-1500/S7-1500F Technical Data

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Temperature & Humidity SMS Alert Controller

M-series Virtual I/O Module 2

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Automation Unit TM 1703 ACP Flexible automation and telecontrol

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Vibration analysis and monitoring Compact. Powerful. Modern technology.

GPS NTP TIME SERVER Rack Version V2.2x

Multifunction devices

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

Install the DeviceNet Module using the following procedure:

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

E-STOP relays, safety gate monitors

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

MicroMag3 3-Axis Magnetic Sensor Module

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

Nemo 96HD/HD+ MODBUS

DC Electronic Loads 8500 series

DS1307ZN. 64 x 8 Serial Real-Time Clock

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

GPS NTP TIME SERVER Rack Version V2

ABB RTU560A Series CMU & Modules

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Transcription:

Data sheet CPU M13C (M13-CCF0000) Technical data Order no. M13-CCF0000 Type CPU M13C Module ID - General information Note - Features SPEED7 technology 16 x DI, 12 x DO, 2 x AI, from which are 4 input channels parameterizable for counters and frequency measurement and 2 Output channels for PWM 64 kb work memory Memory extension (max. 128 kb) optionell PROFIBUS-DP slave / PtP (switchable) Technical data power supply Power supply (rated value) DC 24 V Power supply (permitted range) DC 20.4...28.8 V Reverse polarity protection Current consumption (no-load operation) 120 ma Current consumption (rated value) 360 ma Inrush current 3 A I²t 0.1 A²s Max. current drain at backplane bus 1 A Max. current drain load supply - Power loss 7 W Technical data digital inputs Number of inputs 16 Cable length, shielded Cable length, unshielded Rated load voltage Reverse polarity protection of rated load voltage Current consumption from load voltage L+ (without load) Rated value Input voltage for signal "0" Input voltage for signal "1" Input voltage hysteresis - Frequency range - Input resistance - Input current for signal "1" Connection of Two-Wire-BEROs possible Max. permissible BERO quiescent current Input delay of "0" to "1" Input delay of "1" to "0" Number of simultaneously utilizable inputs horizontal configuration 1000 m 600 m DC 24 V 25 ma DC 24 V DC 0...5 V DC 15...28.8 V 3 ma 0.5 ma 3 µs 15 ms / 0.5 ms 15 ms 3 µs 15 ms / 0.5 ms 15 ms 16 Page 1/9

Number of simultaneously utilizable inputs vertical configuration 16 Input characteristic curve IEC 61131-2, type 1 Initial data size 16 Bit Technical data digital outputs Number of outputs 12 Cable length, shielded 1000 m Cable length, unshielded 600 m Rated load voltage DC 24 V Reverse polarity protection of rated load voltage Current consumption from load voltage L+ (without load) 20 ma Total current per group, horizontal configuration, 40 C 6 A Total current per group, horizontal configuration, 60 C 6 A Total current per group, vertical configuration 6 A Output voltage signal "1" at min. current L+ (-0.8 V) Output voltage signal "1" at max. current L+ (-0.8 V) Output current at signal "1", rated value 0.5 A Output current, permitted range to 40 C 5 ma to 0.6 A Output current, permitted range to 60 C 5 ma to 0.6 A Output current at signal "0" max. (residual current) 0.5 ma Output delay of "0" to "1" 2 µs / 30 µs Output delay of "1" to "0" 3 µs / 175 µs Minimum load current - Lamp load 10 W Parallel switching of outputs for redundant control of a load not possible Parallel switching of outputs for increased power not possible Actuation of digital input Switching frequency with resistive load max. 1000 Hz Switching frequency with inductive load max. 0.5 Hz Switching frequency on lamp load max. 10 Hz Internal limitation of inductive shut-off voltage L+ (-45 V) Short-circuit protection of output, electronic Trigger level 1 A Number of operating cycle of relay outputs - Switching capacity of contacts - Output data size 12 Bit Technical data analog inputs Number of inputs 2 Cable length, shielded 200 m Rated load voltage - Reverse polarity protection of rated load voltage - Current consumption from load voltage L+ (without load) - Voltage inputs Min. input resistance (voltage range) 100 kohm Input voltage ranges 0 V... +10 V Operational limit of voltage ranges +/-3.5% Operational limit of voltage ranges with SFU - Basic error limit voltage ranges +/-3.0% Page 2/9

Basic error limit voltage ranges with SFU - Destruction limit voltage max. 30V Current inputs - Max. input resistance (current range) - Input current ranges - Operational limit of current ranges - Operational limit of current ranges with SFU - Basic error limit current ranges - Radical error limit current ranges with SFU - Destruction limit current inputs (electrical current) - Destruction limit current inputs (voltage) - Resistance inputs - Resistance ranges - Operational limit of resistor ranges - Operational limit of resistor ranges with SFU - Basic error limit - Basic error limit with SFU - Destruction limit resistance inputs - Resistance thermometer inputs - Resistance thermometer ranges - Operational limit of resistance thermometer ranges - Operational limit of resistance thermometer ranges with SFU - Basic error limit thermoresistor ranges - Basic error limit thermoresistor ranges with SFU - Destruction limit resistance thermometer inputs - Thermocouple inputs - Thermocouple ranges - Operational limit of thermocouple ranges - Operational limit of thermocouple ranges with SFU - Basic error limit thermoelement ranges - Basic error limit thermoelement ranges with SFU - Destruction limit thermocouple inputs - Programmable temperature compensation - External temperature compensation - Internal temperature compensation - Technical unit of temperature measurement - Resolution in bit 12 Measurement principle successive approximation Basic conversion time 0.5 ms Noise suppression for frequency 40 db Initial data size 4 Byte Technical data analog outputs Number of outputs - Cable length, shielded - Rated load voltage - Reverse polarity protection of rated load voltage - Current consumption from load voltage L+ (without load) - Voltage output short-circuit protection - Page 3/9

Voltage outputs - Min. load resistance (voltage range) - Max. capacitive load (current range) - Max. inductive load (current range) - Output voltage ranges - Operational limit of voltage ranges - Basic error limit voltage ranges with SFU - Destruction limit against external applied voltage - Current outputs - Max. in load resistance (current range) - Max. inductive load (current range) - Typ. open circuit voltage current output - Output current ranges - Operational limit of current ranges - Radical error limit current ranges with SFU - Destruction limit against external applied voltage - Settling time for ohmic load - Settling time for capacitive load - Settling time for inductive load - Resolution in bit - Conversion time - Substitute value can be applied - Output data size - Technical data counters Number of counters 4 Counter width 32 Bit Maximum input frequency 100 khz Maximum count frequency 400 khz Mode incremental encoder Mode pulse / direction Mode pulse Mode frequency counter Mode period measurement Gate input available Latch input available Reset input available - Counter output available Load and working memory Load memory, integrated Load memory, maximum Work memory, integrated Work memory, maximal Memory divided in 50% program / 50% data Memory card slot 128 KB 128 KB 64 KB 128 KB SD/MMC-Card with max. 2 GB Hardware configuration Racks, max. 1 Modules per rack, max. 8 Page 4/9

Number of integrated DP master - Number of DP master via CP - Operable function modules - Operable communication modules PtP - Operable communication modules LAN - Status information, alarms, diagnostics Status display Interrupts Process alarm Diagnostic interrupt Diagnostic functions Diagnostics information read-out Supply voltage display Group error display Channel error display, parameterizable, parameterizable, parameterizable, parameterizable possible green LED red LED red LED per group Isolation Between channels Between channels of groups to 16 Between channels and backplane bus Between channels and power supply - Max. potential difference between circuits DC 75 V/ AC 50 V Max. potential difference between inputs (Ucm) - Max. potential difference between Mana and Mintern (Uiso) - Max. potential difference between inputs and Mana (Ucm) - Max. potential difference between inputs and Mintern (Uiso) - Max. potential difference between Mintern and outputs - Insulation tested with DC 500 V Command processing times Bit instructions, min. 0.02 µs Word instruction, min. 0.02 µs Double integer arithmetic, min. 0.02 µs Floating-point arithmetic, min. 0.12 µs Timers/Counters and their retentive characteristics Number of S7 counters 512 S7 counter remanence adjustable 0 up to 256 S7 counter remanence adjustable C0.. C7 Number of S7 times 512 S7 times remanence adjustable 0 up to 256 S7 times remanence adjustable not retentive Data range and retentive characteristic Number of flags 8192 Byte Bit memories retentive characteristic adjustable adjustable 0 up to 256 Bit memories retentive characteristic preset MB0.. MB15 Number of data blocks 1024 Max. data blocks size 64 KB Page 5/9

Max. local data size per execution level 4096 Byte Blocks Number of OBs 22 Number of FBs 1024 Number of FCs 1024 Maximum nesting depth per priority class 16 Maximum nesting depth additional within an error OB 4 Time Real-time clock buffered Clock buffered period (min.) 30 d Accuracy (max. deviation per day) 10 s Number of operating hours counter 8 Clock synchronization Synchronization via MPI Master/Slave Synchronization via Ethernet (NTP) no Address areas (I/O) Input I/O address area 2048 Byte Output I/O address area 2048 Byte Input process image maximal 2048 Byte Output process image maximal 2048 Byte Digital inputs 144 Digital outputs 140 Digital inputs central 144 Digital outputs central 140 Integrated digital inputs 16 Integrated digital outputs 12 Analog inputs 2 Analog outputs 0 Analog inputs, central 2 Analog outputs, central 0 Integrated analog inputs 2 Integrated analog outputs 0 Communication functions PG/OP channel Global data communication Number of GD circuits, max. 8 Size of GD packets, max. 54 Byte S7 basic communication S7 basic communication, user data per job 76 Byte S7 communication S7 communication as server S7 communication as client - S7 communication, user data per job 160 Byte Number of connections, max. 32 PWM data Page 6/9

PWM channels 2 PWM time basis 1 µs / 0.1 ms / 1 ms Period length - Minimum pulse width 0...0.5 * Period duration Type of output Highside Functionality Sub-D interfaces Type X1 Type of interface RS422/485 isolated Connector Sub-D, 9-pin, female Electrically isolated MPI - MP²I (MPI/RS232) - DP master - DP slave - Point-to-point interface 5V DC Power supply max. 90mA, isolated 24V DC Power supply - Type X2 Type of interface RS485 isolated Connector Sub-D, 9-pin, female Electrically isolated MPI MP²I (MPI/RS232) - DP master - DP slave optional Point-to-point interface - 5V DC Power supply max. 90mA, isolated 24V DC Power supply - Functionality MPI Number of connections, max. 32 PG/OP channel Routing Global data communication S7 basic communication S7 communication S7 communication as server S7 communication as client - Transmission speed, min. 19.2 kbit/s Transmission speed, max. 12 Mbit/s Functionality PROFIBUS slave PG/OP channel Routing S7 communication S7 communication as server S7 communication as client - Page 7/9

Direct data exchange (slave-to-slave communication) - DPV1 Transmission speed, min. 9.6 kbit/s Transmission speed, max. 12 Mbit/s Automatic detection of transmission speed Transfer memory inputs, max. 244 Byte Transfer memory outputs, max. 244 Byte Address areas, max. 32 User data per address area, max. 32 Byte Point-to-point communication PtP communication Interface isolated RS232 interface - RS422 interface RS485 interface Connector Sub-D, 9-pin, female Transmission speed, min. 150 bit/s Transmission speed, max. 115.2 kbit/s Cable length, max. 500 m Point-to-point protocol ASCII protocol STX/ETX protocol 3964(R) protocol RK512 protocol - USS master protocol Modbus master protocol Modbus slave protocol Special protocols - Functionality RJ45 interfaces Type - Type of interface Ethernet 10/100 MBit Switch Connector 2 x RJ45 Electrically isolated PG/OP channel Number of connections, max. 4 Productive connections Fieldbus - Type - Type of interface - Connector - Electrically isolated - PG/OP channel - Number of connections, max. - Productive connections - Fieldbus - Page 8/9

Ethernet communication via PG/OP Number of productive connections via PG/OP, max. 2 Number of productive connections by Siemens NetPro, max. 2 S7 connections User data per S7 connection, max. TCP-connections User data per TCP connection, max. ISO on TCP connections (RFC 1006) User data per ISO connection, max. BSEND, BRCV, GET, PUT, Connection of active and passive data handling 64 KB FETCH PASSIV, WRITE PASSIV, Connection of passive data handling 8 KB FETCH PASSIV, WRITE PASSIV, Connection of passive data handling 8 KB Ethernet open communication via PG/OP Number of configurable connections, max. 2 ISO on TCP connections (RFC 1006) User data per ISO on TCP connection, max. TCP-Connections native User data per native TCP connection, max. User data per ad hoc TCP connection, max. UDP-connections User data per UDP connection, max. TSEND, TRCV, TCON, TDISCON 32 KB TSEND, TRCV, TCON, TDISCON 32 KB 1460 Byte TUSEND, TURCV 1472 Byte Housing Material Mounting PPE / PPE GF10 Profile rail 35 mm Mechanical data Dimensions (WxHxD) Net weight Weight including accessories Gross weight 72 mm x 88 mm x 71 mm 221 g 221 g 240 g Environmental conditions Operating temperature 0 C to 60 C Storage temperature -25 C to 70 C Certifications UL certification KC certification in preparation in preparation Page 9/9