UNICOM III Probe PG C.

Similar documents
Safety Precautions WARNINGS

Caplio Utility for Windows

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

RS485 Adapters. User Manual October 26, 2008 V1.02 Copyright Light O Rama, Inc. 2006, 2007, 2008 SC485 USB485B USB485 USB485-ISO

Use only a shielded parallel interface cable that is IEEE 1284-compliant and/or a USB cable that is no longer than 6 feet long (1.8 meters).

Installation Instructions for 9555 USB Driver

USB Driver INSTALLATION GUIDE 6 NOVEMBER 2013 RIGHT SOLUTIONS RIGHT PARTNER D B

Installing the Gerber P2C Plotter USB Driver

IrDA-USB IrDA USB Adapter

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS

PL-2303 (Chip Rev H, HX, X) USB to Serial Adapter Windows Driver Installer Manual

Installing PowerLink on Windows 7 64-bit

Universal Serial Bus (USB) to DH-485 Interface Converter

Connecting your Omega/BetaPAT PLUS to a PC via a USB

USA MOBILITY CABLE CONNECTION AND SOFTWARE DRIVER INSTALLATION INSTRUCTIONS. For. Unication M90 Device USB To RS232 Adapter TABLE OF CONTENTS

Chapter 1 Downloading Images to Your Computer (Windows)

1 Port FTDI USB to RS232 Null Modem Adapter

RIGtalk. Revision 5. Owner s Manual 2012.

Transmitter Interface Program

NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000)

EPSON USB/Parallel Adapter User s Guide

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

PCMCIA 1 Port RS EDITION OCTOBER 1999

SOFTWARE INSTALLATION INSTRUCTIONS

1. SAFETY INFORMATION

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

Screen Capture. User s Guide. For ClassPad Series

DIAL-UP DATA. User s Guide

User Manual. Thermo Scientific Orion

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

Network Installation Guide

USB Driver Installation for Windows XP

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay

Centurion PLUS CPC4 Download Guide

2-Port RS232/422/485 Combo Serial PCI Card

Schneider OS-Loader usage via Ethernet or USB.

USB DRIVER INSTALLATION GUIDE

GV-Keyboard. User's Manual V2.0

ATX Document Manager. User Guide

Select Correct USB Driver

Fiery E100 Color Server. Welcome

Professional USB to Serial Adapter Hub with COM Retention

Guide to Installing BBL Crystal MIND on Windows 7

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

Iridium Extreme TM Satellite Phone. Data Services Manual

Getting Started. rp5800, rp5700 and rp3000 Models

Install Device Drivers and Toolkit for Windows 7

WinLIN Setup and Operation:

Phone: Fax: Web: info@ctiautomation.net

XConsole GUI setup communication manual September 2010.

Config software for D2 systems USER S MANUAL

2-Serial/1-Parallel Port PCI Adapter

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges

Windows XP.. ELITE Firmware Update procedures.. v1.41

Mini Amazing Box Update for Windows XP with Microsoft Service Pack 2

USB PC Adapter V4 Configuration

USB VoIP Phone Adapter. User s Manual

USB Driver Installation Manual [Windows Vista/Windows 7]

EPSON USB/Parallel Adapter User s Guide

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

Scan2CRM for ACT! User Guide

Title Page. Reflex USB v2. Reader Installation Guide

DCT-16 USB HD Audio Converter

PrintFleet Local Beacon

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

MS830 / MS833 Barcode Reader v1.0 9-December-2014

USB Driver. Installation Manual

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Printer Support Guide. FedEx Ship Manager Software

Instruction Bulletin. PowerLogic Tenant Metering Software Installation Guide. Introduction

Document authored by: Native Instruments GmbH Hardware version: Traktor Kontrol X1 MK2 (01/2013)

How to setup a serial Bluetooth adapter Master Guide

USB to Serial Quick Installation Guide

How To Connect A Port Replicator With An Ethernet To A Usb Port From A Usb Device

485USBTB-2W & 485USBTB-4W

e-dpp May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database

Serial ATA 2 Ports PCI Host

Pre-Installation: Personal Storage 3100 Installation Guide. Hardware and Operating System Requirements for Windows PC

Producing Standards Based Content with ToolBook

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

Data Management Software. CL-S10w. Installation Guide

DriveRight. Fleet Management Software. Getting Started Guide. CarChip. DriveRight. Drivers. Vehicles. Product #8186

WHQL Certification Approval...2 User Interface K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5

Windows XP Home Edition / Windows XP Professional

USB/RS485 Communication Cable Installation

SAFEPATH 4 Telephone Zone Controller

FileMover 1.2. Copyright Notice. Trademarks. Patents

Metasys System Direct Connection and Dial-Up Connection Application Note

USB DRIVER INSTALLATION GUIDE

Orbit PCI Mk 2 Network Card. User Manual. Part No Issue 4

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

ScanShell.Net Install Guide

JTAGjet. series SIGNUM SYSTEMS CORPORATION. USB 2.0 Driver for JTAGjet and ADM51. Installation Instructions

2/4/8 Port USB to Serial Adapter Hub with COM Retention

Installing USB Drivers With Microsoft Windows XP

Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents

Transcription:

PG42-1008C www.elster.com

PG42-1008C 3 Contents Contents 1 Introduction..........................................4 Common optical probe styles.......................4 Probes for ANSI Type 1 port.........................5 Supported software................................5 Connecting the probe to a computer.....................5 Non-USB connector probe..........................6 USB connector probe..............................6 Connecting the probe to a meter........................6 ANSI optical probe................................6 IEC optical probe..................................7 IEC adapter for ANSI optical probe...................8 ANSI optical probe retention spring..................9 2 Installing the drivers.................................. 10 Supported software.................................. 10 Installing the USB device drivers........................ 10 Windows 2000.................................. 10 Windows XP..................................... 16 Windows 7...................................... 21 Upgrading the UNICOM III Probe device drivers......... 24 3 Using the probe.....................................27 Using the UNICOM III Probe (USB connector).............27 Determining COM Port Number...................27 Configuring support software to use the COM port.. 29 Troubleshooting................................ 29 Port Conflict in Port Usage....................... 29 Multiple USB ports on a computer................. 31 4 Installing the UNICOM III with USB to Serial Adapter...... 32

PG42-1008C 4 1. Introduction 1 Introduction The UNICOM III probe is a portable optical (infrared) communications device that transfers digital information between Elster electronic meters, EMF registers, and other reader/ programmer equipment. Two basic configurations of probes are available: one is compatible with the mechanical and optical specifications of the ANSI C12.18 standard and the other is compatible with the IEC 1107 FLAG port. Elster offers the standard DB-9 serial connector or a USB (universal serial bus) connector as well as connectors for third party hardware such as DAP MICROFLEX (LEMO), Itron FS/2 and FS/3 (AMPHENOL), and Itron G5 (HIROSE). Contact Elster for details. Elster s UNICOM III probe supports up to 57,600 bps communication with electricity meters equipped with ANSI C12.18 or IEC 61107 FLAG compliant optical ports. The UNICOM III probe does not use a battery pack, special power connector, or AC adapter. Its state of the art circuits are powered directly from the computer s RS-232 DB-9 serial port, USB port, or other third party hardware port. The UNICOM III probe has the following additional features: operates over wide temperature range (-40 C to +85 C) uses a sunlight filter to enhance infrared (IR) communications in bright sunlight probe molded from lightweight, durable polycarbonate plastic cable jacket molded from high endurance polyurethane equipped with a super powerful rare earth retention magnet for attaching to a metal port plate on a meter equipped with a removable retention spring for attaching to the plastic port under the cover of an Elster meter optional optical port adapter available for using ANSI style probes with IEC 61107 FLAG compliant meters RS-232 models support true RS-232 ± electrical signal levels USB models support USB 1.1 and USB 2.0 standards Common optical probe styles The following table lists the most common Elster probe styles. Note: Other configurations are available, including probes with different connectors (such as LEMO, AMPHENOL, and HIROSE) and cables. ANSI probes (connector type) Style number 10 ft (3 m) retractile coil cable (DB-9) 5D25274G01 6 ft (2 m) retractile coil cable (DB-9) 5D25274G02 10 ft (3 m) retractile coil cable with calibration pulse output via RCA connector NPN Transistor rated 15 ma Max (DB-9) 5D25274G96 Adapter for ANSI probes to accommodate IEC 61107 FLAG port 3A34485G01 6 ft (2 m) straight cable (USB) 1 5D25334G01

PG42-1008C 5 1. Introduction IEC 61107 probes Style number 3 m (10 ft) retractile coil cable (DB-9) 5D25274G03 2 m (6 ft) retractile coil cable (DB-9) 5D25274G04 2 m (6 ft) straight cable (USB) 1 5D25334G04 1. Requires USB device drivers available from Elster s Web site (http://www.elstersolutions.com). Probes for ANSI Type 1 port The patented optical communications technology used for certain EMF electronic registers (Westinghouse and ABB Types EMF-1A, EMF-1B, EMF-2, and EMF-2110) have a Type 1 communications port. Consult Elster Sales Support for availability of the Type 1-compliant probe. Supported software The UNICOM III probe has been tested and works with the following Elster meter support software products: Meter Support Software AlphaPlus 1.30 or higher (domestic and international) Metercat meter support software A1200 ALPHA Meter Support Software Meters ALPHA, ALPHA Plus, and AIN ALPHA meters A3 ALPHA meters, A1800 ALPHA meters, REX and REX2 meters A1200 ALPHA meters Note: For UNICOM III probes with the standard DB-9 connector, the meter support software must turn on either the RTS or DTR RS-232 signal prior to initiating communications. This is the source of power for the probe. Do not turn on both control signals as this signals the probe to support a variant to the standard protocol that inverts the digital logic of the Tx LED. The UNICOM III probe also supports meters (for example, certain meters from Landis+Gyr) that use a variant to the ANSI C12.18 Tx signal. To communicate with these meters, the meter support software uses RTS to signal the probe to turn on and DTR to signal the probe to invert the Tx digital logic for the optical signal. In this situation only, both RTS and DTR should be turned on. For probes with special connectors for third party hardware, the Tx digital logic is inverted when DTR is asserted regardless of the state of RTS. These probes are directly powered by the third party hardware power supply. The UNICOM III probe has an internal wire jumper between DTR and DCD. This connection is the probe signature. Some meter support software use this jumper to determine which COM port has the connected probe. Also, the UNICOM III probe asserts the DSR signal which some meter support software uses to determine that the probe is powered. Note: To aid in development of custom applications, the UNICOM III probe equipped with the standard DB-9 connector may be powered by applying a 5-15 VDC source at Pin 9. Connecting the probe to a computer A UNICOM III probe can be purchased that supports a variety of connection types. The standard probe has a DB-9 serial connector that fits on a computer s serial port. If the computer uses Windows 2000/XP and has a USB port, you can use a USB to serial adapter or you can purchase the UNICOM III probe for USB connections. Depending on the type of connector your probe uses, install the probe using the appropriate procedure for your probe.

PG42-1008C 6 1. Introduction Use authorized utility procedures to read metering equipment. Dangerous voltages are present. Equipment damage, personal injury, or death can result if safety precautions are not followed. Never use UNICOM probes in high voltage equipment compartments or where dangerous voltages may be exposed in open connections and terminals. The electrical insulation on UNICOM probes is for low voltage signaling only. Probe insulation is not designed for power line distribution or higher voltages! Equipment damage, personal injury, or death can result if these instructions are not observed and if probe or connecting cord comes into contact with high voltage terminals or bus bars. Non-USB connector probe To begin using the UNICOM III probe (non-usb connector), plug the connector into the appropriate COM port on your computer. Note: You may need to configure your software to use the correct COM port. See Configuring support software to use the COM port on page 29 for details. USB connector probe See Installing the USB device drivers on page 10 for details on installing the device drivers for the UNICOM III probe with a USB connector. Connecting the probe to a meter Both ANSI and IEC probes are equipped with retention magnets. The magnet provides positive attachment to the various optical ports. The optical, mechanical, and magnetic interfaces between the ANSI and IEC UNICOM probes are similar. The ANSI compliant probe may be used on both ANSI and IEC meter types provided that the orientation of the elements is correct. To operate the ANSI probe on an IEC meter the elements must be inverted 180 to properly communicate (Figure 1-2). To ensure proper orientation, Elster recommends using the IEC Adapter for ANSI optical probes. See IEC adapter for ANSI optical probe on page 8 for more details on the probe adapter. ANSI optical probe The ANSI probe uses a keyed mounting hole suitable for ANSI ports.

PG42-1008C 10 2. Installing the drivers 2 Installing the drivers Supported software The UNICOM III USB-connected optical probe and its device drivers have been tested and function on computers using Windows 2000, Windows XP, Windows Vista, and Windows 7 with Elster s meter support software. In 2011, Elster certified the UNICOM III optical probe with USB connection with Microsoft. The updated device drivers are included on the Metercat software installation CD in the \UNICOM III Probe USB drivers folder. Installing the USB device drivers Installing the UNICOM III probe device drivers is a two phase process: 1. Install the UNICOM III Optical Probe device driver. 2. Install the USB Serial Port device driver. Note: You will be guided through the processes by the New Hardware Wizard. The installation process depends on the operating system you have installed on your computer. Use the appropriate procedure for your operating system: Windows 2000 Windows XP Windows 7 Note: If you are currently using your USB port for another application (for example, HotSync Manager for Palm OS devices) you may receive a message about a conflict with an application that has a lock on the port when no hardware is connected. See Port Conflict in Port Usage on page 29 for details on correcting this problem. Windows 2000 To begin installing the device drivers: 1. Plug the USB connector of the UNICOM probe into the USB port on the computer. 2. Windows should automatically recognize the new device and display the New Hardware Wizard dialog (on some systems this may take some time). If Windows does not start the New Hardware Wizard, from the Windows Start menu, select Settings > Control Panel > Add/Remove Hardware.

PG42-1008C 11 2. Installing the drivers Figure 2-6. Begin the driver installation 3. Click Next. The Hardware Wizard prompts you to search for the suitable driver for the Elster UNICOM III Optical Probe. Figure 2-7. Search for the suitable driver 4. Select Search for a suitable driver for my device. 5. Click Next.

PG42-1008C 12 2. Installing the drivers Figure 2-8. Locating the driver files 6. Uncheck Microsoft Windows Update (if it is checked). 7. Check Specify a location. 8. Click Next. Figure 2-9. Locate the installation file 9. Navigate to the location of the uncompressed driver installation files. 10.Select FTDIBUS.INF in the folder where the drivers are located. 11. Click Open.

PG42-1008C 13 2. Installing the drivers Figure 2-10. Driver file found 12.Click Next. Figure 2-11. Digital signature not found 13.If you see a message that the software does not contain a digital signature, click Yes to continue with the installation.

PG42-1008C 14 2. Installing the drivers Figure 2-12. USB Optical Probe driver installed 14.Click Finish to complete the installation of the first device driver and begin installing the second device driver. The New Hardware Wizard prompts you to search for the suitable driver for the USB Serial Port. Figure 2-13. Searching for suitable driver 15.Select Search for a suitable driver for my device. 16.Click Next.

PG42-1008C 15 2. Installing the drivers Figure 2-14. Locating driver file 17. Uncheck Microsoft Windows Update (if it is checked). 18.Check Specify a location. 19.Click Next. The New Hardware Wizard remembers the location of the previous device driver. 20.Select FTDIPORT.INF in the folder where the drivers are located. 21.Click Open. Figure 2-15. Driver file found 22.Click Next.

PG42-1008C 16 2. Installing the drivers Figure 2-16. Digital signature not found 23.If you see a message that the software does not contain a digital signature, click Yes to continue with the installation. Figure 2-17. Driver installation complete 24.Click Finish to complete the installation of the UNICOM III USB Optical Probe device drivers. You are now ready to begin using the optical probe. See Configuring support software to use the COM port on page 29 for details on configuring the software to use the correct COM port. Windows XP To begin installing the device drivers: 1. Plug the USB connector of the UNICOM probe into the USB port on the computer.

PG42-1008C 17 2. Installing the drivers Windows should automatically recognize the new device and display the New Hardware Wizard dialog (it may take up to a minute on some systems). The New Hardware Wizard prompts you to search for the suitable driver for the UNICOM III Optical Probe. Figure 2-18. 2. Select No, not this time. 3. Click Next. Figure 2-19. Begin the driver installation

PG42-1008C 18 2. Installing the drivers 4. Select Install from a list or specific location to proceed with the installation of the probe drivers. 5. Click Next. Figure 2-20. Search for the suitable driver 6. Select Search for the best driver in these locations. 7. Depending on the location of the device drivers, select the appropriate option: If you have the Metercat installation CD, check the Search removable media. Or If the Metercat installation files are on a network, check Include this location in the search and Browse to the location of the installation files and select the \UNICOM III Probe USB drivers folder. 8. Click Next. If you selected the CD option, the wizard will search the removable media for the drivers. If you selected a location, the wizard will search the location specified for the driver. The wizard should then load the files and complete installation.

PG42-1008C 19 2. Installing the drivers Figure 2-21. Elster Unicom III USB Drivers Disk installed 9. Click Finish to complete the installation of the first device driver and begin installing the second device driver. The New Hardware Wizard prompts you to search for the software for the USB Optical Probe. Figure 2-22. Search for the suitable driver

PG42-1008C 20 2. Installing the drivers 10.Select Install from a list or specific location to proceed with the installation of the probe drivers. 11. Click Next. Figure 2-23. Locating the driver files 12.Select Search for the best driver in these locations. 13.Depending on the location of the device drivers, select the appropriate option: If you have the Metercat installation CD, check the Search removable media. Or If the Metercat installation files are on a network, check Include this location in the search and Browse to the location of the installation files and select the \UNICOM III Probe USB drivers folder. 14.Click Next. If you selected the CD option, the wizard will search the removable media for the drivers. If you selected a location, the wizard will search the location specified for the driver. The wizard should then load the files and complete installation.

PG42-1008C 21 2. Installing the drivers Figure 2-24. Elster Unicom III USB Optical Probe installed 15.Click Finish to complete the installation of the UNICOM III USB Optical Probe device drivers. Once the second set of drivers has been installed, you must restart your computer before using the probe. 16.From the Windows Start menu, select Shut Down > Restart. You are now ready to begin using the optical probe. See Configuring support software to use the COM port on page 29 for details on configuring the software to use the correct COM port. Windows 7 To begin installing the device drivers: 1. Plug the USB connector of the UNICOM probe into the USB port on the computer. Windows should automatically recognize the new device and display the New Hardware Wizard dialog (it may take up to a minute on some systems). Figure 2-25.

PG42-1008C 22 2. Installing the drivers The New Hardware Wizard prompts you to search for the suitable driver for the UNICOM III Optical Probe. Figure 2-26. 2. Click Close. 3. To install the drivers manually, from the Windows Start menu, select Control Panel > System. 4. Select the Hardware tab. 5. Click Device Manager. 6. From the Other devices tree, double click to open Elster Unicom III Optical Probe. The Elster Unicom III Optical Probe Properties dialog displays. Figure 2-27. Begin the driver installation 7. Click Update Driver.

PG42-1008C 23 2. Installing the drivers Figure 2-28. Search for the suitable driver 8. If the computer has an internet connection, select Search automatically for updated driver software and Windows Update installs the proper drivers. Or Select Browse my computer for driver software and browse to the location of the Metercat installation CD or the installation files and select the \UNICOM III Probe USB drivers folder. Figure 2-29. Elster Unicom III USB Drivers Disk installed 9. Click Close to complete the installation of the UNICOM III USB Optical Probe device drivers. 10.From the Windows Start menu, select Shut Down > Restart. You are now ready to begin using the optical probe.

PG42-1008C 24 2. Installing the drivers See Configuring support software to use the COM port on page 29 for details on configuring the software to use the correct COM port. Upgrading the UNICOM III Probe device drivers To begin installing the device drivers: 1. Plug the USB connector of the UNICOM probe into the USB port on the computer. 2. To upgrade the drivers manually, from the Windows Start menu, select Control Panel > System. 3. Select the Hardware tab. 4. Click Device Manager. 5. From the Other devices tree, double click to open Elster Unicom III Optical Probe. The Elster Unicom III Optical Probe Properties dialog displays. 6. Select the Driver tab. Figure 2-30. 7. Click Update Driver. The Hardware Update Wizard displays.

PG42-1008C 25 2. Installing the drivers Figure 2-31. 8. Select Install from a list or specific location and click Next. 9. Browse to the location of the Metercat installation CD or the installation files and select the \UNICOM III Probe USB drivers folder. 10.Click Next. 11. Click Finish to complete the installation of the UNICOM III USB Optical Probe device drivers.

PG42-1008C 26 2. Installing the drivers Figure 2-32. Note: The Driver Version should be 2.8.2.0. 12.Click Close to close the Properties dialog. 13.Exit the Device Manager. 14.From the Windows Start menu, select Shut Down > Restart. You are now ready to begin using the optical probe.

PG42-1008C 27 3. Using the probe 3 Using the probe Using the UNICOM III Probe (USB connector) After you have installed the device drivers, you need to perform the following procedures before you can begin using the UNICOM III Probe (USB connector): 1. Before you begin using the probe, you must determine the COM port the probe is assigned to. See Determining COM Port Number (below) for details. 2. Once you have determined the assigned COM port, configure your meter support software to use the correct COM port. See the following sections for details: a. Configuring Metercat software on page 29 b. Configuring A1200 ALPHA Meter Support Software on page 29 c. Configuring AlphaPlus software on page 29 Determining COM Port Number Before you can configure your meter support software to use the probe you must perform the following procedure to determine the COM port number Windows has assigned to the USB device. Note: Figures are captured from a computer running Windows 2000; Windows XP dialogs may be slightly different. 1. From the Windows Start menu, select Settings > Control Panel > System. 2. Select the Hardware tab.

PG42-1008C 28 3. Using the probe Figure 3-33. System Properties dialog 3. Click the Device Manager button. A list of devices is displayed. 4. Click to expand Ports (COM & LPT). Figure 3-34. Device Manager dialog

PG42-1008C 29 3. Using the probe 5. Note the COM port number assigned to the new USB device. Configuring support software to use the COM port During the installation of the USB device driver, Windows assigned the USB device to a COM port. Perform the procedure described in Determining COM Port Number on page 27 to determine the COM port number to use to configure the meter support software. Configuring Metercat software To configure Metercat to use the correct COM port for the USB connected probe: 1. From Metercat s Tools menu, select Machine Settings. 2. In the Connection Editor dialog, create or edit an optical probe connection to use the correct COM port. 3. Click OK. Refer to the Metercat User Guide for more detailed information on configuring Metercat to use the correct COM port for the new device. Configuring A1200 ALPHA Meter Support Software To configure A1200 ALPHA Meter Support Software to use the correct COM port for the USB connected probe: 1. From A1200 ALPHA Meter Support Software s Tools menu, select User Preferences. 2. Select the Communications tab and select the correct COM port from the Serial Port drop list. Refer to the A1200 ALPHA Meter Support Software User Guide for more detailed information on configuring A1200 ALPHA Meter Support Software to use the correct COM port for the new device. Configuring AlphaPlus software Note: AlphaPlus release 1.30 supports devices assigned to COM ports greater than 4. To configure AlphaPlus software to use the correct COM port for the USB connected probe: 1. From the AlphaPlus Startup menu, select AlphaPlus System Setup. 2. Select AlphaPlus Options > Communication Options > Serial Probe Connector. 3. Press <F2> to access the drop list and select the correct COM port. 4. Press <F10> to save your changes. Refer to AlphaPlus online help for more detailed information on configuring AlphaPlus software to use the correct COM port. Troubleshooting Port Conflict in Port Usage Some hardware that uses the USB port (for example, a USB cradle for a Palm Pilot) can cause a conflict with a COM Port. The software used for accessing the hardware (for example, HotSync Manager) locks the port in the system even if no hardware is plugged into the port. When the UNICOM III probe (USB connector) is installed, it may be assigned to the same port as the other device. This causes a port conflict to occur when trying to access the port from one of the meter support software applications. To correct the port conflict: 1. Exit the application causing the conflict (such as HotSync Manager), then the port becomes available for the probe.

PG42-1008C 30 3. Using the probe Caution: You cannot restart the conflicting application while the probe is using the port. 2. To change the port number assigned to the probe: a. Open the Device Manager using the procedure described in Determining COM Port Number on page 27. b. Select and expand Ports (COM & LPT) list. c. Select Elster Unicom III USB Optical Probe. d. Right-click and select Properties. The COM port Properties dialog displays. e. Select the Port Settings tab. Figure 3-35. USB Optical Probe (COM) Properties f. Click Advanced.

PG42-1008C 31 3. Using the probe Figure 3-36. Advanced Settings for COM Port g. Change the COM Port Number by selecting one of the unused COM Ports in the drop list. h. Click OK. i. Click OK to return to the Device Manager. 3. Record the COM port number selected and use this port number for the probe address in any meter support software you are using (see Configuring support software to use the COM port on page 29). Multiple USB ports on a computer If you insert the optical probe into a USB port different than the one it was originally installed on, the device drivers will be automatically loaded (Windows 2000) or you will be prompted to load the drivers (Windows XP). A new COM port number is assigned for that USB port.

PG42-1008C 32 4. Installing the UNICOM III with USB to Serial 4 Installing the UNICOM III with USB to Serial Adapter Follow the instructions provided by the adapter manufacturer. If no instructions are provided, perform the following procedure: 1. Plug the USB connector into the USB port on the computer. Windows should automatically recognize the new connection and display the New Hardware Wizard dialog (it may take some time on some systems). 2. If Windows does not start the New Hardware Wizard, from the Start menu, select Settings > Control Panel > Add/Remove Hardware. 3. Follow the installation instructions presented in the New Hardware Wizard. Windows may not automatically select the correct device driver; if you are presented with options for device drivers, select the driver for the Windows operating system and USB connector. To do this you may have to browse to a folder for the Windows operating system and USB device model you have. Optionally, the latest device drivers can usually be downloaded from the manufacturer s web site.

PG42-1008C 33 4. Installing the UNICOM III with USB to Serial

About Elster Elster (NYSE: ELT) is one of the world's largest electricity, gas and water measurement and control providers. Its offerings include distribution monitoring and control, advanced smart metering, demand response, networking and software solutions, and numerous related communications and services - key components for enabling consumer choice, operational efficiency and conservation. Its products and solutions are widely used by utilities in the traditional and emerging Smart Grid markets. Elster has one of the most extensive installed revenue measurement bases in the world, with more than 200 million metering devices deployed over the course of the last 10 years. It sells its products and services in more than 130 countries across electricity, gas, water and multi-utility applications for residential, commercial and industrial, and transmission and distribution applications. ALPHA, ALPHA Plus, REX, TRACE and EnergyAxis are registered trademarks and Metercat and AlphaPlus are trademarks of Elster. Other products and company names mentioned herein may be the trademarks and/or registered trademarks of their respective owners. Elster 208 S Rogers Lane Raleigh, NC 27610-2144 United States T +1 800 338 5251 (US toll free) F +1 919 212 4801 support@us.elster.com www.elster.com 2011 by Elster. All rights reserved. No part of this software or documentation may be reproduced, transmitted, processed or recorded by any means or form, electronic, mechanical, photographic or otherwise, translated to another language, or be released to any third party without the express written consent of the Elster. Printed in the United States of America. 18 April 2011