DATA SHEET DEA GLOBAL SILVER

Similar documents
PRODUCT BROCHURE SF. Shop-Floor Coordinate Measuring Machine

PRODUCT BROCHURE SPATIAL ANALYZER. Powerful, traceable and easy-to-use metrology and analysis software

Types of 3D Scanners and 3D Scanning Technologies.

ENGINEERING METROLOGY

SCS Directory Accreditation number: SCS 0115

Making Better Medical Devices with Multisensor Metrology

Automotive Applications of 3D Laser Scanning Introduction

Length, Finland, MIKES (VTT Technical Research Centre of Finland Ltd, Centre for Metrology / Mittatekniikan keskus)

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

PCB Component Placement Inspection

On an equal level: CT measurements reach the accuracy of conventional tactile metrology

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining

Renishaw apply innovation TM. Calibrating 5-axis machines to improve part accuracy. 5Align

THE OPTICAL CMM 3D SCANNERS FOR INDUSTRIAL APPLICATIONS

Hexagon Metrology & UHA Product Line

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

leica absolute tracker at901

RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website

DryLin ZLW Belt Drive

Who are we. Engineering & Quality. Elements & Moulds. Verification. Approx. 800 employees. Approx.330 employees. Approx. 26 employees.

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Guideline Laser Series

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

Profile rail guides LLR

COMPUTATIONAL ACCURACY ANALYSIS OF A COORDINATE MEASURING MACHINE UNDER STATIC LOAD

Arm2. Arm Arm22. Articulated Arm. machines MEASURING. tridimensional measuring FRATELLI ROTONDI

Industrial Robotics. Training Objective

How To Measure Contactless Measurement On A Robot

BoWex SD, SD1 and SD2 Operating-/Assembly Instructions

Integration Services

Torque Transducers MEASURING ELECTRONIC

National Performance Evaluation Facility for LADARs

Industrial Metrology and Engineering Applications in the Wind Turbine Industry

Introduction to Accuracy and Repeatability in Linear Motion Systems

Quick Reference Catalog

Alignment Laser System.

How To Use A Corona Mdi 110

Subminiature Load Cell Model 8417

Products. Air Bearing- Linear systems EITZENBERGER. Luftlagertechnik GmbH. Feichtmayrstraße 17 D Wessobrunn

Barcode Reader Series BCL 31, BCL 32, BCL 34

Loewe GK Installation and operating manual

ALTERA. Coordinate Measuring Machines. nikon metrology I vision beyond precision

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

SCHMIDT ManualPress 300 Series Manual Presses with Process Monitoring

ELEMENTS OF SOFTWARE INTEGRATION OF PRODUCTION SYSTEMS IN INDUSTRIAL PRODUCT CONTROL AND DIDACTICS 1. INTRODUCTION

3D laser removal and texturing in a new dimension

Machine Tool Inspection & Analyzer solutions

Series 6000 Torque measured metal bellow coupling

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Linear Systems. Main Catalog

Industrial Metrology from Carl Zeiss. Contour and Surface Measuring Machines

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

SEM/FIB Workbench. Klocke Nanotechnik. Microtechnology Network. Motion from the Nanoworld. One of 279 members in a. Pascalstr. 17 Aachen, Germany

Bar code scanners CLV45x / CLV450 / Standard Density

LOCATION DEPENDENCY OF POSITIONING ERROR IN A 3-AXES CNC MILLING MACHINE

HCW 1000 NEW TYPE OF LIGHT MACHINE FROM SKODA

ABERLINK 3D MKIII MEASUREMENT SOFTWARE

ROV Data Collection Results

DMU 75 / 95 monoblock

Application Example: Quality Control of Injection-Molded Parts

Precise heavy-duty cutting

KS-70. Catheterization Table GENERAL

Selecting and Sizing Ball Screw Drives

ŠKODA MACHINE TOOL HORIZONTAL MILLING AND BORING MACHINES ŠKODA HCW

Geometric Camera Parameters

Perthometer. Surface Texture Parameters New Standards DIN EN ISO / ASME

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

MINIMAT-EC-Servo Screwdriver Spindles

How To Fuse A Point Cloud With A Laser And Image Data From A Pointcloud

IP-S2 Compact+ 3D Mobile Mapping System

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Section. Tolerances. Aluminum Extrusion Manual. 4th Edition

Inspection of diffusely reflecting surfaces

Series 7500 Torque Sensor

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

Cross-beam scanning system to detect slim objects. 100 mm in

CNC MILLING TECHNOLOGY FOR THE JEWELER- AND GOLDSMITH HANDCRAFT:

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Machine tools. Milling- and boring machines

SunnyMec 3000 The innovative bi-axial PV tracker Data Sheet

Material test chamber with mechanical convection

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

5-Axis Test-Piece Influence of Machining Position

Measuring thermal drift of machine tools

T-REDSPEED White paper

BARREL ALIGNMENT- A CRITICAL FACTOR IN REDUCING EXTRUDER WEAR

Grazing incidence wavefront sensing and verification of X-ray optics performance

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Mounting Instructions for SP4 Power Modules

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Volume Measurement. TexVol BVM-L Series. Accurate Volume in seconds

Length measuring instruments

INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999

How To Use Bodescan For 3D Imaging Of The Human Body

ROTEX SD shiftable jaw coupling

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

DUGARD. Machine Tools Since Dugard ECO Series Driven Tool, Slant Bed CNC Lathes.

Transcription:

DATA SHEET DEA GLOBAL SILVER 09.xx.08-12.xx.10

Classic Performance Advantage Application Field Top productivity for general metrology applications Top accuracy for point-to-point and scanning measurements Top accuracy and throughput for permanent process control Multisensor Technology Optional Standard Standard Temperature Compensation Optional CLIMA CLIMA CLIMA Performance Environment Standard: 18 22 C, 1 C/h, 2 C/24h Optional CLIMA: 16 26 C, 1 C/h, 5 C/24h Standard: 18 22 C, 1 C/h, 2 C/24h CLIMA: 16 26 C, 1 C/h, 5 C/24h Standard: 18 22 C, 1 C/h, 2 C/24h CLIMA: 16 26 C, 1 C/h, 5 C/24h Max. Scanning 300 mm/s 300 mm/s 500 mm/s Performance data are valid if the following specifications are met Standard Temperature Range 18 22 C Max. air temperature variation 1 C/h - 2 C/24h Max. Spatial Gradient 1 C/m CLIMA Temperature Range 16 26 C Max. air temperature variation 1 C/h - 5 C/24h Max. Spatial Gradient 1 C/m Probe Configuration for performance test TP: Standard force module, stylus length 10 mm, tip diameter 4 mm TESASTAR-p: Standard force, stylus length 10 mm, tip diameter 4 mm TESASTAR-mp: Standard Force Module, stylus length 10 mm, tip diameter 4 mm LSP-X1s: without extension, stylus length 50 mm, tip diameter 5 mm LSP-X1m/X1h: with an extension of 100 mm, stylus length 20 mm, tip diameter 5 mm LSP-X1c: stylus length 20 mm, tip diameter 5 mm /X5: stylus length 60 mm, tip diameter 5 mm 2 DEA GLOBAL SILVER 09.xx.08-12.xx.10 DS CMM 036/01 - EN - 11/12

Probe Heads and Sensors Technical Characteristics Angular rotation Angular rotation step Rotation speed Positioning repeatability Max. applied torque Extensions TESASTAR-sm Probe Head A axis: +90 / -115 B axis: ±1 5 90 in 2 seconds 0.5 μm 0.6 Nm Max. length 300 mm TESASTAR-m Indexable Probe Head Technical Characteristics LSP-X1c LSP-X5 Resolution <1 µm <1 µm <1 µm Measuring range ± 2 mm in X, Y and Z ± 1 mm in X, Y and Z 1 mm in X, Y and Z Overtravel range ± 2 mm in all axes ± 1.25 mm in all axes ± 1 mm in all axes Linear stiffness 1.2 N/mm 5 N/mm 5 N/mm Stylus joint M3 M5 M5 Max. stylus weight 33 g 150 g 500 g Max. stylus length Vertical: 20-115 mm Horizontal: up to 50 mm 360 mm 500 mm CMS106 Laser Sensor Technical Characteristics Laser Visible red, class 2, 690 nm Standoff and depth of FOV 170 ± 30 mm Width of FOV user selectable 24, 60, 124 mm Line per second (max) 53 Hz Temperature range of sensor for declared accuracy 15 ~ 32 C Sensor size L x W x H 134 x 72 x 60,5 mm Sensor weight 382 g Probing error (*) F(OT) 60 µm (*) According to VDI 2617 Part 6.2, October 5 edition DEA GLOBAL SILVER 09.xx.08-12.xx.10 DS CMM 036/01 - EN - 11/12 3

DEA GLOBAL Silver Classic 09.12.08, 09.15.08, : Strokes, Dimensions and s Specifications according to ISO 10360-2:1, second edition and ISO 10360-4:0 first edition Probe Configuration Standard Temperature Range 18 22 C CLIMA Temperature Range 16 26 C (mm/s) Accel. (mm/s 2 ) TS-m, TS-sm/TS-p, TS-mp, TP 2.7 + L/300 2.7 2.8 + L/250 2.7 1 TS-m, TS-sm/LSP-X1s, m, h + L/300 3.9/68 2.5 + L/250 3.9/68 1 LSP-X1c + L/300 3.9/68 2.5 + L/250 3.9/68 156 LX 100 140 Y 09.12.08 LZ 156 Z 275 140 09.15.08 DZ1 230 DZ SY1 SY2 PY LY 160 66 860 X LX1 60 101.5 111 92.5 68.5 32.4 75.4 56.4 LSP-X1c TESASTAR-m TESASTAR-sm Models Strokes Overall Dimensions X Y Z LX LX1 LY LZ Surface Plate Daylights Supports Thd Insert PY DZ DZ1 SY1 SY2 Max. Part CMM 09.12.08 09.15.08 0 2165 2465 2965 2 2 2 1910 2210 2710 455 540 6 1130 1350 100.6 24.4 50.6 1 1650 1850 4 DEA GLOBAL SILVER 09.xx.08-12.xx.10 DS CMM 036/01 - EN - 11/12

DEA GLOBAL Silver Performance 09.12.08, 09.15.08, : Strokes, Dimensions and s Specifications according to ISO 10360-2:1, second edition and ISO 10360-4:0 first edition Probe Configuration Standard Temperature Range 18 22 C CLIMA Temperature Range 16 26 C (mm/s) Accel. (mm/s 2 ) TS-m, TS-sm/TS-p, TS-mp 2.1 + L/333 2.0 2.4 + L/250 2.0 1 TS-m, TS-sm/TP 1.9 + L/333 1.9 2.1 + L/250 1.9 1 TS-m, TS-sm/LSP-X1s, m, h + L/333 2.9/45 2.1 + L/250 2.9/45 1 + L/333 2.9/45 2.1 + L/250 2.9/45 140 156 LX Y LZ 156 Z SY1 SY2 PY LY 111 101 100 09.12.08 275 140 DZ1 230 DZ 09.15.08 160 860 66 X 60 LX1 92.5 32.4 68.5 75.4 56.4 TESASTAR-m TESASTAR-sm Models Strokes Overall Dimensions X Y Z LX LX1 LY LZ Surface Plate Daylights Supports Thd Insert PY DZ DZ1 SY1 SY2 Max. Part CMM 09.12.08 09.15.08 0 2165 2465 2965 2 2 2 1910 2210 2710 455 540 6 1130 1350 100.6 24.4 50.6 1 1650 1850 DEA GLOBAL SILVER 09.xx.08-12.xx.10 DS CMM 036/01 - EN - 11/12 5

DEA GLOBAL Silver Advantage 09.12.08, 09.15.08, : Strokes, Dimensions and s Specifications according to ISO 10360-2:1, second edition and ISO 10360-4:0 first edition Probe Configuration Standard Temperature Range 18 22 C CLIMA Temperature Range 16 26 C (mm/s) Accel. (mm/s 2 ) TS-m, TS-sm/TS-p, TS-mp 2.1 + L/333 2.0 2.4 + L/250 2.0 TS-m, TS-sm/TP 1.9 + L/333 1.9 2.1 + L/250 1.9 TS-m, TS-sm/LSP-X1s, m, h 1.4 + L/333 1.4 2.5/45 1.7 + L/250 1.4 2.5/45 /X5 1.4 + L/333 1.4 2.5/45 1.7 + L/250 1.4 2.5/45 LY LX Y Z LZ 2148 DZ1 PZ SY1 SY2 70 X 69 PY 910 25 LX1 56 196 196 75.4 56.4 32.4 101 267 91.5 TESASTAR-sm 09.15.08 09.12.08 111 92.5 68.5 191.5 ( a ) With LSP-X5 probe head, Z stroke = 665 mm TESASTAR-m LSP-X5 Models Strokes Overall Dimensions X Y Z (a) LX LX1 LY LZ Surface Plate Daylights Supports PY PZ DZ1 SY1 SY2 Thd Insert Max. Part CMM 09.12.08 1538 1457 2430 3066 2030 250 936 550 1100 76 2286 09.15.08 1538 1457 2730 3066 2330 250 936 600 51 2567 0 1538 1457 3230 3091 725 2830 275 936 126 1 3316 6 DEA GLOBAL SILVER 09.xx.08-12.xx.10 DS CMM 036/01 - EN - 11/12

DEA GLOBAL Silver Performance 12.15.10, 12.10, 12.30.10: Strokes, Dimensions and s Specifications according to ISO 10360-2:1, second edition and ISO 10360-4:0 first edition Probe Configuration Standard Temperature Range 18 22 C CLIMA Temperature Range 16 26 C (mm/s) Accel. (mm/s 2 ) TS-m, TS-sm/TS-p, TS-mp 2.7 + L/333 2.7 3.1 + L/ 2.7 433 TS-m, TS-sm/TP 2.5 + L/333 2.5 2.8 + L/ 2.5 433 TS-m, TS-sm/LSP-X1s, m, h 2.4 + L/333 2.4 4.7/45 2.8 + L/ 2.4 4.7/45 433 2.4 + L/333 2.4 4.7/45 2.8 + L/ 2.4 4.7/45 433 273 273 LX Y Z LZ SY1 SY2 PY LY 111 101 12.15.10 12.10 12.30.10 LZ1 PZ 150 DZ1 70 X 69 1210 25 7 56 92.5 68.5 75.4 56.4 66.5 32.4 66.5 TESASTAR-m TESASTAR-sm Models Strokes Overall Dimensions X Y Z LX LY LZ LZ1 Surface Plate Daylights Supports PY PZ DZ1 SY1 SY2 Thd Insert Max. Part CMM 12.15.10 20 3431 2307 625 24 290 3 650 149 1 3792 12.10 2 35 3406 2282 600 31 350 3 1630 149 5679 12.30.10 3000 43 3431 2307 625 39 3 3 19 24 7587 DEA GLOBAL SILVER 09.xx.08-12.xx.10 DS CMM 036/01 - EN - 11/12 7

DEA GLOBAL Silver Advantage 12.15.10, 12.10, 12.30.10: Strokes, Dimensions and s Specifications according to ISO 10360-2:1, second edition and ISO 10360-4:0 first edition Probe Configuration Standard Temperature Range 18 22 C CLIMA Temperature Range 16 26 C (mm/s) Accel. (mm/s 2 ) TS-m, TS-sm/TS-p, TS-mp 2.7 + L/333 2.6 3.1 + L/ 2.6 TS-m, TS-sm/TP 2.5 + L/333 2.8 + L/ TS-m, TS-sm/LSP-X1s, m, h 2.1 + L/333 3.1/45 2.5 + L/ 3.1/45 /X5 2.1 + L/333 3.1/45 2.5 + L/ 3.1/45 LX Y Z LZ1 PZ 150 DZ1 LZ SY1 SY2 PY LY 70 X 69 1210 25 7 56 273 273 75.4 56.4 32.4 101 66.5 66.5 TESASTAR-sm 12.15.10 12.10 12.30.10 111 92.5 68.5 191.5 ( a ) With LSP-X5 probe head, Z stroke =905 mm TESASTAR-m LSP-X5 Models Strokes Overall Dimensions X Y Z (a) LX LY LZ LZ1 Surface Plate Daylights Supports PY PZ DZ1 SY1 SY2 Thd Insert Max. Part CMM 12.15.10 20 3431 2307 625 24 290 3 650 149 1 3792 12.10 2 35 3406 2282 600 31 350 3 1630 149 5679 12.30.10 3000 43 3431 2307 625 39 3 3 19 24 7587 DEA GLOBAL SILVER 09.xx.08-12.xx.10 DS CMM 036/01 - EN - 11/12 8

Performance Verification : Maximum Permissible Error of indication for size measurement Measurement of a set of 5 sizes, taken through two opposite probing points on two nominally parallel planes. The set of 5 sizes is placed in 7 different positions/directions within the measuring volume. Each size is measured three times for a total of 105 measurements. All 105 measurement results (100%) must be within the specified. : Maximum permissible probing error A reference sphere is measured with 25 equally distributed probings. The probing performance shall be verified in one single position, located in the middle of the CMM working volume. Using all 25 measurements, compute the Gaussian associated sphere. For each of the 25 measurements, calculate the Gaussian radial distance, R. Calculate the probing error, P, as the range of the 25 Gaussian distances, Rmax - Rmin. The probing error P must be within the stated. : Maximum permissible scanning probing error is the Maximum Permissible Scanning Probing Error of the range of all radii (sphere form error), with high point density and predefined path scanning, where τ is the specified time (in seconds) needed to perform the verification test. The scanning probing performance shall be verified in one single position, located in the middle of the CMM working volume. A reference sphere is measured by scanning four target scan lines to determine the range of the radial distance R. The scanning probing error THP is calculated as the range of radii between the measured centre and all of the assessed scan points. The measured THP and the time needed to perform the scanning test must be within the specified. Technical Characteristics Mechanical Frame: Surface Plate: Sliding System: Measuring System: Temperature Compensation: Ram Counterbalance: Air Supply: X: Micromachined anodized light alloy extrusion Y: Integral dovetail guideways, machined into the table Z: Micromachined anodized light alloy extrusion Material: Granite Part Locking: threaded inserts M8 x 1.25 Flatness: according to DIN 876/III Air bearings on all axes METALLUR linear scales. System Resolution: 0.039 μm CLIMA: Multisensor Temperature Compensation Technology, 16 26 C (optional on Classic models) Pneumatic, adjustable Minimum air supply pressure: 0.5 MPa Air consumption: 150 Nl/min Environment: Metrological specification temperature range: Standard: 18 22 C and CLIMA: 16 26 C Operating Temperature: 10 45 C Relative humidity: 20% - 90 % non condensing Probe Heads and Sensors: TESASTAR-m, TESASTAR-sm, LSP-X1c,, LSP-X5 TP, TESASTAR-p, TESASTAR-mp, LSP-X1, CMS106 DEA GLOBAL SILVER 09.xx.08-12.xx.10 DS CMM 036/01 - EN - 11/12 9

Laser Trackers & Stations Portable Measuring Arms BRIDge CMMs Horizontal Arm CMMs Gantry CMMs Multisensor & Optical Systems White light scanners Ultra High Accuracy CMMS sensors Precision Measuring Instruments Software Solutions Hexagon Metrology offers a comprehensive range of products and services for all industrial metrology applications in sectors such as automotive, aerospace, energy and medical. We support our customers with actionable measurement information along the complete life cycle of a product from development and design to production, assembly and final inspection. With more than 20 production facilities and 70 Precision Centers for service and demonstrations, and a network of over 100 distribution partners on five continents, we empower our customers to fully control their manufacturing processes, enhancing the quality of products and increasing efficiency in manufacturing plants around the world. Hexagon Metrology is part of Hexagon (Nordic exchange: HEXA B). Hexagon is a leading global provider of design, measurement and visualisation technologies that enable customers to design, measure and position objects, and process and present data. Learn more at www.hexagon.com For more information, visit www.hexagonmetrology.com 2012 Hexagon Metrology. Part of Hexagon 773179 All rights reserved. Due to continuing product development, Hexagon Metrology reserves the right to change product specifications without prior notice. Printed in Germany. June 2013